• Title/Summary/Keyword: lower half

Search Result 1,310, Processing Time 0.026 seconds

A Study on the Characteristics of Cylinder Wake Placed in Thermally Stratified Flow (I) (열성층유동장에 놓인 원주후류의 특성에 대한 연구 (1))

  • 김경천;정양범;김상기
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.3
    • /
    • pp.690-700
    • /
    • 1994
  • The effects of thermal stratification on the flow of a stratified fluid past a circular cylinder were examined in a wind tunnel. In order to produce strong thermal stratifications, a compact heat exchanger type variable electric heater is employed. Linear temperature gradient of up to $250^{\circ}C/m$ can be well sustained. The velocity and temperature profiles in the cylinder wake with a strong thermal gradient of $200^{\circ}C/m$ were measured and the smoke wire flow visualization method was used to investigate the wake characteristics. It is found that the temperature field effects as an active contaminant, so that the mean velocity and temperature profiles can not sustain their symmetricity about the wake centerline when such a strong thermal gradient is superimposed. It is evident that the turbulent mixing in the upper half section is stronger than that of the lower half of the wake in a stably stratified flow.

A Study on the Garment Ease for Pre-School Children's Upper Clothing Construction (취학전 아동의 상의구성을 위한 여유량 연구)

  • 박찬미;서미아
    • The Research Journal of the Costume Culture
    • /
    • v.1 no.2
    • /
    • pp.145-157
    • /
    • 1993
  • This study aimes to investigate the garment ease of pe-school children's clothing in accordance with arm movement. The experiment was done with 4 per-school children fro mage 3 to age 5, and 3 types of experimental clothes were made ; sleeveless, half sleeve, and long sleeve. The waist pattern and the sleeve pattern of each experimental clothes has no garment ease. And experimental clothes were examined to obtain the necessary ease of armcye line and waist lien by cross-cut method. The results of investigation can be summarized as follows ; 1. The resulting movement ranges of experimental clothes with no garment ease were 131.5°(sleeveless), 71.75°(half sleeve), and 62.25°(long sleeve). 2. The size order of cross-cut opening of waist lien movement were (side>front>back), and (half sleeve>long sleeve>sleeveless). 3. When the base point of measurement was set to armpit point by arm the latitudinal length of cross-cut opening of armcye line by arm movement was (anterior armpit part > posterior armpit part), and longitudinal length of cross-cut opening was (upper part>lower part).

  • PDF

Dispersion of shear wave in a pre-stressed hetrogeneous orthotropic layer over a pre-stressed anisotropic porous half-space with self-weight

  • Kakar, Rajneesh;Kakar, Shikha
    • Structural Engineering and Mechanics
    • /
    • v.59 no.6
    • /
    • pp.951-972
    • /
    • 2016
  • The purpose of this study is to illustrate the propagation of the shear waves (SH-waves) in a prestressed hetrogeneous orthotropic media overlying a pre-stressed anisotropic porous half-space with self weight. It is considered that the compressive initial stress, mass density and moduli of rigidity of the upper layer are space dependent. The proposed model is solved to obtain the different dispersion relations for the SH-wave in the elastic-porous medium of different properties. The effects of compressive and tensile stresses along with the heterogeneity, porosity, Biot's gravity parameter on the dispersion of SH-wave are shown numerically. The wave analysis further indicates that the technical parameters of upper and lower half-space affect the wave velocity significantly. The results may be useful to understand the nature of seismic wave propagation in geophysical applications and in the field of earthquake and material science engineering.

Compensation of Effects of DC-Link Ripple Voltages on Output Voltage of Two-Leg Three-Phase PWM Inverters (2-레그 3상 PWM 인버터의 출력전압에서 직류링크 리플전압의 영향 보상)

  • Kim Young-Sin;Lee Dong-Choon;Seok Jul-Ki
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.1
    • /
    • pp.47-53
    • /
    • 2006
  • In this paper, a simple scheme compensating for the effect of dc-link ripple voltages on output voltage of two-leg and three-phase PWM inverters is proposed, where single-phase half-bridge PWM convertor and two-leg inverter are used. The voltage at neutral point of the dc-link is controlled so that the upper-half of do-link voltage is equal to the lower-half voltage in average concept. However, the effect of the do-link ripple voltage results in the inverter output voltage and current distortion. This effect can be eliminated by introducing a compensation voltage in switching time calculation. Also, the inverter dead time should be compensated for sinusoidal output waveform. The proposed scheme has been verified by experimental results which were obtained from the V/F constant operation of the induction motor fed by two-leg inverter.

Half Load-Cycle Worked Dual SEPIC Single-Stage Inverter

  • Chen, Rong;Zhang, Jia-Sheng;Liu, Wei;Zheng, Chang-Ming
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.143-149
    • /
    • 2016
  • The two-stage converter is widely used in traditional DC/AC inverter. It has several disadvantages such as complex topology, large volume and high loss. In order to overcome these shortcomings, a novel half load-cycle worked dual SEPIC single-stage inverter, which is based on the analysis of the relationship between input and output voltages of SEPIC converters operating in the discontinuous conduction mode (DCM), is presented in this paper. The traditional single-stage inverter has remarkable advantages in small and medium power applications, but it can’t realize boost DC/AC output directly. Besides one pre-boost DC/DC converter is needed between the DC source and the traditional single-stage inverter. A novel DC/AC inverter without pre-boost DC/DC converter, which is comprised of two SEPIC converters, is studied. The output of dual SEPIC converters is connected with anti-parallel and half load-cycle control is used to realize boost and buck DC/AC output directly and work properly, whatever the DC input voltage is higher or lower than the AC output voltage. The working principle, parameter selection and the control strategy of the inverters are analyzed in this paper. Simulation and experiment results verify the feasibility of the new inverter.

Ecotoxicity Assessment of Potassium Hydrogen Phthalate and Verification of Standard Reference Toxicity Test Method Using Potassium Hydrogen Phthalate

  • Dong Jin Choi
    • Proceedings of the National Institute of Ecology of the Republic of Korea
    • /
    • v.4 no.1
    • /
    • pp.49-62
    • /
    • 2023
  • Phthalates are animal carcinogens. Potassium hydrogen phthalate (KHP), which has the least complicated structure among phthalates, is used for the analysis of total organic carbon and formaldehyde. However, its toxicity has not been confirmed. A 24-hour acute toxicity test was performed using Daphnia magna, a water flea used to evaluate aquatic toxicity owing to its high sensitivity. The lowest observed effect concentration of KHP was found to be 240 mg/L. The effects of phosphorus, nitrogen, and Cr(6+), which are able to be discharged along with KHP, were also confirmed using tests. At 240 mg/L KHP, toxicity increased as phosphorus, nitrogen, and Cr(6+) increased. In addition, tests were performed to confirm the half maximal effective concentration of KHP. Through 10 test repetitions, the average ecotoxicity value was found to be 0.3, the average half maximal effective concentration was 327.75 mg/L, and the coefficient of variation (%) was 3.16%; because the latter value is lower than 25%, which is what is generally suggested for the water pollution standard method, the reproducibility of the tests is sufficient to replace the existing standard reference toxicity test that uses potassium dichromate. In addition, the half maximum effective concentration of potassium hydrogen phthalate is approximately 218 times more than that of potassium dichromate; therefore, toxicity is relatively low. In conclusion, KHP is a feasible alternative to the highly toxic potassium dichromate for performing the standard reference toxicity test.

A FLUOROSCOPIC STUDY ON THE STABILITY OF SKIN REFERENCE POINTS DURING JAW OPENING AND CLOSING MOVEMENT (방사선 투시를 이용한 개폐구 운동에 따른 수직 고경 계측점의 안정성에 관한 연구)

  • Ahn, Hyung-Jun;Kim, Chang-Whe;Kim, Yung-Soo;Kim, Yong-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.516-530
    • /
    • 1999
  • The current clinical technique for occlusal vertical dimension recording is based on marking the skin reference points on the patient's face and measuring between these points using caliper-like device. And it is difficult to achieve reliable measurements by this technique because of movable soft tissue. The purpose of this study is to reveal the stability of skin reference points by comparing the relative movement between extra-oral skin reference points and intra-oral reference points using X-ray fluoroscope. 10 test subjects were divided into 2 groups : Group I (natural dentition) and Group II (denture-wearer whose vertical dimension was lost) and Group III consists of identical test subjects to Group II with their upper denture removed and record base inserted. Attaching the 3 mm diameter steel ball to nose tip, lower lip, chin and to existing denture (or record base), fluoroscopic examination and recording were taken during 2 jaw opening and closing movements. After subsequent digitization using personal computer, 1219 still pictures with 0.1 second interval were made. Using the 2 dimensional graphic software, measurements between reference points were executed. Dividing the entire jaw movement into 3 ranges (total, 1st half opening, 2nd half opening), rate of movement and relative movement between extra-oral and intra-oral reference points were calculated and statistically analyzed. The results of this study are as follows. 1 Within the same experimental group, no statistical difference was found in the stability of skin reference between lower lip point and chin point during total range of jaw opening and closing movement (p>.05) 2. In the first half range of jaw opening, statistical difference was found between Group I (natural dentition) and Group II (denture wearer) (p<.05) Group I has greater skin reference stability than Group II. 3. In the first half range of jaw opening, statistical difference was found between Group I and Group III (record base wearer) (p<.05). Group I has greater skin reference stability than Group III. 4. In the first half range of jaw opening, no statistical difference was found in the stability of skin reference between Group II and Group III (p>.05). 5. In the second half range of jaw opening, no statistical difference was found in the stability of skin reference between any experimental groups (p>.05). 6. In patients with their occlusal vertical dimension lost, employing other measuring references rather than skin is recommended because of low stability.

  • PDF

Analyses on the Initial Charge-Discharge Characteristics of Half and Full Cells for the Lithium Secondary Battery using by the Gradual Increasing of State of Charge(GISOC) (충전용량점증분석법(GISOC)에 의한 리튬이차전지 Half Cell 및 Full Cell의 초기 충방전 특성 분석)

  • 도칠훈;진봉수;문성인;윤문수
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.2
    • /
    • pp.53-61
    • /
    • 2004
  • Characteristics of half cells of graphite/lithium and LiCoO$_2$/lithium, and full cells of graphite/LiCoO$_2$/ were analyzed by the use of GISOC(the gradual increasing of the state of charge). GISOC analyses generated IIE(the initial intercalation efficiency), which represents lithium intercalation property of the electrode material, and IIC$_{s}$(the initial irreversible capacity by the surface), which represents irreversible reaction between the electrode surface and electrolyte. Linear-fit range of graphite and LiCo/O$_2$electrodes were respectively 370 and 150 mAh/g based on material weight. IIE of graphite and LiCo/O$_2$electrodes were respectively 93∼94 % and 94∼95 %, and IICs of graphite and LiCo/O$_2$electrodes were 15∼17 mAH/g and 0.3∼1.7 mAh/g, respectively. IIE of graphite/LiCo/O$_2$full cell for GX25 and DJG311 as graphite showed 89∼90 %, which IIE value was lower than IIE of half cell of the cathode and the anode. Parameters of IIE and IIC$_{s}$ can also be used to represent not only half cell but also full cell. The characteristics of the full cell can be simulated through the correlative interpretation of potential profile, IIE, and IIC$_{s}$ of half cells.cells.

$Ca^{++}$ Polls in Isolated Rabbit and Turtle Heart (적출된 토끼와 자라심장에서의 $Ca^{++}$ Pool)

  • Kim, In-Kyo;Lee, Joong-Woo;Kang, Doo-Hee
    • The Korean Journal of Physiology
    • /
    • v.9 no.1
    • /
    • pp.13-22
    • /
    • 1975
  • From the study of movements of $Ca^{++}$ in frog cardiac muscle, Niedergerke (1963) postulated that $Ca^{++}$ necessary for the cardiac contraction is stored in a specific pool. Langer et al (1967) and DeCaro (1967) also found a close relationship between the change of $Ca^{++}$ flux kinetics and the change of contractile force. According to the studies of several investigators, Ca II (Bailey and Dressel 1968) or phase I and II (Langer 1965, Langer et al 1967, 1971) in the $Ca^{++}$ washout curve was associated with cardiac contractility. This investigation was aimed to elucidate the anatomical region of the contractile active $Ca^{++}$ pool. At the same time, it was assumed in this study that $Ca^{++}$ in the sarcoplasmic reticulumn represents one of the major intracellular $Ca^{++}$ pool and cardiac contractility was also dependent on the intracellular $Ca^{++}$ concentration. Consequently, this experiment was performed at different temperatures to activate to activate inhibit the deactivating process of activated $Ca^{++}$ in the intracellular space to see if changes in the contractility decay curve existed at different temperatures. The isolated hearts of rabbits and turtles (Amyda maackii) were attached to the perfusion apparatus according to the method employed by Bailey and Dressel (1968). The isolated hearts were initally perfused with a full Ringer solution containing 2 mg/ml of inulin for 1 hr, and then $Ca^{++}$ and inulin-free Ringer solution was perfused while the isometric tension was recorded and a serial sample of perfusion fluid dripping from the cardiac apex was collected for 10 sec throughout experimental period. The above procedure was performed at $23^{\circ}C$, $30^{\circ}C$ and $38^{\circ}C$ on the rabbit heart and $10{\sim}13^{\circ}C$, $10^{\circ}C$, $25^{\circ}C$, $30^{\circ}C$ and $35^{\circ}C$ on the turtle heart. After determination of $Ca^{++}$ and inulin concentration of the samples, the $Ca^{++}$, inulin washout curve and the contractile tensin decay curve were analysed according to the method of Riggs (1963). The results were summarized as follows; 1. In the rabbit heart, there are 2 inulin compartments, 3 $Ca^{++}$ compartments and sing1e exponential decay of contractile tension. In the turtle heart, there are $1{\sim}2$ inulin compartments, $1{\sim}2$ $Ca^{++}$ compartments and $1{\sim}2$ phases of contractile tension decay. The fact that the inulin space was divided into 3 compartments in the washout curve in these hearts indicates the presence of heterogeneity in cardiac perfusion, i.e., overfused and underperfused area. 2. Ca I a9d Ca II in these hearts were found to have $Ca^{++}$ in the ECF compartments because their half times in the washout curves were far smaller than those of the inulin washout curves in the rabbit heart and similar to those of the inulin washout curves in the turtle heart. Ca III in the rabbit heart may have originated from the intracellular $Ca^{++}$ store. But no Ca III in the turtle heart was found. This may be due to the fact that the iutracellular $Ca^{++}$ pool in the turtle heart was too small to detect using this experimental procedure since sarcoplasmic reticulumn in the turtle heart is poorly developed. 3. In the rabbit heart, there were no chages in the half time of Ca I, Ca II, inulin I and inulin II at different temperatures, but the half time of Ca III was significantly prolonged at lower temperatures, and the half time of the contractile tension decay tended to be prolonged at lower temperatures but this was not significant. In the turtle heart, there were no changes in the half time of Ca I, Ca II, inulin 1, inulin II and phase I of the contractile tension decay at different temperatures, but the half time of phase II of the contractile tension decay was significantly prolonged at lower temperatures. This finding indicates that intracellu!ar $Ca^{++}$ in these hearts was also responsible particulary for maintaining the cardiac contractility at the lower temperatures. 4. The half times of contractile tension decay were shorter than those of Ca II in the $Ca^{++}$ washout curves in both animal hearts. According to the above results it was shown that $Ca^{++}$ in ECF is primarily and $Ca^{++}$ in the intracellular space is partially associated with the cardic contractility.

  • PDF