• Title/Summary/Keyword: magnetic switch

Search Result 171, Processing Time 0.031 seconds

A study on the optical switch using magnetic behavior of magnetic fluids (자성유체의 자기적 거동특성을 이용한 광 스위치에 관한 연구)

  • Choi, Bum-Kyoo;Oh, Jae-Geun;Kim, Do-Hyung;Song, Kwan-Min
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.16-21
    • /
    • 2005
  • This paper presents the development of the optical switch using magnetic behavior of magnetic fluids, which is expected to be used broadly in high-speed information communication. The magnetic fluids for switching an incident light, have the magnetic characteristics of magnetic materials and fluidity of liquids, simultaneously. The relations are derived between the intensity of magnetic field and the angle of optical fiber which is bent by a behavior of magnetic fluid when the magnetic field is applied. When optical switch is implemented by the movement of liquid using magnetic fluid, the existing problem of durability for optical switch will be improved. Thus, this study shows the feasibility of the application for the optical switches using magnetic fluids.

Magnetic Switch Auto Control Method of the High-Voltage Pulse Power Supply (고전압 펄스 전원장치용 자기스위치 자동제어 방법)

  • Kim, Soo-Hong;Lee, Jeong-Hum;Kim, Byong-Seob;Kwon, Byung-Ki;Choi, Chang-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.366-373
    • /
    • 2011
  • The magnetic switch used in pulsed-power applications is superior in its high repetition rate, high stability, and long lifetime. But magnetic switch was optimized switching operation by manual control. When the load changes, the switching state can not be optimized automatically. In this paper, the auto control method of magnetic switch for high pulsed-power proposed. The magnetic switch is used capacitor charging power supply for high-voltage compressor. The proposed method can be optimized an efficiency of the system by magnetic switch auto control according to load variation. And the proposed method verify the experimental results.

Development of Mini Magnetic Switch (초소형 전자 개폐기 개발)

  • Lee, Kyung-Ku;Kim, Jun-Ho;Kim, Gyeoo-Mook;Park, Ji-Hong;Jo, Hyun-Kil;Ahan, Kil-Young;Seo, Jung-Min
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.134-136
    • /
    • 2003
  • This paper proposes moving mechanism theory & magnetic core analysis regarding mini magnetic contactor and differential mechanism & bimetal analysis regarding mini thermal overload relay. In shortage of technique, we have experienced many difficulties in magnetic switch development. By this research, we developed core parts about mini magnetic switch and applied the results to optimum mini magnetic switch development

  • PDF

The Operating Characteristic Analysis of PM-type MAGNETIC CONTACTOR (영구자석형 전자접촉기의 동작특성 해석)

  • Cho, Hyun-Kil;Lee, Eun-Woong;Kim, Gil-Su;Kim, Il-Jung;Kim, Sung-Jong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.792-794
    • /
    • 2000
  • This paper describes the design and the analysis of electromagnetic system of Magnetic Switch using 2D parametric finite element method(EM-Pulse). Magnetic Switch is electrical equipment, which is widely used for switching on/off motors in industrial field. The transient state is simulated in order to calculate the response time of Magnetic Switch. The simulation is based upon a step-by-step integration of the electric circuit equations and the core movement. The contactor uses a permanent magnet for maintaining the closed state. The presented solution takes account of non-linear magnetic material property and spring force controlled by core position. The dynamic response of Magnetic Switch predicted by the simulation agrees closely with the required condition.

  • PDF

3 Stage 2 Switch Application for Transcranial Magnetic Stimulation

  • Ha, Dong-Ho;Kim, Whi-Young;Choi, Sun-Seob
    • Journal of Magnetics
    • /
    • v.16 no.3
    • /
    • pp.234-239
    • /
    • 2011
  • Transcranial magnetic stimulation utilizes the method of controlling applied time and changing pulse by output pulse through power density control for diagnosis purposes. Transcranial magnetic stimulation can also be used in cases where diagnosis and treatment are difficult since output pulse shape can be changed. As intensity, pulse range, and pulse shape of the stimulation pulse must be changed according to lesion, the existing sine wave-shaped stimulation treatment pulse poses limitations in achieving various treatments and diagnosis. This study actualized a new method of transcranial magnetic stimulation that applies a 3 Stage 2 Switch( power semiconductor 2EA) for controlling pulse repetition rate by achieving numerous switching control of stimulation coil. Intensity, pulse range, and pulse shape of output can be freely changed to transform various treatment pulses in order to overcome limitations in stimulation treatment presented by the previous sine wave pulse shape. The method of freely changing pulse range by using 3 Stage 2 Switch discharge method is proposed. Pulse shape, composed of various pulse ranges, was created by grafting PFN (Pulsed Forming Network) through AVR AT80S8535 one-chip microprocessor technology, and application in transcranial magnetic stimulation was achieved to study the output characteristics of stimulation treatment pulse according to delaying time of the trigger signal applied in section switch.

A Study on a Design of Magnetic Switch Using Thyristor (Thyristor를 병용한 전자개폐기의 설계에 관한 연구)

  • Jong Soo Woen;Hee Yung Hwang;Heung Ho Lee
    • 전기의세계
    • /
    • v.26 no.2
    • /
    • pp.72-77
    • /
    • 1977
  • This paper is devoted primarily to a study of magnetic switch which does not produce any harmful are during the switching period using triacs. The arc-eliminating method presented in this paper experimentally obtained the desired results, and also we executed numerical analysis by computer. This method will be greatly helpful for protecting contacts of magnetic switch in case of freuqent operation.

  • PDF

Designing Techniques of PM-type MAGNETIC CONTACTOR (영구자석형 전자접촉기의 설계기법)

  • Cho, Hyun-Kil;Lee, Eun-Woong;Kim, Kil-Su;Kim, Jun-Ho;Jeong, Jong-Ho;Lim, Su-Saeng
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.653-656
    • /
    • 2001
  • This paper describes the design and the analysis of permanent magnetic actuator "Magnetic Switch" using classical method and 2D finite element method. The classical method gives an outline of permanent magnet size and analysis is carried out by finite element method. Therefore we make use of the result in specific detail site of magnet. The transient state is simulated in order to calculate the response time of "Magnetic Switch". The simulation is based upon a step-by-step integration of the electric circuit equations and the tore movement. The contactor uses a permanent magnet for maintaining the closed state. The presented solution takes account of non-linear magnetic material property and spring force controlled by core position. The dynamic response of "Magnetic Switch" is predicted by the simulation agrees closely with the required condition.

  • PDF

A Study on Accelerated Life Tests for Magnetic Switch Used in Distribution System (배전선로에 사용되는 전자개폐기(Magnetic Switch)의 가속수명시험에 관한 연구)

  • Ryu, Haeng-Soo;Han, Gyu-Hwan;Kwon, Young-Il
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.536-540
    • /
    • 2002
  • In this paper, accelerated life test (ALT) models and procedures for Magnetic Switch (MS) are developed and applied to assure specified reliability of the products at development phase and guarantee the life of the products. Magnetic contactor that functions with over-current relay is called MS. Magnetic contactor closes and opens the motor load with ON/OFF switch of electronic contactor. It is also used for protecting and controlling the load. Magnetic contactor detects the over-current flow in the load with a over-current relay and disconnects the load by opening its control power. In this study, ALT models for MS are developed using the relationship between stresses and life characteristics of products. Using the ALT models, we performed life tests and analyzed the tests results. The proposed ALT models and procedures may be extended and applied to testing similar kinds of products to reduce test times and costs of the tests remarkably. Finally the results of this study will contribute to improving reliability of products and strengthening competitiveness of our products in world markets.

  • PDF

A study on Non-contacted Transmitter Switch for Vehicle (비 접촉식 차량용 Transmitter Switch에 관한 연구)

  • Ahn, Jong-Young;Kim, Young-Sub;Kim, Sung-Su;Hur, Kang-In
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.5
    • /
    • pp.245-249
    • /
    • 2010
  • Now normally using a contact method of vehicle Inhibitor Switch that is use direct voltage level signal. This method is good solution for signal deliverly. but The contacted method have a short lifetime because of deterioration of contact surface. so we suggest to non-contacted method using magnetic sensor. The magnetic sensor is used to non-contacted method that is solution for problem of contacted method. In this paper using that of magnetic sensor feature, so we applied to Vehicle Transmitter switch that of non-contacting method. Sensor voltage outputs have variable electric potential that normally 0 mV to 150 mV, and it is depend on Switch Angle. we used two differential sin wave for switching of 5 state signal.