• Title/Summary/Keyword: m-pre-$T_2$

Search Result 293, Processing Time 0.058 seconds

Cryopreservation of Pine Wood Nematode, Bursaphelenchus xylophilus

  • Park, Ju-Yong;Shin, Keum-Chul;Kim, Kyung-Hee;Lee, Seung Kyu;Lee, Jong Kyu
    • Journal of Korean Society of Forest Science
    • /
    • v.94 no.5 s.162
    • /
    • pp.334-337
    • /
    • 2005
  • Pine wood nematode isolates from Haman, Gyoungsangnam-do were cryopreserved with three different cryoprotectants (glycerol, ethylene glycol and dimethylsulfoxide), Nematode Growth medium (NGM) and M 9 buffer solution, respectively, and then survival rate, reproduction ability, and pathogenicity of stored nematodes were compared. Survival rates of juvenile was excellent in 15% glycerol solution as $72{\pm}5.3%$. The survival ability of nematodes at juvenile stage was more efficient than that of nematodes at adult stage. Pre-incubation treatment at $4^{\circ}C$ before storing in liquid nitrogen didn't affect the survival ability of pine wood nematode. When the reproduction ability of nematodes was confirmed on Botrytis cinerea agar plates at $28^{\circ}C$ incubator, there was no difference between cryopreserved and non-cryopreserved. Pathogenic ability of cryopreserved nematodes was also evaluated and confirmed by artificially inoculating them on 2-year old red pine seedlings.

A study on the molecular orientation effect of septithiophene (Septithiophene의 배향 특성에 관한 연구)

  • Park, J.H.;Moon, J.H.;Lee, Y.S.;Choi, J.S.;Shin, D.M.;Cho, W.R.;Lee, S.D.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1724-1726
    • /
    • 2000
  • We have investigated a molecular orientation effect of septithiophene(7T), the conjugated linear septenary of thiophene, on its optical and electrical properties. Vacuum evaporation of septithiophene on a substrate induces a upright orientation. We rubbed the pre-layer to lie down molecules. As a result, we could get a horizontal molecular orientation. Dichroic ratio is about 2 at 418nm from UV/visible absorption spectrum. To investigate the electrical characteristics, we fabricated devices with septithiophene as a semiconducting material. The conductivity with horizontal septithiophene orientation is about one order gloater than that of upright septithiophene.

  • PDF

Technology Teachers' Motivation toward Teaching Biotechnology (생물기술교육에 대한 기술교사의 동기유발)

  • Kwon, Hyuksoo
    • 대한공업교육학회지
    • /
    • v.34 no.1
    • /
    • pp.252-273
    • /
    • 2009
  • Due to the importance of biotechnological literacy, the educational community in fields such as technology education, science education, and agricultural education has acknowledged the importance of biotechnology instruction for secondary school. Although recognized as a content organizer in the field of technology education, the actual teaching of biotechnology has not been broadly implemented in technology education classes. In the perspective of expectancy-value theory, technology teachers' motivation is the key factor for affecting the biotechnology instruction. This study investigates Korean technology teachers' motivational beliefs toward biotechnology and its instruction and their perceived ability and value toward biotechnology learning contents. To measure their motivational beliefs and attitudes, a composite on-line survey (fifteen motivational beliefs items, eight biotechnology content items, and related demographic items) was developed. Based on 114 Korean technology teachers' responses the researcher performed a descriptive analysis, independent t-test, and factor analyses (exploratory and confirmatory factor analysis using M-plus 5.0 and SPSS 16.0). Korean technology teachers' abilities toward eight biotechnology contents indicated lowscores while their values were relatively high. Through the independent sample t-test by two demographic variables (gender and professional development), this study found several significant differences in the perceived value. As a preliminary finding of exploratory factor analysis, fifteen items was separated into two motivational constructs of expectancy (6 items) and value (8 items). One item (item #6) was eliminated due to the cross loading. The final findings of this study may have significant implications for professional development regarding biotechnology and its instruction (both in-service and pre-service training) of technology teachers. Also, the confirmatory facctor analysis supported the preliminary finding. Finally, this study recommends that a validity test for other population, investigation for motivational sub-constructs, and in-depth investigation toward biotechnology instruction.

ESR-based Identification of Radiation-Induced Free Radicals in Gamma-Irradiated Basil and Clove Using Different Sample Pre-Treatments (감마선 조사된 바질과 정향의 전처리방법에 따른 ESR Spectra 판별 특성)

  • Kwak, Ji-Young;Ahn, Jae-Jun;Akram, Kashif;Kwon, Joong-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.10
    • /
    • pp.1454-1459
    • /
    • 2012
  • An improved detection of radiation-induced paramagnetic faults was developed to identify the irradiation status of basil and clove. The effectiveness of different sample pretreatments, including freeze-drying (FD), oven-drying (OD), alcoholic-extraction (AE), and water-washing and alcoholic-extraction (WAE), were examined. All non-irradiated samples showed a single central signal ($g_0$=2.006), whereas radicals representing two additional side peaks ($g_1$=2.023 and $g_2$=1.986) with a mutual distance of 6 mT were detected in the irradiated samples. AE and WAE produced the best results for irradiated clove in terms of intensities of radiation-specific ESR signals and their ratios to the central signal. However, FD provided the highest intensities of radiation-specific ESR signals for basil, whereas their ratios to the major signal were better in the cases of AE and WAE. Signal noise, particularly due to $Mn^{2+}$ signals, was observed, whereas it decreased in AE and WAE pretreatments. Based on our results, AE and WAE can improve the detection conditions for radiation-specific ESR signals in irradiated samples.

Aluminum Powder Metallurgy Current Status, Recent Research and Future Directions

  • Schaffer, Graham
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2001.11a
    • /
    • pp.7-7
    • /
    • 2001
  • The increasing interest in light weight materials coupled to the need for cost -effective processing have combined to create a significant opportunity for aluminum P/M. particularly in the automotive industry in order to reduce fuel emissions and improve fuel economy at affordable prices. Additional potential markets for Al PIM parts include hand tools. Where moving parts against gravity represents a challenge; and office machinery, where reciprocating forces are important. Aluminum PIM adds light weight, high compressibility. low sintering temperatures. easy machinability and good corrosion resistance to all advantages of conventional iron bm;ed P/rv1. Current commercial alloys are pre-mixed of either the AI-Si-Mg or AL-Cu-Mg-Si type and contain 1.5% ethylene bis-stearamide as an internal lubricant. The powder is compacted in closed dies at pressure of 200-500Mpa and sintered in nitrogen at temperatures between $580~630^{\circ}C$ in continuous muffle furnace. For some applications no further processing is required. although most applications require one or more secondary operations such as sizing and finishing. These sccondary operations improve the dimension. properties or appearance of the finished part. Aluminum is often considered difficult to sinter because of the presence of a stable surface oxide film. Removal of the oxide in iron and copper based is usually achieved through the use of reducing atmospheres. such as hydrogen or dissociated ammonia. In aluminum. this occurs in the solid st,lte through the partial reduction of the aluminum by magncsium to form spinel. This exposcs the underlying metal and facilitates sintering. It has recently been shown that < 0.2% Mg is all that is required. It is noteworthy that most aluminum pre-mixes contain at least 0.5% Mg. The sintering of aluminum alloys can be further enhanced by selective microalloying. Just 100ppm pf tin chnnges the liquid phase sintering kinetics of the 2xxx alloys to produce a tensile strength of 375Mpa. an increilse of nearly 20% over the unmodified alloy. The ductility is unnffected. A similar but different effect occurs by the addition of 100 ppm of Pb to 7xxx alloys. The lend changes the wetting characteristics of the sintering liquid which serves to increase the tensile strength to 440 Mpa. a 40% increase over unmodified aIloys. Current research is predominantly aimed at the development of metal matrix composites. which have a high specific modulus. good wear resistance and a tailorable coefficient of thermal expnnsion. By controlling particle clustering and by engineering the ceramic/matrix interface in order to enhance sintering. very attractive properties can be achicved in the ns-sintered state. I\t an ils-sintered density ilpproaching 99%. these new experimental alloys hnve a modulus of 130 Gpa and an ultimate tensile strength of 212 Mpa in the T4 temper. In contest. unreinforcecl aluminum has a modulus of just 70 Gpa.

  • PDF

Enhanced Transdermal Delivery of Procaine Hydrochloride by lontophoresis -Comparison of Synergic Effect of High Voltage Current and Ultrasound- (이온도입에 의한 염산프로카인의 경피전달 증대 -고전압전류 및 초음파 병행의 상승효과 비교-)

  • Lee, Jong-Sook;Kim, Kyoung-Won;Lee, Jae-Hyoung;Choi, Yeong-Wook;Lee, Jae-Hwi
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.3
    • /
    • pp.185-192
    • /
    • 2006
  • The purpose of this study was to determine the effects of iontophoresis on transdermal delivery of procaine hydrochloride in healthy volunteers, as well as to the synergic effect of high voltage current or ultrasound on the efficacy of transdermal delivery of iontophoresis. Forty healthy volunteers were randomly assigned to four groups topical application group (TA), iontophoresis group (IT), pre-treatment of high voltage current stimulation with iontophoresis (HVS + IT), and pre-treatment of ultrasound application with iontophoresis (US + IT). All subjects received procaine iontophoresis on the forearm using direct current with 4 mA f3r 15 minutes. All subject was measured the duration of local anesthesia, pressure pain threshold, pain perception threshold using rectangular wave at 0.2 ms, 1 ms, 50 ms of rectangular current stimulation after procaine iontophoresis. For comparisons of the sensory characteristics and efficacy of iontophoresis between the groups, an one-way ANOVA and Kruskal-Wallis were used. The significant difference the duration of local anesthesia were found between the groups (p<0.001). The local anesthetic duration of IT, HVS+IT were significantly longer than TA. Meanwhile, the local anesthetic duration of US+IT was significantly longer than HVS+IT, IT and TA group (p<0.05). Also, the pressure pain threshold, pain perception threshold at 0.2 ms, 1 ms, 50 ms were significant difference between the groups (p<0.001). All sensory characteristics including pressure pain threshold, pain perception threshold of IT, HVS+IT was significantly increased than TA, whereas, US+1T was significantly increased HVS+1T, IT and TA (p<0.05). This study showed that the procaine iontophoresis have increase the duration of local anesthesia concomitantly pressure pain threshold and pain perception threshold of sensory nerve fibers such as $A-{\beta}$, $A-{\delta}$ and C fiber. This findings suggest that the iontophoresis enhanced the transdermal delivery of drug ions in vivo. The combination of ultrasound application and iontophoresis synergized the transdermal delivery of drug ions. It is suggests that an electric field, mechanical and heating property of ultrasound may contribute to synergic effect due to temporary changes of structure in the stratum corneum.

The Value of Isotope Nephrography in Carcinoma of Cervix - Follow up Studies of Pre and Post Irradiation (자궁경부암(子宮頸部癌) 방사선치료(放射線治療) 전후(前後) Renogram의 의의(意義))

  • Yoo, H.S.;Suh, J.H.;Park, C.Y.;Choi, B.S.;Jung, S.O.;Kwak, H.M.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.9 no.1
    • /
    • pp.51-58
    • /
    • 1975
  • It is a great value to find an early detection of involvement of ureteric obstruction in the carcinoma of cervix. Little or no knowledge of the condition of the kidneys or the lower urinary tract are able to elucidate by the biochemical studies such as blood nitrogen or urine creatinine in carcinoma of cervix. Findings of urography delineates the condition of urinary tract stasis in the renal pelvis and ureters, however, slight stasis maybe difficult to demonstrate. On the other hand isotope nephrography is accepted as a sensitive method to observe renal function especially in regarding to the excretory function of kidney. It was attempted to analysis the findings of urography conjunction with isotope nephrography in 50 cases of unselected patients with invasive carcinoma of cervix through pre and post irradiation follow up studies. Urography was done as a routine procedure and.analysed emphasising changes of collecting systems and ureter condition. Isotope nephrography was carried out by means of $15{\mu}ci\;I^{131}$-Hippuran injected intravenously and the curves were analysed as follows. Parameter were; time of maximum amplitude ($T_{max}$), half time of maximum amplitude ($T\frac{1}{2}$), Kac and Kex value calculated from these two parameters in Tobe's method. The excretion index by Aurell defines the ratio between the maximum activity and the activity measured on the slope of the third phase ten minites after it has reached its maximum. Results: 1. 28.8% had an abnormal IVP suggestive of ureteric involvement before irradiation therapy and the patient of stage III and IV were the great part. 2. 21.7% had abnormal findings of per-irradiation renogram whom showed normal IVP. The other group showed normal IVP which group also showed normal renogram prior irradiation. 3. The more severe the ureteric involvement, the change of excretion index was greater. 4. Even in stage I and II patient, abnormal renogram was revealed in 12 cases (39.4%) among 31 cases. 5. All cases of TAH showed abnormal findings of IVP and renogram. 6. No. definite change of renogram was obtained just after the irradiation therapy (point $A:8000{\sim}9000rads,\;B:5000{\sim}6000rads,\;Co:11000{\sim}13000rads$). Each 3 month follow up study was performed and comparing with preirradiation study which showed significant changes of excretion index of renogram were 42.8% in $6{\sim}9$ month follow-up and 75% in $9{\sim}12$ month, respectively. 7. It seems to be important to observe the parameter Kex and excretion index of renogram to determine early abnormality of kidney excretory function by means of post-irradiation follow up study.

  • PDF

Study on Determination of Seven Transition Metal Ions in Water and Food by Microcolumn High-Performance Liquid Chromatography

  • Hu, Qiufen;Yang, Guangyu;Li, Haitao;Tai, Xi;Yin, Jiayuan
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.5
    • /
    • pp.694-698
    • /
    • 2004
  • A new method for the simultaneous determination of seven transition metal ions in water and food by microcolumn high-performance liquid chromatography has been developed. The lead, cadmium, mercury, nickel, cobalt, silver and tin ions were pre-column derivatized with tetra-(4-aminophenyl)-porphyrin ($T_4$-APP) to form the colored chelates which were then enriched by solid phase extraction with $C_{18}$ cartridge. The enrichment factor of 50 was achieved by eluted the retained chelates from the cartridge with tetrahydrofuran (THF). The chelates were separated on a ZORBAX Stable Bound microcolumn ($2.0{\times}50\;mm,\;1.8\;{\mu}m$)with methanol-tetrahydrofuran (95 : 5, v/v, containing 0.05 mol/L pyrrolidine-acetic acid buffer salt, pH = 10.0) as mobile phase at a flow rate of 0.5 mL/min and detected with a photodiode array detector from 350-600 nm. The seven chelates were separated completely within 2.0 min. The detection limits of lead, cadmium, mercury, nickel, cobalt, silver and tin are 4 ng/L, 3 ng/L, 6 ng/L, 5 ng/L, 5 ng/L, 6 ng/L, 4 ng/L respectively in the original samples. This method was applied to the determination of the seven transition metal in water and food samples with good results.

Characteristics of New Estrogen Biosensor Employing Taste Principles

  • Kwon, Soon-Bae;Lee, Cil-Han;Kim, Kyung-Nyun
    • International Journal of Oral Biology
    • /
    • v.36 no.2
    • /
    • pp.103-108
    • /
    • 2011
  • Measurement of estrogen concentration in bio-samples are very important for differential diagnosis of various disease or evaluation of health status. However, it is difficult to collect immediate data of estrogen concentration because they are measured by radioimmunoassay or chromatography which need time- and cost-consuming sample pre-treatment. This study was performed for development of new estrogen biosensor employing taste principles, and for evaluation of cross reactivity between various steroid hormones. Gene sequence of ligand binding domain of ${\alpha}$-human estrogen receptor (amino acid 302-553; hER-LBD) was cloned from human breast cancer cell line. The proteins of hER-LBD were produced by T7-E.coli expression system, and isolated by chromatography. hER-LBD were coated on the gold plated quartz crystal (AT-cut 9MHz), and resonance frequencies were measured by universal frequency counter. Estradiol, progesterone, testosterone, and aldosterone were used for cross reactivity of the hER-LBD. We also monitored influences of pH change in resonance frequency. The resonance frequencies of hER-LBD coated quartz crystal were decreased during increase of estrogen concentration from $15 \;{\mu}g/mL$ to $50\;{\mu}g/mL$. However, similar steroid hormones, progesterone and aldosterone, did not elicit the change in resonance frequency. Testosterone evoke weak change in resonance frequency. The new estrogen biosensor was more sensitive in pH 7.2 than in pH 7.6. These results suggest that hER-LBD coated quartz crystal biosensor is a probable estrogen biosensor.

Study on the Difference of Standardized Uptake Value in Fusion Image of Nuclear Medicine (핵의학 융합영상의 표준섭취계수 차이에 관한 연구)

  • Kim, Jung-Soo;Park, Chan-Rok
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.553-560
    • /
    • 2018
  • PET-CT and PET-MRI which integrates CT using ionized radiation and MRI using phenomena of magnetic resonance are determined to have the limitation to apply the semi-quantitative index, standardized uptake value (SUV), with the same level due to the fundamental differences of image capturing principle and reorganization, hence, their correlations were analyzed to provide their clinical information. To 30 study subjects maintaining pre-treatment, $^{18}F-FDG$ (5.18 MBq/㎏) was injected and they were scanned continuously without delaying time using $Biograph^{TM}$ mMR 3T (Siemens, Munich) and Biograph mCT 64 (Siemens, Germany), which is an integral type, under the optimized condition except the structural differences of both scanners. Upon the measurement results of $SUV_{max}$ setting volume region of interest with evenly distributed radioactive pharmaceuticals by captured images, $SUV_{max}$ mean values of PET-CT and PET-MRI were $2.94{\pm}0.55$ and $2.45{\pm}0.52$, respectively, and the value of PET-MRI was measured lower by $-20.85{\pm}7.26%$ than that of PET-CT. Also, there was a statistically significant difference in SUVs between two scanners (P<0.001), hence, SUV of PET-CT and PET-MRI cannot express the clinical meanings in the same level. Therefore, in case of the patients who undergo cross follow-up tests with PET-CT and PET-MRI, diagnostic information should be analyzed considering the conditions of SUV differences in both scanners.