• Title/Summary/Keyword: low-loss

Search Result 5,088, Processing Time 0.033 seconds

DEPENDENCY OF SINGLE-PHASE FAC OF CARBON AND LOW-ALLOY STEELS FOR NPP SYSTEM PIPING ON PH, ORIFICE DISTANCE AND MATERIAL

  • Moon, Jeong-Ho;Chung, Hung-Ho;Sung, Ki-Woung;Kim, Uh-Chul;Rho, Jae-Seong
    • Nuclear Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.375-384
    • /
    • 2005
  • To investigate the flow-accelerated corrosion (FAC) dependency of carbon steel (A106 Gr. B) and low-alloy steels (1Cr-1/2Mo, 21/4Cr-1Mo) on pH, orifice distance, and material, experiments were carried out. These experiments were performed using a flow velocity of 4 m/sec (partly 9 m/sec) at pH $8.0\~10.0$ in an oxygen-free aqueous solution re-circulated in an Erosion-Corrosion Test Loop at $130^{\circ}\;{\ldots}$ for 500 hours. The weight loss of the carbon steel specimens appeared to be positively dependent on the flow velocity. That of the carbon and low-alloy steel specimens also showed to be distinguishably dependent on the pH. At pH levels of $8.0\~9.5$ it decreased, but increased from 9.5 to 10.0. Utility water chemistry personnel should carefully consider this kind of pH dependency to control the water system pH to mitigate FAC of the piping system material. The weight loss of the specimens located further from the orifice in the distance range of $6.8\~27.2$ mm was shown to be greater, except for 21/4Cr-1Mo, which showed no orifice distance dependency. Low alloy steel specimens exhibited a factor of two times better resistance to FAC than that of the carbon steel. Based on this kind of FAC dependency of the carbon and low-alloy steels on the orifice distance and material, we conclude that it is necessary to alternate the composition of the secondary piping system material of NPPs, using low-alloy steels, such as 21/4Cr-1Mo, particularly when the system piping has to be replaced.

Low versus standard central venous pressure during laparoscopic liver resection: A systematic review, meta-analysis and trial sequential analysis

  • Mina Stephanos;Christopher M. B. Stewart;Ameen Mahmood;Christopher Brown;Shahin Hajibandeh;Shahab Hajibandeh;Thomas Satyadas
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.28 no.2
    • /
    • pp.115-124
    • /
    • 2024
  • To compare the outcomes of low central venous pressure (CVP) to standard CVP during laparoscopic liver resection. The study design was a systematic review following the PRISMA statement standards. The available literature was searched to identify all studies comparing low CVP with standard CVP in patients undergoing laparoscopic liver resection. The outcomes included intraoperative blood loss (primary outcome), need for blood transfusion, mean arterial pressure, operative time, Pringle time, and total complications. Random-effects modelling was applied for analyses. Type I and type II errors were assessed by trial sequential analysis (TSA). A total of 8 studies including 682 patients were included (low CVP group, 342; standard CVP group, 340). Low CVP reduced intraoperative blood loss during laparoscopic liver resection (mean difference [MD], -193.49 mL; 95% confidence interval [CI], -339.86 to -47.12; p = 0.01). However, low CVP did not have any effect on blood transfusion requirement (odds ratio [OR], 0.54; 95% CI, 0.28-1.03; p = 0.06), mean arterial pressure (MD, -1.55 mm Hg; 95% CI, -3.85-0.75; p = 0.19), Pringle time (MD, -0.99 minutes; 95% CI, -5.82-3.84; p = 0.69), operative time (MD, -16.38 minutes; 95% CI, -36.68-3.39; p = 0.11), or total complications (OR, 1.92; 95% CI, 0.97-3.80; p = 0.06). TSA suggested that the meta-analysis for the primary outcome was not subject to type I or II errors. Low CVP may reduce intraoperative blood loss during laparoscopic liver resection (moderate certainty); however, this may not translate into shorter operative time, shorter Pringle time, or less need for blood transfusion. Randomized controlled trials with larger sample sizes will provide more robust evidence.

A Study on the Estimation of River Management Flow in Urban Basin (도시유역의 하천유지용수 산정에 관한 연구)

  • 이영화
    • Journal of Environmental Science International
    • /
    • v.5 no.3
    • /
    • pp.377-385
    • /
    • 1996
  • This study aims at the estimation of a river management flow in urban basin analyzing Sinchun basin to be the tributary of Kumho river basin. The river management flow has to satisfy a low flow as natural flow and an environmental preservation flow estimated by a dilution flow to satisfy a target water quality in drought flow. Therefore for the estimation of a river management flow in Sinchun in this study, first Tank model as a basin runoff model estimates a low flow, a drought flow from a flow duration curve in Sinchun, second QUAL2E model as water quality model simulates water quality in Sinchun and estimates environmental preservation flow to satisfy a target water qua%its, BOD 8 mg/l by a dilution flow derived from Kumho river, Nakdong river and around water. And the river management flow is estimated by addition of a use flow and a loss flow to more flow between a low-flow and an environmental preservation flow.

  • PDF

Localized Eigenmodes in a Triangular Multicore Hollow Optical Fiber for Space-division Multiplexing in C+L Band

  • Hong, Seongjin;Oh, Kyunghwan
    • Current Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.226-232
    • /
    • 2018
  • We propose a triangular-multicore hollow optical fiber (TMC-HOF) design for uncoupled mode-division and space-division multiplexing. The TMC-HOF has three triangular cores, and each core has three modes: $LP_{01}$ and two split $LP_{11}$ modes. The asymmetric structure of the triangular core can split the $LP_{11}$ modes. Using the proposed structures, nine independent modes can propagate in a fiber. We use a fully vectorial finite-element method to estimate effective index, chromatic dispersion, differential group delay (DGD), and confinement loss by controlling the parameters of the TMC-HOF structure. We confirm that the proposed TMC-HOF shows flattened chromatic dispersion, low DGD, low confinement loss, low core-to-core crosstalk, and low crosstalk between adjacent modes. The proposed TMC-HOF can provide a common platform for MDM and SDM applications.

Synthesis and Characterization of Fluorinated Polyimides for Optical Waveguide Application

  • Han, Kwansoo
    • Macromolecular Research
    • /
    • v.8 no.4
    • /
    • pp.165-171
    • /
    • 2000
  • Fluorinated polyimides with high thermal stability, low optical absorption loss in the optical communication wavelengths of 1.3 and 1.55㎛, and low birefringence and water absorption have been investigated for optical waveguide applications. These polyimides were prepared from 2,2-bis(3,4-dicar-boxyphenyl) hexafluoropropane dianhydride (6FDA) with 1,4-bis-(4-amino-2-trifluoromethyl-phenoxy) tetrafluorobenzene (ATPT) , 1,4-bis-(4-amino-2-trifluoromethyl-phenoxy) benzene (ATPB) , and 1,3-bis-(4-amino-2-trifluoromethyl-phenoxy ) 4,6-dichlorobenzene (ATPD ), respectively. The polyimides obtained had glass transition temperatures that ranged from 260 to 280$\^{C}$, and low water absorption less than 0.4% and low optical loss (> 0.2 dB/cm) at 1.3 and 1.55㎛. Birefringency values of polymer films ranged from 0.0041 to 0.0066.

  • PDF

Physical Properties and Dyeing Behaviors of Cotton Fabric Treated with Low Temperature Plasma and/or Cellulase (저온플라즈마 및 효소처리한 면의 물성 및 염색성)

  • Yoon, Nam Sik;Lim, Yong Jin
    • Textile Coloration and Finishing
    • /
    • v.8 no.3
    • /
    • pp.59-65
    • /
    • 1996
  • Cotton fabrics were treated by low temperature plasma and/or cellulase, and its physical and dyeing properties were investigated. All the pretreatments of the cotton with low temperature plasma of oxygen, nitrogen and argon slowed down the rate of weight loss of cotton in cellulase solution. Plasma pretreatment did not show any strength retention effect on cotton fiber in the subsequent cellulase treatment. Pretreatment of cotton with low temperature oxygen plasma decreased the rate of dyeing in direct dye bath, while cellulase or plasma/cellulase pretreatment increased the rate. Equilibrium dye uptake of cotton was not changed greatly by the pretreatments except the normal untreated cotton showed more or less high uptake. The pretreatment of cellulase with a water-soluble carbodiimide reduced the enzymatic activity, and did not show any strength retention of cotton in enzymatic weight loss.

  • PDF

Classification of Microsatellite Alterations Detected in Endoscopic Biopsy Specimens of Gastric Cancers (단순반복염기서열의 변이 형태에 따른 위암 내시경 조직의 유전자형 분류)

  • Choi Young Deok;Choi Sang Wook;Jeon Eun Jeong;Jeong Jeong Jo;Min Ki Ouk;Lee Kang Hoon;Lee Sung;Rhyu Mun Gan
    • Journal of Gastric Cancer
    • /
    • v.4 no.2
    • /
    • pp.109-120
    • /
    • 2004
  • Purpose: Individual gastric cancers demonstrate complicated genetic alterations. The PCR-based analysis of polymorphic microsatellite sequences on cancer-related chromosomes has been used to detect chromosomal loss and microsatellite instability. For the purpose of preoperative usage, we analyzed the correspondance rate of the microsatellite genotype between endoscopic biopsy and surgical specimens. Materials and Methods: Seventy-three pairs of biopsy and surgical specimens were examined for loss of heterozygosity and microsatellite instability by using 40 microsatellite markers on eight chromosomes. Microsatellite alterations in tumor DNAs were classified into a high-risk group (baselinelevel loss of heterozygosity: 1 chromosomal loss in diffuse type and high-level loss of heterozygosity: 4 or more chromosomal losses) and a low-risk group (microsatellite instability and low-level loss of heterozygosity: 2 or 3 chromosomal losses in diffuse type or $1\∼3$ chromosomal losses in intestinal type) based on the extent of chromosomal loss and microsatellite instability. Results: The chromosomal losses of the biopsy and the surgical specimens were found to be different in 21 of the 73 cases, 19 cases of which were categorized into a genotype group of similar extent. In 100 surgical specimens, the high-risk genotype group showed a high incidence of nodal involvement (19 of 23 cases: $\leq$5 cm; 23 of 24 cases: >5 cm) irrespective of tumor size while the incidence of nodal involvement for the low-risk genotype group depended on tumor size (5 of 26 cases: $\leq$5 cm; 18 of 27 cases: >5 cm). Extraserosal invasion was more frequent in large-sized tumor in both the high-risk genotype group ($\leq$5 cm: 12 of 23 cases; >5 cm: 23 of 24 cases) and the low-risk genotype group ($\leq$5 cm: 7 of 26 cases; >5 cm: 16 of 27 cases). The preoperative prediction of tumor invasion and nodal involvement based on tumor size and genotype corresponded closely to the pathologic tumor stage (ROC area >0.7). Conclusion: An endoscopic biopsy specimen of gastric cancer can be used to make a preoperative genetic diagnosis that accurately reflect the genotype of the corresponding surgical specimen.

  • PDF

Magnetization Loss Characteristics of a Stacked Bi-2223 Conductor (적층 Bi-2223도체의 자화손실 특성)

  • Ryu, Gyeong-U;Han, Hyeong-Ju;Choe, Byeong-Ju;Na, Wan-Su;Ju, Jin-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.10
    • /
    • pp.554-559
    • /
    • 2002
  • The at loss is an important issue in the design of superconducting cables and transformers. In these devices the Bi-2222 tapes are usually placed face-to-face. In such arrangements ac loss is influenced by adjacent tapes. The effect is investigated by measuring the magnetization loss in the stacked conductor, which consists of various numbers of Bi-2223 tapes. For the single tape the magnetization loss in perpendicular field is larger than that in parallel field by about a factor 10. This agrees well with the prediction for hysteresis loss in slab and strip models. For the stacked conductor in perpendicular field the magnetization loss at low fields is greatly decreased, compared to the loss of the single tape. However the loss at high fields is nearly unaffected. This behavior is well described by the slab model.

Analysis of Cell to Module Loss Factor for Shingled PV Module

  • Chowdhury, Sanchari;Cho, Eun-Chel;Cho, Younghyun;Kim, Youngkuk;Yi, Junsin
    • New & Renewable Energy
    • /
    • v.16 no.3
    • /
    • pp.1-12
    • /
    • 2020
  • Shingled technology is the latest cell interconnection technology developed in the photovoltaic (PV) industry due to its reduced resistance loss, low-cost, and innovative electrically conductive adhesive (ECA). There are several advantages associated with shingled technology to develop cell to module (CTM) such as the module area enlargement, low processing temperature, and interconnection; these advantages further improves the energy yield capacity. This review paper provides valuable insight into CTM loss when cells are interconnected by shingled technology to form modules. The fill factor (FF) had improved, further reducing electrical power loss compared to the conventional module interconnection technology. The commercial PV module technology was mainly focused on different performance parameters; the module maximum power point (Pmpp), and module efficiency. The module was then subjected to anti-reflection (AR) coating and encapsulant material to absorb infrared (IR) and ultraviolet (UV) light, which can increase the overall efficiency of the shingled module by up to 24.4%. Module fabrication by shingled interconnection technology uses EGaIn paste; this enables further increases in output power under standard test conditions. Previous research has demonstrated that a total module output power of approximately 400 Wp may be achieved using shingled technology and CTM loss may be reduced to 0.03%, alongside the low cost of fabrication.

A Study on the Influences of Noise Induced Hearing Loss to the Blood Pressure (소음성 청력손실이 혈압에 미치는 영향에 관한 조사연구)

  • Kim, Jong-Hwa;Lee, Choong-Ryeol
    • Journal of Preventive Medicine and Public Health
    • /
    • v.20 no.2 s.22
    • /
    • pp.205-214
    • /
    • 1987
  • For the purpose of evaluating the effect of noise induced hearing loss on the blood pressure, a cross-sectional study was conducted in 481 manufacturing industrial workers in Pusan area consisted of 275 workers from noisier plant (over 90 dB(A), high exposed group) and 206 workers from less noisy plant (below 85 dB(A), low exposed group) from April to Decepmber in 1985. The summarized results were as follows; 1) The degree of hearing loss according to the audible frequency was most notable in 4,000 Hz. 2) The prevalence of hypertension was 14.8% in total examined subjects. And also in 40 dB(A) hearing lost workers, there was no significant difference between high exposed group as 15.5% and low exposed group as 15.8%. 3) In 3 models analyzed by multiple regression technique to obtain the complexed extents of risk factors related to the diastolic blood pressure, especially model III which contain age, body mass index, smoking, alcohol and family history of hypertension, duration of work, noise exposure level and degree of hearing loss in high exposed group was most remarkable compared to the others. 4) The most potential predictor related to the diastolic pressure in high exposed group was the degree of hearing loss. And the next were body mass index, familial history of hypertension and age in order. But in the case of low exposed group, the potential predictors were body mass index, age and familial history of hypertension.