• 제목/요약/키워드: low-strength concrete

Search Result 1,248, Processing Time 0.029 seconds

Experimental study on RC frame structures strengthened by externally-anchored PC wall panels

  • Choi, Seung-Ho;Hwang, Jin-Ha;Lee, Deuck Hang;Kim, Kang Su;Zhang, Dichuan;Kim, Jong Ryeol
    • Computers and Concrete
    • /
    • v.22 no.4
    • /
    • pp.383-393
    • /
    • 2018
  • Infill wall strengthening method has been widely used for seismic strengthening of deteriorated reinforced concrete (RC) frame structures with non-seismic details. Although such infill wall method can ensure sufficient lateral strengths of RC frame structures deteriorated in seismic performances with a low constructional cost, it generally requires quite cumbersome construction works due to its complex connection details between an infill wall and existing RC frame. In this study, an advanced seismic strengthening method using externally-anchored precast wall panels (EPCW) was developed to overcome the disadvantage inherent in the existing infill wall strengthening method. A total of four RC frame specimens were carefully designed and fabricated. Cyclic loading tests were then conducted to examine seismic performances of RC frame specimens strengthened using the EPCW method. Two specimens were fully strengthened using stocky precast wall panels with different connection details while one specimen was strengthened only in column perimeter with slender precast wall panels. Test results showed that the strength, stiffness, and energy dissipation capacity of RC frame specimens strengthened by EPCWs were improved compared to control frame specimens without strengthening.

Drying Shrinkage Properties of Latex Modified Concrete with Water-Cement Ratios (라텍스개질 콘크리트의 물-시멘트비에 따른 건조수축 특성)

  • Jeong, Won-Kyong;Kim, Seong-Hwan;Kim, Dong-Ho;Lee, Joo-Hyung;Lee, Bong-Hak
    • Journal of Industrial Technology
    • /
    • v.22 no.A
    • /
    • pp.193-200
    • /
    • 2002
  • Drying shrinkage cracking which may be caused by the relatively large specific surface IS a matter of grave concern for latex modified concrete(LMC) overlay and rapid-setting cement latex modified concrete(RSLMC) overlay. LMC and RSLMC were studied for field applications very actively in terms of strength and durability in Korea. However, there were no considerations in drying shrinkage. Therefore, the purpose of this dissertation was to study the drying shrinkage properties of LMC and RSLMC with the main experimental variables such as cement types(ordinary portland cement, rapid setting cement), water-cement ratios and curing days at a same controlled environment of 60% of relative humidity and $20^{\circ}C$ of temperature The drying shrinkage for specimens was measured with a digital dial gauge of Demec. The test results showed that the drying shrinkage of LMC and RSLMC were considerably lower with low water-cement ratio, respectively This might be attributed to the interlocking of hydrated cement and aggregates by a film of latex particles, water retention due to hydrophobic, and colloidal properties of the latexes resulting in reduced water evaporation.

  • PDF

Effect of cover depth and rebar diameter on shrinkage behavior of ultra-high-performance fiber-reinforced concrete slabs

  • Yoo, Doo-Yeol;Kwon, Ki-Yeon;Yang, Jun-Mo;Yoon, Young-Soo
    • Structural Engineering and Mechanics
    • /
    • v.61 no.6
    • /
    • pp.711-719
    • /
    • 2017
  • This study investigates the effects of reinforcing bar diameter and cover depth on the shrinkage behavior of restrained ultra-high-performance fiber-reinforced concrete (UHPFRC) slabs. For this, twelve large-sized UHPFRC slabs with three different rebar diameters ($d_b=9.5$, 15.9, and 22.2 mm) and four different cover depths (h=5, 10, 20, and 30 mm) were fabricated. In addition, a large-sized UHPFRC slab without steel rebar was fabricated for evaluating degree of restraint. Test results revealed that the uses of steel rebar with a large diameter, leading to a larger reinforcement ratio, and a low cover depth are unfavorable regarding the restrained shrinkage performance of UHPFRC slabs, since a larger rebar diameter and a lower cover depth result in a higher degree of restraint. The shrinkage strain near the exposed surface was high because of water evaporation. However, below a depth of 18 mm, the shrinkage strain was seldom influenced by the cover depth; this was because of the very dense microstructure of UHPFRC. Finally, owing to their superior tensile strength, all UHPFRC slabs with steel rebars tested in this study showed no shrinkage cracks until 30 days.

The Effect of Heat Curing Methods on the Protection against Frost Damage at Early Age of the Concrete Under Extremely Cold Climate

  • Jung, Eun-Bong;Shin, Hyun-Sup;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.6
    • /
    • pp.513-521
    • /
    • 2013
  • This study aimed to examine whether heat curing methods of concrete subjected to $-10^{\circ}C$ could be effective by varying the combination of heating cable and surface heat insulations. Three different concrete specimens incorporating 30% fly ash with 50% W/B were fabricated to simulate wall, column and slab members with dimensions of $1600{\times}800{\times}200$ mm for slab, $800{\times}600{\times}200$ mm for wall and $800{\times}800{\times}800$ mm for column. For heat curing combinations, Type-1 specimens applied PE film for slab, plywood for wall and column curing. Type-2 specimens applied double layer bubble sheet (2LB) and heating coil for slab, and 50 mm styrofoam for wall and column curing. Type-3 specimen applied 2LB for slab, electrical heating mat for wall and column inside heating enclosure. The test results revealed that the temperature of Type 1 specimen dropped below $0^{\circ}C$ beginning at 48 hours after placement due to its poor heat insulating capability. Type 2 and 3 specimens maintained a temperature of around $5{\sim}10^{\circ}C$ after placement due to favorable heat insulating and thermal resistance.

Seismic Performance Evaluation of Existing Low-rise RC Frames with Non-seismic Detail (비내진상세를 가지는 기존 저층 철근콘크리트 골조의 내진거동평가)

  • Kim, Kyung Min;Lee, Sang Ho;Oh, Sang Hoon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.3
    • /
    • pp.97-105
    • /
    • 2013
  • In this paper, the a static experiment of on two reinforced concrete (RC) frame sub-assemblages was conducted to evaluate the seismic behaviors of existing RC frames that were not designed to support a seismic load. The specimens were a one span and actual-sized. One of them had two columns with the same stiffness, but the other had two columns with different stiffness values. As Regarding the test results, lots of many cracks occurred on the surfaces of the columns and beam-column joints for the two specimens, but the cover concrete splitting hardly occurred was minimal until the test ends. In the case of the specimen with the same stiffness offor the two columns, the flexural collapse of the left-side column occurred. However, in the case of the specimen with different stiffness values for of the two columns, the beam-column joint finally collapsed, even though the shear strength of the joint was designed to be strong enough to support the lateral collapse load. The nonlinear Nonlinear static analysis of the two specimens was also conducted using the uniaxial spring model, and the analytical results successfully simulated the nonlinear behaviour of the specimens in accordance with the test results.

Predicting the moment capacity of RC slabs with insulation materials exposed to fire by ANN

  • Erdem, Hakan
    • Structural Engineering and Mechanics
    • /
    • v.64 no.3
    • /
    • pp.339-346
    • /
    • 2017
  • Slabs prevent harmful effects of fire that may occur in any floor. However, it is necessary to protect the slabs from fire. Insulation materials may be appropriate to protect reinforced concrete (RC) slab from elevated temperature. In the present study, a model has been developed in artificial neural network (ANN) to predict the moment capacity ($M_r$) of RC slabs exposed to fire with insulation material. 672 data were obtained for ANN model through author's prepared program. Input layer in model consisted of seven input parameters; such as effective depth (d), ratio of d'/d, thermal conductivity coefficient ($k_{insulation}$), insulation materials thickness ($L_{insulation}$), reinforcement area ($A_{st}$), fire exposure time ($t_{\exp}$), and concrete compressive strength ($f_c$). The predicted $M_r$ by ANN was consistent with the obtained $M_r$ by author. It is proposed to ease computational complexity in determining $M_r$ using ANN. The effects of using insulation material on the moment capacity in RC slabs were also investigated. Insulating material with low thermal conductivity has been found to be more effective for durability to high temperature.

Effects of Quality of Fly Ash on the Engineering Properties of Poor Mix Mortar (빈배합 모르타르의 공학적 특성에 미치는 플라이애시 품질의 영향)

  • Moon, Byeong-Yong;Song, Yuan-Ru;Baek, Cheol;Song, Heung-Ho;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.49-50
    • /
    • 2016
  • Recently in Korea, some studies on concrete that mass quantity of additives are substituted in order to respond to the government's Low Carbon Green Growth Policy are being conducted. As on of additives, FA as an industrial by-product is used in a large quantity. However, In some of the domestic FA refineries, since some quantity of concrete without passing through the refining process is released for sales for the reasons of the shortening of production time and the cost reduction, etc., it exerts a bad influence on the quality of concrete. Therefore, in this study, there was implemented an experiment on the effects of using an extreme quality of FA which is available for distributing domestically on the engineering characteristics of lean mortar. As a result, it was found that the quality of FA exerts its effect on the compression strength bigger than the flow property or the air volume.

  • PDF

Seismic performance of a 10-story RC box-type wall building structure

  • Hwang, Kyung Ran;Lee, Han Seon
    • Earthquakes and Structures
    • /
    • v.9 no.6
    • /
    • pp.1193-1219
    • /
    • 2015
  • The purpose of this study is to evaluate the seismic performance of high-rise reinforced concrete (RC) box-type wall structures commonly used for most residential buildings in Korea. For this purpose, an analytical model was calibrated with the results of the earthquake simulation tests on a 1:5 scale 10-story distorted model. This calibrated model was then transformed to a true model. The performance of the true model in terms of the stiffness, strength, and damage distribution through inelastic energy dissipation was observed with reference to the earthquake simulation test results. The model showed high overstrength factors ranging from 3 to 4. The existence of slab in this box-type wall system changed the main resistance mode in the wall from bending moment to tension/compression coupled moment through membrane actions, and increased the overall resistance capacity by about 25~35%, in comparison with the common design practice of neglecting the slab's existence. The flexibility of foundation, which is also commonly neglected in the engineering design, contributes to 30~50% of the roof drift in the stiff direction containing many walls. The possibility of concrete spalling and reinforcement buckling and fracture under the maximum considered earthquake (MCE) in Korea appears to be very low when compared with the case of the 2010 Concepcion, Chile earthquake.

Effect of the Variation of Speccfic Gravity and the Addition of Water Repellent Agent on the Physical Properties of Autoclaved Lightweight Concrete (비중의 변화와 발수제 첨가가 경량기포콘크리트의 물성에 미치는 영향)

  • 노재성;황의환;홍성수;이범재
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.2
    • /
    • pp.137-144
    • /
    • 1997
  • The effcct of specific g~avity cont~olled In the .range fiom O.4 to 0.7 by particle size and added amount of A1 powder in the presence or absence of water repellent agent on the physical properties of ALC was examined to evaluate frost resistance and durability. The compressive sttcngth and the tensile strength are increased and independency with water repellent agent when the specific gravity is increased in the range from 0.4 to 0.7. According as the added amount of water repellent agent was increased. frost resistance was improved and absorption ratio was decreased. ALC produced from fine Al powder has a low volume reduction by scaling and a sound apperance after freezing/thawing test and top surface freezing test.

Adsorption Properties of Cellular Light-weight Concrete using Rice Husks (왕겨숯을 이용한 경량기포콘크리트의 흡착 특성)

  • Lee, Chang-Woo;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.146-147
    • /
    • 2021
  • An increase in carbon emissions leads to the problem of global warming and is an issue to be solved in other countries. The problem of carbon dioxide has many effects not only on global warming but also on people. According to the World Health Organization (WHO), 4.3 million people have died because harmful substances generated indoors cannot be discharged to the outside and accumulate in the human body through the respiratory tract. In response to this situation, in order to reduce the generation of pollutants in the building itself, soak into lightweight bubble concrete to adsorb and purify indoor pollutants, mix charcoal, investigate the appropriate amount and physical characteristics, and check carbon dioxide This is an experiment for grasping the adsorption capacity, and the results are as follows. As the replacement rate of rice husk charcoal increased, the compressive strength tended to decrease, and the carbon dioxide reduction rate tended to increase. It is judged that the charcoal of rice husks shows a low density and the physical adsorption is smooth due to the porous structure. Since it is excellent in the basic physical properties and carbon dioxide adsorption surface of this experiment, it is judged that it has sufficient potential for use as an indoor finishing material.

  • PDF