• Title/Summary/Keyword: main control valve

Search Result 158, Processing Time 0.028 seconds

Optimization of Design Parameters of a EPPR Valve Solenoid using Artificial Neural Network (인공 신경회로망을 이용한 전자비례 감압밸브의 솔레노이드 형상 최적화)

  • Yoon, Ju Ho;Nguyen, Minh Nhat;Lee, Hyun Su;Youn, Jang Won;Kim, Dang Ju;Lee, Dong Won;Ahn, Kyoung Kwan
    • Journal of Drive and Control
    • /
    • v.13 no.2
    • /
    • pp.34-41
    • /
    • 2016
  • Unlike the commonly used On/Off solenoid, constant attraction force which is independent of plunger displacement is a considerably important characteristic to proportional solenoid of the EPPR Valve. Attraction force uniformity is mainly affected by the internal shape design parameters. Due to a number of shape design parameters, the optimal parameter values are very complex and time consuming to find by trial and error method. Much research has been conducted or are still in progress to find the optimal parameter values by applying various optimization techniques like Genetic Algorithm, Evolution Strategy, Simulated Annealing, or the Taguchi method. In this paper, the design parameters which have primary effects on the attraction force uniformity and the average attraction force are decided by main effects analysis of Design of Experiments. Optimal parameter values are derived using finite-element analysis and a neural network model.

Regression of Left Ventricular Mass after Aortic Valve Replacement in Isolated Aortic Regurgitation (단독 대동맥판막 폐쇄부전 환자에서 대동맥판막 치환술 후 좌심실 질량의 변화)

  • Jung, Tae-Eun;Lee, Dong-Hyup;Lee, Seok-Soo
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.614-618
    • /
    • 2010
  • Background: The aim of our study was to assess the extent of regression of left ventricular mass after aortic valve replacement in isolated aortic regurgitation. Material and Method: Retrospective analysis of echocardiographic data was collected preoperative and postoperative 1 year. There were 20 patients (12 males, 8 females, mean age $55.8{\pm}11.8$ years, mean body surface area $1.64{\pm}0.19m^2$) with aortic regurgitation from 2002 through 2007. We studied the change of left ventricular ejection fraction, ventricular septum and left ventricular posterior wall thickness, and left vemtricular muscle index (LVMI). The control group was age matched with normal echocardiographic study results. Patients with combined surgery or infective endocarditis were excluded. Result: Seven cases of tissue valves and thirteen cases of mechanical valve were used. The valve sizes were 21 mm (3 cases), 23 mm (13 cases) and 25 mm (4 cases). The postoperative ($125.5{\pm}42g/m^2$) LVMI has decreased than preoperative LVMI ($212.3{\pm}80g/m^2$, p=0.000) but higher than that of control group ($80.5{\pm}15.9g/m^2$, p=0.000). Postoperative septal wall (systolic/diastolic: $13.5{\pm}3.4mm/17.1{\pm}4.1mm$) and left ventricular posterior wall (systolic/diastolic: $12.9{\pm}3.4mm/16.7{\pm}3.4mm$) thickness were slightly decreased after the valve replacement but was not significantly different than preoperative levels. And postoperative interventricular septal wall and left ventricular posterior wall thickness (systolic/diastolic: $8.6{\pm}1.4mm/12.1{\pm}1.7mm$, systolic/diastolic: $8.4{\pm}1.4mm/13.2{\pm}1.9mm$) were higher than that of the control group (p<0.001). Conclusion: The significant regression of LVMI after aortic valve replacement developed at postoperative one year but the level was higher than control group. The main cause of decreased LVMI is decreased in left ventricular dimension.

A Study on the Noise Reduction of Reciprocating Type Air Compressors

  • Lee Kwang-Kil;Kim Kwang-Jong;Lee Gwan-Hyung;Park Jae-Suk;Son Doo-ik;Kim Bong-Ki;Lee Dong-Ju
    • International Journal of Safety
    • /
    • v.3 no.1
    • /
    • pp.6-9
    • /
    • 2004
  • This paper deals with the noise evaluation technique of a reciprocating air-compressor and its noise reduction. The reciprocating air-compressors are widely used in the small, medium sized industrial firms, and lots of their employees are affected and irritated by their noise in the workplace. Thus, noise control actions should be taken appropriately by considering the hearing loss due to the occupational noise exposure. Lead-wrapping techniques are employed to identify the contribution of principal noise sources which are generally known as motor, belts, suction/discharge valves, moving pistons, and flow-induced noise caused by edges or discontinuities along the flow path e.g. expansions, contractions, junctions and bends etc .. As a result, main noise sources of the air-compressor can be categorized by the suction/discharge noise, valve noise, and compressed-air tank noise. Based on the investigations, mufflers are designed to reduce both the suction/discharge noise and the compressed-air tank noise. Instead of the conventional valve plate, polyethylene resin is used as a new one for the reduction of valve impact noise. In addition, attempts are made to reduce the valve noise propagation to the cylinder head and the compressor tank by using the insulation casings. As a result of the countermeasure plans, it can be achieved that the noise reduction of the air-compress is up to 10dB.

Simulator for Hydraulic Excavator

  • Lim, Tae-Hyeong;Lee, Hong-Seon;Yang, Soon-Yong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2071-2075
    • /
    • 2005
  • Hydraulic excavators have been popular devices in construction field because of its multi-workings and economic efficiency. The mathematical models of excavators have many nonlinearities because of nonlinear opening characteristics and dead zone of main control valve, oil temperature variation, etc. The objective of this paper is to develop a simulator for hydraulic excavator using AMESim. Components and whole circuit are expressed graphically. Parameters and nonlinear characteristics are inputted in text style. The simulator can be used to forecast excavator behavior when new components, new mechanical attachments, hydraulic circuit changes, and new control algorithm are applied. The simulator could be a kind of development platform for various new excavators.

  • PDF

Remote Monitoring Panel and Control System for Chemical, Biological and Radiological Facilities (화생방 방호시설을 위한 원격감시 패널 및 제어시스템)

  • Park, Hyoung-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.464-469
    • /
    • 2019
  • A remote monitoring panel and control system was developed to control various valves and access control chambers, including gas shutoff valves used in CBR(Chemical, Biological and Radiological) facilities. The remote monitoring panel consisted of a main panel installed in the NBC (Nuclear, Biological and Chemical) control room and auxiliary panel installed in the clean room, and the size was divided into pure control and control including CCTV. This system can be monitored and controlled remotely according to the situation where an explosion door and gas barrier door can occur during war and during normal times. This system is divided into normal mode and war mode. In particular, it periodically senses the operation status of various valves, sensors, and filters in the CBR facilities to determine if each apparatus and equipment is in normal operation, and remotely alerts situation workers when repair or replacement is necessary. Damage due to the abnormal operation of each device in the situation can be prevented. This enables control of the blower, supply and exhaust damper, emergency generator, and coolant pump according to the state of shutoff valve and positive pressure valve in the occurrence of NBC, and prevents damage caused by abrupt inflow of conventional weapons and nuclear explosions.

Electro-pneumatic regulator using multilayer PZT actuator (적층형 압전액추에이터 방식 전-공 레귤레이터)

  • Yun, So-Nam;Kim, Chan-Yong;Park, Jung-Ho;Youn, Dong-Won
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.979-984
    • /
    • 2007
  • This paper presents a new control mechanism for the proportional pressure control which is accomplished by electro-pneumatic regulator using two PZT actuators. The electro-pneumatic regulator of this study is 2-stage type and consists of two piezoelectric actuators, a controller and a main poppet valve. The piezoelectric actuators are multilayer bender type and are controlled by digital signal. Proportional pressure control technique is very important because that can derive improvement of product quality and driving ability in the pneumatic system. Solenoid actuator method for pressure control is widely used but this actuator has a high power consumption characteristics. So new actuator is required for the energy saving. In this study, PZT actuator for the pressure control was fabricated and experimented instead of the conventional type solenoid actuator. Experiments for the new control mechanism of the elector-pneumatic regulator were operated under the input condition of 0.4[MPa] and it was confirmed that this mechanism has a good control characteristics to the response sensitivity and hysteresis.

  • PDF

Analysis of the Driving Performance in Piezo Injector for Clean Diesel Engine (친환경 디젤엔진용 차세대 피에조 인젝터의 구동성능 해석)

  • Lee, Jin-Wook;Kang, Kern-Yong;Min, Kyoung-Doug
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.33-34
    • /
    • 2006
  • In this study, a prototype piezo-driven Injector. as a new method driven by piezoelectric energy, has been designed and fabricated based on the concept of inverse piezo-electric effect to overcome the major drawbacks of conventional solenoid-driven injector with a fixed and slow control of injection rate. The effects of an electric control between the solenoid valve and piezo-ceramic stack for injector needle's driving on the dynamic characteristics were usually investigated. We found that this piezo-electric actuator has the main advantage to drastically reducing the time of injector nozzle opening, as well to exert higher force output levels.

  • PDF

Development and Application of Simulator for Hydraulic Excavator (유압 굴삭기용 시뮬레이터 개발 및 응용)

  • Lim, Tae-Hyeong;Yang, Soon-Yong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.9 s.186
    • /
    • pp.142-148
    • /
    • 2006
  • Hydraulic excavators have been popular devices in construction fields because of their multi-workings and economic efficiency. The mathematical models of excavators have many nonlinearities because of opening characteristics and dead zone of main control valve(MCV), oil temperature variation, etc. The objective of this paper is to develop a simulator for hydraulic excavator using AMESim. Components and their circuits are expressed graphically. Also, parameters and nonlinear characteristics are considered in a text style. From the simulation results, fixed spring stiffness of MCV can not obtain the satisfactory accuracy of spool displacement under whole P-Q diagrams. Closed loop type MCV containing a proportional gain, is proposed in this paper that can reduce displacement error. The ability of closed loop MCV is verified through comparing with normal type MCV using AMESim simulator. The excavator simulator can be used to forecast the attachment behaviors when components, mechanical attachments and hydraulic circuits change, or other control algorithms are applied. The simulator could be a kind of development platform for new excavators.

Development of Simulator for Hydraulic Excavator (유압 굴삭기 시뮬레이터 개발)

  • Lim T.H.;Lee H.S.;Yang S.Y.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.2 no.1
    • /
    • pp.9-14
    • /
    • 2005
  • Hydraulic excavators have been popular devices in construction field because of its multi-workings and economic efficiency. The mathematical models of excavators have many nonlinearities because of nonlinear opening characteristics and dead zone of main control valve, oil temperature variation, etc. The objective of this paper is to develop a simulator for hydraulic excavator using AMESim. Components and whole circuit are expressed graphically. Parameters and nonlinear characteristics are inputted in text style. The simulator can be used to forecast excavator behavior when new components, new mechanical attachments, hydraulic circuit changes, and new control algorithm are applied. The simulator could be a kind of development platform for various new excavators.

  • PDF

Development of Portable System for Measuring pH in Blood (휴대용 혈중pH 측정시스템의 구현)

  • 정도운;김우열;배진우;강성철;심윤보;전계록
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.195-198
    • /
    • 2001
  • We developed the portable blood analysis system, which can be measured pH of the blood. This system is composed to electronic circuit, mechanism, and system software. Electronic circuit is composed to the sensor, pre-amp part, temperature regulation part, fluid sensing part, A/D(analog to digital) conversion part, main and peripheral device processing part. And the mechanism is composed to the flow cell and the liquid flow part. The liquid flow part is consisted of blood and washing control system under the control of the 6-channel solenoid valve and syringe rump. The system software is composed to measurement program, calibration program, washing and diagnostic program. The program of each routine is designed as sequential process for an efficiency. And the portable pH analysis system used two-point calibration method using the two types of corrective liquid. As a result, we obtained the calibration curve and calculated the value of pH. For verifying the system, we confirmed the output voltage of the sensor, and estimated reappearance of system using the standard liquid.

  • PDF