• Title/Summary/Keyword: magnetized water

Search Result 18, Processing Time 0.026 seconds

Effect of Magnetized Water on Cryopreservation in Bovine Spermatozoa (자기활성수가 소 정액 동결에 미치는 영향)

  • Seo, Gi-Beom;Lee, Yong-Seung;Lee, Kyung-Jin;Yu, Han-Jun;Cheong, Hee-Tae;Yang, Boo-Keun;Lee, Seung-Hwan;Lee, Jin-Woo;Park, Choon-Keun
    • Reproductive and Developmental Biology
    • /
    • v.35 no.3
    • /
    • pp.363-367
    • /
    • 2011
  • The purpose of this study was to improve of frozen-thawed sperm using magnetized water in Korean native cattle. Before cryopreservation, without egg-yolk Triladyl$^{(R)}$ solution was flowed though magnet [0, 2000, 4000 and 6000 Gauss(G)] for S min. The freezing of dilluted semen added with Triladyl containing 20% egg-yolk. Analysis of frozen-thawed sperm was estimated viability with SYBR14/PI double stain, membrane intact with hypoosmotic swelling test (HOST), acrosome reaction with FITC-PNA, mitochondria membrane function with Rhodamin 123 by flow- cytometry. Sperm viability was significantly higher in 4000G group than other groups (p<0.05). However, the Hypoosmotic Swelling Test(HOST) was significantly higher in fresh, 4000 and 6000G than 0 and 2000G (p<0.05). In addition, mitochondria membrane damage and acrosome damage were significantly lower in 6000G group than other groups (p<0.05). in conclusion we suggest that magnetized water could be improve ability of sperm on cryopreservation in Korean native cattle.

Performance Evaluation of a Rapid Three Dimensional Diffusion MRI

  • Numano, Tomokazu;Homma, Kazuhiro;Nishimura, Katsuyuki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.356-358
    • /
    • 2002
  • MRI, particularly diffusion weighted imaging (DWI), plays vital roles in detection of the acute brain infarction$\^$1-4/ and others metabolic changes of biological tissues. In general, every molecule in biological tissues may diffuse and move randomly in three-dimensional space. However, in clinical diagnosis, only 2D-DWI is used. The authors have developed a new method for rapid three-dimensional DWI (3D-DWI). In this method, by refocusing of the magnetized spin with the applied gradient field, direction of which is opposite to phase encoding field. Magnetized spin of $^1$H is kept under the SSFP (steady state free precession)$\^$5-6/. Under SSFP, in addition of FID, spin echo and stimulated echo are also generated, so the acquired signal is increased. The signal intensity is increased depending on flip angle (FA) of magnetized spin. This phenomenon is confirmed by human brain and phantom studies. The performance of this method is quantitatively analyzed by using both of conventional spin echo DWI and 3D-DWI. From experimental results, three dimensional diffusion weighted images are obtained correctly for liquid phantoms (water, acetone and oil), diffusion coefficient is enhanced in each image. Therefore, this method will provide useful information for clinical diagnosis.

  • PDF

Removal of arsenic from aqueous phase using magnetized activated carbon and magnetic separation

  • Kwon, H.W.;Shin, T.C.;Kim, J.J.;Ha, D.W.;Kim, Min Gyu;Kim, Young-Hun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.20 no.2
    • /
    • pp.1-5
    • /
    • 2018
  • Arsenic (As) is one of the elements having most harmful impact on the human health. Arsenic is a known carcinogen and arsenic contamination of drinking water is affecting on humans in many regions of the world. Adsorption has been proved most preferable technique for the removal of arsenic. Many researchers have studied various types of solid materials as arsenic adsorbent, and iron oxide and its modified forms are considered as the most effective adsorbent in terms of adsorption capacity, recovery, and economics. However, most of all iron oxides have small surface area in comparing with common adsorbents in environmental application such as activated carbon but the activated carbon has weak sorption affinity for arsenic. We have used an activated carbon as base adsorbent and iron oxide coating on the activated carbon as high affinity sorption sites and giving magnetic attraction ability. In this study, adsorption properties of arsenic and magnetic separation efficiency of the magnetized activated carbon (MAC) were evaluated with variable iron oxide content. As the iron oxide content of the MAC increased, adsorption capacity has also gradually increased up to a point where clogging by iron oxide in the pore of activated carbon compensate the increased sorption capacity. The increase of iron oxide content of the MAC also affected magnetic properties, which resulted in greater magnetic separation efficiency. Current results show that magnetically modified common adsorbent can be an efficiency improved adsorbent and a feasible environmental process if it is combined with the magnetic separation.

Four months of magnetized water supplementation improves glycemic control, antioxidant status, and cellualr DNA damage in db/db mice (제2형 당뇨 모델 db/db 마우스에서 4개월의 자화수 섭취 후 혈당, 항산화 상태 및 세포 DNA 손상 개선 효과)

  • Lee, Hye-Jin;Kang, Myung-Hee
    • Journal of Nutrition and Health
    • /
    • v.49 no.6
    • /
    • pp.401-410
    • /
    • 2016
  • Purpose: Water is magnetically charged upon contact with a magnet. Although magnetic water products have been promoted since the 1930's, they have not received wide acceptance since their effectiveness is still in question; however, some have reported their therapeutic effects on the body, especially the digestive, nervous, and urinary systems. Methods: In this study, the effect of magnetized water on glycemic control of 14 diabetic mice (CB57BK/KsJ-db/db) in comparison with 10 control mice (CB57BK/KsJ-db/+(db/+)) was investigated. Seven diabetic control (DMC) mice and seven diabetic mice + magnetized water (DM+MW) were kept for 16 weeks, followed by intraperitoneal glucose tolerance test (IPGTT). Weekly blood glucose was measured from tail veins. Blood obtained from heart puncture was used for HbA1c analysis. Results: Blood glucose level showed a significant difference starting from the $10^{th}$ week of study ($496.1{\pm}10.2mg/dl$ in DMC vs. $437.9{\pm}76.9mg/dl$ in DM+MW). Blood glucose followed by IPGTT showed no significant difference between groups at 0, 30, 60, 90, and 120 min, although glucose level at 180 min was significantly reduced in DM+MW mice. Plasma insulin level in DM+MW groups was only 39.5% of that of DMC groups ($5.97{\pm}1.69ng/ml$ in DMC vs. $2.36{\pm}0.94ng/ml$ in DM+MW). Levels of HbA1c were 12.4% and 9.7% in DMC and DM+MW groups, respectively. Conclusion: These results show the promising therapeutic effect of magnetized water in regulating blood glucose homeostasis; however, long-term supplementation or mechanistic study is necessary.

Fundamental study on sustainable treatment system of mine water using magnetized solid catalyst

  • Mukuta, Chisato;Akiyama, Yoko
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.2
    • /
    • pp.15-21
    • /
    • 2019
  • In the mine exploration sites, sustainable treatment system of mine water with energy saving and minimized chemical additives is required. Since most of the mine water contains highly-concentrated ferrous ion, it is necessary to study on the removal method of iron ions. We propose the system consisting of two processes; precipitation process by air oxidation using solid catalyst-modified magnetite and separation process combining gravitational sedimentation and magnetic separation using a permanent magnet. Firstly, in the precipitation process (a former process of the system), we succeeded to prepare solid catalyst-modified magnetite. Air oxidation using solid catalyst-modified magnetite using $Fe_2(SO_4)_3$ as a starting material showed high iron removal capability. Secondly, in the separation process (latter process of the system), solid catalyst-modified magnetite using $Fe_2(SO_4)_3$ as a starting material can be separated by a superconducting bulk magnet and a permanent magnet.

Application of Superconducting Magnetic Separation for Condenser Water Treatment in Thermal Power Plant

  • Lee, You-Jin;Kwon, Jun-Mo;Baik, Seung-Kyu;Han, Kwang-Soo;Ko, Rock-Kil;Sohn, Myung-Hwan;Ha, Dong-Woo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.2
    • /
    • pp.21-24
    • /
    • 2011
  • Superconducting high gradient magnetic separation (HGMS) has advantages to treat wastewater because it can generate high magnetic field and achieve rapid purification. In this study superconducting HGMS was applied to remove impurities from the condenser water in thermal power plant. The condenser water contained mainly hematite and maghemite and it was highly magnetized than hematite. In the HGMS tests using a 6-T cryo-cooled Nb-Ti superconducting magnet, the turbidity of the condenser water was effectively reduced up to 99.6% and the result showed better performance than that of the 0.5-T permanent magnet test. The higher magnetic field was applied in the range of 1-6T, the more iron oxides were removed. The effect of magnetic filter configuration on the condenser water treatment was also investigated. Consequently superconducting HGMS system can be applicable to remove iron oxide impurities from condenser water in thermal power plant.

Study on magnetic separation of waste water using superconducting magnet (초전도 전자석을 이용한 제철소 폐수처리용 자기분리 연구)

  • Ha, Dong-Woo;Kim, Tae-Hyung;Oh, Sang-Soo;Ha, Hong-Soo;Park, Sung-Kook;Lee, Sang-Gil;Roh, Yu-Mi
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.87-88
    • /
    • 2006
  • It is needed several large reservoirs and long time in order to remove suspended solid like steel fines and iron oxide at steel making factory. If removing rate of suspended solid in rolling coolant is improved, the productivity of working process can be increased and the area of reservoir can be reduced. Pre-treatment to add extra magnetization of suspended solid was studied Iron hydroxide and electrolytic dissociation were used for pretreatment. High gradient magnetic separation (HGMS) system was used for removing of magnetized suspended solid. Removing ratio showed over than 99% in the coolant containing magnetic fines. Magnetic properties of suspended solid were investigated after mixed with Al2(SO2)3 and organic flocculant by using electrochemical treatment.

  • PDF

Development of the active magnetic regenerative refrigerator for room temperature application (상온 능동형 자기 재생 냉동기의 개발)

  • Park, I.;Kim, Y.;Jeong, S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.3
    • /
    • pp.60-64
    • /
    • 2012
  • In this paper, an investigation of a room temperature active magnetic regenerative refrigerator is carried out. Experimental apparatus includes two active magnetic regenerators containing 186 g of Gd spheres. Four E-type thermocouples are installed inside the Active magnetic regenerator(AMR) to observe the instantaneous temperature variation of AMR. Both warm and cold heat exchangers are designed for large temperature span. The cold heat exchanger, which separates the two AMRs, employs a copper tube with length of 80 mm and diameter of 6.35 mm. In order to minimize dead volume between the warm heat exchanger and AMRs, the warm heat exchangers are located close to the AMRs. The deionized water is used as a heat transfer fluid, and maximum 1.4 T magnetic field is supplied by Halbach array of permanent magnets. The AMR plate, which contains the warm and the cold heat exchangers and the AMRs, has reciprocating motion using a linear actuator and each AMR is alternatively magnetized and demagnetized by a Halbach array of permanent magnet. Since the gap of the Halbach array of permanent magnets is 25 mm and two warm heat exchangers have the motion through it, a compact printed circuit heat exchanger (PCHE) is used as a warm heat exchanger. A maximum no-load temperature span of 26.8 K and a maximum cooling power of 33 W are obtained from the fabricated Active Magnetic Regenerative Refrigerator (AMRR).