• Title/Summary/Keyword: magnetic-mount

Search Result 51, Processing Time 0.031 seconds

An Experimental Study on the Design Parameters of the Dashpot type MR fluid mount (대시포트형 MR유체 마운트의 설계 인자에 대한 실험적 고찰)

  • Park, Woo-Cheul;Kim, Il-Gyoum;Lee, Hyun-Chang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3567-3573
    • /
    • 2009
  • This research proposed a dashpot type mount design using MR fluids, and investigated experimentally the influence of the design parameters of the dashpot MR fluid mount, which affect the damping forces of the dashpot MR fluid mount. In order to observe the influence, the dashpot MR fluid mount which have the different effective length and the core structure is manufactured. The variations of the resistance forces according to different effective lengths of the magnetic pole of MR fluid mount, along which magnetic field is defined, was investigated. It was founded that the resistance forces from the MR mount decreased with increased input frequencies, while increased with increased applied electric current intensities. Nevertheless, there is no appreciable change in the resistance forces with respect to the effective length variations of the magnetic pole of MR fluid mount.

Age Dating of Seafloor by Interpretation of Geomagnetic Structure and Study on the Magnetic Basement of the Sea Mount (지자기 구조해석에 의한 해저년대의 측정과 해산의 자기기기반구조의 연구)

  • 신기철;한건모
    • Journal of Ocean Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.35-42
    • /
    • 1990
  • The area where age dating of the seafloor and interpretation of geomagnetic basic structure are conducted is also important in the aspect of geophysics. Near the sea mount (water depth to the top is 3900m and 6500m to the bottom), there are Mesozoic magnetic lineations at the sea-side flank along the trench axis. A two dimensional model analysis of Talwani and Heirtzler(1964) and a three dimensional model analysis of Talwani are performed by using data obtained from the marine proton magnetometer. Distribution, direction of the lineation, amplitude and period of magnetic anomaly are correlated and analysed with speed of the plate movement and lineation of the sea mount. In the west and north-west Pacific there are lots of huge sea mounts retaining the history of oceanic crust. This indicates that geomagnetic basis subsided into the oceanic crust and has interest in the aspects of the isostasy theory of the gravity.

  • PDF

A Modeling of a Variable-damping Mount Using MR Fluid (MR 유체를 이용한 가변 감쇠 마운트의 모델화)

  • Ahn, Young-Kong;Tsuchiya, Takashi;Yang, Bo-Suk;Morishita, Shin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1338-1343
    • /
    • 2000
  • This paper deals with an application of Magneto-Rheological (MR) fluid to a small size mount for precision equipment of automobiles. MR fluid is known as a class of functional fluids with controllable apparent viscosity of fluid by the applied magnetic field strength. A typical MR fluid is a suspension where pure iron particles of $1{\sim}20mm$ in diameter are dispersed in a liquid such as mineral oil or silicone oil, at the concentration of $20{\sim}40$ vol%. Electro magnetic coil is installed at the bottom of a variable-damping mount filled with MR fluid, and its performance was investigated experimentally. Furthermore, the properties of the MR Mount on experimental Study were explained analytically by mechanical model of the MR mount.

  • PDF

Design of Hybrid Mount to Naval Shipboard Considering Shock Resistance (내충격 성능을 고려한 함정용 하이브리드 마운트의 설계)

  • Jo, Hye-Young;Shin, Yun-Ho;Moon, Seok-Jun;Jung, Woo-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.102-107
    • /
    • 2012
  • In this study, the design procedure of hybrid active mount by an electro-magnetic actuator is proposed to reduce the transmitted force from naval shipboard equipment to ship hull structure. The hybrid type mount which is composed of a passive rubber element and an electro-magnetic actuator is introduced and, through the vibration measurement for the objective pump system, the required force of the actuator is computed and discussed in detail. The initial designs were supposed for three types, one is moving coil type actuator and the others are moving permanent magnet type actuators. Based on the initial design concept, the final designs considering shock resistance and interference with mover and stator are proposed and examined.

  • PDF

Dynamic Properties of Squeeze Type Mount Using MR Fluid (MR유체를 이용한 스퀴즈모드 타입 마운트의 동특성)

  • Ahn, Young-Kong;Yang, Bo-Suk;Ha, Jong-Yong;Kim, Dong-Jo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.349.1-349
    • /
    • 2002
  • This paper presents investigation of damping characteristics of squeeze mode type MR mount experimently. The MR mount proposed in the study has variable damping characteristics according to the applied magnetic field strength. Impact and force excitation tests were performed. The dynamic property of the mount using MR fluid was compared with that of the mount using conventional oil. (omitted)

  • PDF

Response Property of Multi-directional Mount Using Magneto-Rheological Fluid (MR유체를 이용한 다방향 제진형 마운트의 응답특성)

  • 안영공;신동춘;양보석;이일영;김동조
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.7
    • /
    • pp.517-523
    • /
    • 2003
  • This paper presents response property of the squeeze mode type mount using Magneto-Rheological fluid (MR fluid) . The MR mount for the isolation of multi-directional vibrations was constructed in this study. Both the mechanism and shape of the mount are the same as squeeze film dampers for a rotor system. In the present work, the performance of the mount was experimentally Investigated according to the magnetic field strength. The experimental results present that the MR mount can effectively reduce the vibration in a wide range of frequency by controlling the applied electromagnetic filed strength. Viscous damping and stiffness coefficients of the MR mount tend to be changed according to the variation of the applied currents In this study.

The Effect of Electromagnetic Fields Shielding on Electromagnetic Fields Decrease in P. T Room (차폐천이 물리치료실 환경내 전자기장 감소에 미치는 효과)

  • Lim Chang-Hun;Kim Jin-Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.12 no.2
    • /
    • pp.69-82
    • /
    • 2000
  • Physical therapists are exposured to radio-and microwave-frequency electromagnetic radiation by operating electrotherapy units. So there is few protection system in physical therapy room. Clinical pathology room and so on where various kins of electromagnetic instruments is used in hospital while protection failities like protection wall or protection glass is being used only in radiological room to reduce the damage of radiation. Acoording to Larsen's survey on female physical therapist in denmark. it was said that the percentage of congenital malfornation was $3.6\%$ and cadiac malformation made up $0.7\%$. It is likely that effect of electromagnetic fields on the result cannot be ruled out. Rita ouellet-Hellstron and Walter F. Steward insisted that the danger of abortion increase in the case of pregnant femeal physical therapist exposured to microwave diathermy. The intention of our study is arousing the necessity of microwave protection in P.T room and finding the proper method for physical therapist safe. The results of this study were as follows: 1. Each electrotherapy units are occurrenced the electromagnetic fields, and specially amply occurrenced in H.P,I.C.T 2 unit operating, M.W.D unit head on parallel, S.W.D unit head on parallel. all electrotherapy units are operating. 2. There were electric fields mount are consideration to species of electrotherapy units(p<.05). 3. There were magnetic fields mount are consideration to species of electrotherapy units(p<.05). 4. There were electric fields mount are consideration to distance of electrotherapy units(p<.05). 7. There were magnetic fields mount are consideration nut to distance of electrotherapy units(p>.05). 8. Before and after protection on magnetic fields mount are consideration to all distance(0m, 0.3m, 1m, 3m, 5m)(p<.05) 9. Before and after protection on electric fields mount are consideration to 0m, 1m, 3m distance(p<.05), and consideration not to 0.3m, 5m distance(p>.05) 10. After protection fellow the each electrotherapy units. distance, intencity to electromagnetic fields are reduced(p<.05).

  • PDF

STELLAR MAGNETIC ACTIVITY MEASURE BASED ON IUE MG II H+K EMISSION LINES OF MAIN-SEQUENCE G STARS

  • Kim, Dowoon;Choi, Hwajin;Yi, Yu
    • Journal of The Korean Astronomical Society
    • /
    • v.55 no.2
    • /
    • pp.59-66
    • /
    • 2022
  • Stellar magnetic activity is important for formulating the evolution of the star. To represent the stellar magnetic activity, the S index is defined using the Ca II H+K flux measure from the Mount Wilson Observatory. Mg II lines are generated in a manner similar to the formation of Ca II lines, which are more sensitive to weak chromospheric activity. Mg II flux data are available from the International Ultraviolet Explorer (IUE). Thus, the main purpose of this study was to analyze the magnetic activity of stars. We used 343 high-resolution IUE spectra of 14 main-sequence G stars to obtain the Mg II continuum surface flux and Mg II line-core flux around 2,800 Å. We calculated S index using the IUE spectra and compared it with the conventional Mount Wilson S index. We found a color (B - V ) dependent association between the S index and the Mg II emission line-core flux. Furthermore, we attempted to obtain the magnetic activity cycles of these stars based on the new S index. Unfortunately, this was not successful because the IUE observation interval of approximately 17 years is too short to estimate the magnetic activity cycles of G-type stars, whose cycles may be longer than the 11 year mean activity cycle of the sun.

Development of MR Mount for Vibration Control of Marine Diesel-Generator Set (박용 발전기세트 진동 제어용 MR 마운트 개발)

  • Kang, Ok-Hyun;Kim, Won-Hyun;Joo, Won Ho;Park, Jun-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.04a
    • /
    • pp.381-385
    • /
    • 2014
  • This paper investigates the magneto-rheological(MR) mount for the marine diesel-generator(D/G) sets. Sometimes, significant vibrations over the allowable limit are observed on the D/G sets due to their huge excitation forces. Because the severe vibration can lead to structural damages to the D/G sets, it should be reduced below the limit. Although passive mounts with rubber isolators are usually used, the vibration reduction performance is not always sufficient. In addition, expecting that the vibration levels required by customers will get more severe, vibration reduction devices need to be developed. To the aim, the flow mode type of MR mount has been designed. Especially, the annular-radial configuration was adopted to enhance the damping force within the restricted space. The geometry of the mount has been optimized to obtain the required damping force and the magnetic field analysis has been carried out using ANSYS APDL. To verify the performance of the developed MR mount, an excitation test was conducted. In addition, they were applied to a medium-speed diesel generator and it was verified that about 40% of vibration reduction was yielded.

  • PDF

Optimal Design of Magnetorheological Mount for Ship Engines : Maximum Damping Force (선박용 엔진 MR 마운트의 최적설계: 최대 댐핑력)

  • Park, Joon Hee;Phu, Do Xuan;Hung, Nguyen Quoc;Kang, Ok Hyun;Choi, Seung-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.273-278
    • /
    • 2013
  • This paper presents optimal design procedures of mount based on a magnetorheological (MR) fluid to isolate the vibration in heavy diesel engine system. At first, frequency response and force-displacement transmissibility methods are used to get required damping force that is necessary for effective vibration isolation. From this result, a new type of high damping force engine mount is proposed and the governing equation of Bingham plastic behavior of MR fluid in flow path is mathematically derived under cylindrical coordinates. Finally, parametric design optimization featuring finite element is performed using ANSYS software to get the required damping force in MR mount system which can be used to reduce engine vibration. Damping force of the MR mount is then determined as an objective function in this analysis based on ANSYS. Furthermore, Magnetic analysis is then applied in this process.

  • PDF