• 제목/요약/키워드: magnetic field source

검색결과 296건 처리시간 0.027초

Design and Implementation of Portable NMR Probe Magnet

  • Junxia, Gao;Yiming, Zhang;Jiashen, Tian
    • Journal of Magnetics
    • /
    • 제22권1호
    • /
    • pp.14-22
    • /
    • 2017
  • The NMR's probe consists of the static magnetic field generator (magnetic source) and the RF coil. It is very strict for the homogeneity of the static magnetic field intensity of the magnetic source, so the cost of the magnetic source is more expensive in the entire nuclear magnetic resonance instrument. The magnetic source generally consists of electromagnet, permanent magnet and superconducting magnet. The permanent magnet basically needs not to spend on operation and maintenance and its cost of manufacture is much cheaper than the superconducting magnet. Therefore, the permanent magnet may be the only choice for the static magnetic field device if we want to use the magnetic resonance instrument as an analyzer for production by reducing price. A new probe magnet was developed on the basis of the permanent magnet ring in this paper to provide a technological way for reducing the manufacturing cost, weight and volume of the existing nuclear magnetic resonance instrument (including MRI) probe.

생체 실험용 2-축(軸) 극저주파 자기장 발생 장치의 설계 (Design of 2-Axis Magnetic Field Source for in Vivo Experiments at Extremely Low Frequency)

  • 김정호;김윤명
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2003년도 종합학술발표회 논문집 Vol.13 No.1
    • /
    • pp.13-17
    • /
    • 2003
  • In this paper, the design parameters for the magnetic field source at extremely low frequency are proposed. This facility can be used for in vivo experiments with small animals to investigate biological response to the driving magnetic fields. In case that the exposed animals are motionless, the animals may be affected by the directivity of driving field. To avoid this effect, a 2-axis ELF magnetic field driving apparatus was designed, The optimum location and number of turns of each coil were obtained by numerical analysis. Applying these data to the MATLAB code (for computation), the magnetic field distribution was obtained. The calculation result for a well-designed facility showed that the space in which the amplitude of the magnetic field lies within the 95% of the magnetic field distribution was more than 60% of each axis length.

  • PDF

Quench characteristics of YBCO thin films using magnetic field source for superconducting fault current limiters

  • Lee, B.W.;Park, K.B.;Kang, J.S.;Oh, I.S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권2호
    • /
    • pp.11-14
    • /
    • 2004
  • YBCO thin films have good characteristics for current limiting materials due to compact size and high current carrying capability. But the irregularities and the extreme thin thickness of YBCO films cause some difficulties in simultaneous quench and thermal shock protection. In order to solve these problems, vertical magnetic field generated from solenoid coil was applied to the YBCO element. And also to minimize the inductance caused by the serial connection of magnetic field source with superconducting elements, magnetic field source was separated from the power lines adapting protective current transformer. In this study, electric field-current (E-I) and quench characteristics of YBCO films were analyzed both by electrical measuring method and observations of bubble propagation. From the experiment results, it was revealed that the magnetic fields generated by surrounding coil could induce the uniform quench distribution for all stripes of current limiting units and finally simultaneous quenches were realized in all serial connection of YBCO elements. In addition, the separation of magnetic field source form electrical network could be good solution for simultaneous quench of YBCO films without any unnecessary effect caused by serial connection.

Fabrication of a Circular Coil for the Study on the Magnetic Field Tolerance of TMP

  • Baik, Kyungmin;Cheung, Wan-Sup;Lim, Jong-Yeon
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.153-153
    • /
    • 2013
  • Turbomolecular pump (TMP) is widely used to obtain and maintain high vacuum by spinning turbine rotors to migrate gas molecules to the exhaust of the pump. However, performance of the TMP has not been well observed when it is influenced by strong magnetic field. Such study may give useful information about magnetic field tolerance of TMP, development of magnetic shielding technique for key components of TMP, etc. For this purpose, magnetic field induced by a circular current source was firstly designed and investigated. Using spherical coordinates and vector potential, magnetic field throughout the space including axis of rotation was calculated. Due to the rotational symmetry of the circular current source, induced magnetic field is azimuthally symmetric and, thus, is analyzed by radial and polar components of the magnetic fields. In order to enhance the numerical accuracy for the calculation, magnetic field was expressed by complete elliptic integrals of first and second kinds. According to the calculation, when 1 A of DC-current passes through a 1 turned circular wire with 50 cm of diameter, overall magnitude of the inducedmagnetic field was about 0.02 Gauss, which was used to the determination of the current and the number of turns of wires to fabricate the coil for the study on the magnetic field tolerance of TMP.

  • PDF

Comparative Study of Coupling Factors for Assessment of Low-Frequency Magnetic Field Exposure

  • Shim, Jae-Hoon;Choi, Min-Soo;Jung, Kyu-Jin;Kwon, Jong-Hwa;Byun, Jin-Kyu
    • Journal of Magnetics
    • /
    • 제21권4호
    • /
    • pp.516-523
    • /
    • 2016
  • In this paper, coupling factors are calculated based on numerical analysis in order to assess various non-uniform low-frequency magnetic field exposure situations. Two types of non-uniform magnetic field sources are considered; circular coil and parallel wires with balanced currents. For each magnetic field source, source current values are determined so that reference magnetic field magnitude can be measured at the specified point on the human model. Various exposure situations are investigated by changing parameters such as the distance between source and human model, radius of circular coil, and the gap between parallel wires. For equivalent human models, prolate spheroid model and simplified human model from IEC 62311 standard are used. The calculated coupling factor values are compared with those obtained by 2D uniform disk human model, and the dependence of coupling factor on the choice of equivalent human model is analyzed.

Formation of Crystalline Copper Thin Films by a Sputtering-assisted Magnetic Field System at Room Temperature

  • Kim, Hyun Sung
    • Applied Science and Convergence Technology
    • /
    • 제27권1호
    • /
    • pp.1-4
    • /
    • 2018
  • A sputtering-assisted magnetic field system was successfully developed for depositing crystalline Cu thin films at room temperature. This system employs a plasma source and an ion-beam gun with two magnetic field generators, which is covered with sputtering target and the ion-beam gun, simultaneously serving as sputtering plasma and a magnetic field generator. The formation of crystalline Cu thin films at room temperature was dominated by magnetic fields, which was revealed by preliminary experiments. This system can be employed for producing crystalline metal thin films at room temperature.

생체 실험용 극저주파 자기장 발생 장치의 설계 (Design of a Magnetic Field Source for In Vivo Experiments at Extremely Low Frequency)

  • 김정호;김윤명
    • 한국전자파학회논문지
    • /
    • 제14권8호
    • /
    • pp.871-877
    • /
    • 2003
  • 본 논문에서는 생체 실험용 극저주파 자기장 발생장치를 설계하였다. 생체실험 대상 동물이 유동적이지 않고 고정될 경우, 인가 자기장의 방향성에 대한 영향이 있을 수 있다. 이 방향성 영향을 줄이기 위해 2 축에 4개씩, 총 8개의 코일을 사용하여 2축 4중 Helmholtz 코일 구조의 장치를 설계하였다. 정육면체 구조의 자기장 발생 장치를 원통형으로 근사화시킨 수식을 유도하여, 원하는 특정 자기장을 위한 권선수 및 전류치를 계산하였으며, 각 코일의 최적 위치 및 최적 권선비는 수치계산을 통하여 구하였다. 이렇게 얻어진 수치들을 MATLAB 으로 제작한 계산 프로그램에 적용하여, 발생장치 주변에서의 자기장 분포를 계산 해보았으며, 공간에 따른 자기장 세기의 균일도를 평가하여 균일 자기장 분포영역 또는 생체 실험가능 영역을 도출하였다. 잘 설계된 장치의 해석 결과, 임의 기준 자기장에 대해 약 95 %의 균일도를 만족시키는 공간은 정육면체 구조에서 축길이의 60 % 이상이 됨을 확인하였다.

Study on magnetic field mapping within cylindrical center volume of general magnet

  • Huang, Li;Lee, Sangjin
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제18권2호
    • /
    • pp.30-36
    • /
    • 2016
  • For the magnetic field analysis or design, it is important to know the behavior of the magnetic field in an interesting space. Magnetic field mapping becomes a useful tool for the study of magnetic field. In this paper, a numerical way for mapping the magnetic field within the cylindrical center volume of magnet is presented, based on the solution of the Laplace's equation in the cylindrical coordinate system. The expression of the magnetic field can be obtained by the magnetic flux density, which measured in the mapped volume. According to the form of the expression, the measurement points are arranged with the parallel cylindrical line (PCL) method. As example, the magnetic flux density generated by an electron cyclotron resonance ion source (ECRIS) magnet and a quadrupole magnet were mapped using the PCL method, respectively. The mapping results show the PCL arrangement method is feasible and convenience to map the magnetic field within a cylindrical center volume generated by the general magnet.

헬리칼 공명 플라즈마에서 축 방향의 외부 자장이 기판상의 플라즈마 밀도에 미치는 영향 (Effects of axial external magnetic fields on plasma density on substrate in helical resonator plasma source)

  • 김태현;태흥식;이용현;이호준;이정해;최경철
    • 한국진공학회지
    • /
    • 제8권2호
    • /
    • pp.172-179
    • /
    • 1999
  • The axial distributions of plasma density in a helical resonator plasma with the external magnetic field have been measured using Langmuir probes. Net RF power is set to 200W and chamber pressure is varied from 0.4 mTorr to 100mTorr there are three kinds of eternal magnetic field structure applied on the helical resonator plasma. One is a uniform magnetic field, the second is a positive gradient magnetic field and the third is a negative gradient magnetic field. In the three magnetic field structures, the negative gradient magnetic field is found to show the highest increase in plasma density on the substrate compared with other magnetic structures. Plasma density profile in helical resonator is well consistent with electromagnetic field pattern obtained by computer simulation. It is also found that axial magnetic fields do not affect plasma density distribution in the plasma reactor region, but induce the increase of plasma density in the process chamber region. In order to avoid the nonuniformity of radial density profile, weak magnetic fields under 100G are applied.

  • PDF

Analysis of Solar Microwave Burst Spectrum, I. Nonuniform Magnetic Field

  • Lee, Jeongwoo
    • Journal of Astronomy and Space Sciences
    • /
    • 제35권4호
    • /
    • pp.211-218
    • /
    • 2018
  • Solar microwave bursts carry information about the magnetic field in the emitting region as well as about electrons accelerated during solar flares. While this sensitivity to the coronal magnetic field must be a unique advantage of solar microwave burst observations, it also adds a complexity to spectral analysis targeted to electron diagnostics. This paper introduces a new spectral analysis procedure in which the cross-section and thickness of a microwave source are expressed as power-law functions of the magnetic field so that the degree of magnetic inhomogeneity can systematically be derived. We applied this spectral analysis tool to two contrasting events observed by the Owens Valley Solar Array: the SOL2003-04-04T20:55 flare with a steep microwave spectrum and the SOL2003-10-19T16:50 flare with a broader spectrum. Our analysis shows that the strong flare with the broader microwave spectrum occurred in a region of highly inhomogeneous magnetic field and vice versa. We further demonstrate that such source properties are consistent with the magnetic field observations from the Michelson Doppler Imager instrument onboard the Solar and Heliospheric Observatory (SOHO) spacecraft and the extreme ultraviolet imaging observations from the SOHO extreme ultraviolet imaging telescope. This spectral inversion tool is particularly useful for analyzing microwave flux spectra of strong flares from magnetically complex systems.