• Title/Summary/Keyword: luminous source

Search Result 111, Processing Time 0.033 seconds

Projecting Performance of a Daylighting Source Based on Its Architectura Applications in the Open-Top Surface Structure (고심도 공간의 건축적 특성에 따른 자연집광 시스템의 조명원적 성능분석)

  • Kim, Gon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.9 no.1
    • /
    • pp.23-30
    • /
    • 2009
  • A lightcourt design is typically used to address issues concerning aesthetics, feeling, and mood. From the view point of environmental aspect, as an ecological shaft space, it plays a key role in controlling inner quality. In particularly, the lightcourt concept allows the exploitation of daylighting by bring natural light into the center of the building, thus eliminating dark deep spaces. Additionally, the lightcourt shades the inner space in summer. The amount of light available at the base of the lightcourt depends on a number of factors; translucency of the top, reflectance and the geometry of the space. In this paper is to exemplify a lightcourt configuration with a sloped wall. It promises the maximized a sense of freedom and daylighting availability. It is a matter of course that the lightcourt with open-top plays a role as a light source for the adjacent space to the lightcourt. A series of lighting simulation provides performance data of daylighting with changing photometric factors. For the case that a skylight is not available, an electric lighting design with metal halide lamps has been established to create luminous ceiling. As expected, a sloped lightcourt with open-top exposes its superiority of daylighting source. Ancillary considerations to enhance of daylighting potential for the adjacent space have been issued with performance data.

Calculation of correction factor in PLS luminous flux measurement with integrating sphere (적분구를 이용한 PLS 광속측정의 보정계수 산출 및 적용)

  • Lee, Jung-Wook;Park, Kyung-Hoon;Yoo, Jae-Kyu
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.13-15
    • /
    • 2006
  • This paper describes the problem generated in PLS luminous flux measurement with integrating sphere. In RS case, we don't use the center position of the sphere but side position for flux test The difference of the lamp position makes the luminous flux difference of same light source. We confirmed the phenomenon with three other kinds of lamps and ensured the repeatability and reliability of this work at two laboratories. finally, the correction factor which should be applied for the PLS test at Side position was calculated.

  • PDF

THE 3.3 MICRON PAH EMISSION OF THE MID-INFRARED EXCESS GALAXIES DISCOVERED BY THE AKARI MID-INFRARED ALL-SKY SURVEY

  • Yamada, R.;Oyabu, S.;Kaneda, H.;Yamagishi, M.;Ishihara, D.;Kim, J.H.;Im, M.;Toba, Y.;Matsuhara, H.
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.4
    • /
    • pp.299-300
    • /
    • 2012
  • We investigate the relation between star formation activity and PAH $3.3{\mu}m$ emission. Our targets are mid-infrared-excess galaxies selected from the AKARI all-sky survey point source catalog. We performed AKARI near-infrared spectroscopy for them. As a result, we obtained $2.5-5{\mu}m$spectra of 79 galaxies, and selected 35 star-forming galaxies out of them. Comparing the PAH $3.3{\mu}m$ luminosities with the infrared luminosities, we find a linear correlation between them. However, by adding the results from literatures for luminous infrared galaxies and ultra-luminous infrared galaxies that are more luminous than our sample, the ratio of the PAH to the infrared luminosity is found to decrease towards the luminous end.

Luminous efficiency's estimation method of transmitted light in lenses (렌즈에서 투과된 광의 시감도 추정 방법)

  • Kim, Yong-Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.163-168
    • /
    • 2003
  • The eye sensitivity in the difference conditions of a light source intensity consists of two functions by the receptor of cone and rod according to a wavelength. We derived a distribution function of $P{\lambda}=A{\cdot}e^{-({\lambda}-{\lambda}_u)^2/2W^2}$ using a respond probability of the receptor of cone-rod for a photon. It was well applied for a CIE eye's sensitivity curve of a wavelength. When there is lens In front of eye, luminous efficiency should be corrected. Transmission light which permeate to depends on absorption wavelength, and relationship of final luminous efficiency's estimation method is expressed by multiplication of luminous efficiency and transmittance intensity of lens. $$Pf({\lambda})=T({\lambda}){\cdot}P({\lambda})$$. The theory was applied to photopic and scopic vision with brown color lens.

  • PDF

A Research on the Preference to Luminous Colors by Trichromatic LED Module (3원색 LED 광원 모듈을 이용한 광색 선호도 조사)

  • Chung, Kang-Wha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.55-58
    • /
    • 2004
  • Recently the examples of a lighting design with LED source have increased rapidly, but there are few researches that are related to selecting luminous colors by LED. The research is that respondents operated color blender and got preference colors according to what they made, the colors were measured by chroma meter and marking CIE 1931 chromaticity diagram. Through the results of the research has made group preference for luminous colors. From now on, not only does it seem capable of using a designing a building-lighting to which LED but it will be actively applied to controlling with a digital technology for lighting design.

Analysis of the Correlation between Human Sensibility and Physical Property of luminous Sources -Focused on Response according to Character of Color Temperature by luminous Sources- (건축조명광원의 광학적 특성에 따른 인간의 감성반응 분석 -조명광원별 색온도 특성에 따른 반응을 중심으로-)

  • Lee, Jin-Sook;Oh, Do-Suk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.9-16
    • /
    • 2005
  • The purpose of this research is to acquire emotional data on luminous source by measuring and evaluating human emotional response to the change of the optical feature of luminous environment Luminous sources used in actual architectural space were selected with the optical feature of luminous soured then to measure and analysis human emotional response on Luminous Source. As a result of that 1) In the result of performance measurement by the item of the clear vision of an optic function the fluorescent lamp of daylight indicated the most excellent Performance. 2) In the item of fatigue and stress, the metal halide lamp and mercury lamp showed the most 3) In $\ulcorner$ suitable in light$\lrcorner$, $\ulcorner$a similar with daylight$\lrcorner$ adjective of the amenity item the fluorescent lamp of daylight which color temperature was high turned up to be high also, in $\ulcorner$brilliant$\lrcorner$, adjective, the metal halide lamp and mercury lamp turned up to be low. 4) In the result of factor analysis, three factors $\ulcorner$activity$\lrcorner$, $\ulcorner$potency$\lrcorner$, $\ulcorner$evaluation$\lrcorner$ were abstracted and $\ulcorner$activity$\lrcorner$ factor has the most influential on evaluating the mood of interior space. 5) For the affection in the mood evaluation by each luminous sources, $\ulcorner$activity$\lrcorner$ factor was the most influential by metal halide lamp and fluorescent lamp of daylight, $\ulcorner$potency$\lrcorner$ factor was most influential by kind of incandescent lamp, $\ulcorner$evaluation$\lrcorner$ factor was most influential by fluorescent lamp of low color temperature.

The Optical Characteristics of 240 W High Power LED Fish Luring Lamp (240W급 고출력 LED 집어등의 광학적 특성)

  • Bae, Jae-Hyun;An, Heui-Chun;Kim, Sang-Woo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.6
    • /
    • pp.681-687
    • /
    • 2013
  • This study analyzed characteristics of 240 W high power LED lamps by comparing with those of traditional metal halide lamps. In addition, it analyzed the propriety of LED lamps as a source of light, considering seawater transmission characteristics. When Applying white LED package with the color temperature color temperature of 6500K, a 240W-LED fishing lamp has a characteristics of the luminous angle to be expanded to ${\pm}45^{\circ}$, the illumination change was improved to 0.8, as well as the luminance efficiency was improved to 98.8lm/W. As results of comparison between one 1,500W-metal halide lamp and four 240W-LED lamp with considering a seawater transmission and a luminous efficiency of scotopic vision, the radiant flux of two lamps were almost equal level at 50m depth and the luminous flux was 5% higher LED lamp than metal-halide lamp even if only applying the luminous efficiency of scotopic vision. As the luminous flux of LED lmap was 14% higher than that of metal-halide lamp with applying the luminous efficiency of scotopic vision to radiant flux at 50m depth, so LED fishing lamp was verified to alternative possibility of metal-halide lamp.

Implementation of a Ad-Hoc based LED-IT-Sensor Integrated Streetlight with Selective Remote Control (선택적 원거리 점멸이 가능한 Ad-Hoc 기반의 LED-IT-센서 통합 가로등 시스템 개발)

  • Oh, Sun-Jin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.5
    • /
    • pp.19-25
    • /
    • 2011
  • With the issue of a Green IT Technology, studies on a environment-friendly luminous source that can reduce Carbon discharge and increase energy efficiency are actively progressed all over the world. Especially, with the problems of high oil price and environmental pollution, LED has made a great attention as a new luminous source that can replace the existing incandescent bulbs and fluorescent lights. In this paper, the proposed streetlight system becomes more intellectual by combining the low power consuming, high efficient, and high luminous LED module with a complex sensor module with temperature, humidity, illumination and motion sensors. Then, we design and implement the Ad-Hoc based LED-IT-Sensor integrated streetlight system that can maximize the energy savings efficiently with central monitoring system and selective remote dimming control by connecting them to the wireless ubiquitous sensor network(USN) using a Zigbee module.

Design of an Optical System for a Medium Luminous-Intensity Aircraft-Warning Light Using a LED Light Source and a Fresnel Lens (LED 광원과 프레넬 렌즈를 이용한 중광도 항공장애등 광학계 설계)

  • Park, Hyeon Joon;Choi, Seong Won;Kim, Jong Tae
    • New Physics: Sae Mulli
    • /
    • v.68 no.11
    • /
    • pp.1268-1274
    • /
    • 2018
  • Aircraft-warning lights are lights that are used to inform pilots in flight about the presence of buildings or dangerous objects. Currently, the light sources of most aircraft-warning lights have been replaced by light-emitting diodes (LEDs). However, the aircraft-warning lights that are installed do not meet the optical performance standards and may cause airplane collisions. Therefore, the use of such light poses a risk to aviation safety. In order to solve this problem, we designed a Fresnel lens with the same luminous intensity distribution ovef $360^{\circ}$ direction; thus, we collimated the light beam from the LED light source with a narrow beam divergence angle in the form of an array of aspheric pieces. After that, we designed and simulated an aircraft-warning-light optical system with a center luminous intensity of 20,000 cd and a vertical divergence angle of $3^{\circ}$ or more by optimizing the lens' tilt and the distance between the LED and the Fresnel lens.