• Title/Summary/Keyword: machine data

Search Result 6,279, Processing Time 0.041 seconds

Comparative study of prediction models for corporate bond rating (국내 회사채 신용 등급 예측 모형의 비교 연구)

  • Park, Hyeongkwon;Kang, Junyoung;Heo, Sungwook;Yu, Donghyeon
    • The Korean Journal of Applied Statistics
    • /
    • v.31 no.3
    • /
    • pp.367-382
    • /
    • 2018
  • Prediction models for a corporate bond rating in existing studies have been developed using various models such as linear regression, ordered logit, and random forest. Financial characteristics help build prediction models that are expected to be contained in the assigning model of the bond rating agencies. However, the ranges of bond ratings in existing studies vary from 5 to 20 and the prediction models were developed with samples in which the target companies and the observation periods are different. Thus, a simple comparison of the prediction accuracies in each study cannot determine the best prediction model. In order to conduct a fair comparison, this study has collected corporate bond ratings and financial characteristics from 2013 to 2017 and applied prediction models to them. In addition, we applied the elastic-net penalty for the linear regression, the ordered logit, and the ordered probit. Our comparison shows that data-driven variable selection using the elastic-net improves prediction accuracy in each corresponding model, and that the random forest is the most appropriate model in terms of prediction accuracy, which obtains 69.6% accuracy of the exact rating prediction on average from the 5-fold cross validation.

The 4th.industrial revolution and Korean university's role change (4차산업혁명과 한국대학의 역할 변화)

  • Park, Sang-Kyu
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.1
    • /
    • pp.235-242
    • /
    • 2018
  • The interest about 4th Industrial Revolution was impressively increased from newspapers, iindustry, government and academic sectors. Especially AI what could be felt by the skin of many peoples, already overpassed the ability of the human's even in creative areas. Namely, now many people start fo feel that the effect of the revolution is just infront of themselves. There were several issues in this trend, the ability of deep learning by machine, the identity of the human, the change of job environment and the concern about the social change etc. Recently many studies have been made about the 4th industrial revolution in many fields like as AI(artificial intelligence), CRISPR, big data and driverless car etc. As many positive effects and pessimistic effects are existed at the same time and many preventing actions are being suggested recently, these opinions will be compared and analyzed and better solutions will be found eventually. Several educational, political, scientific, social and ethical effects and solutions were studied and suggested in this study. Clear implication from the study is that the world we will live from now on is changing faster than ever in the social, industrial, political and educational environment. If it will reform the social systems according to those changes, a society (nation or government) will grasp the chance of its development or take-off, otherwise, it will consume the resources ineffectively and lose the competition as a whole society. But the method of that reform is not that apparent in many aspects as the revolution is progressing currently and its definition should be made whether in industrial or scientific aspect. The person or nation who will define it will have the advantage of leading the future of that business or society.

Studies on the Static Withdrawal Resistance on Nail in Wood (목재(木材)에 있어서 못의 정적인발저항(靜的引拔低抗)에 관한 연구(硏究))

  • Kim, Su-Chang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.8-11
    • /
    • 1979
  • The apparatus for measuring the static withdrawal resistance of nail is the AUTOGROPH S-500 static testing machine. The nails were 0.25 - 0.26 cm in diameter, 4.9-5.1cm in length, and were driven into wood for a depth of 3.0 cm. The physical properties of wood specimens are shown in table 1. Some data obtained in this experiment are as follows 1) The effects of the direction of driving and the time after driving upon static withdrawal resistance are shown in fig. 2-3. 2) The relations between static withdrawal resistance are moisture content of wood are characterized by nearly straight line as shown in fig. 4-5. The empirical formula areas follows: Y = -0.074 x + 12.73 (Pinus koraiensis Sieb & Zucc. - radial) Y = -0.073 x + 7.54 (Pinus koraiensis Sieb & Zucc. - longitudinal) Y = -0.061 x + 12.80 (Larix leptolesis Gord. - tangential) Y = -0.081 x + 7.61 (Larix leptolepsis Gord. - longitudinal) Where Y is the static withdrawal resistance ($kg{\cdot}cm$) and x is the moisture content(%).

  • PDF

Early and Late Effect of External Abdominal Irradiation on Small Intestine of Mice at Various Total Dose and Intervals - Histopathologc Aspects of Damage and Recovery - (복부 방사선 조사에서 총 선량 및 회복기간에 따른 마우스 소장의 급만성 효과 -손상 및 회복의 병리조직학적 변화-)

  • Kim, Myung-Se;Choi, Won-Hee
    • Radiation Oncology Journal
    • /
    • v.5 no.1
    • /
    • pp.1-11
    • /
    • 1987
  • Total 390 mice were irradiated with $2{\times}3cm$ abdominal field and $200{\times}5/wk$ regimen with orthovoltage x-ray machine. All animals were divided into 2 large groups, damage and recovery, and histopathologic changes were analyzed at various total dose level (1,000 cCy-5,000 cCy) and intervals (1 week-15 weeks). Almost acute changes such as decreased mitotic activity, villi shortening and focal erosion of mucosa recovered within 1-2 weeks in 1,000-3,000 cGy irradiated group but mild changes persisted in 4,000 and 5,000 cCy irradiated groups. Chronic delayed changes such as thickening of vessel wall with focal thrombosis, submucosal fibrosis, mucosal atrophy and chronic ulcer were observed from 2-3 week specimens in 4,000 and 5,000 cGy groups, These late changes recovered slightly, as increasing time intervals after irradiation but mild, persistant changes were observed throught all follow up period. These data suggest hat even 4,000 cCy is not completely safe for possible permanent damage and judicious modificiation of total dose, dose rate, fraction size, and field size should be considered for better results.

  • PDF

Application of Terahertz Spectroscopy and Imaging in the Diagnosis of Prostate Cancer

  • Zhang, Ping;Zhong, Shuncong;Zhang, Junxi;Ding, Jian;Liu, Zhenxiang;Huang, Yi;Zhou, Ning;Nsengiyumva, Walter;Zhang, Tianfu
    • Current Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.31-43
    • /
    • 2020
  • The feasibility of the application of terahertz electromagnetic waves in the diagnosis of prostate cancer was examined. Four samples of incomplete cancerous prostatic paraffin-embedded tissues were examined using terahertz spectral imaging (TPI) system and the results obtained by comparing the absorption coefficient and refractive index of prostate tumor, normal prostate tissue and smooth muscle from one of the paraffin tissue masses examined were reported. Three hundred and sixty cases of absorption coefficients from one of the paraffin tissues examined were used as raw data to classify these three tissues using the Principal Component Analysis (PCA) and Least Squares Support Vector Machine (LS-SVM). An excellent classification with an accuracy of 92.22% in the prediction set was achieved. Using the distribution information of THz reflection signal intensity from sample surface and absorption coefficient of the sample, an attempt was made to use the TPI system to identify the boundaries of the different tissues involved (prostate tumors, normal and smooth muscles). The location of three identified regions in the terahertz images (frequency domain slice absorption coefficient imaging, 1.2 THz) were compared with those obtained from the histopathologic examination. The tissue tumor region had a distinctively visible color and could well be distinguished from other tissue regions in terahertz images. Results indicate that a THz spectroscopy imaging system can be efficiently used in conjunction with the proposed advanced computer-based mathematical analysis method to identify tumor regions in the paraffin tissue mass of prostate cancer.

A COMPARATIVE STUDY ON SHEAR BOND STRENGTHS INFLUENCED BY TIME ELAPSED AFTER BRACKET BONDING WITH A LIGHT-CURED GLASS IONOMER CEMENT (광중합형 글래스아이오노머 시멘트의 브라켓 접착후 시간 경과에 따른 전단결합강도의 비교연구)

  • Lee, Ki-Soo;Lim, Ho-Nam;Park, Young Guk;Shin, Kang-Seob
    • The korean journal of orthodontics
    • /
    • v.25 no.5 s.52
    • /
    • pp.605-611
    • /
    • 1995
  • The purpose of this study was to evaluate effects of time on shear bond strengths of a light-cured glass ionomer cement and chemically cured resin cement to enamel, and to observe the failure patterns of bracket bondings. Shear bond strength of a light-cured glass ionomer cement were compared with that of a resin cement. Metal brackets were bonded on the extracted human bicuspids. Specimens were subjected to a shear load(in an Instron machine) after storage at room temperature for 5 and 15 minutes; after storage in distilled water at $37^{\circ}C$ for 1 or 35 days. The deboned specimens were measured In respect of adhesive remnant index. The data were evaluated and tested by ANOVA, Duncan's multiple range test, and t-test, and those results were as follows. 1. The shear bond strength of light-cured glass ionomer cement is higher than that of resin cement at 5 and 15 minutes. 2. The shear bond strengths of both light-cured glass ionomer cement and resin cement increase with time. There was no significant difference in those of both 1 day group and 35 day group 3. Light-cured glass ionomer cement is suitable as orthodontic bracket adhesives

  • PDF

Peel strength of denture liner to PMMA and polyamide: laser versus air-abrasion

  • Korkmaz, Fatih Mehmet;Bagis, Bora;Ozcan, Mutlu;Durkan, Rukiye;Turgut, Sedanur;Ates, Sabit Melih
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.287-295
    • /
    • 2013
  • PURPOSE. This study investigated the effect of laser parameters and air-abrasion on the peel strength of silicon-based soft denture liner to different denture resins. MATERIALS AND METHODS. Specimens (N=180) were prepared out of three different denture base resins (Rodex, cross-linked denture base acrylic resin; Paladent, heat-cured acrylic resin; Deflex, Polyamide resin) ($75mm{\times}25mm{\times}3mm$). A silicon-based soft denture liner (Molloplast B) was applied to the denture resins after the following conditioning methods: a) Air-abrasion ($50{\mu}m$), b) Er,Cr:YSGG laser (Waterlase MD Turbo, Biolase Technology) at 2 W-20 Hz, c) Er,Cr:YSGG laser at 2 W-30 Hz, d) Er,Cr:YSGG laser at 3 W-20 Hz, e) Er,Cr:YSGG laser at 3 W-30 Hz. Non-conditioned group acted as the control group. Peel test was performed in a universal testing machine. Failure modes were evaluated visually. Data were analyzed using two-way ANOVA and Tukey's test (${\alpha}$=.05). RESULTS. Denture liner tested showed increased peel strength after laser treatment with different parameters ($3.9{\pm}0.4-5.58{\pm}0.6$ MPa) compared to the control ($3.64{\pm}0.5-4.58{\pm}0.5$ MPa) and air-abraded groups ($3.1{\pm}0.6-4.46{\pm}0.3$ MPa), but the results were not statistically significant except for Paladent, with the pretreatment of Er,Cr:YSGG laser at 3 W-20 Hz. Polyamide resin after air-abrasion showed significantly lower peel strength than those of other groups ($3.1{\pm}0.6$ MPa). CONCLUSION. Heat-cured acrylic resin, PMMA, may benefit from Er,Cr:YSGG laser treatment at 3 W-20 Hz irradiation. Air-abrasion of polyamide resins should be avoided not to impair their peel bond strengths to silicon-based soft denture liners.

Bond strength of veneer ceramic and zirconia cores with different surface modifications after microwave sintering

  • Saka, Muhammet;Yuzugullu, Bulem
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.485-493
    • /
    • 2013
  • PURPOSE. To evaluate the effects of surface treatments on shear bond strength (SBS) between microwave and conventionally sintered zirconia core/veneers. MATERIALS AND METHODS. 96 disc shaped Noritake Alliance zirconia specimens were fabricated using YenaDent CAM unit and were divided in 2 groups with respect to microwave or conventional methods (n=48/group). Surface roughness (Ra) evaluation was made with a profilometer on randomly selected microwave (n=10) and conventionally sintered (n=10) cores. Specimens were then assessed into 4 subgroups according to surface treatments applied (n=12/group). Groups for microwave (M) and conventionally (C) sintered core specimens were as follows; $M_C$,$C_C$: untreated (control group), $M_1,C_1:Al_2O_3$ sandblasting, $M_2,C_2$:liner, $M_3,C_3:Al_2O_3$ sandblasting followed by liner. Veneer ceramic was fired on zirconia cores and specimens were thermocycled (6000 cycles between $5^{\circ}-55^{\circ}C$). All specimens were subjected to SBS test using a universal testing machine at 0.5 mm/min, failure were evaluated under an optical microscope. Data were statistically analyzed using Shapiro Wilk, Levene, Post-hoc Tukey HSD and Student's t tests, Two-Way-Variance- Analysis and One-Way-Variance-Analysis (${\alpha}$=.05). RESULTS. Conventionally sintered specimens ($1.06{\pm}0.32{\mu}m$) showed rougher surfaces compared to microwave sintered ones ($0.76{\pm}0.32{\mu}m$)(P=.046), however, no correlation was found between SBS and surface roughness (r=-0.109, P=.658). The statistical comparison of the shear bond strengths of $C_3$ and $C_1$ group (P=.015); $C_C$ and $M_C$ group (P=.004) and $C_3$ and $M_3$ group presented statistically higher (P=.005) values. While adhesive failure was not seen in any of the groups, cohesive and combined patterns were seen in all groups. CONCLUSION. Based on the results of this in-vitro study, $Al_2O_{3-}$ sandblasting followed by liner application on conventionally sintered zirconia cores may be preferred to enhance bond strength.

The effect of additional etching and curing mechanism of composite resin on the dentin bond strength

  • Lee, In-Su;Son, Sung-Ae;Hur, Bock;Kwon, Yong-Hoon;Park, Jeong-Kil
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.479-484
    • /
    • 2013
  • PURPOSE. The aim of this study was to evaluate the effects of additional acid etching and curing mechanism (light-curing or self-curing) of a composite resin on the dentin bond strength and compatibility of one-step self-etching adhesives. MATERIALS AND METHODS. Sixteen human permanent molars were randomly divided into eight groups according to the adhesives used (All-Bond Universal: ABU, Clearfil S3 Bond: CS3), additional acid etching (additional acid etching performed: EO, no additional acid etching performed: EX), and composite resins (Filtek Z-250: Z250, Clearfil FII New Bond: CFNB). Group 1: ABU-EO-Z250, Group 2: ABU-EO-CFNB, Group 3: ABU-EX-Z250, Group 4: ABU-EX-CFNB, Group 5: CS3-EO-Z250, Group 6: CS3-EO-CFNB, Group 7: CS3-EX-Z250, Group 8: CS3-EX-CFNB. After bonding procedures, composite resins were built up on dentin surfaces. After 24-hour water storage, the teeth were sectioned to make 10 specimens for each group. The microtensile bond strength test was performed using a microtensile testing machine. The failure mode of the fractured specimens was examined by means of an optical microscope at ${\times}20$ magnification. The data was analyzed using a one-way ANOVA and Scheffe's post-hoc test (${\alpha}$=.05). RESULTS. Additional etching groups showed significantly higher values than the no additional etching group when using All-Bond Universal. The light-cured composite resin groups showed significantly higher values than the self-cured composite resin groups in the Clearfil S3 Bond. CONCLUSION. The additional acid etching is beneficial for the dentin bond strength when using low acidic one-step self-etch adhesives, and low acidic one-step self-etch adhesives are compatible with self-cured composite resin. The acidity of the one-step self-etch adhesives is an influencing factor in terms of the dentin bonding strength and incompatibility with a self-cured composite resin.

Artificial teeth displacement of monolithic complete denture manufactured by 3D printer and milling machine (3차원 적층 출력과 밀링에 의해 제작된 일체형 의치의 인공치 변위 평가)

  • Kwak, Young-Hun;Lee, Sea-Han;Lee, Gyeong-Je;Kim, Hee-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.394-402
    • /
    • 2017
  • Purpose: The purpose of this study is to evaluate the displacement of artificial tooth of monolithic complete denture manufactured by milling and 3D printing method in which the denture base and the artificial teeth are simultaneously made. Materials and methods: Twelve upper and lower complete dentures for each were made by milling and 3D printing method. Group Up and Group Lp are a group of upper and lower dentures made by printing, and Group Um and Group Lm are denture groups made by milling. Group Uc and Group Lc are is a group of finally designed upper and lower dentures respectively. Measurements were performed between both central incisors (AB, ab), both canines (CD, cd), both first molars (EF, ef), between an incisor and a first molar (AE, ae), and between incisor and lingual point (AG, ag) for each upper and lower denture. Results: AG and ag value between printed dentures and original ones as well as between milled dentures and original ones showed a statistically significant difference (One-way ANOVA, P<.05) in both lower and upper monolithic dentures. In the lower monolithic ones, ab, cd and ef value revealed a significant difference between Group Lp and Group Lm (One-way ANOVA, P<.05). Conclusion: Dentures made using milling or 3D printers revealed statistically significant difference compared with those of original data. However, it showed clinically very accurate reproducibility.