• Title/Summary/Keyword: magnetic attachment

Search Result 77, Processing Time 0.022 seconds

A Comparative Study on the Retention of Implant Overdenture According to the Shape and the Number of Magnetic Attachment (자성 어태치먼트의 형태와 수에 따른 하악 임플란트 피개의치의 유지력에 대한 비교 연구)

  • Seo, Min-Ji;Lee, Joon-Seok;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.169-181
    • /
    • 2008
  • The aim of this study was to compare the retention and stability of implant overdenture according to the shape and the number of magnetic attachment. The experimental groups were designed for the number of implants(1, 2, 4) and shape of magnetic attachments(flat, cushion, dome type) resulting in 9 subgroups. 45 attachments were tested attached to $Br{\aa}nemark$ system implants which were planted on a mandibular model. Each attachment was composed of the magnet assembly embedded in a overdenture sample and the abutment keeper screwed into the implants. Dislodging tensile forces were applied to the overdenture samples using an Instron(cross-head speed 50.80mm/min) in 3 directions simulating function: vertical, oblique, and anterior-posterior. The loading was repeated 10 times in each direction for 45 samples. The values of maximum dislodging force of each subgroup were processed statistically using SPSS V. 12.0 at the 0.05 level of significance. The results of this study were as follows: 1. Flat type magnetic overdenture was the most retentive when subjected to vertically directed forces and dome type was the lest retentive when subjected to obliquely directed forces(p<0.05). 2. In case of planting one implant, flat type had a higher vertically retentive force than anterior-posteriorly retentive force. In case of planting two implants, flat type and dome type had a higher vertically retentive force and in case of planting four implants, flat type and cushion type had a higher vertically retentive force than anterior-posteriorly retentive force(p<0.05). 3. The incremental number of dental implant, without regards to the three types of magnetic attachment shapes, showed higher retention of overdenture(p<0.05). From the results, if a patient need much more retention of implant overdenture, flat type magnetic overdenture would be a good treatment. In case of the bruxism where excessive lateral forces are already present, dome type could be expected to produce better results. In case of planting one implant, flat type is more stable than the other shape of magnet and in case of two implant, flat type and dome type are more stable and in case of four implants, flat type and cushion type are more stable. Planting more than two implants and using flat type magnetic attachment would provide better retention and stability of implant overdenture

MRI findings of the antero-superior attachment of the disc in TMJ internal derangement (측두하악관절 내장증에서의 관절원판 전상방부착부의 자기공명영상)

  • Cho Bong-Hae;Jung Yun-Hoa
    • Imaging Science in Dentistry
    • /
    • v.36 no.2
    • /
    • pp.73-79
    • /
    • 2006
  • Purpose : To describe the MRI findings of the antero-superior attachment of the disc in patients with internal derangement. Materials and Methods : One hundred fifty-six MR images from 40 normal subjects and 55 abnormal subjects were classified into three study groups of normal, anterior disc displacement with reduction and anterior disc displacement without reduction. On both closed- and open-mouth proton density sagittal images, the depiction of the antero-superior attachment of the disc and its demarcation from the disc were evaluated in three cuts of lateral, central and medial one thirds of the condyle. Results : The depiction of antero-superior attachment was more frequent by the order of normal, anterior disc displacement with reduction and anterior disc displacement without reduction groups, and the significant differences were found on lateral cut of the closed images and lateral and central cuts of the open images. In study for the demarcation between the antero-superior attachment and the disc the lateral cut of the closed images and all three cuts of the open images showed significant differences. Conclusion : Open images are useful to show the difference in depiction of the antero-superior attachment of the disc among the TMJ groups.

  • PDF

Overdentures of the patient with Parkinson's disease: A case report (파킨슨 병을 가진 환자의 상악 마그네틱 피개의치 및 하악 임플란트 피개의치 수복 증례)

  • Min, Byung-Kwee;Shin, Eun-Jung;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Yun, Kwi-Dug;Lim, Hyun-Pil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.352-358
    • /
    • 2015
  • The retention of complete dentures in patients with Parkinson's disease is often poor due to their constant dislodgement by involuntary movements of the tongue and lips. Furthermore, insertion of the overdenture is expected to be difficult due to their limited voluntary movements. This case is about the bimaxillary overdenture restoration where its retention and stability are improved, using magnetic attachment of remained roots of maxilla and two implant $Locator^{(R)}$ attachments of mandible in patients with Parkinson's disease. This report describes the fabrication of this functionally improved prosthesis.

A STUDY ON THE CHANGES OF MR SIGNAL INTENSITY OF POSTERIOR ATTACHMENT OF THE TEMPOROMANDIBULAR JOINT (악관절 후방부착부에 있어서 MRI 신호변화에 대한 고찰)

  • Jung, Joo-Sung;Huh, Won-Shil;Chung, Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.19 no.1
    • /
    • pp.93-107
    • /
    • 1997
  • Magnetic resonance imaging has been used in the temporomandibular joint(TMJ) primarily to define morphology and positional relationship of associating structures. This report examines signal intensity characteristics of the posterior attachment as they related to the severity of internal derangement. Fifty six joints in 35 patients with a history of TMJ dysfunction were imaged writ MR using $T_1$-weighted spin echo sequence. According to disk position, ability to reduction, and the presence of osteoarthritis, the joints were categorized into three groups. A group 1 was anterior disk displacement with reduction; a group 2 was anterior disk displacement without reduction; a group 3 was anterior disk displacement without reduction and condyle had osteoarthritic change. The control group was determined by the clinical absence of any signs or symptoms of current or past TMJ pain and dysfunction. Calculated the relative value of MR signal intensity in posterior attachment and disk to cerebral cortex of temporal lobe by means of computer program, we have compared them with each groups. The result showed statistically little significant difference of disk signal intensity among each groups. but, signal intensity from posterior attachment in group 2 and 3 were significantly(p<0.05) decreased than control group. this might reflect an fibrosis or hyalinization of posterior attachment, which was part of remodeling process that occurs in disk displacement without reduction. However, this study could not demonstrate histologic confirmation of the decreased signal intensity in the posterior attachment. So, further investigation could be needed to understand the association between them.

  • PDF

Technical Trend of Multi-function for Nano-magnetic Material (다기능성 나노자성복합소재 기술동향)

  • Kim, Yu-Sang
    • Journal of the Korean institute of surface engineering
    • /
    • v.45 no.1
    • /
    • pp.43-52
    • /
    • 2012
  • Recently, it has been developed for Eco-environment, Super light, Multi-functional nano materials. As needed mobile parts in Smart phone or TV, computer, information communication for high pass signal, multi-function, Magnetic thin film materials have been developed. As last, magnetic powder, sintered and sputtering parts were thick and low purity than electroplating layer, low pass signal and noise were resulted, vibrated TV screen. Because chemical complex temperature was high and ununiform surface layer, it has been very difficult for data pass in High Frequency (GHz) area. Large capacity data pass is used to GHz. Above GHz, signal pass velocity is dependent on Skin Effect of surface layer. If surface layer is thick or ununiform, attachment is poor, low pass signal and cross talk, noise are produced and leaked. It has been reported technical trend of Electrochemically plating and Surface treatment of Metal, Polymer, Ceramic etc. by dispersion/complex for Multi functional nano-magnetic material in this paper.