• Title/Summary/Keyword: m-health

Search Result 8,235, Processing Time 0.035 seconds

Analysis of didecydimethylammonium chloride (DDAC) aerosol in inhalation chamber (흡입챔버 내 didecyldimethylammonium chloride(DDAC) 에어로졸의 분석)

  • Yang, Jeong-Sun;Choi, Sung-Bong;Park, Sang-Yong;Lee, Sung-Bae
    • Analytical Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.307-312
    • /
    • 2012
  • To perform inhalation toxicity test by using experiment animals, we set up an analytical method to monitor didecyldimethylammonium chloride (DDAC) in aerosol nebulized into inhalation chambers by ion chromatography. DDAC was adsorbed by XAD-2 resin and analyzed with conductivity detector. Recovery of DDAC desorbed by acetonitrile from XAD adsorbent was 87.8%. The method detection limit (MDL) and the limit of quantitation (LOQ) were 2.97 ${\mu}g/m^3$ and 8.92 ${\mu}g/m^3$, respectively. Repeatability was calculated as RSD 7.8% in the range of 0~20 ${\mu}g/mL$. Time needed to analyze a sample was less than 5 minutes. Therefore, the analysis of DDAC by ion chromatography was practically useful in monitoring DDAC in inhalation chambers with rapidity and sensitivity manner to perform inhalation toxicity test using experimental animals.

A Study on the Size of Ultrafine Particles and Heavy Metal Concentrations in the Atmosphere (일반대기 중 극미세입자와 중금속 농도에 관한 연구)

  • Cho, Tea-Jin;Jeon, Hye-Li;Youn, Hyung-Sun;Lee, Mi-Young;Son, Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.6
    • /
    • pp.480-495
    • /
    • 2010
  • This study evaluated the distribution of the concentrations of nano-particles and heavy metals (08-Pb, Cr, Zn, As, Fe, 09-Pb, Cr, Zn, Cu, Ni, Mn) in Seoul, Chungnam A and Gwangyang from August to December, in 2008 5 times each in the Seoul area, 5 times in and Chungnam A area and from August to November, in 2009 14 times in the Chungnam A area, 8 times in the Gwangyang area. The examined results showed high concentration level from $PM_1$ through $PM_{0.1}$ in all three areas. These results were obtained the concentration of particles by diameter and statistically significant in Stage5 (1.0-0.56 ${\mu}m$) from the result of conducting Kruskal-Wallis H test (p < 0.05). In the case of the heavy metal concentration included in 0.10-0.056 ${\mu}m$, 0.056 ${\mu}m$, the lead concentration of Chungnam Asan area was 6.49 ng/$m^3$ and 9.93 ng/$m^3$, which was higher than 3.05 ng/$m^3$ and 4.22 ng/$m^3$ of Seoul, respectively. The concentration of iron in Seoul was 9.28 ng/$m^3$ and 13.24 ng/$m^3$, that appeared higher than 2.38 ng/$m^3$ and 3.23 ng/$m^3$ of Chungnam A area, respectively. The concentration level was similar to other metals except lead and iron in Chungnam A area and Seoul. From the concentration of heavy metal included in 0.10-0.056 ${\mu}m$, 0.056 ${\mu}m$, the lead concentration of Chungnam A area was 0.31 ng/$m^3$ and 0.12 ng/$m^3$ while Gwangyang was 0.28 ng/$m^3$, 0.06 ng/$m^3$. Thus Chungnam A area showed higher lead concentration than Gwangyang. The manganese concentration of Chungnam A area was 0.12 ng/$m^3$ and 0.03 ng/$m^3$ while Gwangyang was 0.21 ng/$m^3$ and 0.08 ng/$m^3$. Therefore, the concentration of Gwangyang appeared higher than that of Chunnam A area. These two metals showed statistically significant in 0.056 ${\mu}m$ (p < 0.05, p < 0.01). Among the concentration of heavy metal in all regions, the result demonstrated that the order of higher concentration is arsenic > iron > zinc > chrome > lead > nickel > copper > manganese.

The Occupational Exposure Limit for Fluid Aerosol Generated in Metalworking Operations: Limitations and Recommendations

  • Park, Dong-Uk
    • Safety and Health at Work
    • /
    • v.3 no.1
    • /
    • pp.1-10
    • /
    • 2012
  • The aim of this review was to assess current knowledge related to the occupational exposure limit (OEL) for fluid aerosols including either mineral or chemical oil that are generated in metalworking operations, and to discuss whether their OEL can be appropriately used to prevent several health risks that may vary among metalworking fluid (MWF) types. The OEL (time-weighted average; 5 mg/$m^3$, short-term exposure limit ; 15 mg/$m^3$) has been applied to MWF aerosols without consideration of different fluid aerosol-size fractions. The OEL, is also based on the assumption that there are no significant differences in risk among fluid types, which may be contentious. Particularly, the health risks from exposure to water-soluble fluids may not have been sufficiently considered. Although adoption of The National Institute for Occupational Safety and Health's recommended exposure limit for MWF aerosol (0.5 mg/$m^3$ ) would be an effective step towards minimizing and evaluating the upper respiratory irritation that may be caused by neat or diluted MWF, this would fail to address the hazards (e.g., asthma and hypersensitivity pneumonitis) caused by microbial contaminants generated only by the use of water-soluble fluids. The absence of an OEL for the water-soluble fluids used in approximately 80-90 % of all applicants may result in limitations of the protection from health risks caused by exposure to those fluids.

Radiation Dose Distribution of a Surgeon and Medical Staff during Orthopedic Balloon Kyphoplasty in Japan

  • Ono, Koji;Kumasawa, Takafumi;Shimatani, Keiichi;Kanou, Masatoshi;Yamaguchi, Ichiro;Kunugita, Naoki
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.2
    • /
    • pp.86-92
    • /
    • 2022
  • Background: The present study investigated the radiation dose distribution of balloon kyphoplasty (BKP) among surgeons and medical staff, and this is the first research to observe such exposure in Japan. Materials and Methods: The study subjects were an orthopedic surgeon (n = 1) and surgical staff (n = 9) who intervened in BKP surgery performed at the National Hospital Organization Disaster Medical Center (Tokyo, Japan) between March 2019 and October 2019. Only disposable protective gloves (0.022 mmPb equivalent thickness or less) and trunk protectors were used, and no protective glasses or thyroid drapes were used. Results and Discussion: The surgery time per vertebral body was 36.2 minutes, and the fluoroscopic time was 6.8 minutes. The average exposure dose per vertebral body was 1.46 mSv for the finger (70 ㎛ dose equivalent), 0.24 mSv for the lens of the eye (3 mm dose equivalent), 0.11 mSv for the neck (10 mm dose equivalent), and 0.03 mSv for the chest (10 mm dose equivalent) under the protective suit.The estimated cumulative radiation exposure dose of 23 cases of BKP was calculated to be 50.37 mSv for the fingers, 8.27 mSv for the lens, 3.91 mSv for the neck, and 1.15 mSv for the chest. Conclusion: It is important to know the exposure dose of orthopedic surgeons, implement measures for exposure reduction, and verify the safety of daily use of radiation during surgery and examination.

The Effect of Health Education on the Performance of Health Promoting Behavior in E.M.T. Students (건강관련 과목이수가 대학생의 건강증진 생활양식에 미치는 변화에 관한 연구)

  • Lee, In-Soo;Choi, Eun-Sook
    • The Korean Journal of Emergency Medical Services
    • /
    • v.4 no.1
    • /
    • pp.7-16
    • /
    • 2000
  • The purpose of this study to test the effect of health education on the performance of health promoting behavior in E.M.T. students. The data were collected from 77 EMT students by questionnaire. The first survey were conducted from March 20 to April 2. The second survey were conducted from August 8 to September 5 on same group. The data were analyzed by pecentage, mean, t-test using SAS program. The result of this study were as follows : 1. The average item score for the health promoting was 2.35 at freshman. 2. The average item score for the health promoting was 2.59 after one year on same group. In the subcategories, the highest degree of performance was personal relationship support, self-actualization, stress management, nutrition and health responsibility and the lowest degree was sports. 3. Hypothesis that the EMT student who get health education will have a higher degree of health promoting behavior than the freshman EMT student was accepted.

  • PDF

THE MICROSOMAL EPOXIDE HYDROLASE(MEPHXS) POLYMORPHISMS AND THE ASSOCIATION OF MICRONUCLEI(MN) IN THE BENZENE-EXPOSED WORKERS

  • Kim, Tae-Yon;Kwon, Seul-A;Kim, Jin-Sik;Kim, Su-Young;Lee, Young-Jun;Chung, Eun-Jung;Paek, Do-Myung;Park, Jung-Keun;Chung, Hai-Won
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2002.05a
    • /
    • pp.134-134
    • /
    • 2002
  • In order to investigate whether genetic polymorphisms in the mEH exon3 (Tyr139His), exon4 (His113Arg) interact with the formation of MN in benzene exposed workers, the PCR-RFLP based genotyping of 76 exposed and 115 controls were performed and cytokinesis-block micronucleus (CBMN) analysis of 56 exposed and 53 controls was employed.(omitted)

  • PDF

Study of the Characteristics of Roasted Coffee Bean in Seoul (서울시 유통 원두커피의 품질 특성)

  • Cho, In-soon;Hong, Mi-sun;Lee, Eun-seon;Kim, Si-jung;Lee, Yong-cheol;Kim, Sung-dan;Jo, Han-bin;Kim, Jung-hun;Jung, Kweon
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.3
    • /
    • pp.236-241
    • /
    • 2015
  • This study was performed to survey and evaluate the contents of pH, total acidity, caffeine, harmful metals (Pb, Cd) and total polyphenol in coffee extraction. In total, coffee bean. Total fifty coffee samples were analysed. A 5 g portion of roasted ground coffee samples were extracted in coffee-maker with 100 mL of distilled water and the extraction were used in all experiments. The pH range was 4.72~5.25 (mean value = 4.99). According to increase of the roasting temperature, the pH were shown a tendency to increase. The contents of total acidity was 0.72~2.25% (mean value = 1.59%). According to increase of the roasting temperature, the contents of total acidity were shown a tendency to decrease. The contents of harmful metals (Pb, Cd) in coffee extractions were determined by ICP. The average contents of Pb and Cd were 0.0112 and 0.0011 mg/kg, respectively. The contents of caffeine in coffee extractions were determined by HPLC, the range of detection was 0.51~20.28 mg/mL (mean value = 12.29 mg/mL). According to increase of the roasting temperature, the contents of caffeine were shown a tendency to increase. The contents of total polyphenol in coffee extractions were determined by spectrophotometer, the range of detection was 18.88~43.90 mg/mL (mean value = 31.94 mg/mL). According to increase of the roasting temperature, the contents of total polypenol were shown a tendency to decrease.

Effects of Tributyltin Chloride on L-DOPA-Induced Cytotoxicity in PC12 Cells

  • Lee, Jae-Joon;Kim, Yu-Mi;Park, Seung-Kook;Lee, Myung-Koo
    • Archives of Pharmacal Research
    • /
    • v.29 no.8
    • /
    • pp.645-650
    • /
    • 2006
  • Tributyltin chloride (TBTC) at concentrations of $0.5-1.0\;{\mu}M$ inhibits dopamine biosynthesis in PC12 cells. In this study, the effects of TBTC on L-3,4-dihydroxyphenylalanine (L-DOPA)-induced cytotoxicity in PC12 cells were investigated. TBTC at concentrations up to $1.0\;{\mu}M$ neither affected cell viability, nor induced apoptosis after 24 or 48 h in PC12 cells. However, TBTC at concentrations higher than $2.0\;{\mu}M$ caused cytotoxicity through an apoptotic process. In addition, exposure of PC12 cells to non-cytotoxic (0.5 and $1.0\;{\mu}M$) or cytotoxic $(2.0\;{\mu}M)$ concentrations of TBTC in combination with L-DOPA (20, 50 and $100\;{\mu}M$) resulted in a significant increase in cell loss and the percentage of apoptotic cells after 24 or 48 h compared with TBTC or L-DOPA alone. The enhancing effects of TBTC on L-DOPA-induced cytotoxicity were concentration- and treatment time-dependent. These data demonstrate that TBTC enhances L-DOPA-induced cytotoxicity in PC 12 cells.

Propagation Characteristics and Effects of Road Traffic Noise (도로교통소음의 전파특성 및 영향)

  • Park, Joon-Cheol;Kim, Yoon-Shin;Kang, Dae-Joon
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.4
    • /
    • pp.311-315
    • /
    • 2008
  • This study was performed to investigate propagation characteristics and effects of road traffic noise generated from vehicles. Noise levels of expressway and general road were measured at four points in a straight line based on distance from the road, and analyzed. The average noise level of expressway was 78.9 dBA at 5 m, 76.4 dBA at 10 m, 72.0 dBA at 20 m, 69.0 dBA at 30 m. That of general road was lower about $3.1{\sim}3.5\;dBA$ than that of expressway. There was no significant difference in distance attenuation between expressway noise and general road noise. The farer the distance from source is, the more the attenuation is. The influence range of noise is assessed by noise environmental standards or road noise limits. Noise levels of the time zone were measured at a boundary line of apartment to grasp noise variation by time. The time zone of lowest noises was $3{\sim}4$ a.m. and that of highest noise was $8{\sim}10$ a.m. Data recorded on tapes were analyzed to understand the characteristics of frequency because these characteristics are important factors to plan the noise reduction measures, namely path measures.

Comparing Compliance and Efficacy of Isocaloric Oral Nutritional Supplementation Using 1.5 kcal/mL or 1 kcal/mL Sip Feeds in Mildly to Moderately Malnourished Indonesian Children: A Randomized Controlled Trial

  • Devaera, Yoga;Syaharutsa, Danny Maesadatu;Jatmiko, Herwasto Kuncoroyakti;Sjarif, Damayanti Rusli
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.21 no.4
    • /
    • pp.315-320
    • /
    • 2018
  • Purpose: This study set out to evaluate the compliance to, and efficacy of oral supplementation, using a 1.5 kcal/mL or 1 kcal/mL sip feed, in children with mild to moderate malnutrition. Methods: This was a parallel, randomized, controlled open-label trial in children aged 3 to 6 years with a weight for height Z (WHZ) score <-1 and ${\geq}-3$, who were randomized to receive a total of 600 kcal/day from either a 1.5 kcal/mL or a 1.0 kcal/mL pediatric sip feed for 28 days. Assessments included daily study product intake, body weight, tolerance and dietary intake from solid food. Results: Of 110 children recruited, 98 ($mean{\pm}standard$ deviation of age $49{\pm}7months$) completed the study. Both sip feeds were well tolerated, with high compliance ($80{\pm}24%$ and $81{\pm}22%$ of prescribed volume in 1.5 kcal/mL and 1.0 kcal/mL groups respectively, p=0.79). Both study groups gained similar weight during the 28 days intervention period ($0.42{\pm}0.40kg$ in 1.5 kcal/mL group vs. $0.49{\pm}0.49kg$ in 1.0 kcal/mL group, p=0.43). There were no significant differences between the groups in weight gain and in the change in WHZ score over the intervention period. Dietary analysis at the end of the study did not show replacement of solid food by the oral nutritional supplements. Conclusion: In children with mild to moderate malnutrition, both 1.5 kcal/mL and 1 kcal/mL pediatric sip feeds had high compliance and were well tolerated, and were equally effective in promoting weight gain in the 28 days study period.