• Title/Summary/Keyword: mAbs

Search Result 207, Processing Time 0.024 seconds

Production of monoclonal antibodies against marine birnavirus (Marine birnavirus (MABV)에 대한 단클론 항체 생산)

  • Kong, Kyoung-Hui;Oh, Myung-Joo;Kim, Wi-Sik
    • Journal of fish pathology
    • /
    • v.33 no.2
    • /
    • pp.171-175
    • /
    • 2020
  • We developed and subsequently characterized mouse monoclonal antibodies (mAbs) against marine birnavirus (MABV). Eight hybridoma clones secreting mAbs against MABV were established. All eight mAbs (8G6, 11C3, 15E3, 17H6, 32A6, 35A7, 38B5, and 47E3) were reacted with viral protein 3 of MABV in MABV-infected CHSE-214, whereas, no reactivity was observed in normal CHSE-214 by western blot analysis. Moreover, these eight mAbs were strongly reacted with MABV, and no cross-reactivity has been observed against other five fish viruses (hirame rhabdovirus, infectious hematopoietic necrosis virus, nervous necrosis virus, spring viraemia of carp virus, and viral hemorrhagic septicemia virus), although five mAb (11C3, 15E3, 17H6, 32A6, and 38B5) reacted with both MABV and infectious pancreatic necrosis virus by enzyme linked immunosorbent assay (ELISA). These results indicate that the mAbs can be of value in MABV detection.

Rheological and mechanical properties of ABS/PC blends

  • Khan M.M.K.;Liang R.F.;Gupta R.K.;Agarwal S.
    • Korea-Australia Rheology Journal
    • /
    • v.17 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • Acrylonitrile-Butadiene-Styrene (ABS), polycarbonate (PC) and their alloys are an important class of engineering thermoplastics that are widely used for automotive industry, computer and equipment housings. For the process of recycling mixtures of ABS and PC, it is desirable to know how sensitive the blend properties are to changes in compositions. It was for this reason that blends of virgin ABS and virgin PC at five different compositions, namely, $15\%,\;30\%,\;50\%,\;70%$ and $85\%$ by weight of ABS were prepared and characterised by rheological and mechanical measurements. Rheological properties of these blends in steady, oscillatory and transient step shear and mechanical properties, namely, tensile strength, elongation-at-break and Izod impact strength are reported. The results show that PC behaves in a relatively Newtonian manner, but ABS exhibits significant shear thinning. The ABS-rich blends show a trend that is similar to that of ABS, while PC-rich blends, namely $0\%$ and $15\%$, exhibit a nearly Newtonian behaviour. However, at a fixed shear rate or frequency, the steady shear or the dynamic viscosity varied respectively in a non-mono-tonic manner with composition. Except for $15\%$ blend, the viscosities of other blends fall into a narrow band indicating a wide-operation window of varying blend ratio. The blends exhibited a lower viscosity than either of the two pure components. The other noticeable feature was that the blends at $70\%$ and $85\%$ ABS content had a higher G' than pure ABS, indicating an enhancement of elastic effect. The tensile yield strength of the blends followed the 'rule of mixtures' showing a decreasing value with the increase of ABS content in PC. However, the elongation-at-break and the impact strength did not appear to obey this 'rule of mixtures,' which suggests that morphology of the blends also plays a significant role in determining the properties. Indeed, scanning electron micrographs of the fracture surfaces of the different blends validate this hypothesis, and the $15\%$ blend is seen to have the most distinct morphology and correspondingly different behaviour and properties.

Evaluation of Nuclear Medicine Applications of 3D Printing Phantom - Gamma Camera Centrically (3D 프린팅 팬텀의 핵의학분야 적용 평가 - 감마카메라 중심으로)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Ji-Hyeon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.65-73
    • /
    • 2017
  • Purpose 3D 프린팅 기술은 3D 스캔이나 모델링을 통하여 적측가공 방식으로 제작하는 기공기술로서 금형 없이 직접 생산이 가능하고 빠른 시간 내에 제작이 가능하여 최근 다양한 산업분야에서 본격적으로 적용되고 있다. 3D 프린팅 기술은 의료분야에 있어, 영상의학 및 방사선 치료분야에서 다양하게 활용되고 있지만 핵의학 분야에서는 관련 연구가 미비한 실정이다. 그러므로 본 연구는 기존에 적용되고 있는 핵의학분야 팬텀과 3D 프린팅 기술로 제작된 텀의 특성을 비교하고 적용 가능성을 평가하는데 목적을 두었다. Materials and Methods 방사선 투과도 변화측정 국제기준 팬텀인 알루미늄(Aluminum) 계단 쐐기(step wedge)를 기준($140mm{\times}62mm{\times}35mm$)으로 PMMA(Poly Methyl Meta Acrylate)와 ABS(Acrylonitrile Butadiene Styrene)재질로 각각 동일한 크기의 팬텀을 제작하였다. PMMA 팬텀은 핵의학 분야에서 주로 적용되는 팬텀의 성분과 동일한 소재로 제작하였고, ABS 팬텀 제작은 3D 프린팅 기술의 액체 기반형의 SLA(Stereo Lithography Apparatus)기법을 사용하여 제작하였다. 본 연구는 SPECT/CT장비 BrightView XCT(Philips Health Care, Cleveland, USA)를 이용하였다. 영상 획득은 Rectangular Flood phantom(Biodex, New York, USA) $^{99m}TcO_4$ 3, 6 mCi와 $^{57}Co$ lood phantom(adqual, New Hampshire, USA) $^{57}Co$ 20 mCi를 이용하여 Aluminum, PMMA, ABS 팬텀에 대해 60 min 리스트모드(List mode)로 획득하였다. 획득한 영상의 분석을 위해 관심영역(ROI)을 설정하여 각 팬텀의 단계별로 평가하였다. Results 방사선원의 종류 및 방사선량에 따라 ABS 팬텀의 계수치는 PMMA 팬텀의 계수치와 유사한 값을 나타내며, 두께의 증가에 따라 선형적으로 감소하였다. Aluminum, PMMA, ABS 팬텀의 선감약계수를 비교했을 때, Aluminum 팬텀의 선감약계수는 나머지 두 팬텀보다 수치가 높았고, PMMA, ABS 팬텀에서는 근사치의 선감약계수가 나타났다. Conclusion 3D 프린팅 기술로 제작된 ABS 팬텀을 기준으로 PMMA 팬텀은 두께가 증가함에 따른 계수치의 변화가 유사하게 선형적으로 감소하였고, 선감약계수도 근사치로 나타내었다. ABS 팬텀의 핵의학적 적용 가능성을 확인할 수 있었으며, 추후 연구를 통해 세부적인 교정치(correction value)를 적용한다면 활발한 적용이 가능하리라 사료된다.

  • PDF

Production of monoclonal antibodies against infectious hematopoietic necrosis virus (IHNV) (Infectious hematopoietic necrosis virus (IHNV)에 대한 단클론 항체 생산)

  • Kyoung-Hui Kong;Myung-Joo Oh;Choon-Sup Kim;Wi-Sik Kim
    • Journal of fish pathology
    • /
    • v.36 no.2
    • /
    • pp.389-394
    • /
    • 2023
  • Infectious hematopoietic necrosis virus (IHNV) is s significant viral pathogen affecting cultured rainbow trout (Oncorhynchus mykiss) in Korea. In this study, five monoclonal antibodies (mAbs) (IHNV-1, 2, 3, 4, and 5) were produced using purified IHNV. Reactivities of these mAbs were analyzed by western blot (WB), enzyme-linked immunosorbent assay (ELISA), and indirect fluorescent antibody test (IFAT). These mAbs recognized glycoprotein (69 kDa, IHNV-1), nucleocapsid protein (39 kDa, IHNV-3, 4, and 5), or phosphoprotein (27 kDa, IHNV-2) of IHNV by WB analysis. ELISA results indicated that these five mAbs were specific to IHNV without showing any cross-reactivity against other fish viruses (hirame rhabdovirus, infectious pancreatic necrosis virus, and viral hemorrhagic septicemia virus). IFAT demonstrated specific fluorescence signals of IHNV-infected epithelioma papulosum cyprini (EPC) cells, whereas no reactivity of normal EPC cells was observed. These mAbs can be very useful for immuno-diagnosis of IHNV infection.

ABS ALGORITHM FOR SOLVING A CLASS OF LINEAR DIOPHANTINE INEQUALITIES AND INTEGER LP PROBLEMS

  • Gao, Cheng-Zhi;Dong, Yu-Lin
    • Journal of applied mathematics & informatics
    • /
    • v.26 no.1_2
    • /
    • pp.349-353
    • /
    • 2008
  • Using the recently developed ABS algorithm for solving linear Diophantine equations we introduce an algorithm for solving a system of m linear integer inequalities in n variables, m $\leq$ n, with full rank coefficient matrix. We apply this result to solve linear integer programming problems with m $\leq$ n inequalities.

  • PDF

Characterization of Monoclonal Antibodies against Human Leukocyte Common Antigen (CD45)

  • Shin, Hyang-Mi;Cho, Woon-Dong;Lee, Geon-Kook;Lee, Seon-Hwa;Lee, Kyung-Mee;Ji, Gil-Yong;Yoon, Sang-Soon;Koo, Ji-Hae;Lee, Ho-Chang;Lee, Ki-Hyeong;Song, Hyung-Geun
    • IMMUNE NETWORK
    • /
    • v.11 no.2
    • /
    • pp.114-122
    • /
    • 2011
  • Background: The leukocyte common antigen (CD45) is a transmembrane-type protein tyrosine phosphatase that has five isoforms. Methods: We generated seven murine mAbs against human CD45 by injecting cells from different origins, such as human thymocytes, PBMCs, and leukemic cell lines. By using various immunological methods including flow cytometry, immunohistochemistry, and immunoprecipitation, we evaluated the reactivity of those mAbs to CD45 of thymus as well as tonsil lysates. Furthermore, we transiently transfected COS-7 cells with each of gene constructs that express five human CD45 isoforms respectively, and examined the specificities of the mAbs against the transfected isoforms. Results: In case of thymocytes, lymphocytes, and monocytes, all the seven mAbs demonstrated positive reactivities whereas none was reactive to erythrocytes and platelets. The majority of immune cells in formalin-fixed paraffin-embedded thymus and tonsil tissues displayed strong membranous immunoreactivity, and the main antigen was detected near 220 kDa in all cases. Among the mAbs, four mAbs (AP4, DN11, SHL-1, and P6) recognized a region commonly present in all the five isoforms. One mAb, YG27, recognized four isoforms (ABC, AB, BC, and O). Two mAbs, P1 and P14, recognized the isoforms that contain exon A encoded regions (ABC and AB). Conclusion: In this study, we confirmed that AP4, DN11, SHL-1, YG27 and P6, are mAbs reactive with the CD45 antigen whereas P1 and P14 are reactive with the CD45RA antigen.

Evaluation of Scintillation Camera Applications of 3D Printing Phantom (3D 프린팅 팬텀의 섬광카메라 적용 평가)

  • Park, Hoon-Hee;Lee, Ju-young;Kim, Ji-Hyeon
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.343-350
    • /
    • 2021
  • 3D printing technology is an additive manufacturing technology produced through 3D scanning or modeling method. This technology can be produced in a short time without mold, which has recently been applied in earnest in various fields. In the medical field, 3D printing technology is used in various fields of radiology and radiation therapy, but related research is insufficient in the field of nuclear medicine. In this study, we compare the characteristics of traditional nuclear medicine phantom with 3D printing technology and evaluate its applicability in clinical trials. We manufactured the same size phantom of poly methyl meta acrylate(PMMA) and acrylonitrile butadiene styrene(ABS) based on the aluminum step wedge. We used BrightView XCT(Philips Health Care, Cleveland, USA) SPECT/CT. We acquired 60 min list mode for Aluminum, PMMA and ABS phantoms using Rectangular Flood Phantom (Biodex, New York, USA) 99mTcO4 3 mCi(111 MBq), 6 mCi (222MBq) and 57Co Flood phantom(adq, New Hampshire, USA). For the analysis of acquired images, the region of interest(ROI) were drawn and evaluated step by step for each phantom. Depending on the type of radioisotope and radiation dose, the counts of the ABS phantom was similar to that of the PMMA phantom. And as the step thickness increased, the counts decreased linearly. When comparing the linear attenuation coefficient of Aluminum, PMMA and ABS phantom, the linear attenuation coefficient of the aluminium phantom was higher than that of the others, and the PMMA and ABS phantom had similar the linear attenuation coefficient. Based on ABS phantom manufactured by 3D printing technology, as the thickness of the PMMA phantom increased, the counts and linear attenuation coefficient decreased linearly. It has been confirmed that ABS phantom is applicable in the clinical field of nuclear medicine. If the calibration factor is applied through further research, it is believed that practical application will be possible.

Surface Modification by Atmospheric Pressure DBDs Plasma: Application to Electroless Ni Plating on ABS Plates

  • Song, Hoshik;Choi, Jin Moon;Kim, Tae Wan
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.3
    • /
    • pp.133-138
    • /
    • 2013
  • Acrylonitrile-butadiene-styrene (ABS) plastic is a polymer material extensively used in electrical and electronic applications. Nickel (Ni) thin film was deposited on ABS by electroless plating, after its surface was treated and modified with atmospheric plasma generated by means of dielectric barrier discharges (DBDs) in air. The method in this study was developed as a pre-treatment for electroless plating using DBDs, and is a dry process featuring fewer processing steps and more environmentally friendliness than the chemical method. After ABS surfaces were modified, surface morphologies were observed using a scanning electron microscope (SEM) to check for any physical changes of the surfaces. Cross-sectional SEM images were taken to observe the binding characteristics between metallic films and ABS after metal plating. According to the SEM images, the depths of ABS by plasma are shallow compared to those modified by chemically treatment. The static contact angles were measured with deionized (DI) water droplets on the modified surfaces in order to observe for any changes in chemical activities and wettability. The surfaces modified by plasma showed smaller contact angles, and their modified states lasted longer than those modified by chemical etching. Adhesion strengths were measured using 3M tape (3M 810D standard) and by 90° peel-off tests. The peel-off test revealed the stronger adhesion of the Ni films on the plasma-modified surfaces than on the chemically modified surfaces. Thermal shock test was performed by changing the temperature drastically to see if any detachment of Ni film from ABS would occur due to the differences in thermal expansion coefficients between them. Only for the plasma-treated samples showed no separation of the Ni films from the ABS surfaces in tests. The adhesion strengths of metallic films on the ABS processed by the method developed in this study are better than those of the chemically processed films.

Implementation and Design of HILS for Development of the ABS ECU for Commercial Vehicle (상용차용 ABS ECU 개발을 위한 HILS 시스템 설계 및 구현)

  • Hwang, D.H.;Cho, J.M.;Sim, W.J.;Park, D.Y.;Kim, Y.J.;Joh, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11d
    • /
    • pp.609-611
    • /
    • 2000
  • ABS(Antilock Brake System), Prevents the wheels from "locking" and improve steering during braking. Currently, safety and environmental issues are a major concern in the automotive industry. ABS has become the vital brake system HILS (Hardware In-the-Loop Simulation) is an effective tool for design. performance evaluation and test of developed vehicle subsystems such as ABS. suspension. and steering systems. This paper describes a HILS model for an ABS/ASR application Also the design and implementation of HILS system for development of the ABS ECU(Electronic Centre) Unit) for commercial vehicle are presented.

  • PDF

Production of Monoclonal Antibodies Specific to Korean Mistletoe pectin (KML-C) and Their Characterization (한국산 겨우살이 렉틴 (KML-C)에 대한 단일크론항체의 생산과 특성)

  • 윤택준;유영춘;강태봉;김성훈;김갑수
    • YAKHAK HOEJI
    • /
    • v.45 no.2
    • /
    • pp.180-189
    • /
    • 2001
  • We have reported that water-extracted Korean mistletoe (KM-110) had various biological activities such as antitumor and immunomodulatory activity, and the pectin fraction (KML-C) of the extract was one of major factors related to its biological functions. In this paper, we produced murine monoclonal antibody (mAb) against KML-C. The cAbs obtained were largely classified into two groups according to specificity to KML-C and ML-I, a pectin from European mistletoe. One group mAbs (9H7-D10 and 3C2-lH4) strongly reacted with KML-C, but not ML-I. In contrast, another group cAbs (8Bll-2C5, BE12-3E9 and 5E10-Fl) reacted with both KML-C and ML-1. The subisotypes of these mobs were shown to be IgGl (9H7-lD10, 3C2-lH4 and 8Bll-2C5) or IgM (8E12-3E9 and 5E10-Fl). To develop an assay system for determination of the amount of KML-C, we established the sandwich ELISA (enzyme-linked immunosorbent assay) method using these mAbs and horse radish peroxidase (HRP)-labelled cAbs. In various combinations of the cAbs for coated antibody and detection antibody, the sandwich ELISA quantitatively detected KML-C, showing the detection limit ranging from 7-5,000 ng/ml. Especially reproducibility (C.V) of the sandwich ELISA, in which 8E12-3E9 was used for coating antibody and 8Bll-2C5-HRP for detection antibody, was 4.59-5.83 in intra assay, and 3.9-9.4 in inter assay.

  • PDF