• 제목/요약/키워드: luminance performance

검색결과 293건 처리시간 0.026초

정지영상 데이터베이스의 효율적 인식자 생성 (Efficient Generation of Image Identifiers for Image Database)

  • 박제호
    • 반도체디스플레이기술학회지
    • /
    • 제10권3호
    • /
    • pp.89-94
    • /
    • 2011
  • The image identification methodology associates an image with a unique identifiable representation. Whenever the methodology regenerates an identifier for the same image, moreover, the newly created identifier needs to be consistent in terms of representation value. In this paper, we discuss a methodology for image identifier generation utilizing luminance correlation. We furthermore propose a method for performance enhancement of the image identifier generation. We also demonstrate the experimental evaluations for uniqueness and similarity analysis and performance improvement that have shown favorable results.

수직형 라이트파이프의 채광성능에 관한 예비평가 (Preliminary Field Test on Daylighting Performance of Perpendicular Light Pipe System)

  • 신혜미;박훈;김정태
    • KIEAE Journal
    • /
    • 제8권1호
    • /
    • pp.53-60
    • /
    • 2008
  • The daylighting affects on the human biological cycles and physiological alterations. Daylighting is also an important element in visual comfort and it sometimes influences the quality of vision. Therefore the absence of natural light during the day brings contradictory result. To solve the problems of natural light lack and provide sufficient daylight in interior spaces, it might be necessary to apply some daylighting systems. One of these systems, light pipe system, which is simple, cheep and easily constructed, is very useful to apply for small buildings. The light pipe is simple means of directing daylighting (diffuse and direct lighting)into interior space. In order to application of light pipe system in Korea, it is necessary to optical data of light pipe system. This study aims to evaluate preliminary experiment of the daylighting environment of light pipe system. Light pipe system, that aspect ratio is 1:2(diameter and length), was installed in a windowless mock-up with $27m^2$. The mock-up model was constructed as a prototype of Korean office surface. Illuminance was measured with a Topcon IM-5 Luxmeter to evaluate the distribution of the illuminance on a floor. The indoor and outdoor illuminance and the internal/external illuminance ratio are compared to discuss with in the graphs. Luminance was measured with Radiant imaging Promertric 1400 that is digital photometer to evaluate the distribution of luminance on interior surface. The contrast of luminance is discussed with table and graphs.

실물대모형 및 1/5, 1/10축소모형의 자연채광 성능평가에 관한 비교분석 (Comparative Daylighting Performance Analysis of Offices in 1/10, 1/5 Scale Models and Mock-up Model)

  • 백승헌;김정태
    • KIEAE Journal
    • /
    • 제6권4호
    • /
    • pp.25-32
    • /
    • 2006
  • Mock-up model can be applied to measure accurate performance data but difficult to apply the variables in experiment. There can be a slight experiment errors in Scale model, but various parameters can be applied for a objective experiment. This paper aims to compare the daylighting performance in 1, 1/5, 1/10 scale model of offices and analyze the experiment errors to certificate the influence of model experiment. To analyse daylighting performance, a comparison of a Mock-up model, sized $12.0m(w){\times}7.2m(l){\times}3.7m(h)$, designed for experimentation of daylighting systems and its 1:5, 1:10 scale model. It has an identical configuration of reference room and the test room. For the test room, the lightshelf system was designed as Micro-4 reflective material. To assess work plane illuminance and light factor, photometric sensors of each room were installed at work-plane(6 points) and exterior horizontal illuminance (1 point). And luminance of window, rare of the room was measured under clear sky. It is to be monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons with a light factor, increase-decrease ratio and luminance are discussed.

An Area Look-Up-Table based Controller for Improving Performance of Luminance on Lighting Passive Matrix Organic Light Emitting Diodes Panels

  • Juan, Chang-Jung;Tsai, Ming-Jong;Liu, Chia-Lin;Mo, Chi-Neng
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.II
    • /
    • pp.1487-1490
    • /
    • 2005
  • This study proposes a controller with the techniqu e of voltage -compensated driver for producing grayscaled pictures on passive matrix organic light emitting diodes (PMOLEDs) panels; especially, the controller overcomes the problem of luminance nonuniformity on displaying pictures. Because the controller is a voltage type driver, the output impedance of the driver is much less than that of the current-type driver. Hence, the controller provides a better electron-optical response than those of traditional current drivers. An area compensated look-up table (ACLUT) is designed in data feeding paths for removing luminance non-uniformity; thus, the proposed controller provides nearly 95% luminance uniformity.

  • PDF

터널 적용 바형식 반사거울시스템의 채광성능 평가 (Evaluation of daylighting performance of bar-type mirror reflector system in tunnel)

  • 이범석;주재성;정인영;김민성
    • 한국터널지하공간학회 논문집
    • /
    • 제14권1호
    • /
    • pp.93-105
    • /
    • 2012
  • 대부분의 터널 조명은 인공조명에 의존하고 있어 조명설비의 유지관리비 및 전력비를 절감하기 위해 자연채광을 적용한 기초연구가 선행되었다. 이에 본 연구는 터널 조경 바형식 반사거울시스템의 채광성능(조도, 휘도)을 평가하였다. 수평면 조도를 측정한 결과, 전체 평균 1,170 lx로 미설치 대비 6.5배 이상 증가하여 채광유효구간에서 구간별 터널기준조도(KSA 3703)를 만족시키는 것으로 나타났으며, 터널 밖으로 나오는 반대편 차로 운전자의 휘도를 측정하여 분석한 결과, 전체 평균 3.01로 현휘 기준치인 10 이내로 평가되어 눈부심이 발생하지 않는 것으로 나타났다.

Xe 플라즈마 평판 램프의 전기적 특성 (Electricla Properties of Xe Plasma Flat Lamp)

  • 최용성;조재철;홍경진;이우선;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 광주전남지부
    • /
    • pp.35-38
    • /
    • 2006
  • As a display becomes large recently, Acquisition of high luminance and Luminance uniformity is becoming difficult in the existing CCFL or EEFL backlight system. So, study for a performance enhancement has enforced. but lamp development of flat type is asked for high luminance and a luminance uniformity security in of LCD and area anger trend ultimately. In this paper, we changed a tip shape of an electrode for production by the most suitable LCD backlight surface light source, and confirmed discharge characteristic along discharge gas pressure and voltage, and confirmed electric field distribution and discharge energy characteristic through a Maxwell 2D simulation. Therefore the discharge firing voltage characteristic showed a low characteristic than a rectangular type and round type in case of electrode which used tip of a triangle type, and displayed a discharge electric current as a same voltage was low.

  • PDF

효율적인 비디오 유사도 측정을 위한 휘도 투영모델 (Luminance Projection Model for Efficient Video Similarity Measure)

  • 김상현
    • 융합신호처리학회논문지
    • /
    • 제10권2호
    • /
    • pp.132-135
    • /
    • 2009
  • 비디오 데이터들의 효율적 색인과 검색을 위해서는 비디오 시퀀스의 유사도 측정방법이 매우 중요한 요소이다. 본 논문은 비디오 시퀀스에 대한 효율적인 유사도 측정을 위해 휘도 성분 투사법을 제안한다. 기존의 알고리즘들이 히스토그램, 윤곽선, 움직임등과 같은 특성을 사용한 반면 본 논문에서 제안한 알고리즘은 휘도 성분을 투사하는 방법을 사용하여 비디오 유사도 특성을 효율적으로 나타낼 수 있다. 비디오 데이터의 효율적인 색인과 계산량 감소를 위해 누적된 유사도에 의해 추출된 키프레임들을 이용하여 비디오 시퀀스의 유사도를 구하고 수정된 하우스도르프 거리를 사용하여 키프레임 묶음들의 유사도를 측정하였다. 실험결과 제안한 휘도투시법을 사용한 비디오 색인 기법이 유사도 특성에서 기존의 특성을 사용한 방법에 비해 확연한 정확도 및 성능 차이를 보였다.

  • PDF

비파괴검사 장치 내 방사선원 위치감시용 섬광필름의 발광성능 평가 (Evaluation of luminance performance of scintillating film for monitoring the position of a radioactive source in an NDT apparatus)

  • 이경진;윤정익;박병기;김신;이봉수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제28권1호
    • /
    • pp.13-17
    • /
    • 2005
  • 최근 비파괴검사 현장에서 검사 중 검사장치 내 방사선원의 위치를 확인하지 못하여 방사선 과피폭 사고가 종종 발생하고 있다. 본 연구는 방사선원의 노출여부나 위치 미인지로 인한 방사선 사고를 예방하기 위해 방사선원위치를 감시할 수 있는 섬광필름을 개발하는데 있다. 섬광필름은 방사선 비파괴 검사 장비의 가이드튜브 내에 존재하는 선원의 위치를 육안으로 탐지할 수 있는 신소재이다. 연구를 통해 섬광필름의 발광성능을 평가하고 최적의 필름 설계를 꾀하였다. 필름에 적용된 발광물질은 무기 섬광체를 이용하였고, 다양한 층을 갖는 형태의 필름을 제작하여 성능을 평가하였다. 필름의 발광성능은 광도계를 이용하여 측정하였고, 비파괴 검사장비는 Ir-192 감마선 조사기를 사용하였다. 실험결과, 섬광필름의 발광은 육안으로 선원의 위치를 감시할 수 있었으며, 선원의 이동에 따라서 발광영역도 동시에 이동하면서 형성되었다. 또한, 섬광필름에 반사층을 두는 것은 광 이용률의 증대시켜 발광성능을 높이는 데 매우 효과적이었다. 섬광체와 분산용제의 혼합비에 따라서도 성능변화가 나타났으며, 일반적으로 섬광체의 양이 높을수록 발광성능은 높게 나타났다. 그러나 분산 특성이 변화로 혼합비는 일정 농도 이하로 제한되었다. 섬광체 중에서는 $Gd_2O_2S(Tb)$ 무기섬광체가 가장 높은 발광성능을 보여주었다. 개발된 섬광필름을 비파괴 검사 장비에 적용하게 된다면 방사선종사자에게 보다 안전한 작업환경을 제공할 수 있을 것이다.

  • PDF

Controller with Voltage-Compensated Driver for Lighting Passive Matrix Organic Light Emitting Diodes Panels

  • Juan, Chang Jung;Tsai, Ming Jong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.673-675
    • /
    • 2004
  • This study proposes controller with voltage-compensated drivers for producing gray-scaled pictures on passive matrix organic light emitting diodes (PMOLEDs) panels. The controller includes voltage type drivers so the output impedance of the driver is far less than that of the current-type driver. Its low output impedance provides better electron-optical properties than those of traditional current drivers. A free running clock and a group of counters are applied to the gray-scaled function so that phase lock loop (PLL) circuit can be reduced in the controller. A pre-charge function is used to enhance performance of the luminance of an active OLED pixel. As a result, distribution of the low gray level portion is achieved linear relationship with input data. In this work, the digital part of the proposed controller is implemented using FPGA chips, and analog parts are combined with a digital-analog converter (DAC) and analog switches. A still image is displayed on a $48^{\ast}64$ PMOLEDs panel to assess the luminance performance fir the controller. Based on its cost requirement and luminance performance, the controller is qualified to join the market for driving PMOLEDs panels.

  • PDF

야간의 도로조명 상황에서 최적의 도로조명기준을 나타낼 수 있는 가로등의 설계와 배치에 관한 연구 (Design and Installations of Road Lighting for Arterial Roads to Provide the Optimal Values of Light Technical Parameters)

  • 김기혁
    • 대한교통학회지
    • /
    • 제9권2호
    • /
    • pp.41-56
    • /
    • 1991
  • The aim of this research is designing road lighting installations(arrangement, mounting height spacing and overhang) which produce a certain level and distribution of luminance together with minimal glare. These can be varied over a limited range for a given luminance and road surface to achieve the required installation performance. In Korea there are no code of practice which lays down recommended performance criteria (Lavg, Uo, Ul, G, TI) with practical design guidance on how to achieve them. In case study design rules and current installation of road lighting in daegu city are analysed. The core of research are suggesting a new performance criteria and providing a set of table giving the maximum lognitudinal spacing between successive luminaires. The result of this research prescribes the combination of height and spacing for various road widths and arrangements which will achieve a specified minimum performance on straigt roads for particular luminaire and a particular road surf-ace.

  • PDF