• Title/Summary/Keyword: lying

Search Result 699, Processing Time 0.03 seconds

Activity Data Modeling and Visualization Method for Human Life Activity Recognition (인간의 일상동작 인식을 위한 동작 데이터 모델링과 가시화 기법)

  • Choi, Jung-In;Yong, Hwan-Seung
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.8
    • /
    • pp.1059-1066
    • /
    • 2012
  • With the development of Smartphone, Smartphone contains diverse functions including many sensors that can describe users' state. So there has been increased studies rapidly about activity recognition and life pattern recognition with Smartphone sensors. This research suggest modeling of the activity data to classify extracted data in existing activity recognition study. Activity data is divided into two parts: Physical activity and Logical Activity. In this paper, activity data modeling is theoretical analysis. We classified the basic activity(walking, standing, sitting, lying) as physical activity and the other activities including object, target and place as logical activity. After that we suggested a method of visualizing modeling data for users. Our approach will contribute to generalize human's life by modeling activity data. Also it can contribute to visualize user's activity data for existing activity recognition study.

A Study on the Development of the Nightgown Considering the Construction Features of the Cheolik and the Shimui (심의와 철릭을 활용한 나이트가운 개발에 관한 연구)

  • Kim, Hyun-Jeong;Cho, Oh-Soon;Kim, Yeo-Sook
    • Journal of the Korean Society of Costume
    • /
    • v.57 no.6 s.115
    • /
    • pp.1-16
    • /
    • 2007
  • The study aimed to develop the nightgown considering the construction and design features of the Shimui and the Cheolik. The analysis on the construction features of the Korean traditional costume and the physiological and motional attributes while sleeping resulted into the construction factors of the nightgown developed in the study. Consequently, the nightgown having these traditional Korean costume features were made for the evaluation. 4 different types of nightgowns were designed to be constructed. 20 professional clothing staff evaluated these 4 nightgowns developed and the existing nightgown used in the hotel industry. The results from the wearing test evaluation were: (1) to consider the stable closure of the gowns while wearing, the scores of the gowns developed were higher than the existing one. (2) the evaluations of the wearing comfort of the standing posture for the gowns developed and the existed were more or less similar but considering the lying down posture, the scores of the developed ones were significantly higher. (3) the gowns developed to have the wide-ham lines were considered more appropriate to the leg movement compared to the existing gown. The results from the fit and appearance test evaluation were: (1) throughout the all hight levels, the means of the gowns developed were higher than the existing gown's means in the most of the evaluation questions. (2) in the evaluation of the Korean traditional features, the gowns developed were more appropriate than the existing one. Consequently, the gowns developed were considered better to compare to the existing one in the context of postures, movements, comfort, appearance, fit, and design features.

Outcome of ultrasonographic imaging in infants with sacral dimple

  • Choi, Jin Hyuk;Lee, Taekwan;Kwon, Hyeok Hee;You, Sun Kyoung;Kang, Joon Won
    • Clinical and Experimental Pediatrics
    • /
    • v.61 no.6
    • /
    • pp.194-199
    • /
    • 2018
  • Purpose: Sacral dimples are a common cutaneous anomaly in infants. Spine ultrasonography (USG) is an effective and safe screening tool for patients with a sacral dimple. The aim of this study was to determine the clinical manifestations in patients with an isolated sacral dimple and to review the management of spinal cord abnormalities identified with USG. Methods: We reviewed clinical records and collected data on admissions for a sacral dimple from March 2014 through February 2017 that were evaluated with spine USG by a pediatric radiologist. During the same period, patients who were admitted for other complaints, but were found to have a sacral dimple were also included. Results: This study included 230 infants under 6-months-old (130 males and 100 females; mean age $52.8{\pm}42.6days$). Thirty-one infants with a sacral dimple had an echogenic filum terminale, and 57 children had a filar cyst. Twenty-seven patients had a low-lying spinal cord, and only one patient was suspected of having a tethered cord. Follow-up spine USG was performed in 28 patients, which showed normalization or insignificant change. Conclusion: In this study, all but one infant with a sacral dimple had benign imaging findings. USG can be recommended in infants with a sacral dimple for its convenience and safety.

Effects of Joint Position on the Distraction Distance in Patients with Adhesive Capsulitis of Glenohumeral Joint

  • Park, Sam Sik;Kim, Ki Do;Hwang, Yong Pil;Moon, Ok Kon;Kim, Bo Kyung;Choi, Wan Suk
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.6 no.1
    • /
    • pp.824-827
    • /
    • 2015
  • The purpose of this study was to investigate the effects of joint position on the distraction distance in patients with adhesive capsulitis of glenohumeral joint. The study was conducted upon 20 adults in their 40's with the findings of adhesive capsulitis of glenohumeral joint. These subjects were subdivided into 3 groups, which were a group with neutral position(n=7), second group with resting position(n=7) and third group with end-range position(n=6). After having the subject wearing sleeveless shirts exposing armpit and lying straight on the plinth, a physical therapist with OMT qualification pulled glenohumeral joint at the Grade III of Kaltenborn-Evjenth traction; and the distance between glenoid fossa and humeral head was measured with ultrasound. Following the application of traction, the group with resting position($.67{\pm}0.29$) exhibited the longest distance between humeral head and glenoid fossa, and it was followed by neutral position($.50{\pm}0.25$) and end-range position($.35{\pm}.21$) in this order. From the comparison of these groups, there was no significant difference in distraction distance between resting position and neutral position; and there was again no significant difference in distraction distance between end-range position and neutral position. However, there was a significant difference in distraction distance between end-range position and resting position(p<.05). Upon application of the Grade III of Kaltenborn-Evjenth traction, it was evident that the distance between humeral head and glenoid fossa can be varied depending on the location of the joint.

The Comprehension of Herpes Zoster and The Approach of Physical Therapy (대상포진 질환에 대한 이해와 물리치료적 접근)

  • Han, Jin-Tae;Choi, Young-Won;Lee, Youn-Koung;Yuk, Goon-Chang;Kweon, Oh-Hyun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.2 no.2
    • /
    • pp.205-212
    • /
    • 2007
  • Purpose : Herpes zoster is a common dermatologic disorder and is caused by reactivation of varicella zoster virus lying dormant in the ganglion of the dorsal root Methods : The aim of this study is to elucidate the clinical characteristics of herpes zoster and it's nature of pain, and is to review the method of physical therapy for pain control. Results : Herpes zoster is characterized by segmental rash, pain, and sensory symptoms, For most patients skin healing and pain resolution occur within 3-4 weeks, However, pain can continue after the rash has healed. Pain and paresthesia often the eruption of herpes zoster and vary from itching to stabbing. The preeruptive pain may simulate other diseases and may lead to misdiagnosis and misdirected interventions. Motor symptomatology is less well known and is most often related to central nervous system disease, although true lower motor neuron application is also thought to exist Subclinical motor involvement is relatively more common than clinical motor weakness and is easily detected by using electromyography. Higher incidences of herpes zoster were observed in female and in the elderly. Conclusion : The nature of pain associated with herpes zoster varied from a superficial itching to server stabbing or bursting, and paresthesia occurred most frequently. Therefore, the study of herpes zoster will be more research and comprehend, and the approach of physical therapy should be need positively.

  • PDF

Anomalous Arterial Supply to the Serratus Anterior Muscle (전방거근으로 분지되는 혈관경의 해부학적 변이 증례보고)

  • Goh, Tae Buhm;Lee, Jong Wook;Koh, Jang Hyu;Seo, Dong Kook;Choi, Jai Koo;Jang, Young Chul
    • Archives of Plastic Surgery
    • /
    • v.35 no.4
    • /
    • pp.487-490
    • /
    • 2008
  • Purpose: The latissimus dorsi flap and the serratus anterior flap have been used as combined flaps to reconstruct extensive defects. Because these two muscles are usually supplied by the subscapular-thoracodorsal vessels, the two flaps can be based on vascular pedicle that is long and anatomically reliable. In this case, we reported that serratus anterior possessed an anomalous arterial supply totally independent from the subscapular pedicle while raising combined latissimus dorsi and serratus anterior flap. Methods: A 35-year-old male with extensive soft tissue defect in the left perineum and thigh visited. Muscle defects of the medial thigh were observed, and femoral nerve and vessels were exposed. Combined latissimus dorsi and serratus anterior free flap was raised to reconstruct defect. On raising flaps, artery supplying the serratus anterior muscle originated from the axillary artery directly, was lying on the undersurface of the serratus anterior muscle. Results: Because two flap pedicles had no communication and latissimus dorsi muscle was large enough to cover soft tissue defect, we transferred only latissimus dorsi free flap with 1 : 3 meshed skin graft. Patient had limb salvage and satisfactory functional outcome. Conclusion: There are many variations of arterial pedicles of flaps. However, most of these variations remain within known anatomical consistence, thus is an indicator in planning the dissection of the vessels. According to documents, arterial pedicle to the serratus muscle not originated from the thoracodorsal artery is rarely reported, and in most of these cases, the arteries are originated from the subscapular artery. Thus pedicle directly originated from the axillary artery to serratus muscle is a very rare variation in its vascular anatomy.

Wireless Measurement of Human Motion Based on PDA (PDA기반 인체동작 무선계측)

  • Lee, Myong-Ho;Kim, Nam-Jin;Lee, Hwun-Jae;Jin, Gae-Whan;Lee, Sam-Ual;Lee, Jun-Hang;Lee, Sang-Bock;Lee, Tae-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.1
    • /
    • pp.39-44
    • /
    • 2007
  • In this study, wireless measurement technique for human motion was developed to monitor movement disorder patients during their daily life. MICA, TinyOS, and nesC, developed by UC Berkeley, were used as wireless sensor, its software platform, and programming language. The human motion data, generated by two axial accelerometer(ADXL202) was transmitted to PDA(iPaq3630) by 916Mhz short range communication chip(TR1000). It could be stored at PDA by simple Windows CE programming. To test the developed device, it was attached at human chest and the acquired data was shown as a graph during his motion of sitting, standing, and lying. The result showed that human motion could be logged without any hooking and constraints. Therefore, this device can be used to monitor patient's movement disorder and activity of daily life(ADL).

  • PDF

Relationship Between Subjective Fatigue Symptoms, Body Type and Health Awareness in Middle School Students (중학생의 피로자각증상과 체형 및 건강의식과의 관련성에 관한 연구)

  • Song, In Soon;Cho, Young Chae
    • Journal of the Korean Society of School Health
    • /
    • v.10 no.2
    • /
    • pp.169-178
    • /
    • 1997
  • In order to investigate the complaint rates of subjective fatigue symptoms and study the relationship between them and body type, health awareness in middle school students, we carried out a survey of 1,209 students (654 boy students and 555 girl students) at a middle school in Taejon City by a self-recorded questionnaire. The survey was conducted in June, 1997. The results obtained were as follows: 1. Among complaints of fatigue, "feel like lying down" was the highest, followed by "feel anxious about things", "feel drowsy", "yawning a lot", "eye strain" and "whole body feels tired" in descending order. 2. In the average weighted score of fatigue complaint, dullness and sleepiness (I) was the highest, followed by a difficulty in concentration (II) and bodily projection of fatigue (III) in descending order. Fatigue seems to create mental stress rather than physical burdens. 3. In the classification of body type based on the $R\ddot{o}hrer$ index, the obesity type (145 and above) was 11.0%, standard type (110~144) was 64.7% and leptosomic type (l09 and below) was 24.3%. Comparison between both sexes revealed that the rate of obesity and leptosomic types were significantly higher in boy students than in girl students. 4. In terms body type awareness, the statistics are the following: those who consider themselves to be standard type, 44.3%, slightly obese 24.5%, leptosomic, 23.5% and obese 7.8%. However, the level of obesity awareness was significantly higher in girl students than in boy students. 5. As for health awareness, 36.5% considered themselves healthy, 5.4% generally healthy and 10.1% a little unhealthy, but the level of unhealthy awareness was higher in girl students than in boy students. 6. In the relationship between body type and health awareness, most students thought that they were obese in spite of their standard body type. Also, many students who were obese and leptosomic tended to consider themselves to be a little unhealthy. 7. The more the students were obese or felt unhealthy, the more the average weighted score of fatigue complaints was high.

  • PDF

Electron Trapping and Transport in Poly(tetraphenyl)silole Siloxane of Quantum Well Structure

  • Choi, Jin-Kyu;Jang, Seung-Hyun;Kim, Ki-Jeong;Sohn, Hong-Lae;Jeong, Hyun-Dam
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.158-158
    • /
    • 2012
  • A new kind of organic-inorganic hybrid polymer, poly(tetraphenyl)silole siloxane (PSS), was invented and synthesized for realization of its unique charge trap properties. The organic portions consisting of (tetraphenyl)silole rings are responsible for electron trapping owing to their low-lying LUMO, while the Si-O-Si inorganic linkages of high HOMO-LUMO gap provide the intrachain energy barrier for controlling electron transport. Such an alternation of the organic and inorganic moieties in a polymer may give an interesting quantum well electronic structure in a molecule. The PSS thin film was fabricated by spin-coating of the PSS solution in THF organic solvent onto Si-wafer substrates and curing. The electron trapping of the PSS thin films was confirmed by the capacitance-voltage (C-V) measurements performed within the metal-insulator-semiconductor (MIS) device structure. And the quantum well electronic structure of the PSS thin film, which was thought to be the origin of the electron trapping, was investigated by a combination of theoretical and experimental methods: density functional theory (DFT) calculations in Gaussian03 package and spectroscopic techniques such as near edge X-ray absorption fine structure spectroscopy (NEXAFS) and photoemission spectroscopy (PES). The electron trapping properties of the PSS thin film of quantum well structure are closely related to intra- and inter-polymer chain electron transports. Among them, the intra-chain electron transport was theoretically studied using the Atomistix Toolkit (ATK) software based on the non-equilibrium Green's function (NEGF) method in conjunction with the DFT.

  • PDF

Development of a Coverall Design for Infant Body Shapes (유유아 체형에 적합한 커버롤 디자인 개발)

  • Lee, Yoon-Kyung;Kim, Min-Ja;Nam, Yun-Ja
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.34 no.2
    • /
    • pp.189-199
    • /
    • 2010
  • This study develops a coverall design for the body shape and movement of infants. This research analyzed these processes: 1. The current coverall styles preferred for infants. 2. The appropriate products for the real size, body shape, movement, and fit of infants. 3. The observations of the 6 months to 9 months movement and development of infants. 4. The design and creation of a new coverall base in this study, and to check the suitable test the developed coverall design for the infant. The result of this study are: A coverall for infants that lie or crawl on the floor must avoid opening in the center front and a gore has to be added at the crotch of the pants for the better movement of infants. These ways provide infants a neat appearance and easy movement. The test of developed designs shows that the developed coverall design covers the size gap of the trunk loop according to the growth of the infant and the movement of the legs; in addition it provides a positive aesthetic effect. The waistline in the developed coverall (a waistline that should exist lower than the body waistline of the infant) can reduce seam stress because the pressure of the seam line can be absorbed in a dipper. It is one of the suitable design points for infants lying prone all day long in this study.