• Title/Summary/Keyword: m-Health(Mobile Health)

Search Result 151, Processing Time 0.03 seconds

Development of a portable system for monitoring indoor particulate matter concentration (휴대용 실내 미세먼지 농도 측정 장치 개발)

  • Kim, Yoo Jin;Choi, Hyun Seul;Go, Taesik
    • Journal of the Korean Society of Visualization
    • /
    • v.20 no.1
    • /
    • pp.45-51
    • /
    • 2022
  • Airborne particulate matter(PM) has been a global environmental problem. PM whose diameter is smaller than 10 ㎛ can permeate respiratory organs and has harmful effects on human health. Therefore, PM monitoring systems are necessary for management of PM and prevention of PM-induced negative effects. Conventional PM monitoring techniques are expensive and cumbersome to handle. In the present study, two types of PM monitoring devices were designed for measuring indoor PM concentration, portably. We experimentally investigated the performance of three commercial PM concentration measurement sensors in a closed test chamber. As a result, PM2008 sensor showed the best PM concentration measurement accuracy. Linear regression method was applied to convert PM concentration value acquired from PM2008 sensor into ground truth value. A mobile application(app.) was also created for users to check the PM concentration, easily. The mobile app. also provides safety alarm when the PM10 concentration exceeds 81 ㎛/m3. The developed hand-held system enables the facile monitoring of surrounding air quality.

Method development and validation for dieckol in the standardization of phlorotannin preparations

  • Kim, Jiyoung;Um, Minyoung;Yang, Hyejin;Kim, Inho;Lee, Changho;Kim, Yuntai;Yoon, Minseok;Kim, Youngkyoung;Kim, Jimi;Cho, Suengmok
    • Fisheries and Aquatic Sciences
    • /
    • v.19 no.1
    • /
    • pp.3.1-3.6
    • /
    • 2016
  • Phlorotannins are reported to have diverse biological properties. However, no analytical methods for the standardization of phlorotannin preparations have been reported. Herein, we developed and validated an analytical method for the determination of dieckol in phlorotannin extracts (PRT) using high-performance liquid chromatography (HPLC). The optimum HPLC conditions consisted of a Supelco Discovery C18 column stationary phase, a mobile phase (A: 15 % HPLC grade methanol in deionized water, B: methanol), UV detection at 230 nm, and a flow rate of 0.7 mL/min. The optimized chromatographic conditions were validated and exhibited good specificity and linearity ($R^2$ > 0.9994-1.0000). The recoveries were in the range of 100.9-102.3 %. The method had good intermediate (%RSD 1.2) and intra-day (%RSD 0.4-1.7) assay precisions. This HPLC method had good accuracy and quality in the determination of dieckol in PRT.

Design of an Mobile Healthcare Manager for Interoperability (상호 운용성을 위한 모바일 헬스케어 매니저 설계)

  • Lee, Ku-Yeon;Park, Ju-Young;Lee, Chul-Ju;Kang, Kyung-Tae
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2014.11a
    • /
    • pp.313-314
    • /
    • 2014
  • 인구의 고령화로 만성질환자가 증가함에 따라 개인건강관리를 위한 U 헬스 서비스에 관심이 증대되고 있다. U 헬스 서비스를 활용하기 위해서는 다양한 생체정보를 간편하게 측정하는 개인건강기기(PHD, Personal Health Device)가 필요하다. 하지만 혈압, 심전도, 혈당, 산소포화도 등을 측정하는 개인건강기기는 제작 회사마다 서로 다른 프로토콜과 포맷으로 개발되어 기기간의 상호 운용성(Interoperability)이 보장되지 않는다. 또한 각기 다른 포맷으로 측정된 데이터를 병원정보시스템(HIS, Hospital Information System)간 공유하고 관리하는데 어려움이 존재한다. 이에 따라, 본 논문에서는 개인건강기기 국제 표준인 IEEE 11073 PHD 를 기반으로 다양한 개인건강기기와 실시간으로 통신하며, 측정된 생체정보를 관리하고 전송하는 모바일 헬스케어 매니저 설계를 제시한다. 제시한 매니저는 다양한 모바일 기기 중 스마트폰 기반으로 설계하였고, 각기 다른 포맷으로 측정된 데이터를 국제표준 메시지 교환방식인 HL7 (Health Level Seven)메시지로 변환하여 전달하는 게이트웨이 역할을 담당한다.

User Verification System using QRcode in Mobile Telemedicine Cloud Environment (모바일 원격의료 클라우드 환경에서 QRcode를 이용한 사용자 검증 시스템 연구)

  • Kim, Young-Hyuk;Lim, Il-Kwon;Lee, Jun-Woo;Li, QiGui;Lee, Jae-Kwang
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.11a
    • /
    • pp.858-861
    • /
    • 2011
  • Smart Society로 나아가는 핵심으로 손꼽히는 모바일의 급속한 확산은 교육, 교통, 경제뿐만 아니라 건강에도 큰 영향을 미치고 있다. 그동안 발전이 미진했던 u-Health 기술 및 시장 역시 모바일로 인해 새로운 서비스 모델을 제시함으로써 발전하고 있다. 본 논문은 제안하는 시스템은 u-Health 서비스 중 sensor를 이용하여 원격지 환자의 생체정보를 수집하고, 실시간으로 병원의 클라우드 서버에 전송하는 시스템에서 사용자 검증에 대하여 연구하였다. 여기서 사용자란 클라우드 서버에 접속하는 의사를 말하며, 환자의 생체정보를 보기 위하여 시스템 접속함에 있어 공인인증서나 기타 인증 시스템과 비교해 간편하고, 네트워크 트래픽이 적은 사용자 검증 시스템을 목표로 한다. 그리하여 QRcode를 3개 생성하고, 각 클라우드 서버에 분산 분배 후 서로 섞음으로써 기존의 QRcode와 전혀 다른 인증용 QRcode를 생성할 수 있었다. 이것을 3차원 인덱스를 통해 원본 사용자 QRcode와 대조함으로 사용자 검증 과정을 수행시킴으로써 절차를 간소화하고 네트워크 트래픽을 약 15% 감소시킬 수 있었다.

Development of Wireless Transmission and Receiver Module for the Management of Chronic Diseases (만성질환 관리를 위한 무선 송·수신기 모듈 개발)

  • Kim, Min Soo;Cho, Young Chang
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.1082-1087
    • /
    • 2019
  • In this study, ECG signal amplifier, wireless transmitter/receiver circuit, signal processing filter circuit and A/D converter circuit design required for the development of small sized ECG module for wireless transmission/ reception were performed. In order to verify the performance of ECG sensors, the measurement was performed from 1 m to 3 m to measure the signal noise ratio according to the gateway distance. Experimental results showed that the signal noise ratio at 2 m distance was 17.18 dB on average, which fulfilled the requirements for commercialization. The experimental results obtained in this study are expected to contribute to the low cost, high efficiency mobile health field where remote monitoring diagnosis can be applied to small biometric devices for chronic disease management.

The Mobile Health-Care Garment System for Measurement of Cardiorespiratory Signal (ECG와 호흡 측정이 가능한 모바일 헬스케어 의류 시스템)

  • Kim, Jeong-Do;Kim, Kap-Jin;Chung, Gi-Su;Lee, Jung-Hwan;Ahn, Jin-Ho;Lee, Sang-Goog
    • The KIPS Transactions:PartA
    • /
    • v.17A no.3
    • /
    • pp.145-152
    • /
    • 2010
  • Most wearable system for mobile healthcare applications consists of three parts. The first part is the sensing elements based on bio-signal, the second is the circuit module for control, data acquisition and wireless communication and control and the third is garment with a built-in electrodes and circuits. The existing healthcare garment systems have to find a solution to signal-wire and uncomfortable and inappropriate electrode to long-term attachment. Even if the wireless communication is used for healthcare garment system, the interface between sensors and circuits have to use wires. To solve these problems, this paper use electrode using PEDOT coated PVDF nanoweb for ECG signal and PVDF film sensor for respiratory signal. And, we constructed garment network using digital yarn of 10um, and transmitted ECG and respiratory signal to mobile phone through the integrated circuit with bluetooth called station To evaluate feasibility of the proposed mobile healthcare garment system, we experimented with transmission and measurement of ECG and respiratory signal using nanoweb electrode and digital yarn. We got a successful result without noise and attenuation.

Systematic Search and Qualitative Evaluation of Dietary Supplement Mobile Applications: Using the Mobile Application Rating Scale (MARS)

  • Hyeon Ji Lee;Si Hyun Seong;Hyunjin Chung;Yun Jeong Lee;Jae-Hyun Kim
    • Korean Journal of Clinical Pharmacy
    • /
    • v.33 no.1
    • /
    • pp.51-61
    • /
    • 2023
  • Background: Mobile applications (apps) on dietary supplements can increase consumers' access to information. However, it can lead to indiscriminate use of dietary supplements. This study aims to systematically review dietary supplement apps released in English and Korean and evaluate the quality of those apps. Methods: Through the app stores, apps on dietary supplements were systemically searched and examined. Two independent evaluators evaluated the apps and presented a mean score using the Mobile App Rating Scale (MARS). The correlation between MARS scores, user and evaluator ratings, and the number of secondary features of the apps were analyzed. Results: Of the 2,772 dietary supplement apps identified, 17 apps were included according to the selection criteria. The mean MARS score was 3.28 (standard deviation: 0.29) out of 5. Apps had higher scores in aesthetics and functionality dimensions, while engagement and information dimensions had lower scores. There was a positive correlation between the number of app downloads and information among MARS dimensions. The subjective evaluation also correlated with the information dimension. There was a positive correlation between the secondary features of the apps and MARS total score as well as the engagement dimension. Conclusion: The dietary supplement apps need to be managed at a higher level of quality to provide safe and reliable information to consumers. Especially, quality on information and engagement dimensions can be improved. Involvement of healthcare professionals in the app development, management with adequate referencing of information, and use of secondary features for enhanced user engagement can be helpful.

Privacy and Security Model for RFID Healthcare System in Wireless Communication Network (무선센서네트워크 환경하에서 RFID 헬스 시스템을 위한 보안 모델)

  • Kim, Jung-Tae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.6
    • /
    • pp.1223-1228
    • /
    • 2012
  • The use of a mobile agent in hospital environment offers an opportunity to deliver better services for patients and staffs. Furthermore, medical errors will be reduced because M-health system helps to verify the medical process. Optimized security protocols and mechanisms are employed for the high performance and security. Finally, a challenge in the near future will be converge the integration of Ubiquitous Sensor Network (USN) with security protocols for applying the hospital environment. We proposed secure authentication and protocol with Mobile Agent for ubiquitous sensor network under healthcare system surroundings.

Evaluation of the Usefulness of Virtual Reality Equipment for Relieving Patients' Anxiety during Whole-Body Bone Scan (전신 뼈 검사 환자의 불안감 해소를 위한 가상현실 장비의 유용성 평가)

  • Kim, Hae-Rin;Kim, Jung-Yul;Lee, Seung-Jae;Baek, Song-Ee;Kim, Jin-Gu;Kim, Ga-Yoon;Nam-Koong, Hyuk;Kang, Chun-Goo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.1
    • /
    • pp.27-32
    • /
    • 2022
  • Purpose When performing a whole-body bone scan, many patients are experiencing psychological difficulties due to the close distance to the detector. Recently, in the medical field, there is a report that using virtual reality (VR) equipment can give pain relief to pediatric patients with weak concentration or patients receiving severe treatment through a distraction method. Therefore, in this paper, VR equipment was used to provide psychological stability to patients during nuclear medicine tests, and it is intended to evaluate whether it can be used in clinical practice. Materials and Methods As VR equipment, ALLIP Z6 VR (ALLIP, Korea) was used and the experiment was conducted after connecting to a mobile phone. The subjects were 30 patients who underwent whole-body bone examination from September 1, 2021 to September 30, 2021. After intravenous injection of 99mTc-HDP, 3 to 6 hours later, VR equipment was put on and whole body images were obtained. After the test, a survey was conducted, and a Likert scale of 5 points was used for psychological anxiety and satisfaction with VR equipment. Hypothesis verification and reliability of the survey were analyzed using SPSS Statistics 25 (IBM, Corp., Armonk, NY, USA). Results Anxiety about the existing whole-body bone test was 3.03±1.53, whereas that of anxiety after wearing VR equipment was 2.0±1.21, indicating that anxiety decreased to 34%. When regression analysis of the effect of the patient's concentration on VR equipment on anxiety about the test, the B value was 0.750 (P<0.01) and the t value was 6.181 (P<0.01). decreased and showed an influence of 75%. In addition, overall satisfaction with VR equipment was 3.76±1.28, and the intention to reuse was 66%. The Cronbach α value of the reliability coefficient of the questionnaire was 0.901. Conclusion When using VR equipment, patients' attention was dispersed, anxiety was reduced, and psychological stability was found. In the future, as VR equipment technology develops, it is thought that if the equipment can be miniaturized and the resolution of VR content images is increased, it can be used in various clinical settings if it provides more realistic stability to the patient.

A Comparison of Sampling and Analytical Methods for Airborne Isocyanates (공기중 이소시아네이트류의 측정 및 분석방법에 관한 비교연구)

  • 변혜정;윤충식;백남원
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.2
    • /
    • pp.32-42
    • /
    • 1996
  • This study was performed to evaluate accuracy and precision of filter method and impinger method for analyzin airborne isocyanates in mixture (2, 6-TDI, HDI, 2, 4-TDI, MDI). Filter method was performed using the OSHA Method 42 and impinger method using the NIOSH Method 5521. The samples were analyzed by high performance liquid chromatography-ultraviolet detector (HPLC-UVD). After the optimum operating conditions for each method were investigated, samples with various concentration levels were quantified at the conditions. The precision was expressed by the pooled coefficient of variation(C.V.) and the accuracy by overall accuracy. The results are summarized as follows: 1. The optimum condition of filter method was determined at 35/65 ACN/buffer (0.01 M ammonium acetate) in mobile phase. And in case of impinger method, it was at 30/70 ACN/buffer(0.2 M sodium acetate). The effect of concentrations of acetate on the separation of the peaks was not significant, but, the effect of ACN/buffer ratio was significant. 2. The correlation coefficients for the two methods were above 0.9 in all isocyanate compounds. Average recovery efficiencies for 2, 6-TDI, HDI, 2, 4-TDI and MDI in filter method were 92.4%, 102.6%, 87.3% and 101.0%, respectively. Those in impinger method were 106.6%, 106.7%, 99.0% and 103.6%, respectively. As a result, the recovery efficiency of impinger method was higher than those of filter method in analyzing isocyanate compounds. 3. The pooled coefficients of variations of the methods were slightly higher than expected. The overall accuracies of the methods were within $\pm 25%$ for each isocyanate compound. Since these results satisfy NIOSH criteria, the accuracy of the experiment is appropriate. 4. As seen above, impinger method is more efficient than filter method. But, there are many disadvantages in impinger method. Therefore, solid sorbent such as a glass fiber filter must be developed in order to have the high efficiency not less than that of impinger method in the future.

  • PDF