• Title/Summary/Keyword: magnetic treatment

Search Result 1,514, Processing Time 0.025 seconds

Application Status and Prospect of Magnetic Separation Technology for Wastewater Treatment (폐수처리 분야에서 자기 분리기술의 응용 현황 및 전망)

  • Chu, Shaoxiong;Lim, Bongsu;Choi, Chansoo
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.2
    • /
    • pp.153-163
    • /
    • 2020
  • Magnetic separation technology is an efficient and environmentally friendly technology. Compared with the traditional wastewater treatment technology, the magnetic separation technology has its unique advantages and characteristics, and has been widely applied in the field of wastewater treatment. In particular, the emergence of superconducting magnetic separation technology makes possible for high application potential and value. In this paper, which through consulting with the literatures of Korea, Chinese, United States and other countries, the magnetic separation technology applied to wastewater treatment was mainly divided into direct application of magnetic field, flocculation, adsorption, catalysis and separation coupling technology. Advantages and limitations of the magnetic separation technology in sewage treatment and its future development were also studied. Currently, magnetic separation technology needs to be studied for additional improvement in processing mechanism, design optimization of magnetic carrier and magnetic separator, and overcoming engineering application lag. The selection, optimization and manufacturing of cheap magnetic beads, highly adsorbed and easily desorbed magnetic beads, specific magnetic beads, nanocomposite magnetic beads and the research of magnetic beads recovery technology will be hot application of the magnetic separation technology based on the magnetic carriers in wastewater treatment. In order to further reduce the investment and operation costs and to promote the application of engineering, it is necessary to strengthen the research and development of high field strength using inexpensive and energy-saving magnet materials, specifically through design and development of new high efficiency magnetic separators/filters, magnetic separators and superconducting magnetic separators.

A Study on the Stress Relief by Pulse Magnetic Treatment (펄스 자기장을 이용한 잔류 응력 완화 연구)

  • Oh, Ju-Suk;Yang, Won-Jon;Lee, Jong-Hoon;Park, Yong-Ho
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.24 no.3
    • /
    • pp.149-155
    • /
    • 2011
  • Residual stress relief by pulse magnetic treatment is attractive because the process is carried out at room temperature and magnetic fields that are easy to produce and control can be used. This study shows that strong pulse magnetic treatment can lead to stress relaxation of structural steels instead of a conventional heat treatment process. And it makes a comparative study about pulse magnetic treatment and tempering by using Larson-Miller equation. When the specimen was subjected to a pulse magnetic treatment process the residual stress in the specimen was reduced by about 13.8%. It could be compared with tempering at $200^{\circ}C$ for 2hours by using thermal effect of Larson-Miller equation. As a result, it is considered that the pulsed magnetic treatment have an effect of the stress relation by tempering at $200^{\circ}C$ for 2 hours.

The Effect of Acupuncture with Magnetic Ring on Pain Threshold Using Algometer (자기장을 통한 침자극이 압통 역치에 미치는 영향)

  • Lee, Jong-Hoon;Min, Byung-Il;Hwang, Byung-Gil;Jang, Jin;Hong, Mu-Chang
    • Journal of Acupuncture Research
    • /
    • v.19 no.3
    • /
    • pp.77-87
    • /
    • 2002
  • Like acupuncture, magnetic therapy has been known to yield effectiveness when it is applied to relieve from fatigue, musculoskelectal diseases, sore sites, rheumatic arthritis and chronic pain syndromes. However, combined application of acupuncture and magnet has not yet been studied. This study is designed to investigate effectiveness of acupuncture therapy when in the magnetic field for the pain relief. Magnetic field was made by magnetic ring ($7{\psi}{\times}2.3{\psi}{\times}1.5mm$). Twenty-one male swimmers with latent muscular pain at the GB21 area in the university course of physical education in Daegu were chosen and divided into three groups; 1) acupuncture treatment group (n=7), 2) acupuncture treatment with iron ring group (n=7), 3) acupuncture treatment with magnetic ring group (n=7). Manual Acupuncture was given to the GB21 point for 20 minutes. The degree of pressure pain threshold (PPT, $kg/cm^2$) in GB21 was measured with algometer. Before acupuncture treatment, the PPT values were $6.08{\pm}1.69$, $6.39{\pm}1.72$ and $5.59{\pm}1.11$ in acupuncture treatment group, acupuncture treatment with iron ring group, acupuncture treatment with magnetic ring group, respectively. After acupuncture treatment, the PPT values were $6.48{\pm}2.33$, $6.31{\pm}1.31$ and $6.59{\pm}1.80$, respectively. Pressure threshold was significantly increased in the acupuncture treatment with magnetic ring group compared to the other groups. Based on these results, acupuncture treatment with magnetic ring produced better effects on pain threshold, and these effects can be considered to be associated with the currents or voltages induced by the acupuncture needle and magnetic ring at present.

  • PDF

Influence of Heat Treatment on Magnetic Chracteristics of the Magnetic (열처리방법이 철의 자기특성에 미치는 영향 1)

  • Kyung Hyon Tchah
    • 전기의세계
    • /
    • v.20 no.2
    • /
    • pp.15-18
    • /
    • 1971
  • Magnetic materials in relay have been found to change in their magnetic characteristics with heat treatment. This paper describes how the magnetic characteristics of Magnetic Iron are affected by heat treatment. The materials are pot annealed and cooled from high temperature in the pot, by exposing in the atmospheres, and by quenching in the water and oil. It also studies the best heating temperature and cooling method which improve the magnetic characteristics of the Magnetic Iron.

  • PDF

The Magnetic Treatment Method for Low-Observable Naval Vessel (해군함정의 영구자기장 감소를 위한 탈자기법)

  • Kim, Hwiseok;Lim, Seonho;Doh, Jaewon
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.4
    • /
    • pp.128-133
    • /
    • 2014
  • The control and reduction of the magnetization of naval vessel is important technologies for safety against torpedo and sea mine installed magnetic sensors. In general, we used to conduct as a magnetic treatment for permanent magnetization reduction and to compensate induced magnetization using on-board-degaussing system for the naval vessel's magnetic stealth. Navies have operated magnetic treatment facility in order to protect from sea mines. LIGNex1 Corp. has developed the magnetic treatment facility for the korea navy.

Design and embodiment of variableness band style magnetic field nerve stimulation system that apply $1^{trigger}$ $2^{mode}$ magnetic field treatment Probe for disease treatment

  • Kim, Whi-Young;Park, Sung-Joon
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.4
    • /
    • pp.411-416
    • /
    • 2008
  • When compose magnetic field curer by belt and band style and need by magnetic field ripple last month, produce self-discipline roof. Bred in muscle disease (lumbago, backbone disease, corpulence) back. Result that study, manufactured various variableness band style - magnetic field probe firstly. Can establish self-discipline treatment pulse price by disease secondly. Could seek correct variableness band punishment, - magnetic field probe relationship implementation and property in waist, and so on, shoulder, neck, arm, leg, ankle, wrist etc. by third. Could find variableness band style energy value that need in-magnetic field Probe's treatment by fourth. This research could design pulse of self-discipline in band form and apply each according to disease.

Study on Magnetic Property Enhancement of Metal Powders for Magnetic Tape by Using Ultrasonic Dispersion (자기테이프용 Metal Powder의 초음파 분산에 의한 자기적 특성 향상에 관한 연구)

  • Kim, Chang-Gon;Choe, Hyeon-Seung;Jang, Hak-Jin;Yun, Seok-Yeong;Kim, Tae-Ok
    • Korean Journal of Materials Research
    • /
    • v.11 no.11
    • /
    • pp.972-977
    • /
    • 2001
  • It was investigated the effect of ultrasonic treatment on magnetic property of ultra fine magnetic Fe powders ($\alpha$-Fe) for magnetic tape. The properties were characterized with vibrating sample magnetometer (VSM), particle size analyzer (PSA) and scanning electron microscope (SEM). At 4hours ultrasonic treatment of 70 kHz, magnetic properties such as squareness ratio (S.Q. : 0.8868), orientation ratio (O.R. : 2.45) and switching field distribution (S.F. D. : 0.394) before taping were relatively enhanced. Cumulative particle size distribution of less than 5$\mu\textrm{m}$ fine powder was above 90% below 1 hour leaving time after ultrasonic treatment and it was supposed that ultrasonic treatment prevent aggregation. The magnetic values of S.Q. and S.F.D. of tape manufactured at 70 kHz and 4hour ultrasonic treatment were improved from 0.7747, 0.3818 to 0.8037, 0.3706, respectively. Electro-magnetic property used as in-output signal characteristic was improved, which showed that ultrasonic treatment developed the magnetic properties.

  • PDF

Measurement of Magnetic Flux and Induced Current in Magnetic Stimulation for Urinary Incontinence Treatment (요실금 치료용 자기 자극기의 자속밀도 및 유도전류 측정)

  • Han, Byung-Hee;Choi, Kyung-Moo;Cho, Min-Hyoung;Lee, Soo-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.4
    • /
    • pp.318-326
    • /
    • 2009
  • A simple method for measuring magnetic flux and induced current in magnetic nerve stimulation for urinary incontinence treatment is proposed. Unlike electric nerve stimulation, direct measurement of the induced current in magnetic nerve stimulation is impossible. Since induced currents stimulate nerves or muscles in magnetic nerve stimulation, measuring induced current is very important in validating stimulation efficacy and securing safety. The magnetic flux measuring system is composed of 6 layers with pick-up coils of 7 by 7 in each layer, and the induced current measuring system is composed of 6 layers with 7 concentric circular coils in each layer. The proposed method can be used in the design or performance test of a magnetic nerve stimulator for many clinical applications such as urinary incontinence treatment, activation of peripheral nerves, and transcranial magnetic stimulation.

Application of magnetic activated sludge process for a milking parlor wastewater treatment with nitrogen and phosphorus recovery

  • Onodera, Toshihito;Sakai, Yasuzo;Kashiwazaki, Masaru;Ihara, Ikko;Lal, Saha Mihir
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.3
    • /
    • pp.20-25
    • /
    • 2021
  • Milking parlor wastewater contains high concentration suspended solid (SS), nitrogen, and/or phosphate as well as organic compounds. A new biological wastewater process by magnetic separation, magnetic activated sludge (MAS) process, was applied to milking parlor wastewater treatment process. A three step wastewater treatment process of coagulation sedimentation / ammonia stripping (C/S), magnetic activated sludge process and contact oxidation (CO) was proposed for removal of these pollutants. First step, C/S process recovered 96% TN and 96% PO43--P as resource for fertilizer from the wastewater. 81% biochemical oxygen demand (BOD) in wastewater was removed after MAS process. As a results, all pollutant concentrations satisfied Japanese effluent standards. Most of residual BOD and SS were removed by the CO process. It was estimated that the proposed process could reduce the process space to 1/7.

Influence of Post-Sintering Annealing Conditions on the Microstructure and Magnetic Properties of Nd-Fe-B Magnet (Nd-Fe-B 소결자석의 소결 후 열처리 조건에 따른 미세조직 및 자기적 특성 변화)

  • Yunjong Jung;Soonjik Hong;Dong-Hwan Kim;Kyoung-Hoon Bae;Gian Song
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.37 no.1
    • /
    • pp.9-15
    • /
    • 2024
  • Nd-Fe-B permanent magnets have been utilized on various industrial fields such as electric vehicles, generator, robots with actuator, etc, due to their outstanding magnetic properties even 10 times better than conventional magnets. Recently, there are many researches that report magnetic properties improved by controlling microstructure through adjusting alloying elements or conducting various processing. Especially, post-sintering annealing (PSA) can significantly improve the coercivity by modifying the distribution and morphology of Nd-rich phase which formed at grain boundaries. In this study, Nd-Fe-B sintered magnets were subjected to primary heat treatment followed by secondary heat treatment at 460℃, 500℃, and 540℃ to investigate the changes in microstructure and magnetic properties with the secondary heat treatment temperature. EBSD analysis was conducted to compare anisotropic characteristics. Through the SEM and TEM observation for analyzing the morphology and distribution of Nd-rich phase, we investigated the relationship between microstructure and magnetic properties of sintered Nd-Fe-B magnets.