• 제목/요약/키워드: macro fiber composite

검색결과 68건 처리시간 0.027초

Experimental Investigation on the Blast Resistance of Fiber-Reinforced Cementitious Composite Panels Subjected to Contact Explosions

  • Nam, Jeongsoo;Kim, Hongseop;Kim, Gyuyong
    • International Journal of Concrete Structures and Materials
    • /
    • 제11권1호
    • /
    • pp.29-43
    • /
    • 2017
  • This study investigates the blast resistance of fiber-reinforced cementitious composite (FRCC) panels, with fiber volume fractions of 2%, subjected to contact explosions using an emulsion explosive. A number of FRCC panels with five different fiber mixtures (i.e., micro polyvinyl alcohol fiber, micro polyethylene fiber, macro hooked-end steel fiber, micro polyvinyl alcohol fiber with macro hooked-end steel fiber, and micro polyethylene fiber with macro hooked-end steel fiber) were fabricated and tested. In addition, the blast resistance of plain panels (i.e., non-fiber-reinforced high strength concrete, and non-fiber-reinforced cementitious composites) were examined for comparison with those of the FRCC panels. The resistance of the panels to spall failure improved with the addition of micro synthetic fibers and/or macro hooked-end steel fibers as compared to those of the plain panels. The fracture energy of the FRCC panels was significantly higher than that of the plain panels, which reduced the local damage experienced by the FRCCs. The cracks on the back side of the micro synthetic fiber-reinforced panel due to contact explosions were greatly controlled compared to the macro hooked-end steel fiber-reinforced panel. However, the blast resistance of the macro hooked-end steel fiber-reinforced panel was improved by hybrid with micro synthetic fibers.

압전섬유작동기를 이용한 형상적응날개 (Morphing wing using Macro Fiber Composite actuator)

  • 나영호;김지환
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 춘계학술발표대회 논문집
    • /
    • pp.9-12
    • /
    • 2005
  • Recently, research on the morphing wing is an interesting issue to develop the capability of the wing such as improving the lift and reduction of drag during the operation of an aircraft by changing the wing shape from one configuration to another. A more efficient weight reduction of the wing using smart or morphing wing concept can be achieved in comparison with the conventional flaps. In this study, it is investigated the behaviors of the morphing wing using Macro Fiber Composite (MFC) actuators. Generally, MFC is the piezocomposite actuator with the rectangular PZT fiber and epoxy matrix, and uses the interdigitated electrode to produce more powerful actuation in the in-plane direction. Furthermore, it can produce the twisting actuation as compared with the traditional PZT actuators. In the formulation, the first-order shear deformation plate theory is used, and finite element method is adopted in the numerical analysis of the model. Results show the characteristics of the static behavior of the morphing wing according to the change of the actuation voltage.

  • PDF

Tension and impact behaviors of new type fiber reinforced concrete

  • Deng, Zongcai;Li, Jianhui
    • Computers and Concrete
    • /
    • 제4권1호
    • /
    • pp.19-32
    • /
    • 2007
  • This paper is concentrated on the behaviors of five different types of fiber reinforced concrete (FRC) in uniaxial tension and flexural impact. The complete stress-strain responses in tension were acquired through a systematic experimental program. It was found that the tensile peak strains of concrete with micro polyethylene (PEF) fiber are about 18-31% higher than that of matrix concrete, those for composite with macro polypropylene fiber is 40-83% higher than that of steel fiber reinforced concrete (SFRC). The fracture energy of composites with micro-fiber is 23-67% higher than that of matrix concrete; this for macro polypropylene fiber and steel fiber FRCs are about 150-210% and 270-320% larger than that of plain concrete respectively. Micro-fiber is more effective than macro-fiber for initial crack impact resistance; however, the failure impact resistance of macro-fiber is significantly larger than that of microfiber, especially macro-polypropylene-fiber.

수중에서 퍼넬형 macro fiber composite 에너지 하베스터의 에너지 수확 특성 (A study on the underwater energy harvesting characteristics of a funnel type macro fiber composite energy harvester)

  • 이종길;안진효
    • 한국음향학회지
    • /
    • 제42권1호
    • /
    • pp.57-66
    • /
    • 2023
  • 본 연구에서 제안한 에너지 하베스팅 장치는 입구가 넓고 출구가 좁은 퍼넬형 에너지 하베스터(Funnel Type Energy Harvester, FTEH)에 Macro Fiber Composite(MFC)가 외팔보 형태로 장착되어 있는 구조로서 MFC의 구조를 변화 시켰을 때 FTEH에 수확하는 에너지양의 특성을 이론과 실험을 통하여 분석하였다. MFC의 길이를 50 % 증가 시켰을 때 진동 변위는 3.5배 증가하였고, 두께를 75 % 감소시 30.9배 증가하였다. 수조 실험에서 최대 전력량은 스파이럴 스크루가 장착된 상태의 유연한 지지대에 수직으로 설치된 MFC가 스파이럴 스크루가 없고 견고한 지지대에 수평으로 설치된 경우보다 약 5배 정도 높았다. FTEH에 최적저항 4,010 kΩ을 적용하여 유속 0.24 m/s일 때 FTEH의 출력을 350 s 동안 커패시터에 에너지를 저장하면 4 ㎼·s에 도달하였다. 빠른 유속으로 유연한 지지대에 수직으로 설치된 대면적 MFC의 커패시터 충전 시간을 길게 하면 충전 에너지를 증가시킬 수 있음을 확인하였다.

Modeling techniques for active shape and vibration control of macro-fiber composite laminated structures

  • Zhang, Shun-Qi;Chen, Min;Zhao, Guo-Zhong;Wang, Zhan-Xi;Schmidt, Rudiger;Qin, Xian-Sheng
    • Smart Structures and Systems
    • /
    • 제19권6호
    • /
    • pp.633-641
    • /
    • 2017
  • The complexity of macro-fiber composite (MFC) materials increasing the difficulty in simulation and analysis of MFC integrated structures. To give an accurate prediction of MFC bonded smart structures for the simulation of shape and vibration control, the paper develops a linear electro-mechanically coupled static and dynamic finite element (FE) models based on the first-order shear deformation (FOSD) hypothesis. Two different types of MFCs are modeled and analyzed, namely MFC-d31 and MFC-d33, in which the former one is dominated by the $d_{31}$ effect, while the latter one by the $d_{33}$ effect. The present model is first applied to an MFC-d33 bonded composite plate, and then is used to analyze both active shape and vibration control for MFC-d31/-d33 bonded plate with various piezoelectric fiber orientations.

Feasibility of MFC (Macro-Fiber Composite) Transducers for Guided Wave Technique

  • Ren, Gang;Yun, Dongseok;Seo, Hogeon;Song, Minkyoo;Jhang, Kyung-Young
    • 비파괴검사학회지
    • /
    • 제33권3호
    • /
    • pp.264-269
    • /
    • 2013
  • Since MFC(macro-fiber composite) transducer has been developed, many researchers have tried to apply this transducer on SHM(structural health monitoring), because it is so flexible and durable that it can be easily embedded to various kinds of structures. The objective of this paper is to figure out the benefits and feasibility of applying MFC transducers to guided wave technique. For this, we have experimentally tested the performance of MFC patches as transmitter and sensors for excitation and reception of guided waves on the thin aluminum alloy plate. In order to enhance the signal accuracy, we applied the FIR filter for noise reduction as well as used STFT(short-time Fourier transform) algorithm to image the guided wave characteristics clearly. From the results, the guided wave generated based on MFC showed good agreement with its theoretical dispersion curves. Moreover, the ultrasonic Lamb wave techniques based on MFC patches in pitch-catch manner was tested for detection of surface notch defects of which depths are 10%, 20%, 30% and 40% of the aluminum plate thickness. Results showed that the notch was detectable well when the notch depth was 10% of the thickness or greater.

Damage detection for pipeline structures using optic-based active sensing

  • Lee, Hyeonseok;Sohn, Hoon
    • Smart Structures and Systems
    • /
    • 제9권5호
    • /
    • pp.461-472
    • /
    • 2012
  • This study proposes an optics-based active sensing system for continuous monitoring of underground pipelines in nuclear power plants (NPPs). The proposed system generates and measures guided waves using a single laser source and optical cables. First, a tunable laser is used as a common power source for guided wave generation and sensing. This source laser beam is transmitted through an optical fiber, and the fiber is split into two. One of them is used to actuate macro fiber composite (MFC) transducers for guided wave generation, and the other optical fiber is used with fiber Bragg grating (FBG) sensors to measure guided wave responses. The MFC transducers placed along a circumferential direction of a pipe at one end generate longitudinal and flexural modes, and the corresponding responses are measured using FBG sensors instrumented in the same configuration at the other end. The generated guided waves interact with a defect, and this interaction causes changes in response signals. Then, a damage-sensitive feature is extracted from the response signals using the axi-symmetry nature of the measured pitch-catch signals. The feasibility of the proposed system has been examined through a laboratory experiment.

리브를 갖는 FRP 판과 고인성섬유보강콘크리트로 이루어진 합성보의 파괴거동에 대한 실험적 연구 (An Experimental Study for Failure Behavior of Composite Beams with DFRCC and FRP Plank with Rib)

  • 강가람;유승운
    • 한국산학기술학회논문지
    • /
    • 제17권3호
    • /
    • pp.16-23
    • /
    • 2016
  • 고인성섬유보강콘크리트는 기존의 콘크리트에 비해 인성을 크게 개선한 재료로써, 콘크리트 구조물의 여러 분야에 적용 가능한 건설 신재료로 평가되고 있다. 본 연구에서는 고인성섬유보강콘크리트와 리브를 갖는 FRP 판을 인장 보강재 및 영구거푸집으로 활용한 합성보의 파괴거동에 관한 실험을 실시하였다. 비교를 위해 일반콘크리트와 PVA계열인 RF4000과 PP계열인 PP-macro의 섬유를 사용하였으며, 각각 RF4000+RSC15, PP-macro+RSC15를 혼입하여 합성보를 제작하여 실험하였다. FRP 판에 잔골재를 미부착한 경우는 보의 중앙에 발생한 휨 균열이 크게 벌어지면서 FRP 판과 콘크리트가 미끄러짐에 의한 파괴형태를 보여주고 있음으로 잔골재 부착은 필수적 사항이라 판단되며, 파괴모드에 대한 섬유보강재의 영향은 크지 않은 것으로 판단된다. FRP 판에 잔골재를 부착한 실험 결과는 1200, 2000mm 모두 콘크리트와 FRP 사이에 충분한 부착이 형성되었다. 일반콘크리트보다 섬유보강재를 혼입한 경우 최대 하중이 높게 나타났고, 그 중 PP계열의 섬유보강재를 혼입한 경우 최대 하중이 가장 높게 나타났다. 균열이 섬유보강재에 의해 지연되면서 FRP 리브와의 합성작용에 의해 발생한 것으로 판단된다.