New Sustain Electrode Structure for High Luminous Efficiency in AC PDP (AC PDP의 새로운 고효율 전극구조)

  • 박차수;최준영;최윤창;허정은;이영권;박정후
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.9
    • /
    • pp.475-480
    • /
    • 2004
  • One of the most important issues in AC PDP is the improvement of luminous efficiency. One possible method is to develop new sustain electrode shape showing high luminous efficiency. In this study, a new electrode shapehas a bridge is proposed in order to solve this problem. The experimental results show that the test panel with the suggested new electrode shape shows high luminance efficiency by 35.35% and low sustain voltage by 17V compared with the conventional structure.

Auxiliary Address Pulse Driving Scheme for Improving Luminance and Luminous Efficiency in 42-inch WVGA Plasma Display Panel

  • Park, Ki-Hyung;Lee, Eun-Cheol;Cho, Ki-Duck;Tae, Heung-Sik
    • Journal of Information Display
    • /
    • v.5 no.1
    • /
    • pp.16-21
    • /
    • 2004
  • The effects of an auxiliary address pulse driving scheme, in which an auxiliary short pulse is applied to the address electrode during a sustain-period, were examined under the various image patterns of the 42-inch WVGA ac-PDP. When the auxiliary address pulse driving scheme was applied, the luminance of the red, green and blue cells were measured respectively. And the luminance, luminous efficiency, and current were measured under the full-white pattern of the 42-inch ac-PDP. As a result, the luminance of blue cells was improved approximately by 17 %, whereas the luminous efficiency of the full-white pattern was improved approximately by 34 % without a misfiring discharge in comparison with conventional driving scheme.

The verification of Luminous flux of Reference illuminant for New light source by the calculated correction factor (보정계수 산출에 의한 신광원용 표준램프 광속의 검증)

  • Hwang, Myung-Keun;Shin, Sang-Wuk;Yi, Chin-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.369-372
    • /
    • 2009
  • When measuring the luminous flux of a light source at the integrating sphere photometer, it can know the luminous flux to compare the standard lamp with the specimen lamp at the same location. But in case of PLS(plasma lighting system, microwave discharged lamp), that two lamps are cannot be the same location. If the reference illuminant and specimen lamp are cannot measure identical location, we should measure the variation of the luminous flux. For the outcome we can turn out a correction factor to revise and reflect it. But the better way is calibrate the specimen lamp locate the identical location of reference illuminant measured. In this thesis, we've test to find the correction factor for consider that change the measuring location. And it turns out the correction factor. From this, it presents the result to make a select for the reference illuminant which is against the illuminant type for newly produce.

A study on the Improvement of the luminous efficiency with new sustaining electrode structurs in ac-PDPs (새로운 유지전극 구조에 의한 ac-PDP 에서의 효율 개선에 관한 연구)

  • Lee, Jae-Young;Shin, Joong-Hong;Park, Chung-Hoo;Cho, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1818-1820
    • /
    • 2000
  • Due to recent technology advances, needs for flat panel displays, plasma display panels(PDPs) whose advantages are simple structure, high resolution, wide viewing angle is increasingly expected to be the first flat panel of large screen, walt hanging TVs. But the luminance and luminous efficiency of color PDP is net up to the level of a CRT. So, New electrode shape which is different from the conventional electrode has to propose to improve the luminance and luminous efficiency. In this paper, we suggested new shaped electrodes. In new shaped electrode, the discharge current was reduced compared with conventional type by reducing the unnecessary diffusion loss near the barrier rib. However, the luminance was nearly the same as conventional type. So, the luminous efficiency improved about 35%.

  • PDF

The Optimum Phosphor Thickness to Obtain the Highest Luminance and Luminous Efficiency in ac PDP

  • Heo, Jeong-Eun;Kim, Young-Kee;Park, Hun-Gun;Park, Chung-Hoo
    • Journal of Information Display
    • /
    • v.2 no.1
    • /
    • pp.14-19
    • /
    • 2001
  • Plasma display panel(PDP) have gained great attention due to their potential application to large-area display including HDTV. The luminance and luminous efficiency of PDP, however, should be improved to realize this goal. In this study, we examined experimentally the effects of phosphor thickness and discharge gap on the luminance and luminous efficiency of ac PDP. For the rib height of 110 ${\mu}m$, whereas the optimum phosphor thickness was about 30 ${\mu}m$. The optimum thickness of green phosphor was about 50 ${\mu}m$ for the rib height of $120{\sim}160\;{\mu}m$.

  • PDF

Magnetic field effect on the positive column of fluorescent lamp (형광등 Positive column에 대한 자장인가 효과)

  • 지철근;김창종
    • 전기의세계
    • /
    • v.31 no.3
    • /
    • pp.197-203
    • /
    • 1982
  • The effects on the characteristics of 20-W fluorescent lamp were studied when applying magnetic field to its positive column. First, when the direction of the magnetic field is axial, i.e., along the lamp, if the magnitude of the field is stronger than the critical field, lamp voltage is increased, lamp current decreased, luminous flux increased, starting voltage decreased, as increasing the applied magnetic field. At the magnetic flux density is 130 gauss, luminous flux is increased to about 6 percents and starting voltage is increased to about 45 percents. Second, when the direction of the magnetic field is transverse to the lamp axis, as increasing the applied magnetic field, lamp voltage is increased, lamp current decreased, luminous flux increased and starting voltage is nearly constant, but the rates of increase or decrease of this case is different from those of the first. At the magnetic flux density is 300 gauss, luminous flux is increased about 45 percents. In both cases, electric power dissipated by lamps is the same as that of the lamp which magnetic field is not applied to.

  • PDF

Measurement and Analysis of Luminous Environment in Apartments (공동주택의 실내공간별 빛환경 측정 및 조명평면 분석)

  • Lee, Jung-Eun;Choi, An-Seop;Choi, Sung-Youl
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.19-23
    • /
    • 2004
  • Light is an environmental element which is essential for a man to live and do creative activities in residential area. Especially, modern people arc used to live under artificial light interior surroundings for much time. Currently, the average illumination level of the present apartment is improving, but it still does not reach the recommended level because the present apartment's luminous environment is only based on the life behavior which puts its priority to clear vision. Therefore, it is necessary that proper standard illumination must be used for various use and purpose. From this point of view, this paper investigated the essence of light in the residential area and the luminous environment for apartments was measured. This paper finally suggested well-coordinated lighting condition, derived from the measurement and analysis of luminous environment in these cases.

  • PDF

Analysis of Luminous Quantity Changes by the Dimming Control of the LED Lamp (조광제어에 의한 LED램프의 광특성 변화 분석)

  • Jang, In-Hyun;Kim, Yu-Sin;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.13-20
    • /
    • 2010
  • Until now, dimmable fluorescent luminaires has been widely used for dimming systems, and LED is currently attracting attentions as a alternative lamp due to environmental problem issues. LED, one of eco-friendly high efficiency lamp, has advantage that dimming is easy than fluorescent luminaire. But there have been not enough research on technical development and application for LED dimming. Therefore, to analyze luminous quantity of dimmable LED, the illuminance, color temperature, luminance, and current were measured in the whole range of dimming. In the results of this study, the dimmable LED of various types showed a similar trend in the changed luminous quantity by dimming.

The Race for TVs with Higher Luminous Efficiency

  • Weber, Larry F.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.3-10
    • /
    • 2005
  • The major display contenders: LCDs, CRTs, PDPs, projection displays, FEDs, SEDs and OLEDs are each examined in terms of the most critical display characteristic, the luminous efficiency. Each technology has great opportunity for improvement, but which one will win the race?

  • PDF

The Luminous Intensity and Luminaire Efficiency Analysis of White LED as Luminaire types for General Lighting (조명용 백색 LED광원의 등기구 형태에 따른 광도 및 기구효율 분석)

  • Hwang, Myung-Keun;Huh, Chang-Su;Seo, Yu-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.20-26
    • /
    • 2004
  • In this paper, luminaire optical efficiency and luminous intensity according to array of HB(high brightness) white LED(light emitting diode) and globe types of luminaire were simulated by computer and made a comparative analysis. LEDs were arranged by square of 7ea X 7ea. LED space has been divided into 8.2mm, 10mm and 15mm that mean distances between luminous centers of LEDs, and luminaire globes were classified into 30mm and 50mm 묘묘 from luminous center of LEDs. Also the simulations were made with / without globe, globe types were specified by convex and embossing types of which sizes are 8.2mm and 5.0mm, So total 27 classes of simulation were performed. This paper is to help luminire development using LED light source called digital lighting of 21th century, by studying luminire effciency and luminous intensity of different types of globes.