• 제목/요약/키워드: magnetic hysteresis loss

검색결과 73건 처리시간 0.034초

Iron Loss Analysis Considering Excitation Conditions Under Alternating Magnetic Fields

  • Hong, Sun-Ki;Koh, Chang-Seop
    • 조명전기설비학회논문지
    • /
    • 제24권3호
    • /
    • pp.33-38
    • /
    • 2010
  • In this paper, the nature of iron loss in electrical steel during alternating field excitation is investigated more precisely. The exact definition of AC iron loss is cleared by accurately measuring the iron loss for conditions of both the sinusoidal magnetic field and sinusoidal magnetic flux density. The results of this approach to iron loss calculations in electrical steel are compared to experimentally-measured losses. In addition, an inverse hysteresis model considering eddy current loss was developed to analyze the iron loss when the input is the voltage source. With this model, the inrush current in the inductor or transformer as well as the iron loss can be calculated.

유한 요소법과 이차원 텐서를 이용한 회전자계의 특성 해석 (Analysis of the Rotational Magnetic Field using the FEM and the 2-Dimensional Permeability Tensor)

  • 이창환;김홍규;정현교;홍선기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.169-171
    • /
    • 1996
  • Recently, the finite element analysis(FEM) using two dimensional magnetic permeability tensor was introduced to calculate the magnetic field considering the rotational hysteresis. We obtain the tensor matrix from the measured data using two-dimensional magnetic measuring apparatus. We calculate the induced magnetic flux density and the rotational hysteresis loss under the model with the same condition with the measuring apparatus. Therefore we show that FEM with tensor can be used to calculate the magnetic flux density and the rotational hysteresis loss in the arbitrary rotational magnetic field.

  • PDF

Practical Calculation of Iron Loss for Cylindrical Linear Machine

  • Jeong, Sung-In
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.1901-1907
    • /
    • 2018
  • This paper is a study for accurate iron loss calculation of a cylindrical linear machine for free piston engine. This study presents that it is possible to accurately predict power loss in ferromagnetic laminations under magnetic flux by specially considering the dependence of hysteresis, classical, and excess loss components on the magnetic induction derivative. Significant iron loss in the armature core will not only compromise the machine efficiency, but may also result in excessive heating, which could lead to irreversible deterioration in the machine performance. Thus, correct prediction of power losses under a distorted flux waveform is therefore an important prerequisite to machine design, particularly when dealing with large apparatus where stringent efficiency standards are required. Finally, it will be discussed about the iron loss in various materials of cylindrical linear electric machine by geometric and electrical parameters. It will give elaborate information about the perfect design and design rules of cylindrical linear machine and in parallel tools for the calculation, simulation and design will be available.

제조공정에 따른 Mn-Zn 페라이트의 전자기적 특성변화 (The Effect of the Processing Conditions on the Magnetics Properties of Mn-Zn ferrite)

  • 김종령;이해연;김현식;오영우;민복기
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.905-908
    • /
    • 2001
  • The microstructure and the magnetic properties of Mn-Zn ferrite, which were power loss and saturation magnetic flux density, were investigated as the function of the process before firing. The highest initial permeability and the lowest power loss were attained to the specimen with CaO 400 ppm as a resulted from the highest solubility to SiO$_2$and the creation of liquid phase which improved sintering. The biggest grain size, the highest saturation magnetic flux density and the lowest power loss, which was resulted from that the eddy current loss increased as grain size increased but the hysteresis loss much more decreased and the hysteresis loss strongly influenced on the total power loss rather than the eddy current loss, were obtained to the Mn-Zn ferrite added 2wt% PVA. The power loss was lowest and the saturation magnetic flux density was highest in case of 1 ton/$\textrm{cm}^2$ and the grain size was not influenced.

  • PDF

지중전력 케이블에 근접한 지지물의 철손에 관한 연구 (A Study Iron Losses On the Cable Racks adjacent to Under Ground Power Cable)

  • 전승구;김기흥
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제10권3호
    • /
    • pp.71-77
    • /
    • 1996
  • 본 연구는 지중전력 케이블 주변의 자성체로 이루어지는 구조물의 철손에 대해서 연구하였다. 케이블 지지대의 재질은 Fe, FRP, SUS로 바꾸어 Epatein법에 의해서 철손을 측정하여 Hysteresis손을 각각 비교계산하였다. 이 결과는 공급전압이 일정하면 Hysteresis손은 주파수의 0.6승에 반비례하였고, 최대자속밀도를 일정하게하고, 주파수를 60[Hz]에서 50[Hz]로 변경하던 철손은 약 0.806배가 되었다. Fe의 경우, Hysteresis 손은 전체손실의 약 70[%]이상 되었으며 "Loss program"을 이용하여 계산한 결과 SUS가 Fe보다 약 90[%]이상 철손이 감소하였고 계산결과도 SUS, FRP는 "0"에 가까웠다."0"에 가까웠다.ot;에 가까웠다.

  • PDF

Effects of Crystal Grain Size and Particle Size on Core Loss For Fe-Si Compressed Cores

  • Takemoto, Satoshi;Saito, Takanobu
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.1183-1184
    • /
    • 2006
  • Core loss of soft magnetic powder cores have been focused on to achieve high efficiency of power supplies. In this study the effects of crystal grain size on core loss were investigated by changing heat treatment conditions. It was found that core loss is influenced by crystal grain size because eddy current loss decreased and hysteresis loss increased by making crystal grain size smaller, and it is also influenced by particle size.

  • PDF

Core Loss Analysis of Non-oriented Electrical Steel Under Magnetic Induction Including Higher Harmonics

  • Cho, Chuhyun;Son, Derac;Cho, Youk
    • Journal of Magnetics
    • /
    • 제6권2호
    • /
    • pp.66-69
    • /
    • 2001
  • The actual magnetic induction waveform of cores in electrical machines is not sinusoidal i.e. higher harmonics are always included. Thus the core loss in actual electrical machines is different from the core loss which is measured by the standard method, because the waveform of magnetic induction should be sinusoidal in the standard testing method. Core loss analysis under higher harmonic induction is always important in electric machine design. In this works we measured the core loss when a hysteresis loop has only one period of an ac minor loop of higher harmonic frequency, depending on the position of the ac minor loop of relative to the fundamental harmonic frequency. From this experiment, the core loss P(B/sub 0/f/sub 0/, B/sub h/, nf/sub 0/)) under a higher harmonic magnetic induction B/sub h/ could be expressed by the linear combination the core loss at fundamental harmonic frequency P/sub c/(B/sub 0/, f/sub 0/), the core loss of ac minor loop at zero induction region of the major hysteresis loop P/sub cL/ (B/sub h/, nf/sub 0/), and the core loss of an ac minor loop in the high induction region of the major hysteresis loop P/sub cH/ (B/sub h/, nf/sub 0/) i.e., P/sub c/, (B/sub 0/, f/sub 0/, B/sub h/, nf/sub 0/)=P/sub c/ (B/sub 0/, f/sub 0/,)+(n-1)[k₁(B/sub 0/) P/sub cL/ (B/sub h/, nf/sub 0/)+(1-k₁(B/sub 0/)) P/sub cH/ (B/sub h/, nf/sub 0/)]. This will be useful formula for electrical machine designers and one of effective methods to predict core loss including higher harmonic induction.

  • PDF

와전류와 히스테리시스를 고려한 유도형 변위 센서의 자기회로 모델 개발 (A Magnetic Circuit Model of Inductive Sensor Considering Eddy Currents and Hysteresis)

  • 노명규;정민경;박병철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.267-270
    • /
    • 2002
  • The accuracy and the dynamic bandwidth are the two most important indices that an inductive position sensor is evaluated with. Eddy currents and magnetic hysteresis affect both of these performance indices. As the modulation frequency of the sensor increases to improve the dynamic bandwidth, the effects of eddy currents and hysteresis also increases, which results in the loss of accuracy. In this paper, a magnetic circuit model of the differential inductive sensor is developed. This model includes the effects of hysteresis and eddy currents. Experimental results confirm the validity of the model. The model predicts that the eddy current effects are not significant below the modulation frequency of 50kHz, as long as the lamination thickness is adequate.

  • PDF

Iron Loss Analysis of a Permanent Magnet Rotating Machine Taking Account of the Vector Hysteretic Properties of Electrical Steel Sheet

  • Yoon, Heesung;Jang, Seok-Myeong;Koh, Chang Seop
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권2호
    • /
    • pp.165-170
    • /
    • 2013
  • This paper presents the iron loss prediction of rotating electric machines taking account of the vector hysteretic properties of electrical steel sheet. The E&S vector hysteresis model is adopted to describe the vector hysteretic properties of a non-oriented electrical steel sheet, and incorporated into finite element analysis (FEA) for magnetic field analysis and iron loss prediction. A permanent magnet synchronous generator is taken as a numerical model, and the analyzed magnetic field distribution and predicted iron loss by using the proposed method is compared with those from a conventional method which employs an empirical iron loss formula with FEA based on a non-linear B-H curve. Through the comparison the effectiveness of the presented method for the iron loss prediction of the rotating machine is verified.

자기적 방법에 의한 0.85% 탄소강의 열처리에 따른 미세조직 및 기계적 성질 평가 (Evaluation of Microstructures and Mechanical Property of Variously Heat Treated 0.85% Carbon Steel by Magnetic Method)

  • 변재원;권숙인
    • 한국재료학회지
    • /
    • 제13권2호
    • /
    • pp.81-87
    • /
    • 2003
  • Microstructures and mechanical properties of variously heat treated 0.85% carbon steel(eutectoid steel) were evaluated by magnetic property measurements. Microstructural analysis (pearlite interstellar spacing), measurement of mechanical properties(Rockwell hardness, yield stress, fracture stress) and magnetic properties(coercivity, remanence, hysteresis loss, saturation magnetization) were performed to clarify mutual relationships among these parameters. Water quenched specimens with martensite structure showed much higher coercivity and remanence than air cooled or furnace cooled specimens with pearlite structure. The linear dependence of coercivity and remanence on pearlite interlamellar spacing as well as on Rockwell hardness, yield stress and fracture stress was observed in the pearlitic steel. Hysteresis loss and saturation magnetization showed no distinct trend with pearlite interlamellar spacing.