• Title/Summary/Keyword: low-loss

Search Result 5,089, Processing Time 0.033 seconds

Analysis of Reflux Cooling in the SG U-Tubes Under Loss of RHRS During Midloop Operation with Primary System Partly Open

  • Son, Young-Seok;Kim, Won-Seok;Kim, Kyung-Doo;Chung, Young-Jong;Chang, Won-Pyo
    • Nuclear Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.112-127
    • /
    • 1998
  • The present study is to assess the applicability of the best-estimate thermal-hydraulic codes, RELAP5/MOD3.2 and CATHARE2V1.3U, to the analysis of thermal-hydraulic behavior in PWRs during midloop operation following the loss of RHRS. The codes simulate an integral test, BETHSY 6.94, which was conducted in the large scale test facility of BETHSY in France. The test represents the accident where the loss of RHRS occurs during midloop operation with the pressurizer and upper head vents open and the sight level indicator broken. Besides, the hot legs are half filled with water and the upper parts of the primary cooling system are filled with nitrogen, with a letdown line open and only one SG available. The purposes of this study are to understand the physical phenomena associated with reflux cooling in the 5G U-tubes when noncondensable gas is present under low pressure and to assess the applicability of the codes to simulate the loss of RHRS event by comparing the predictions with the test results. The results of the study may contribute to actual applications for plant safety evaluation and description of the emergency operating procedure.

  • PDF

Effects of Magnetic Powder Size on Electromagnetic Wave Absorption Characteristics in FeSiCr Flakes/Polymer Composite Sheets (FeSiCr 박편/폴리머 복합 시트의 전자파 흡수 특성에 미치는 자성분말 입도의 영향)

  • Noh, Tae-Hwan;Kim, Ju-Beom
    • Korean Journal of Metals and Materials
    • /
    • v.46 no.1
    • /
    • pp.44-51
    • /
    • 2008
  • The effects of magnetic powder size on electromagnetic wave absorption characteristics in Fe-6.5Si-0.9Cr(wt%) alloy flakes/polymer composite sheets available for quasi-microwave band have been investigated. The composite sheet including small magnetic flakes with the size less than $26{\mu}m$ exhibited high power loss in the GHz frequency range as compared with the sheets having large alloy flakes of $45{\sim}75{\mu}m$. Moreover, both the complex permeability and the loss factor increased with the decrease in size of the alloy flakes. The large power loss of the sheets containing small magnetic flakes was attributed to the high complex permeability, especially their imaginary part. The high complex permeability of the sheets composed of small flakes was considered to be due to the highly thin shape of the flakes inducing low eddy-current loss.

Fast transport with wall slippage

  • Tang, Zhipeng;Zhang, Yongbin
    • Membrane and Water Treatment
    • /
    • v.12 no.1
    • /
    • pp.37-41
    • /
    • 2021
  • This paper presents the multiscale calculation results of the very fast volume transport in micro/nano cylindrical tubes with the wall slippage. There simultaneously occurs the adsorbed layer flow and the intermediate continuum fluid flow which are respectively on different scales. The modeled fluid is water and the tube wall is somewhat hydrophobic. The calculation shows that the power loss on the tube no more than 1.0 Watt/m can generate the wall slippage even if the fluid-tube wall interfacial shear strength is 1 MPa; The power loss on the scale 104 Watt/m produces the volume flow rate through the tube more than one hundred times higher than the classical hydrodynamic theory calculation even if the fluid-tube wall interfacial shear strength is 1 MPa. When the wall slippage occurs, the volume flow rate through the tube is in direct proportion to the power loss on the tube but in inverse proportion to the fluid-tube wall interfacial shear strength. For low interfacial shear strengths such as no more than 1 kPa, the transport in the tube appears very fast with the magnitude more than 4 orders higher than the classical calculation if the power loss on the tube is on the scale 104 Watt/m.

Optimum Hydraulic Oil Viscosity Based on Slipper Model Simulation for Swashplate Axial Piston Pumps/Motors

  • Kazama, Toshiharu
    • Journal of Drive and Control
    • /
    • v.18 no.4
    • /
    • pp.84-90
    • /
    • 2021
  • Viscosity of hydraulic oils decreases due to loss reduction and efficiency increase of fluid power systems. However, low viscosity is not always appropriate due to the induction of large leakage and small lubricity. Therefore, a detailed study on the optimum viscosity of hydraulic oils is necessary. In this study, based on the thermohydrodynamic lubrication theory, numerical simulation was conducted using the slipper model of swashplate-type axial piston pumps and motors. The viscosity grades' (VG) effects of oils on power losses are mainly discussed numerically in fluid film lubrication, including changes in temperature and viscosity. The simulation results reveal that the flow rate increases and the friction torque decreases as VG decreases. The film temperature and power loss were minimised for a specific oil with a VG. The minimum conditions regarding the temperature and loss were different and closed. Under various operating conditions, the film temperature and power loss were minimised, suggesting that an optimum hydraulic oil with a specific VG could be selected for given operating conditions of pressure and speed. Otherwise, a preferable operating condition must be established to determine a specific VG oil.

Comprehensive Investigation on the Prevalence and Risk Factors of Coexistence of Age-related Loss of Skeletal Mu scle Mass and Obesity among Males in Their 40s

  • Jongseok Hwang
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.18 no.3
    • /
    • pp.1-9
    • /
    • 2023
  • PURPOSE: This study examined the prevalence and specific risk factors in males aged 40-49 years with the coexistence of age-related loss of skeletal muscle mass and obesity (CALSMO). METHODS: The current study analyzed the data obtained from a cross-sectional study involving a sample of 1,218 men who resided in the community and fell within the age range of 40 to 49 years. Multiple risk factors were examined: age, height, weight, body mass index, waist circumference, skeletal muscle mass index, smoking and drinking habits, systolic and diastolic blood pressure, fasting glucose levels, and triglyceride and cholesterol levels. All data were analyzed via complex sampling analysis. RESULTS: The coexistence of age-related loss of skeletal muscle mass and obesity in males was 2.94% (95% CI: 2.06-4.17). The clinical risk factors were low height, high weight, body mass index, waist circumference, skeletal muscle index, systolic blood pressure, diastolic blood pressure, and fast glucose (p < .05). CONCLUSION: The study identifies the prevalence and risk factors for CALSMO among adults in the community. These findings contribute to the existing literature on CALSMO and highlight potential risk factors associated with CALSMO development in males aged 40-49 years.

A Study on the Magnetic Properties of Mn-Zn ferrite added on $V_2O_5$ and $CaCo_3$ ($V_2O_5$$CaCo_3$를 첨가한 Mn-Zn Ferrite의 자기적 특성에 관한 연구)

  • 권오흥
    • Resources Recycling
    • /
    • v.11 no.5
    • /
    • pp.30-33
    • /
    • 2002
  • Recently in the progress of electronic equipment, power transformer was considered an important part. To make power transformer with miniaturization, lightening, low Power, we need a high efficiency core material. In this paper, we added $V_2$$O_{5}$ and $CaCo_3$ to Mn-Zn Ferrite to make a high efficiency, low loss core material. The compositions are MnO : ZnO : $Fe_2$$O_3$=37 : 11 : 52 mol%. They were sintered at 1250 for Three hours. Initial permeability was measured at 0.1 MHz. At 200 mT, Power loss was measured by temperature changing at 25 KHz, 50 KHz, 100 KHz. When we added $V_2$$O_{5}$ and $CaCo_3$, 0.08 wt%, 0.05 wt% respectively, we get 415 ㎾/㎥ at 200 mT, 100 KHz, $60^{\circ}C$. We can reduce eddy current loss as a main loss of high frequency by addition of a little mount of $V_2$$O_{5}$ $CaCo_3$. So we can decrease the power transformer's power loss.

Prediction of weight loss of low temperature storage tomato (Tiwai 250) by non-destructive firmness measurement (비파괴적인 경도 측정을 통한 저온저장 토마토(티와이250)의 감모율 예측)

  • Cui, Jinshi;Yoo, Areum;Yang, Myongkyoon;Cho, Seong In
    • Food Science and Preservation
    • /
    • v.24 no.2
    • /
    • pp.181-186
    • /
    • 2017
  • This study was conducted to investigate the weight loss, firmness, external color and vitamin C (VC) content of tomatoes (Lycopersicon esculentum) using non-destructive method to measure identical tomato samples during 15 days storage at low temperature and high humidity. Tomatoes were harvested at the light red stage, sorted, box packed and then stored in thermo-hygrostat ($10{\pm}1^{\circ}C$, $90{\pm}10%RH$). The quality changes in weight loss, firmness and external color were measured every 3 day interval. Weight loss was increased by $1.13{\pm}0.15%$, but it may not be considered to affect quality. Surface color of fruit was changed, especially in lightness and hue angle value. The color values were analyzed by analysis of variance (ANOVA), and the results were significant (p<0.001). Firmness of fruit declined during storage, but it did not decrease in direct proportion. On the storage of day 15, firmness was decreased to 40% of initial state. At last, all the experiment data are summarized and the relationship between firmness and weight loss is analyzed to construct a linear regression mathematical model that can predict the weight loss with the firmness value measured by non-destructive method. This research result could be useful in helping tomato exporters and suppliers to get real-time quality factor by using proposed method and regression model.

Effects of Film Packaging and Gas Composition on the Distribution and Quality of Ginseng Sprouts (새싹인삼의 필름포장과 가스조성이 품질특성에 미치는 영향)

  • Chang, Eun Ha;Lee, Ji Hyun;Choi, Ji Weon;Shin, Il Sheob;Hong, Yoon Pyo
    • Korean Journal of Medicinal Crop Science
    • /
    • v.28 no.2
    • /
    • pp.152-166
    • /
    • 2020
  • Background: Ginsenosides, which have various physiological activities, are known to be abundant in the leaves and roots of ginseng. Ginseng sprouts can be used as a fresh vegetable and roots, stems, and leaves of ginseng can be consumed. This study aimed to investigate the effect of carbon dioxide treatment and the modified atmosphere (MA) packaging method in suppressing quality deterioration during the distribution of ginseng sprouts. Methods and Results: Ginseng sprouts were packed using Styrofoam, barrier film + non gas treatment, barrier film + gas treatment, 15 ㎛ polyamide (PA) double film + non gas treatment, 15 ㎛ PA double film + gas treatment, 25 ㎛ PA film + non gas treatment, or 25 ㎛ PA film + gas treatment. Quality parameters including gas composition, relative humidity, chlorophyll SPAD (Soil Plant Analysis Development) value, firmness, and rate of quality loss in ginseng sprouts were monitored at the following temperatures: 20℃, and 10℃. Ginseng sprouts packaged with 25 ㎛ PA film showed loss in quality because of wilting owing to low relative humidity within the film. Chlorophyll and firmness did not differ between film and gas treatments. The time point at which the combined loss from softening and decay owing to fungal, and bacterial infection and wilt reached 20% was considered the limit of distribution. At 20℃, the packaging not included in the 20% distribution loss rate limit or up to 7 days was 15 ㎛ PA double film + gas treatment. At 10℃, the packaging not included in the 20% distribution loss rate limit for up to 18 days were barrier film + gas treatment and 15 ㎛ PA double film + gas treatment. Conclusions: The film packaging suitable for the distribution of ginseng sprouts was found to be the barrier film and PA film with low gas permeability and maintaining hygroscopicity at 95% relative humidity. To prevent the loss in quality of ginseng sprouts, gas treatment (8% of O2 and 18% of CO2) in the film was found to be more suitable than no gas treatment for inhibition of decay.

The Efficacy of Low Frequency Electroacupuncture Therapy for Weight Loss in Obese Korean Women (저주파 전침 위주의 한방비만치료의 체중감량 효과 및 관련 인자에 관한 연구)

  • Hwang, Deok-Sang;Lee, Yoon-Jae;Lee, Chang-Hoon;Kim, Yong-Suk;Jang, Jun-Bock;Lee, Kyung-Sub
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.22 no.2
    • /
    • pp.140-150
    • /
    • 2009
  • Purpose: We investigated the efficacy of electroacupuncture therapy in obese Korean women in order to make basic guidelines for the use of oriental medicine in treating obesity. Methods: Forty women were divided into two groups and each was treated 12 times: 1) one group was treated using electroacupuncture (EA) involving auricular acupuncture and physical treatment, without exercise (EA group, n=10), and 2) the other group was treated using electroacupuncture and exercise (EA plus exercise group, n=30). The EA was applied to subcutaneous fat tissue manually. Body weight was evaluated every visit and body composition was checked at the $1^{st}$ and $12^{th}$ visits. Statistical comparisons were made using SPSS13.0. We compared the weight loss, body mass index (BMI), and body composition before and after treatment using the pairedt-test. The correlations between weight loss and BMI and age were examined. Results: After the $12^{th}$ treatment, both groups showed significant reductions in body weight, BMI, body fat, and body fat percentage. The weight loss averaged 4.58${\pm}$3.87% in the EA group and 4.69${\pm}$3.10% in the EA plus Exercise group. The reduction in skeletal muscle was significant in the EA group, but not significant in the EA plus Exercise group. The speed of the weight loss was correlated with age using Pearson's correlation coefficient. Based on BMI, normal and obese subjects in the EA plus Exercise group had significant reductions in body weight, BMI, body fat, and body fat percentage; the obese subjects also had a significant reduction in skeletal muscle. Conclusion: Combined EA therapy may be effective for weight reduction. Age and BMI were related to weight loss using EA therapy.

Designing and Realizing the Ground Station Receiver Low Noise Amplifier of the Next-Generation Aeronautical Surveillance System (차세대 항공 감시시스템(ADS-BES) 지상국 수신기 저잡음 증폭기 설계 및 구현)

  • Cho, Ju-Yong;Yoon, Jun-Chul;Park, Chan-Sub;Park, Hyo-Dal;Kang, Suk-Youb
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.10
    • /
    • pp.2273-2280
    • /
    • 2013
  • This article introduces the next-generation air surveillance system and investigates how to design of front-end low noise amplifier of the ground station receiver. In consideration of the international standard documentation and the performance of existing products, the study conducts the link budget on the entire system so that it can be competitive in terms of receive sensitivity or reliability. To obtain a proper low noise amplifier, standards of design are decided so that such factors as gain, gain flatness, and reflective loss can be optimal. In its design, the bias circuit appropriate for the characteristics of low power, low noise, or high gain was built, and according to the results of the simulation conducted after the optimal design, its gain was 16.24dB, noise factor was 0.36dB, input-output reflective loss was -18dB and -28dB each, and frequency stability was 1.11. According to the results measured after the design, its gain was 17dB, noise factor was 0.51dB, gain flatness was 0.23dB, and input-output reflective loss was -18.28dB and -24.50dB each, so the results gained were suitable for building the overall system.