• Title/Summary/Keyword: low-loss

Search Result 5,089, Processing Time 0.032 seconds

Nitrogen and Phosphorus Runoff Loss during Summer Season in Sandy Loam Red Pepper Field as Affected by Different Surface Management Practices in Korea

  • Han, Kyung-Hwa;Ro, Hee-Myong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.49 no.6
    • /
    • pp.669-676
    • /
    • 2016
  • A field study was conducted to determine the runoff loss of N and P in small scale of red pepper field plots (10% slope), consisting of three different plots with black polyethylene vinyl mulching (mulching), ridge without mulching (ridge), and flat without ridge and mulching (flat). Composted manure and urea as a basal application were applied at rates of $20MT\;ha^{-1}$ and $93kg\;N\;ha^{-1}$, respectively. Urea at $189kg\;N\;ha^{-1}$ and fused phosphate at $67kg\;P_2O_5\;ha^{-1}$ were additionally applied on June 25 with different fertilization methods, broadcast application in flat plot and hole injection in ridge and mulching plots. Plant uptake of N and P was positively correlated with their respective concentrations in surface soil: mulching > ridge > flat plots. The runoff loss by soil erosion was higher in flat plot than ridge and mulching plot with contour line. Nitrate loss by the runoff water had no significant differences among three surface management practices, but the higher average value in ridge and mulching plots than flat plot. Especially, the flat plot had no phosphate loss during summer season. This is probably due to low labile P content in surface soil of flat plot. In the summation of soil and water loss, flat plot was higher in N and P loss than ridge and mulching plot with contour line. Nevertheless, the nitrate and phosphate loss by runoff water could be more important for non-point source management because the water could meet the river easier than eroded soil because of re-deposition around slope land.

The Effect of the Enzyme Treatment and the Plasma Pre- Treatment on Environment Friendly Fabrics (친환경 소재에 대한 플라즈마 가공과 효소가공이 감량률에 미치는 영향)

  • Kim, Ji-Hyun
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.11 no.1
    • /
    • pp.43-51
    • /
    • 2009
  • The cotton, wool, cotton/wool blended(80:20) and tencel fabrics were treated with low temperature oxygen or argon plasma, enzymes(cellulase or protease), or oxygen plasma-enzyme and examined for their weight loss and conditions for treatment for the environment friendly finishing. In the plasma treatment argon gas had better effect on the weight loss than oxygen gas did and the weight loss of all the fabrics was increased as increasing discharge power and discharge time. The weight loss of cotton, wool, cotton/wool blended(80:20) fabrics decreased in a large measure after 1 hr but that of tencel didn't decrease after 1 hr. In case of cellulose fibers oxygen gas plasma induced chemical functional groups on the surface of substrate more than argon gas plasma did so the weight loss of wool was larger than that of cotton, tencel fabrics in oxygen plasma-enzyme treatment. The weight loss of cotton and tencel fabrics decreased the initial stage because oxygen plasma pre-treatment caused cross linking as well as etching effect but argon plasma pre-treatment didn't. The plasma pre-treatment cleared the way for enzyme treatment on the whole but oxygen plasma pre-treatment bear in hand the increase of weight loss more or less because of the cross linking on the surface of cellulose fibers. The appropriate conditions for plasma treatment was 10-1Torr, 40W for 30minutes and for cellulase treatment were enzyme concentration of $3g/{\ell}$, pH 5, $60^{\circ}C$ for 1hr and for protease treatment were enzyme concentration of $4g/{\ell}$ pH 8, $60^{\circ}C$ for 1hr.

  • PDF

A Study on Protective Coordination Setting of Positive Offset Mho Loss of Field Relay (Positive Offset Mho 계자 상실 계전기 보호 협조 정정에 관한 연구)

  • Kim, Kwnag-Hyun;Park, Ji-Kyung;Kim, Jun-Hyeok;Kim, Doo-Ung;Kang, Sung-Bum;Kim, Chul-Hwan;Lyu, Young-Sik;Yang, Jeong-Jae;Ko, Yun-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.8
    • /
    • pp.1326-1333
    • /
    • 2016
  • It is important to clear the fault and prevent resulting in damage to power system. Although the frequency of generator internal fault is relatively low, it can lead to incalculable damage to power system as well as generator. Especially, loss of field on generator can cause the generator to lose synchronism for a short time if it is not removed promptly. Therefore, it is needed to conduct research on loss of field relay for detecting or clearing the loss of field. However, the setting of the relay may vary in generator operator or engineer, and the relay is not coordinated well with other elements associated with loss of field. In this paper, we address specifically the coordination of positive offset mho loss of field relay which is one of the protection schemes for loss of field. Computer simulations are performed by using ElectroMagnetic Transients Program-Restructured Version (EMTP-RV) based on actual data.

The Difference of Weight Loss as Age and Exercise in Women after Oriental Obesity Treatment in Short Term (비만 여성에서 단기간 한방프로그램의 체중감량 효과와 운동관리 및 연령과의 연관성 연구)

  • Lee, Yoon-Jae;Hwang, Deok-Sang;Cho, Jung-Hoon;Lee, Jin-Moo;Lee, Chang-Hoon;Jang, Jun-Bock;Lee, Kyung-Sub
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.22 no.3
    • /
    • pp.197-204
    • /
    • 2009
  • Purpose: Obesity is the major risk factor of the heart disease and the metabolic disease. And many obese women have dysfunction of the endocrine system. There are many reports about oriental obesity treatment program. In clinics, the electroacupuncture with exercise is believed more effective. But the difference of weight loss as exercise and women was not studied. Methods: The subjects were 75 young women who visited Kangnam Kyunghee hospital for obesity management from March 2006 to July 2008. Six treatments had performed, the weight loss checked at every treatment. 52 women treated by oriental obesity treatment with exercise, 23 women treated therapy without exercise. As the exercise and the age, the weight loss was compared. Results: The weight loss of electroacupuncture with exercise was higher than that of electroacupuncture without exercise, but was not significant. The weight loss of perimenopausal women was significantly low. Conclusion: The comparison of electroacupuncture with exercise and electroacupuncture without exercise was not significantly different. The weight loss of the older women would be less than the weight loss of the younger.

Path loss analysis of W-band using random forest (랜덤 포레스트를 이용한 W-대역의 경로손실 분석)

  • Cho, Yeongi;Kim, Kichul;Park, Juman;Choi, Jeong Won;Jo, Han-Shin
    • Journal of IKEEE
    • /
    • v.26 no.1
    • /
    • pp.89-94
    • /
    • 2022
  • The W-band (75-110GHz) is a band that can utilize at least 10 times more bandwidth than the existing 5G band. Therefore, it is one of the bands suitable for future mobile communication that requires high speed and low latency, such as virtual and augmented reality. However, since the wavelength is short, it has a high path loss and is very sensitive to the atmospheric environment. Therefore, in order to develop a W-band communication system in the future, it is necessary to analyze the characteristics of path loss according to the channel environment. In this paper, to analyze the characteristics of the W-band path loss, the random forest technique was used, and the influence of the channel parameters according to the distance section was analyzed through the path loss data according to various channel environment parameters. As a result of the simulation, the distance has the highest influence on the path loss in the short distance, and the other channel environment factor is almost ignored. However, as the distance section became longer, the influence of distance decreased while the impact of clutter and rainfall increased.

High-performance 94 GHz Single Balanced Mixer Based on 70 nm MHEMTs and DAML Technology (70 nm MHEMT와 DAML 기반의 하이브리드 링 커플러를 이용한 우수한 성능의 94 GHz 단일 평형 혼합기)

  • Kim, Sung-Chan;Lim, Byoung-Ok;Beak, Tae-Jong;Shin, Dong-Hoon;Rhee, Jin-Koo
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.857-860
    • /
    • 2005
  • We reported 94 GHz, low conversion loss, and high isolation single balanced active-gate mixer based on 70 nm gate length InGaAs/InAlAs metamorphic high electron mobility transistors (MHEMTs). This mixer showed that the conversion loss and isolation characteristics were 2.5 ${\sim}$ 2.8 dB and under -30 dB, respectively, in the range of 93.65 ${\sim}$ 94.25 GHz. The low conversion loss of the mixer is mainly attributed to the high-performance of the MHEMTs exhibiting a maximum drain current density of 607 mA/mm, a extrinsic transconductance of 1015 mS/mm, a current gain cutoff frequency ($f_t$) of 330 GHz, and a maximum oscillation frequency ($f_{max}$) of 425 GHz. High isolation characteristics are due to hybrid ring coupler which adopted dielectric-supported air-gapped microstrip line (DAML) structure using surface micromachined technology. To our knowledge, these results are the best performance demonstrated from 94 GHz single balanced mixer utilizing GaAs-based HEMTs in terms of conversion loss as well as isolation characteristics.

  • PDF

A study of the Electron Beam Irradiator for Core-loss reduction of Grain-oriented silicon Steel

  • Kim Min;Yoon Jeong-Phil;Lee Gi-Je;Cha In-Su;Cho Sung-Oh;Lee Byeong-Cheol;Jeong Young-Uk;Yoo Jae-Gwon;Lee Jong-Min
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.93-97
    • /
    • 2001
  • A new compact, low-energy electron beam irradiator has been developed. The core-loss of silicon steels can be reduced by magnetic-domain refinement method. The irradiator was developed for the application of core-loss reduction using the method. The beam energy of the irradiator can be varied from 35 to 80 keV and the maximum current is 3mA. The irradiation area is designed to be $30\times30mm2$ now and will be upgraded to $30\times150mm2$ using a scanning magnet and scanning cone. The electron beam generated from 3 mm diameter LaB6 is extracted to the air for the irradiation of the silicon steels in the air. A special irradiation port was developed for this low-energy irradiator. A havar foil with $4.08{\mu}m$ thickness were used for the window and a cold air-cooling system keeps the foil structure by removing heat at the window. The irradiator system and its operation characteristics will be discussed.

  • PDF

Boost $1\Psi$ converter of high efficiency by partial resonant switching using lossless snubber (무손실 스너버를 이용한 부분공진 스위칭에 의한 고효율 승압형 단상 컨버터)

  • 서기영;곽동걸;전중함;이현우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.315-322
    • /
    • 1998
  • Power conversion system must increase switching frequency in order to achieve small size, light weight and low noise. However, the switches of converter are subject to high switching power losses and switching stresses. As a result, the power system has a lower efficiency. In this paper, the authors propose an AC-DC boost converter of high efficiency by partial resonant switching mode. The switching devices in the proposed circuit are operated with soft switching and the control technique of those is simplified for switch to drive in constant duty cycle. The partial resonant circuit makes use of a inductor using step up and a condenser of loss-less snubber. Besides, by regenerating energy, that is charged in a loss less snubber condenser of a snubber adopted to a common circuit, toward an input source part, this circuit can get increased efficiency. as merit. The result is that the switching loss is very low, the efficiency and power factor of system is high. The proposed converter is deemed the most suitable for high power applications where the power switching devices are used.

  • PDF

Stability of Ascorbic Acid in the Catechin Solution (Catechin용액 중에서 Ascorbic acid의 안정성)

  • Kim, Sang Oak
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.12 no.3
    • /
    • pp.284-288
    • /
    • 1983
  • This experiment was carried out to investigate the stability of ascorbic acid (AsA) in the mixed solution of AsA and catechin according to the content changes of AsA and catechin under boiling, and for the respective concentration and pH. The loss of AsA was most for 10 minutes of boiling and accelerated by the mixture of catechin, but the loss was less in the high mixture rate than in the low the loss of catechin most for 10 minutes of boiling, also as the concentration of AsA becomes higher but that of cathchin lower, and as that of AsA lower but that of catechin higher, the loss of catechin becomes less moreover in the case of the low content ratio of catechin, the stability of AsA was better in order of the pH 4, pH 5, pH 6, namely as the pH increased, but in the case of the high better in order of the pH 6, pH 5, pH 4, that is as in decreased.

  • PDF

Design and fabrication of Ka-band high power and high efficiency waveguide spatial combiner (Ka 대역 고출력 고효율 도파관 공간 결합기 설계 및 제작)

  • Kim, Hyo-Chul;Cho, Heung-Rae;Lee, Ju-Heun;Lee, Deok-Jae;An, Se-Hwan;Lee, Man-Hee;Joo, Ji-Han;Kim, Hong-Rak
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.5
    • /
    • pp.19-26
    • /
    • 2021
  • This report proposes a waveguide spatial combiner with high power low loss. The proposed spatial combiner implements high power by combining from the center of each port through a waveguide. In particular, we implement low loss using TE01 mode, which has the lowest transmission track loss among modes of circular waveguide, and miniaturization is achieved by applying a new mode conversion method. IIn addition, it was confirmed that it was suitable for high output by calculating the insulation breakdown voltage of the new mode conversion structure through E-field analysis. The final 8-way waveguide spatial combiner was designed and manufactured, and the insertion loss was less than 0.4dB and the combining efficiency was 97% or more, confirming that the electrical performance was very good compared to the planar combining method.