• 제목/요약/키워드: main control valve

검색결과 158건 처리시간 0.024초

파일럿형 공기압 방향제어 밸브의 누설 고장판정 기법에 관한 연구 (Leakage Failure Determination Method of Pilot Pneumatic Directional Control Valve)

  • 강보식;김경수;장무성
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제14권4호
    • /
    • pp.230-235
    • /
    • 2014
  • The failure modes of pneumatic directional control valves include leakage, wear of the spool seal, and sticking of the spool. Among them, the main failure mode of the valve is leakage. The leakage is caused by the wear of the spool seal. However, due to the characteristics of the seal material, the leakage rate is fluctuated a lot rather than constantly increased over time. If life analysis is performed using the first time data of leakage failure, predicted life cycles can be different from the real life cycles. This paper predicts life cycles of the pilot pneumatic directional control valve based on the three point moving average which considers the average of the fluctuating leakage rate.

Independent Metering Valve: A Review of Advances in Hydraulic Machinery

  • Nguyen, Thanh Ha;Do, Tri Cuong;Ahn, Kyoung Kwan
    • 드라이브 ㆍ 컨트롤
    • /
    • 제17권4호
    • /
    • pp.54-71
    • /
    • 2020
  • In light of the environmental challenges, energy-saving strategies are currently under investigation in the construction industry. This paper focuses on the energy-saving method used in the hydraulic system based on independent metering (IM) technologies, which can overcome the lost energy at the main control valve of the conventional electrohydraulic servo system. By scientifically arranging the proportional valves, the IM system can individually control the flow rate of the inlet and the outlet ports of the actuators. In addition, the IMV system can be used to effectively regenerate energy under different operating modes, thereby saving more energy than conventional hydraulic systems. Therefore, the IMV system has a great potential to improve the energy efficiency of hydraulic machinery. The overall IMV system, including the configuration, proportional valve, operation mode, and the control strategy is introduced via state-of-the-art hydraulic technologies. Finally, the challenges of IM systems are discussed to provide researchers with directions for future development.

파워 스티어링용 베인 펌프 유량 제어부 설계에 관한 연구 (A Study on the Design of Flow Control Valve Attached to Vane Pump for Power Steering)

  • 이윤태
    • 한국생산제조학회지
    • /
    • 제9권5호
    • /
    • pp.87-95
    • /
    • 2000
  • The numerical analysis and the experiments are carried out to develop the design program for the flow control valve attached to the vane pump for power steering. The factors affecting the flow rate characteristics are analyzed by the experiments and the numerical analysis. The results are summarized as follows; (1) the main factors affecting to the first and second control flow rate are the diameter of big and small rod of the spool. (2) the cut off is mainly affected by the main spring constant, the initial displacement of main spring and the small diameter of the spool. (3) the dropping slope characteristics are decided by the chamfer of spool and the dynamic characteristics of the spool.

  • PDF

유압 굴삭기용 폐루프 타입 MCV(Main Control Valve) (Closed loop type MCV(Main Control Valve) for Hydraulic Excavator)

  • 임태형;이홍선;양순용
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.864-870
    • /
    • 2005
  • Hydraulic excavators have been popular devices in construction field because of its multi-workings and economic efficiency. The mathematical models of excavators have many nonlinearities because of nonlinear opening characteristics and dead zone of main control valve, oil temperature variation, etc. The objective of this paper is to develop a simulator for hydraulic excavator using AMESim. Components and whole circuit are expressed graphically. Parameters and nonlinear characteristics are inputted in text style. From the simulation results, fixed spring stiffness of MCV can't satisfy accuracy of spool displacement under whole P-Q diagrams. Closed loop type MCV containing proportional gain is proposed in this paper that can reduce displacement error. The ability of closed loop MCV is verified through comparing with normal type MCV using AMESim simulator. The simulator can be used to forecastexcavator behavior when new components, new mechanical attachments, hydraulic circuit changes, and new control algorithm are applied. The simulator could be a kind of development platform for various new excavators.

  • PDF

연소기 산화제 개폐밸브 닫힘 작동특성 (Closing Characteristics of a Main Oxidizer Shut-off Valve)

  • 홍문근
    • 한국항공우주학회지
    • /
    • 제48권9호
    • /
    • pp.717-724
    • /
    • 2020
  • 본 논문에서 액체로켓엔진용 연소기 산화제 개폐밸브로 사용되는 밸브 개방 자체유지가능형 포핏 밸브의 밸브 닫힘 작동특성에 대한 연구 내용을 소개하기로 한다. 상온 및 극저온 환경에서 밸브 닫힘 특성을 예측할 수 있는 수치해석 방법을 제시하였으며, 시험결과와의 비교를 통해 계산결과의 신뢰성을 검증하였다. 본 연구를 통해 상온 및 극저온 작동 환경에서 각각 구동가스 배출 시스템의 유효 유로 면적과 밸브 작동부에 작용하는 운용유체의 압력 분포가 밸브의 전반적인 닫힘 작동특성을 좌우하는 주요 변수인 것을 확인하였다. 또한 극저온 작동 환경에서 구동가스를 적절히 활용함으로써, 밸브 닫힘 압력을 유연하게 조정할 수 있을 뿐만 아니라 밸브 닫힘 속도 또한 효과적으로 감소시킬 수 있음을 확인하였다.

가압펌프장의 수격완화설비에 대한 보수·보강 사례 (Case Study of Repair Works on Surge Suppression Device for Booster Pumping Station)

  • 김상균;이동근;이계복;김경엽
    • 한국유체기계학회 논문집
    • /
    • 제8권4호
    • /
    • pp.20-26
    • /
    • 2005
  • When the pumps are started or stopped for the operation or tripped due to the power failure, the hydraulic transients occur as a result of the sudden change in velocity. The field tests on the waterhammer were carried out for Pangyo booster pumping station in which had six booster pumps and two in-line pumps with the motor of output 1,700 kW, respectively. The booster pumping station was equipped with the pump control valve as the main surge suppression device, and the surge relief valve as auxiliary one. But the pump control valve had not early controlled in the planned closing mode, the slamming occurred to the valve of which abruptly closed during the large reverse flow. Because the positive pressure wave caused by the pump failure was superposed on the slam surge, the upsurge increased so extremely that the pump control valve was damaged. After the air chambers were additionally installed in the booster pumping station, it was preyed that the water supply system acquire the safety and reliability on the pressure surge.

액체로켓엔진용 연소기 산화제 개폐밸브 성능 특성 (Performance Characteristics of a Main Oxidizer Shutoff Valve for Liquid Rocket Engines)

  • 정대성;홍문근;한상엽
    • 한국추진공학회지
    • /
    • 제21권4호
    • /
    • pp.28-35
    • /
    • 2017
  • 액체 추진 로켓 엔진에서 연소실로 향하는 산화제 공급은 연소기 산화제 개폐밸브에 의해서 제어된다. 산화제의 안정적인 공급을 위하여 밸브가 열려있을 때의 유량조건을 만족해야 할 뿐만 아니라, 산화제 공급라인의 예냉을 위해 밸브가 닫혀있을 때에도 요구되는 유량조건을 만족해야 한다. 본 연구에서는 연소기 산화제 개폐밸브의 재순환 유량특성을 확인하기 위한 시험을 수행하였고, 밸브 내부에 작용하는 힘평형 관계식을 이용하여 극저온 수명시험 이후 스프링 상수가 변화하는 경향을 확인하였다.

밸브 오버랩 기간이 없는 흡기관 분사식 수소기관의 성능 및 역화특성 (Characteristics of Performance and Back-Fire for External Mixture Hydrogen Fueled Engine without Valve Overlap Period)

  • 이광주;강준경;;노기철;이종태
    • 한국수소및신에너지학회논문집
    • /
    • 제18권4호
    • /
    • pp.374-381
    • /
    • 2007
  • In order to verify the feasibility of expansion of back-fire limit equivalence ratio in the hydrogen-fueled engine with external mixture, the characteristics of performance and combustion are experimentally analyzed with change of intake/exhaust valve timings under the fixed valve overlap period of $0^{\circ}$ CA(non-valve overlap period). These characteristics are also tested for the change of exhaust valve closing timing while intake valve opening timing is fixed to clear the main cause of back-fire occurrence. As the results, the less valve overlap period center is retarded, the more back-fire limit equivalence ratio increases and back-fire does not occurred after TDC. In addition, it was shown that the control of back-fire is dependent on intake valve opening timing than valve overlap period.

Cause Analysis of Flow Accelerated Corrosion and Erosion-Corrosion Cases in Korea Nuclear Power Plants

  • Lee, Y.S.;Lee, S.H.;Hwang, K.M.
    • Corrosion Science and Technology
    • /
    • 제15권4호
    • /
    • pp.182-188
    • /
    • 2016
  • Significant piping wall thinning caused by Flow-Accelerated Corrosion (FAC) and Erosion-Corrosion (EC) continues to occur, even after the Mihama Power Station unit 3 secondary pipe rupture in 2004, in which workers were seriously injured or died. Nuclear power plants in many countries have experienced FAC and EC-related cases in steam cycle piping systems. Korea has also experienced piping wall thinning cases including thinning in the downstream straight pipe of a check valve in a feedwater pump line, the downstream elbow of a control valve in a feedwater flow control line, and failure of the straight pipe downstream of an orifice in an auxiliary steam return line. Cause analyses were performed by reviewing thickness data using Ultrasonic Techniques (UT) and, Scanning Electron Microscope (SEM) images for the failed pipe, and numerical simulation results for FAC and EC cases in Korea Nuclear Power Plants. It was concluded that the main cause of wall thinning for the downstream pipe of a check valve is FAC caused by water vortex flow due to the internal flow shape of a check valve, the main cause of wall thinning for the downstream elbow of a control valve is FAC caused by a thickness difference with the upstream pipe, and the main cause of wall thinning for the downstream pipe of an orifice is FAC and EC caused by liquid droplets and vortex flow. In order to investigate more cases, additional analyses were performed with the review of a lot of thickness data for inspected pipes. The results showed that pipe wall thinning was also affected by the operating condition of upstream equipment. Management of FAC and EC based on these cases will focus on the downstream piping of abnormal or unusual operated equipment.

Flow Divider Valve의 최적설계를 위한 동특성 해석 (Dynamic Characteristics Analysis for Optimal Design of Flow Divider Valve)

  • 황태영;박태조
    • 연구논문집
    • /
    • 통권29호
    • /
    • pp.123-130
    • /
    • 1999
  • Flow divider valve는 한 개의 공급라인에서 두 개 이상의 출력라인으로 유압유를 일정비율로 분배하는 유압제어밸브로서 하중압력이나 공급압력 등에 관계없이 항상 일정비율의 유량분배가 가능해야 한다. 현재 상용제품의 유량분할 정확도는 90~95% 수준이며, 이러한 유량분할오차(Flow dividing error)는 유압시스템에 누적오차로 작용하여 많은 문제점을 야기시키고 있어 보다 고정밀 유량제어가 가능한 Flow divider valve 개발이 요구된다. 본 연구에서는 외력을 고려한 스푸울의 거동을 수치적으로 정확하게 조사하여 Flow divider valve의 동특성을 규명함과 동시에 유량분할 오차를 감소시키는 최적설계방안을 제시하고자 한다. 동특성 해석은 일정한 하중저항을 입력신호로 작용하는 경우에 대해서 제시하였으며, 이때의 고정오리피스와 가변오리피스의 단면적 및 스푸울의 단면적 변화에 따른 동특성의 변화를 조사하였다.

  • PDF