• Title/Summary/Keyword: low-loss

Search Result 5,088, Processing Time 0.046 seconds

A Gate Drive Circuit for Low Switching Losses and Snubber Energy Recovery

  • Shimizu, Toshihisa;Wada, Keiji
    • Journal of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.259-266
    • /
    • 2009
  • In order to increase the power density of power converters, reduction of the switching losses at high-frequency switching conditions is one of the most important issues. This paper presents a new gate drive circuit that enables the reduction of switching losses in both the Power MOSFET and the IGBT. A distinctive feature of this method is that both the turn-on loss and the turn-off loss are decreased simultaneously without using a conventional ZVS circuit, such as the quasi-resonant adjunctive circuit. Experimental results of the switching loss of both the Power MOSFET and the IGBT are shown. In addition, an energy recovery circuit suitable for use in IGBTs that can be realized by modifying the proposed gate drive circuit is also proposed. The effectiveness of both the proposed circuits was confirmed experimentally by the buck-chopper circuit.

Performance Characteristics and Prediction on a Partially Admitted Single-Stage Axial-Type Micro Turbine (부분분사 축류형 마이크로터빈에서의 성능예측 및 성능특성에 관한 연구)

  • Cho, Chong-Hyun;Cho, Soo-Yong;Choi, Sang-Kyu
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.324-330
    • /
    • 2005
  • For axial-type turbines which operate at partial admission, a performance prediction model is developed. In this study, losses generated within the turbine are classified to windage loss, expansion loss and mixing loss. The developed loss model is compared with experimental results. Particularly, if a turbine operates at a very low partial admission rate, a circular-type nozzle is more efficient than a rectangular-type nozzle. For this case, a performance prediction model is developed and an experiment is conducted with the circular-type nozzle. The predicted result is compared with the measured performance, and the developed model quite well agrees with the experimental results. So the developed model could be applied to predict the performance of axial-type turbines which operate at various partial admission rates or with different nozzle shape.

  • PDF

Characteristics of Noise Attenuation with the Variation of Flow Condition and Hole Shape of Perforated Intruding Tues in Muffler (유동조건과 내부관 구명형상의 변화에 따른 소음기의 소음저감 특성)

  • Jung, Jin-Nyon;Kim, Won-Jin;Cho, Bum-Rae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.10
    • /
    • pp.87-93
    • /
    • 1999
  • To propose a useful modelling method for an actual muffler, the noise attenuation effects of muffler was investigated according to the flow condition and the hole shape of tubes. In this work, the finite element method was used to calculate the transmission loss of muffler, The noise attenuation characteristics of four different types of muffler in the hole shape of tubes were compared mutually to find a more simple equivalent model. Analytical results showed that the overall value of transmission loss increases and the peaks of transmission loss curve shift to the low frequency with mean flow for the given muffler, Also the noise attenuation characteristics of the equivalent model having the split holes is almost the same as those of the actual muffler having many circular holes.

  • PDF

Acoustic Characteristics of a .Silencer by Using Array Resonators (공명기 배열을 이용한 소음기의 음향학적 특성)

  • 김양한;서상현
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.10
    • /
    • pp.975-982
    • /
    • 2004
  • Helmholtz resonator is used to reduce noise of the narrow frequency band. It has high transmission loss at its resonance frequency. The silencer that combines many resonators could control broadband noise at low frequency. To convey this rather simple idea, serial and parallel arrangement of resonators have been tested to obtain high transmission loss characteristics in the band of which are selects. Theoretical and experimental results explain these characteristics in the absence of mean flow. The change of acoustic characteristics by the resonance frequencies and resonators arrangement are explained by using the equivalent Impedance analysis that is defined in this paper. It shows that the transmission loss has a maximum value when the separation distance between each resonator is λ/4 of its wavelength.

Pressure Loss and Heat Transfer Characteristics of the Glass Bead - Water Flow in a Vertical Tube (수직관내 유리알-물 유동의 압력손실 및 열전달 성능)

  • 김내현;김정식;이윤표
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.04a
    • /
    • pp.121-131
    • /
    • 1996
  • Recently, circulating liquid fluidized bed heat exchangers are widely used in a number of places - chemical, process, food concentration, waste water treatment facilities, etc. In a circulating heat exchanger, solid particles circulate with the liquid, thereby increase the heat transfer and reduce the fouling potential of the heat exchanger. In this study, glass beads were circulated through a vertical tube. The pressure loss and the heat transfer coefficient were measured. At low flow velocities, glass beads enhanced the heat transfer considerably. The enhancement increased as the volume fraction of the glass beads increased. It also increased as the particle diameter increased. The pressure loss showed a similar trend. From the observed particle behavior near tube wall, a possible explanation of the trend is provided.

  • PDF

Transmission Loss Analysis of the Fiber Sandwich Panels for a Tilting Train (틸팅열차용 화이버 다층재의 차음성능 해석)

  • Kim, Seock-Hyun;Paek, In-Su;Kim, Jae-Cheol
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.2191-2194
    • /
    • 2008
  • This paper investigates the sound insulation performance of the fiber sandwich panels for a tilting train. Due to the high strength and low mass, fiber sandwich panels are widely used for aircraft structures, railway vehicle structures. These fiber sandwich panels show orthotropic behavior because of the fiber's structural characteristics. This orthotropy often reduces the critical frequency and makes negative effect on the sound insulation performance. In this study, transmission loss of the fiber panels is analyzed based on the equivalent orthotropic plate model. An analysis program is developed to calculate the transmission loss of the fiber sandwich panels. Using the program, the coincidence frequency ranges and their effects on the transmission loss are investigated.

  • PDF

In-line Variable Optical Attenuator Based on the Bending of the Tapered Single Mode Fiber

  • Kim, Kwang-Taek;Kang, Ji-Hoon;HwangBo, Seung;Im, Kie-Gon
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.3
    • /
    • pp.349-353
    • /
    • 2009
  • We propose a simple in-line variable optical attenuator (VOA) based on the bending effect of tapered single mode fibers. The influence of the taper structure and the reflective index of the external medium surrounding the taper region on the bending loss of the tapered fiber have been investigated experimentally. An attenuation range exceeding 35 dB and a very low excess loss of < 0.2 dB at 1550 nm were achieved. The measured polarization dependent loss of the present VOA at the attenuation level of 10 dB, 20 dB, and 30 dB were 0.1 dB, 0.2 dB, and 0.5 dB, respectively.

Performance Characteristics and Prediction on a Partially Admitted Single-Stage Axial-Type Micro Turbine (부분분사 축류형 마이크로터빈에서의 성능예측 및 성능특성에 관한 연구)

  • Cho Chong-Hyun;Choi Sang-Kyu;Cho Soo-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.4 s.37
    • /
    • pp.13-19
    • /
    • 2006
  • For axial-type turbines which operate at partial admission, a performance prediction model is developed. In this study, losses generated within the turbine are classified to windage loss, expansion loss and mixing loss. The developed loss model is compared with experimental results. Particularly, if a turbine operates at a very low partial admission rate, a circular-type nozzle is more efficient than a rectangular-type nozzle. For this case, a performance prediction model is developed and an experiment is conducted with the circular-type nozzle. The predicted result is compared with the measured performance, and the developed model quite well agrees with the experimental results. So the developed model could be applied to predict the performance of axial-type turbines which operate at various partial admission rates or with different nozzle shape.

A High Efficiency DC-DC Boost Converter with Passive Regenerative Snubber

  • Radika, P.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.501-507
    • /
    • 2014
  • This paper describes the improvement in converter efficiency by reducing the switching loss and by recovering the snubber stored energy. A capacitive based passive regenerative snubber circuit is modeled for a dc-dc boost converter. The proposed snubber is mainly used to reduce the turn-off loss of the main switch. The energy recovery process and the turn-off loss depends on the size of the snubber capacitance; therefore, the conventional and the proposed converters are designed for high and low input voltage conditions with different sizes of the snubber capacitance. Based on the results obtained, the snubber capacitors are classified as small, normal and large snubbers. The Matlab simulation results obtained are presented.

Dielectric Properties of Eicosamethyl Eneasiloxane (Eicosamethyl Eneasiloxane의 유전특성)

  • Cho, Kyung-Soon;Kim, Jae-Hwan;Hong, Jin-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1177-1179
    • /
    • 1993
  • A study has been carried out on the characteristics of dielectric consent and the dissipation factor of Eicosamethyl Eneasiloxane as a function of frequency($30{\sim}10^5$[Hz]) and temperature(-70[$^{\circ}C$] to 65[$^{\circ}C$]). The result shows that a well-defined maxima of the absorption curves characterized by a dipole loss mechanism at a low temperature range. For temperatures in the vicinity of room temperature and higher, the loss in the range of power frequencies are predominantly of ionic nature. The increase of ionic conduction is attributed to the presence of ionizable oxidation products and their increased dissocation feature. The effect of viscosity upon the dipole loss intensity appeared to be considerably less pronounced than that upon ionic conduction loss.

  • PDF