• Title/Summary/Keyword: mSv

Search Result 571, Processing Time 0.023 seconds

Distribution of Zooplankton by ADCP's Echo Intensity in the Coastal Water used Yellow Loess (다층 도플러 유속계(ADCP)를 이용한 황토 살포 해역의 플랑크톤 평가)

  • Park, Ju-Sam;Choo, Hyo-Sang;Moon, Sung-Ryong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.16 no.2
    • /
    • pp.141-151
    • /
    • 2010
  • Harmful algal blooms (HABs), commonly known as red tides, are aquatic phenomena caused by the rapid growth and accumulation of certain microalgae, which can lead to marked discoloration of surface waters, and severe impacts on public health, commerce, and the environment. In South Korea, the red tides have been a serious and recurrent problem, especially along the south coast. Plenty of yellow loess was used to control an outbreak of the red tides for 15 years from 1996 until now. Yellow loess was almost sprayed in the vicinity of a large fish farming industry. In this research, the distribution characteristics and density distribution of zooplankton were investigated in autumn (Oct. 2008) and spring (Apr. 2009) using volume backscattering strength (SV) calculated by the zooplankton collected with north pacific standard (NORPAC) net and the echo intensity measured with ADCP at stations on the study area in the spraying ocean of yellow loess (SOYL), and the non-spraying ocean of yellow ocean (NOYL) by the red tide generating every year. The species number and the individuals per unit volume of the zooplankton collected in NOYL was high and it which was collected in SOYL was low. As a result of comparing the volume backscattering strength ($SV_c$) calculated by species and length of the zooplankton collected with NORPAC net with the volume backscattering strength ($SV_m$) calculated by the echo intensity measured with ADCP at stations on the study area, although $SV_c$ and $SV_m$ of NOYL were generally in agreement, $SV_m$ of SOYL was higher than $SV_c$ 4.3dB, i.e. ADCP is greatly influenced by suspended solid in SOYL. The horizontal distribution map of $SV_m$ at the study area in autumn (Oct. 2008) and spring (Apr. 2009) was drawn. $SV_m$ of SOYL is higher than NOYL and autumn is higher than spring. $SV_m$ can suppress the overestimate or underestimate of $SV_c$.

Radiation dose and Lifetime Attributable Risk of Cancer Estimates in 64-slice Multidetector Computed Tomography (64-절편 다행검출 CT 검사에서의 환자선량과 암 발생의 Lifetime Attributable Risk(LAR) 평가)

  • Kang, Yeong-Han;Park, Jong-Sam
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.4
    • /
    • pp.244-252
    • /
    • 2011
  • This study was to estimate the radiation dose associated with 64-slice multidetector CT(MDCT) in clinical practice and quantify the potential cancer risk associated with these examinations. Lifetime attributable risks(LAR) were estimated with models developed in the national Academies' Biological Effects of Ionizing Radiation VII report. Mean effective dose were 1.48mSv in Brain axial scan, 7.66mSv in chest routine contrast, 12.17mSv in coronary angiogram, 24.52mSv in Dynamic abdomen scan. LAR estimates for brain routine varied from 1 in 7463 for man to 1 in 4926 for women. In chest routine with contrast, LAR varied from 1 in 1449 for men to 1 in 952. LAR of Abdomen dynamic CT varied from 1 in 453 for men to 1 in 298 for women. So, 64-slice MDCT scan is associated with non-negligible LAR of cancer. Doses can be reduced by careful attention to scanning protocol.

Development of Internal Dose Assessment Procedure for Workers in Industries Using Raw Materials Containing Naturally Occurring Radioactive Materials

  • Choi, Cheol Kyu;Kim, Yong Geon;Ji, Seung Woo;Koo, Boncheol;Chang, Byung Uck;Kim, Kwang Pyo
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.291-300
    • /
    • 2016
  • Background: It is necessary to assess radiation dose to workers due to inhalation of airborne particulates containing naturally occurring radioactive materials (NORM) to ensure radiological safety required by the Natural Radiation Safety Management Act. The objective of this study is to develop an internal dose assessment procedure for workers at industries using raw materials containing natural radionuclides. Materials and Methods: The dose assessment procedure was developed based on harmonization, accuracy, and proportionality. The procedure includes determination of dose assessment necessity, preliminary dose estimation, airborne particulate sampling and characterization, and detailed assessment of radiation dose. Results and Discussion: The developed dose assessment procedure is as follows. Radioactivity concentration criteria to determine dose assessment necessity are $10Bq{\cdot}g^{-1}$ for $^{40}K$ and $1Bq{\cdot}g^{-1}$ for the other natural radionuclides. The preliminary dose estimation is performed using annual limit on intake (ALI). The estimated doses are classified into 3 groups ( < 0.1 mSv, 0.1-0.3 mSv, and > 0.3 mSv). Air sampling methods are determined based on the dose estimates. Detailed dose assessment is performed using air sampling and particulate characterization. The final dose results are classified into 4 different levels ( < 0.1 mSv, 0.1-0.3 mSv, 0.3-1 mSv, and > 1 mSv). Proper radiation protection measures are suggested according to the dose level. The developed dose assessment procedure was applied for NORM industries in Korea, including coal combustion, phosphate processing, and monazite handing facilities. Conclusion: The developed procedure provides consistent dose assessment results and contributes to the establishment of optimization of radiological protection in NORM industries.

Effective Dose Equivalent due to Inhalation of Indoor Radon-222 Daughters in Korea (한국인의 라돈-222 자핵종 호흡 실효선량당량 평가)

  • Chang, Si-Young;Ha, Chung-Woo;Lee, Byoung-Hun
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.1
    • /
    • pp.1-13
    • /
    • 1991
  • Effective dose equivalents resulting from inhalation of indoor radon-222 daughters at 12 residential areas in Korea were assessed by a simple mathematical lung dosimetry model based on the measurements of long-term averaged radon concentrations at 340 dwellings. The long-term averaged indoor radon-222 concentrations and corresponding eqilibrium equivalent radon $concentration(EEC_{Rn})$ measured by passive time-integrating CR-39 radon cups are in the range of $33.82{\sim}61.42Bq/m^3(median\;:\;48.90Bq/m^3)$ and of $13.53{\sim}24.57Bq/m^3(median\;:\;19.55Bq/m^3)$, respectively. The effective dose equvalent conversion factor for the exposure to unit $EEC_{Rn}$ derived in this study was estimated $1.07{\times}10^{-5}mSv/Bq\;h\;m^{-3}$ for a reference adult and agreed well with those recommended by the ICRP and UNSCEAR. The annual average dose equivalent to the lung $(H_{LUNG})$ from inhalation exposure to measured $EEC_{Rn}$ was estimated to be 20.90 mSv and resulting effective dose $equivalent(H_E)$ was to be 1.25 mSv, which is about 50% of the natural radiation exposure of 2.40 mSv/y to the public reported by the UNSCEAR.

  • PDF

Comparison of cone beam CT and conventional CT in absorbed and effective dose (Cone beam CT와 일반 CT의 흡수선량 및 유효선량 비교평가)

  • Kim, Sang-Yeon;Han, Jin-Woo;Park, In-Woo
    • Imaging Science in Dentistry
    • /
    • v.38 no.1
    • /
    • pp.7-15
    • /
    • 2008
  • Purpose: This study provides comparative measurements of absorbed and effective doses for newly developed cone beam computed tomography (CT) in comparison with these doses for conventional CT. Materials and Methods: Thermoluminescent dosimeter rods (TLD rod: GR-200, Thermo Fisher Scientific Inc., Waltham, MA, USA) were placed at 25 sites throughout the layers of Male ART Head and Neck Phantom (Radiology Support Devices Inc., Long Beach, USA) for dosimetry. Implagraphy, DCT Pro (Vatech Co., Hwasung, Korea) units, SCT-6800TXL (Shimadzu Corp., Kyoto, Japan), and Crane x 3+(Soredex Orion Corp., Helsinki, Finland) were used for radiation exposures. Absorption doses were measured with Harshaw 3500TLD reader (Thermo Fisher Scientific Inc., Waltham, MA, USA). Radiation weighted doses and effective doses were measured and calculated by 2005 ICRP tissue weighting factors. Results: Absorbed doses in Rt. submandibular gland were 110.57 mGy for SCT 6800TXL (Implant), 24.56 mGy for SCT 6800TXL (3D), 22.39 mGy for Implagraphy 3, 7.19 mGy for DCT Pro, 5.96 mGy for Implagraphy 1, 0.70 mGy for Cranex 3+. Effective doses $(E_{2005draft)$ were 2.551 mSv for SCT 6800TXL (Implant), 1.272 mSv for SCT 6800TXL (3D), 0.598 mSv for Implagraphy 3, 0.428 mSv for DCT Pro and 0.146 mSv for Implagraphy 1. These are 108.6, 54.1, 25.5, 18.2 and 6.2 times greater than panoramic examination (Cranex 3+) doses (0.023mSv). Conclusion: Cone beam CT machines recently developed in Korea, showed lower effective doses than conventional CT. Cone beam CT provides a lower dose and cost alternative to conventional CT, promising to revolutionize the practice of oral and maxillofacial radiology.

  • PDF

Comparing of the Administered Activities and the Effective Dose of the Various Pediatric Dose Formulas of Nuclear Medicine (핵의학검사의 방사성의약품 소아투여량 공식 별 투여량 및 유효선량 비교)

  • Gil, Jong-Won
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.8
    • /
    • pp.147-154
    • /
    • 2017
  • The purpose of this study is to calculate and compare administered activities(MBq) and effective dose(mSv) of the various pediatric dose formulas of pediatric nuclear medicine and to provide base data for the criteria of the optimal administered activities. This study compares dosages and effective doses of 5 types of pediatric dose formulas(Clark rule, Area rule, Webster rule, Young rule, Solomon(Fried) rule) based on the dosage for adults of 2 types of radiopharmaceuticals($^{99m}Tc$-MDP, $^{99m}Tc$-Pertechnetate). The administered activities in adults, which is the criteria for calculating the Pediatric administered activities, used the value from the 'Nuclear Medicine' written by J-G Jeong & M-Ch Lee. and the administered activities by the radioactivity per effective dose(mSv/MBq) of the radiopharmaceuticals for calculating the effective dose used the value from ICRP 80 and the UNSCEAR 2008 Report. As a result of the study, the output of Young rule is the lowest, and its difference between other formulas is from minimum 1.7 times to maximum 3,4 times. The difference between administered activities of $^{99m}Tc$-MDP is maximum 309.9MBq and the effective dose is 3.76mSv. $^{99m}Tc$-Pertechnetate showed the figure at the maximum 154.9MBq and the effective dose has a difference of 5.50mSv. Since the pediatric dose formulas differ not only in administered activities but also in effective doses, the optimal administered activities have to be developed for optimization of medical radiation.

Indoor Radon Levels and Effective Dose Estimation in Learning and Common Living Space of University (대학 내 학습공간과 공동 생활공간에 대한 실내 라돈 농도 측정과 유효선량 산출)

  • Kim, Jung-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.329-334
    • /
    • 2018
  • Radon which is natural component of air is a colorless and odorless radioactive gas. Radon exposure can also occur from some building materials if they are made from radon-containing substances by breathing. In this study, The radiation dose of radon concentration was detected at 8 buildings of the A university during 3-month from June. 2017 to August. 2017. We detected indoor radon exposure at 8 building of the university and estimated annual effective dose. The radon concentration of Hall G and Hall F of the A university represented 81 and $14Bq/m^3$ respectively and average indoor radon concentration represented $41.63Bq/m^3$. Average effective dose was estimated 0.40 mSv/y, maximum effective dose was 0.78 mSv/y and minimum effective dose was 0.13 mSv/y respectively. University is the place that students spend the almost whole time. We suggest ventilation and appropriate management of a building, which could reduce the natural radiation exposure by radon concentration.

Evaluation on the Radiological Shielding Design of a Hot Cell Facility (핫셀시설의 방사선 안전성 평가)

  • 조일제;국동학;구정회;정원명;유길성;이은표;박성원
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.1
    • /
    • pp.1-11
    • /
    • 2004
  • The hot cell facility for research activities related to the lithium reduction of spent fuel, which is designed to permit safe handling of source materials with radioactivity levels up to 1,385 TBq, is planned to be built. To meet this goal, the facility is designed to keep gamma and neutron radiation lower than the recommended dose-rate in normally occupied areas. The calculations peformed with QAD-CGGP and MCNP-4C are used to evaluate the proposed engineering design concepts that would provide acceptable dose-rates during a normal operation in hot cell facility. The maximum effective gamma dose-rates on the surfaces of the facility at operation area and at service area calculated by QAD-CGGP are estimated to be $2.10{\times}10^{-3}, 2.97{\times}10^{-3} and 1.01{\times}10{-1}$ mSv/h, respectively. And those calculated by MCNP-4C are $1.60{\times}10^{-3}, 2.99{\times}10^{-3} and 7.88{\times}10^{-2}$ mSv/h, respectively, The dose-rates contributed by neutrons are one order of magnitude less than that of gamma sources. Therefore, it is confirmed that the radiological design for hot cell facility satisfies the Korean criterion of 0.01 mSv/h for the operation area and 0.15 mSv/h for the service (maintenance) area.

  • PDF

A Study on the Dose Constraints for Occupational Exposure: Focusing on Expert Opinions by Field of Ridiation Industry (직무피폭의 선량제약치에 관한 연구: 분야별 전문가 의견 중심으로)

  • Il Park;Chan Hee Park;Kyu Hwan Jung;Chan Ho Park;Yong Geon Kim;Tae Jin Park
    • Journal of Radiation Industry
    • /
    • v.17 no.1
    • /
    • pp.61-67
    • /
    • 2023
  • A Study on the Introduction of Dose Constraints for Occupational Exposures: Focusing on Experts' Opinions by Field of Radiation Industry. The International Commission on Radiological Protection suggests Justification, Optimization, and Dose Limits as the three principles of radiological protection, among which, as a means of protection optimization, ICRP 103 recommends to set dose constraints. In this study, opinions are collected from experts in each category of radiation industries for stakeholder participation to qualify dose constraints. A guidance and questionnaire for analyzing the dose constraints have been developed for their collection, and opinions were collected from radiation protection experts in selected categories. 20 out of 22 experts, consisted with 91%, have assessed the dose constraints setting is necessary, and 2 experts, consisted with 9%, assessed it is unnecessary. The average of dose constraint presented by experts for RI production institutions is to be the highest level of 15.3 mSv, and light-water reactors (14.6 mSv), non-destructive inspection (14.4 mSv), heavy-water reactor and medical institutes (13.9mSv) is to be above the overall average dose constraint. In case of public institutions, the average dose constraint is to be 8.6mSv, and research institutions (8.8mSv), educational institutions (9.6 mSv), waste disposal sites (9.7 mSv), and general industries (10.6 mSv) are resulted to below the overall average dose constraint. As for the means of setting dose constraints, 8 experts out of 22 suggested setting dose constraints for each specific industry or task. And, 5 experts especially suggest setting dose constraints for the specific groups with relatively high exposure, such as workers with above the record levels. As a countermeasure for workers who exceed the dose constraints, 15 experts out of 22 expressed that the cause analyses for them and preparation for a plan of reducing them are necessary.

Interfacial Characteristics of Epoxy Composites Filled with γ-APS Treated Natural Zeolite (γ-APS로 표면처리된 천연 제올라이트/에폭시 복합재료의 계면특성)

  • Lee, Jae-Young;Lee, Sang-Keun;Kim, Sang-Wook
    • Journal of Adhesion and Interface
    • /
    • v.2 no.3
    • /
    • pp.1-8
    • /
    • 2001
  • Epoxy composites filled with natural zeolite was prepared to investigate the effects of silane coupling agent, ${\gamma}$-APS (${\gamma}$-aminopropyltriethoxysilane)on the surface free energy, tensile properties and interfacial morphology. The value of Lifshitz-van der Waals component, ${\gamma}{\frac{LW}{SV}}$ for polar was $19.22mJ/m^2$ and increased, while that of Lewis acid-base component, ${\gamma}{\frac{AB}{SV}}$ for polar was $15.27mJ/m^2$ and decreased with the increasing content of ${\gamma}$-APS treatment. It is due that the surface of the zeolite is more coated by hydrophobic of alkyl group than hydrophilic amine or hydroxyl group. The tensile strength and Young's modulus of epoxy system were improved by the treatment with ${\gamma}$-APS due to the strong interface bonding, which was confirmed by SEM.

  • PDF