Annealing Effect of Permeability Spectra in Amorphous Fe83Zr7B8Cu2

  • Kim, C.G.;Ryu, G.H.;Yu, S.C.;Moon, Y.M.;H.K. Lachowicz
    • Journal of Magnetics
    • /
    • v.3 no.2
    • /
    • pp.41-43
    • /
    • 1998
  • The frequency spectra of complex permeability have been measured as a function of ac field amplitude in the annealed amorphous $Fe_{83}Zr_7B_8Cu_2 $ ribbons. The longitudinal permeability results from the rotational magnetization at small fields, $h_o$<5 mOe in as-quenched samples. However, at the further increase of ho, the wall motion begins to be involved in the low frequency region. The permeability from the wall motion drastically decreases in the annealed sample, while that from the rotational magnetization increases up to annealing temperature of 50$0^{\circ}C$ and then drops there after.

  • PDF

Efficient Methodology for Reliability Assessment of Electromagnetic Devices Utilizing Accurate Surrogate Models Based on Dynamic Kriging Method

  • Kim, Dong-Wook;Jeung, Giwoo;Choi, K.K.;Kim, Heung-Geun;Kim, Dong-Hun
    • Journal of Magnetics
    • /
    • v.17 no.4
    • /
    • pp.291-297
    • /
    • 2012
  • This paper presents an efficient methodology for accurate reliability assessment of electromagnetic devices. To achieve the goal, elaborate surrogated models to approximate constraint functions of interest are generated based on the dynamic Kriging method and a hypercube local window. Then, the Monte Carlo simulation scheme is applied to the surrogate models. This leads to reducing computational cost dramatically without degrading accuracy of the reliability analysis. The validity of the proposed method is tested and examined with a mathematical example and a loudspeaker design.

Analysis of Electroencephalogram and Electrocardiogram at an Acupoint PC9 during Pulsed Magnetic Field Stimulus

  • Lee, Jin-Yong;Hwang, Do-Gwen;Yoo, Jun-Sang;Lee, Hyun-Sook
    • Journal of Magnetics
    • /
    • v.17 no.2
    • /
    • pp.133-137
    • /
    • 2012
  • We investigated the effects of pulsed magnetic fields (PMF) stimulus on electroencephalogram (EEG) alpha activity and heart rate variability (HRV) from electrocardiogram (ECG) measurements with various stimulus durations at acupoint PC9. The alpha activity in the EEG and the ratio of low frequency power and high frequency power (LHR) in the HRV, a reflection of sympathovagal activity, were increased and decreased, respectively, after PMF stimulus of 3 min. Our spectral analysis quantitatively proved that the changes in the EEG alpha activity were consistent with an autonomic function in the ECG. These findings suggest that appropriate PMF stimulus results in the same effect as that of acupuncture applied to the acupoint PC9, which is closely related to the parasympathetic activity of the autonomic nervous system.

New Macroscopic Ferrimagnets in the System Co-TbN

  • Kim, Tae-Wan;Oh, Jung-Keun
    • Journal of Magnetics
    • /
    • v.13 no.1
    • /
    • pp.11-18
    • /
    • 2008
  • This study examines a new macroscopic ferrimagnet, Co-TbN. This ferrimagnet, consisting of two metallic phases, Co and TbN, demonstrated the typical macroscopic ferrimagnet properties of a magnetic compensation point and a negative giant magnetoresistance (GMR). The Co-TbN system with 32% TbN composition showed 0.72% GMR in magnetic fields up to 8 kOe at room temperature and 9% GMR in 40 kOe at 250 K. In the Co-TbN system, GMR exhibited a different dependence on temperature from that of ordinary GMR materials whose negative magnetoresistance decreases with increasing temperature. In contrast to ordinary GMR materials whose negative magnetoresistance decreases with increasing temperature, the GMR effect in the Co-TbN system increased with increasing temperature, due to the increase of ferromagnetic alignment of the Co and TbN in the magnetic field caused by the decreased exchange coupling with increasing temperature.

Reliability-Based Design Optimization of a Superconducting Magnetic Energy Storage System (SMES) Utilizing Reliability Index Approach

  • Jeung, Gi-Woo;Kim, Dong-Wook;Sung, Young-Hwa;Kim, Heung-Geun;Kim, Dong-Hun
    • Journal of Magnetics
    • /
    • v.17 no.1
    • /
    • pp.46-50
    • /
    • 2012
  • A reliability-based optimization method for electromagnetic design is presented to take uncertainties of design parameters into account. The method can provide an optimal design satisfying a specified confidence level in the presence of uncertain parameters. To achieve the goal, the reliability index approach based on the firstorder reliability method is adopted to deal with probabilistic constraint functions and a double-loop optimization algorithm is implemented to obtain an optimum. The proposed method is applied to the TEAM Workshop Problem 22 and its accuracy and efficiency is verified with reference of Monte Carlo simulation results.

Electron Spin Transition Line-width of Mn-doped Wurtzite GaN Film for the Quantum Limit

  • Park, Jung-Il;Lee, Hyeong-Rag;Lee, Su-Ho;Hyun, Dong-Geul
    • Journal of Magnetics
    • /
    • v.17 no.1
    • /
    • pp.13-18
    • /
    • 2012
  • Starting with Kubo's formula and using the projection operator technique introduced by Kawabata, EPR lineprofile function for a $Mn^{2+}$-doped wurtzite structure GaN semiconductor was derived as a function of temperature at a frequency of 9.49 GHz (X-band) in the presence of external electromagnetic field. The line-width is barely affected in the low-temperature region because there is no correlation between the resonance fields and the distribution function. At higher temperature the line-width increases with increasing temperature due to the interaction of electrons with acoustic phonons. Thus, the present technique is considered to be more convenient to explain the resonant system as in the case of other optical transition systems.

Anisotropy Coupling in Patterned Thin Films with Mixed Uniaxial Anisotropies

  • Nam, Yoon Jae;Lee, Tae Young;Lim, Sang Ho
    • Journal of Magnetics
    • /
    • v.19 no.3
    • /
    • pp.232-236
    • /
    • 2014
  • Anisotropy coupling in thin films with mixed induced and shape anisotropies is investigated. A 200-nm-thick Co-Fe-Pd-B thin film with a large induced anisotropy of 57 Oe is fabricated and then patterned into micron-sized cells to provide shape anisotropy, whose strength has a similar magnitude to that of the induced anisotropy for enhancing the anisotropy coupling. The angles between the two mixed anisotropies considered are $0^{\circ}$, $90^{\circ}$, and $110^{\circ}$. Hysteresis loops measured under in-plane magnetic fields along various directions indicate no anisotropy coupling behaviour for all the three angles examined in this study.

General Analytical Method for Magnetic Field Analysis of Halbach Magnet Arrays Based on Magnetic Scalar Potential

  • Jin, Ping;Yuan, Yue;Lin, Heyun;Fang, Shuhua;Ho, S.L.
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.95-104
    • /
    • 2013
  • This paper presents a general analytical method for predicting the magnetic fields of different Halbach magnet arrays with or without back iron mounted on slotless permanent magnet (PM) linear machines. By using Fourier decomposition, the magnetization components of four typical Halbach magnet arrays are determined. By applying special synthetic boundary conditions on the PM surfaces, the expressions of their magnetic field distributions are derived based on the magnetic scalar potential (MSP), which are simpler than those based on the magnetic vector potential (MVP). The correctness of the method is validated by finite element analysis. The harmonics of airgap flux density waveforms of these Halbach magnet arrays with or without back iron are also compared and optimized.

Annealing Effect of Local Anisotropy Field in Amorphous Co66Fe4Ni1B14Si15 Ribbon

  • Kim, C.G.;Jeong, M.H.;Jeong, M.H.;Yoon, S.S.;Yu, S.C.
    • Journal of Magnetics
    • /
    • v.3 no.4
    • /
    • pp.123-126
    • /
    • 1998
  • The magneto-impedance (MI) has been measured in the annealed Co66Fe4Ni1B14Si15 amorphous ribbon for the evaluation of anisotropy field. MI at the frequency of 10 MHz is related to the transverse permeability from rotational magnetization depending on the local anisotropy field. MI varies sensitively with the annealing temperature, reflecting the change of anisotropy field distribution. The local anisotropy fields evaluated from MI Profiles are discussed in terms of the magnetic softness and microstructural change by the annealing.

  • PDF

The Substitution Effect of Boron on Reentrant Behavior of Rapidly Solidified FeMnZr Alloys

  • Moon, Y.M;Kim, K.S;Yu, S.C;Srinivas, V
    • Journal of Magnetics
    • /
    • v.9 no.4
    • /
    • pp.113-115
    • /
    • 2004
  • The magnetization properties have been measured for amorphous $Fe_{82}Mn_{8-x}B_xZr_{10}$ (x = 0-8) alloys. The temperature dependence of magnetization for these alloys shows the existence of antiferromagnetic couplings between Fe atoms in low fields at low temperatures. The magnetic parameters, obtained from the magnetization behavior are consistent with the presence of mixed magnetic state. The Curie temperature and magnetic moment increased with an increase of the concentration of B and spin glass like transition observed at low temperature decreases and finally vanishes at x = 8 at %. Our result suggests that the substitution of B for Mn seems to cause an increase of magnetic order.