• 제목/요약/키워드: luminance/discharge characteristics

검색결과 108건 처리시간 0.027초

형광체 두께와 방전공간의 변화에 따른 ac PDP의 어드레싱 속도와 전기광학적 특성에 관한 연구 (The Study of Addressing Time and Electrical and Optical Characteristics as Phosphor Thickness and Height of discharge Space in ac-PDP)

  • 허정은;김규섭;박정후;조정수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1815-1817
    • /
    • 2000
  • Plasma display Panels(PDPs) are one of the leading technologies currently under development for large-area high-brightness flat panel displays. However, the luminance and luminous efficiency of at PDPs should be improved. Especially, one of the main factors affecting on the luminance and luminous efficiency of ac PDP may be the phosphor thickness and size of discharge space. In this study, we examined into addressing time, electrical and optical properties as a parameter of the phosphor thickness and the size of discharge space during the display period of ac PDP. It is found out that the optimum phosphor thickness was $50{\mu}m$ and height of discharge space was about $100{\mu}m$.

  • PDF

AC PDP의 저온에서의 오방전 개선을 위한 구동 방법 (Driving Method for Mis-discharge Improvement at Low Temperature in AC PDP)

  • 김근수;이석현
    • 전기학회논문지
    • /
    • 제58권6호
    • /
    • pp.1157-1165
    • /
    • 2009
  • In AC-PDP, it is necessary to achieve high luminance efficiency, high luminance and high definition by adopting technologies such as high xenon concentration, MgO doping, and long gap. However, it is very difficult to apply above technologies because they make the driving voltage margin reduced. Especially, high Xe concentration technology for high efficacy makes not only the driving voltage margin reduced but also the stability of reset discharge decreased at low temperature. In this paper, we studied temperature and voltage dependent stability of reset discharge and present the experimental results of the discharge characteristics at low temperature. In addition, we suggested the mechanism of bright noise and black noise at low temperature. Finally, we proposed double reset waveform to improve the bright noise and descending scan time method to improve the black noise.

Emission Characteristics of Discharge Tube with Mixed Gases

  • Jo, Ju-Ung;Park, Yong-Sung;Lee, Jong-Chan;Masaharu Aono;Park, Dae-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권4호
    • /
    • pp.136-139
    • /
    • 2003
  • The positive column of a discharge tube filled with a mixture of mercury-xenon has a tendency to become contracted at room temperature. However, once the tube temperature is raised over 50 [$^{\circ}C$], the positive column changes from a contracted state to a diffused state. The xenon emission is stronger in the contracted positive column than in the diffused column. Alternatively, the mercury emission is more intense in the diffused positive column, and the luminance of the phosphor coating on the inner surface of the tube is higher than that in the contracted positive column. Moreover, higher luminance can be obtained by increasing the xenon pressure.

Long Gap Hump 전극구조를 가진 ac PDP에서의 Xe-Ne 가스의 방전 특성 연구 (A Study of Discharge Characteristics in Xe-Ne Gas Mixture for ac PDP with Long Gap Hump Electrode)

  • 허종철;옥정우;이돈규;이해준;이호준;박정후
    • 전기학회논문지
    • /
    • 제58권1호
    • /
    • pp.155-159
    • /
    • 2009
  • To increase the luminance and luminous efficacy in the discharge for alternating current plasma display panel (ac PDP), the increment of Xe contents and long discharge gap are necessary. However, the driving voltage and the cost of driving circuit increases in the high Xe contents and long discharge path condition. In this paper, a long gap ITO hump electrode (LGH) model for discharge cells of ac PDP is evaluated in the various Xe contents($5{\sim}20%$). The discharge voltage of LGH structure is lower about 30V than that of ITa reference structure with same main discharge gap. The LGH structure has lower power consumption and higher luminance than those of reference structure, respectively. Also, the luminous efficacy of LGH structure is higher about 20% than that of ITO reference structure in the 20% Xe contents.

플라즈마 방전 클러스터를 이용한 플렉시블 백라이트 유닛 연구 (A Study of Flexible BLU Using Plasma Discharge Ouster)

  • 유시홍;구교욱;이성의
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.324-325
    • /
    • 2008
  • In this Study, We fabricated a plasma discharge cluster with external electrodes which can be applied to flexible backlight in a polymer substrate and investigated the discharge characteristics. The Sealing process was progressed in vacuum chamber, which enable to fabricate plasma discharge cluster. The results of discharge characteristics show that the static memory margin of plasma discharge cluster was increased, as Ne/Xe(5%) gas pressure was increased. also, When gas pressure was 100torr at 600um of electrode gap, we have obtained high luminance of a plasma discharge cluster.

  • PDF

Effects of Aging Treatment of doped-MgO Layer on Discharge Characteristics of ac-PDP

  • Park, Kyung-Hyun;Ko, Min-Soo;Yoon, Sang-Hoon;Kim, Yong-Seog
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.216-219
    • /
    • 2007
  • Effects of aging treatment of doped-MgO electron emission layer on luminance efficiency of ac-PDP were investigated in this study. Morphological and luminance efficiency with aging treatment were examined, especially with emphasis on the effects of doping elements. The results indicate that the luminance efficiency of test panels depends on the type of doping elements used for MgO and that may be due to the redeposition of MgO during glow discharge.

  • PDF

EEFL의 주파수 변화에 따른 전기적 특성과 휘도특성 (Luminance Properties and Electrical Properties by Applied Frequency of External Electrode Fluorescent Lamp(EEFL))

  • 이성진;이종찬;박노준;박대희
    • 전기학회논문지
    • /
    • 제56권2호
    • /
    • pp.355-360
    • /
    • 2007
  • The recent TFT-LCD Trend that is done large size gradually. As size of monitor great, though problem happens, it is that consumer's request which it makes monitor combined TV function. Monitor and TV are no difference externally greatly, but define difference happens as for backlight. An external electrode fluorescent lamp (EEFL) has an advantage of a long lifetime in the early stages of the study on plasma discharge, interest in the lamp continues. Researches on the operation of external electrode fluorescent lamps have focused mainly on its use of a type of high frequency (MHz). By performing high Luminance using a square wave operation method with the low frequency below 100kHz, which is applied to a narrowed tube type lamp that has several mm of lamp diameter, EEFL presented the possibility of using it as a light source for back-lights. However, because EEFL generates plasma using wall charges, which considers the impedance characteristics of glass based on the structural principle in discharge, it can be significantly affected by frequency. Thus, this study verified the change in the characteristics of electromagnetic fields according to the change in frequency through a Maxwell electromagnetic field simulation and examined the relationship between the change in the EEFL frequency and Luminance by measuring the optical characteristics.

Effects of Phosphor Layer Morphology on Discharge Characteristics of Red, Green, and Blue Cells in AC-PDP

  • Lee, Jae-Jin;Jang, Sang-Hun;Tae, Heung-Sik;Choi, Kyung-Cheol
    • Journal of Information Display
    • /
    • 제2권4호
    • /
    • pp.52-56
    • /
    • 2001
  • This paper presents the effects of the phosphor layer morphology related to the discharge volume on the discharge and radiation characteristics of the Red, Green, and Blue cells in an AC-PDP. As the thickness of the phosphor layer increases and the corresponding discharge volume in the cells decreases, the voltage margin decreases due to an increase in the sustain voltage. In contrast, the IR(Infrared) emission, discharge current, and luminance characteristics remain almost unchanged, regardless of any changes in the phosphor layer morphology.

  • PDF

AC PDP의 전기광학적 특성에 미치는 동작 Gas Xex+Ne1-x의 영향 (The Effect of Working Gas Xex+Ne1-x on the Electro-optical Characteristics of AC PDP)

  • 박정후;유수복;이돈규;이해준;이호준;김재성
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.142-146
    • /
    • 2007
  • Nowadays, itis inevitable trend to use high Xe gas contents for increase luminous efficiency and luminance in plasma display panel. However, the increase of Xe gas contents causes the driving voltage, although the brightness is increase. In this paper, we study the characteristics of electro optical according to Xe gas contents and gas pressure. Electro-optical characteristics were investigated by the discharge voltage, luminance and luminous efficacy measurements, respectively. With some increasing Xe gas contents and pressure, the electro-optical properties increased. However, the characteristics of electro-optical begin to be saturated, when too high increased Xe gas contents and pressure.

Relationship between Image Retention and Time Lag in an AC PDP

  • Do, Yun-Seon;Jang, Cheol;Choi, Kyung-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.613-616
    • /
    • 2007
  • Characteristics of dark image retention and address discharge time lag were investigated simultaneously. It was found that reset waveforms with low black luminance did not guarantee lower image retention. Improved address discharge time lag due to modified reset waveforms similarly did not show improved image retention. The address discharge time lag and the image retention are in a trade-off relation.

  • PDF