• Title/Summary/Keyword: low-VOC

Search Result 142, Processing Time 0.029 seconds

Combustion of Low Concentration VOC on a Turbulent Partially Premixed Flame (난류 부분예혼합 화염을 이용한 난연성 유증기 처리에 관한 연구)

  • Ahn, Taekook;Park, Sunho;Nam, Younwoo;Lee, Wonnam
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.207-210
    • /
    • 2014
  • The potential of combustion treatment of low concentration VOC on a turbulent partially premixed flame has been studied experimentally. The significant decrease in hydrocarbon concentration from the low concentration VOC was observed with a turbulent partially premixed flame. The VOC/inert gas mixture whose fuel concentration is beyond the flammability limit could be treated in this method.

  • PDF

Trends and Control Technologies of Volatile Organic Compound (국내의 휘발성유기화합물(VOC) 현황 및 관리기술)

  • Kim, Jo-Chun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.743-757
    • /
    • 2006
  • Volatile organic compound (VOC) has been well-known to Korea since the end of 1990's however, it has not been well documented until now. In this study, present ambient VOC levels, VOC emission sources, and VOC control technologies were reviewed and discussed. In addition, VOC management strategies to cut down ozone concentrations were suggested based on the present VOC database. For anthropogenic VOC reduction, VOC emitted from painting processes and automobiles should be controlled in the first place in large cities such as Seoul, Daegu, and Incheon. For natural VOC management, low emission trees need to be planted in those cities. It is also very significant to keep updating present and future VOC emission inventories for efficient VOC control strategies. As a conclusion, more systematic VOC control road-map based on BACT (best available control technology) needs to be made up. and more economical and efficient VOC control techniques have to be developed under strong national support in order to lower toxic VOC and photochemical oxidant levels.

Characteristics of a Plasma-Dump Combustor for VOC Destruction (VOC 분해 플라즈마-덤프 연소기 특성)

  • Kim, Eun Hyuk;Chun, Young Nam
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.8
    • /
    • pp.492-497
    • /
    • 2015
  • VOCs (Volatile Organic Compounds) are generally generated in the painting process, or at the company and laundry where use organic solvents. The VOCs consist of various hydrocarbons and has low calorific value due to its dilution with atmospheric air. Therefore, the VOCs are difficult to burn by a conventional fuel combustor. In this study, a novel plasma dump combustor was proposed for the treatment of low calorific VOC gases. This combustor was designed a combination of the characteristics in a plasma burner, a dump combustor and a 3D matrix burner. The combustor has good structure for maintaining enough residence time and reaction temperature for stable flame formation and VOC destruction. For investigating the performance characteristics of the plasma dump combustor, an experiment was achieved for VOC feed rate, VOC injector position, etc. Toluene was used as a surrogate of VOC. The novel combustor gave better performance than a conventional combustor, showing that VOC destruction rate and energy efficiency were 89.64% and 12.27 kg/kWh respectively, at feeding rate of 450 L/min of VOC of 3,000 ppm of toluene concentration.

Adhesion Properties of Low VOC-type Primer Containing Acrylic Modified Tackifier Resin (Acrylic Modified Hydrocarbone Resin을 포함하는 저독성 프라이머의 제조 및 특성)

  • Jeong, Boo-Young;Cheon, Jung-Mi;Oh, Sang-Taek;Chun, Jea-Hwan;Jo, Nam-Ju
    • Journal of Adhesion and Interface
    • /
    • v.12 no.1
    • /
    • pp.11-15
    • /
    • 2011
  • In this study we synthesized low VOC-solvent soluble thermo plastic polyurethane, The effect of chain extender and NCO/OH ratio for properties of thermoplastic polyurethane was investigated. Also, we prepared low VOC-type primer by TPU and acrylic modified tackifier resin. When NCO/OH ratio was 2 or more, TPU was insoluble in low VOC solvent. And peel strength was higher value using polar type tackifier than non-ploar type tackifier.

A Numerical Analysis of the Abatement of VOC with Different Photocatalytic Honeycomb Filters (광촉매 필터형상에 따른 휘발성 유기화합물의 제거에 관한 수치해석적 연구)

  • 류무성;김창녕
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.1-7
    • /
    • 2004
  • This study has been numerically conducted to investigate the removal efficiency of Volatile Organic Compound (VOC) for different photocatalytic honeycomb filters. Recently, the photocatalysis is being applied to air-cleaner, air-conditioner and vacuum-cleaner with the capability of air-purification, sterilization and antibiosis. However, photocatalysis is less efficient than other methods for removing VOC except in the case of low concentration. So far most of studies have focused on an improvement of the photocatalytic materials, but this study have placed emphasis on the improvements of shape of photocatalytic honeycomb filter. UV irradiation, concentration profile and pressure drop have been investigated for different cross sections of filters and for different filter lengths. Light intensity is dropped sharply with increasing distance from the UV-lamp, and becomes very low in the middle of the filters. Since photocatalytic reaction rate is a function of light intensity, VOC concentration gradient might be small in the middle of long filters. Thus, most of reaction have risen within only three times of dimensionless axial distance. These results can be used effectively for the design of advanced photocatalytic honeycomb filters.

Selection on Representative Compound According to the Characteristics of the Change of VOC Concentration Indoor from the Newly Built House in Japan (일본 신축주택의 실내 VOC의 실태와 농도추이 특성에 의한 유형별 대표물질선정)

  • Yoo, Bok-Hee;Tanaka, Tatsuaki;Yoon, Chung-Sook
    • KIEAE Journal
    • /
    • v.1 no.1
    • /
    • pp.35-43
    • /
    • 2001
  • The VOC, which were detected from the newly built house, exist as a certain number of types according to the characteristics of the change of VOC concentration indoors. In this paper, we aim to divide the VOC into types so that those with similar characteristics of the transition of their concentration are in the same group and select the representative compound according to each classified type, and to verify these processes statistically in order to verify and propose new method creating the representing index of the VOC concentration in indoor which is used in evaluation of the degree of air pollution. As a result, the characteristic of the change of VOC concentration in the indoor can be divided into three types. Type1; the group in which the concentration is relatively high right after the completion of the house, and then decreases rapidly. Type2; the group in which the concentration is relatively low right after the completion of the house, and then although it shows the tendency of increasing and decreasing repeatedly, it decreases overall. Type3 is the group, which show only one peak at a certain time during the measuring period. As the method like this was verified to have the statistical significance, the Ethylbenzene was selected as the representative compound of type1, and Styrene was selected as that of type2. Moreover, if considering transition of the VOC from the point of similarity, the research method of making the classification and the selection of the representative compound in this study are said to be significant method.

  • PDF

Low-Temperature Thermal Decomposition of Industrial N-Hexane and Benzene Vapors (산업 발생 노르말헥산과 벤젠 증기의 저온 분해)

  • Jo Wan-Kuen;Lee Joon-Yeob;Kang Jung-Hwan;Shin Seung-Ho;Kwon Ki-Dong;Kim Mo-Geun
    • Journal of Environmental Science International
    • /
    • v.15 no.7
    • /
    • pp.635-642
    • /
    • 2006
  • Present study evaluated the low-temperature destruction of n-hexane and benzene using mesh-type transition-metal platinum(Pt)/stainless steel(SS) catalyst. The parameters tested for the evaluation of catalytic destruction efficiencies of the two volatile organic compounds(VOC) included input concentration, reaction time, reaction temperature, and surface area of catalyst. It was found that the input concentration affected the destruction efficiencies of n-hexane and benzene, but that this input-concentration effect depended upon VOC type. The destruction efficiencies increased as the reaction time increased, but they were similar between two reaction times for benzene(50 and 60 sec), thereby suggesting that high temperatures are not always proper for thermal destruction of VOCs, when considering the destruction efficiency and operation costs of thermal catalytic system together. Similar to the effects of the input concentration on destruction efficiency of VOCs, the reaction temperature influenced the destruction efficiencies of n-hexane and benzene, but this temperature effect depended upon VOC type. As expected, the destruction efficiencies of n-hexane increased as the surface area of catalyst, but for benzene, the increase rate was not significant, thereby suggesting that similar to the effects of the re- action temperature on destruction efficiency of VOCs, high catalyst surface areas are not always proper for economical thermal destruction of VOCs. Depending upon the inlet concentrations and reaction temperatures, almost 100% of both n-hexane and benzene could be destructed, The current results also suggested that when applying the mesh type transition Metal Pt/SS catalyst for the better catalytic pyrolysis of VOC, VOC type should be considered, along with reaction temperature, surface area of catalyst, reaction time and input concentration.

Characteristics of Ozone Concentration Weekend Effect in Busan Area (부산지역 오존농도의 주말 효과 특성)

  • Jeon, Byung-Il
    • Journal of Environmental Science International
    • /
    • v.23 no.5
    • /
    • pp.861-871
    • /
    • 2014
  • This study analyzes the characteristics of ozone weekend effect(OWE) in Busan. $O_3$ concentration on Sunday was over 10% higher than that on weekdays in all areas except for Kwangbokdong, Taejongdae, and Joadong. Such a difference was higher in the industrial area than in the residential area. $O_3$ generation was facilitated by the decrease in $NO_X$ emission on Sunday in VOC-limited regime where the VOC/$NO_X$ ratio is low. Low NO concentration in the Sunday morning decreased inhibition of $O_3$. NO-$O_3$ crossover time on Sunday was shorter than that on weekdays which in turn extended the accumulated duration of $O_3$. Future studies can include whether the entire Busan is VOCS-limited or the coastal area is VOCS-limited while the inland area is $NO_X$-limited.

A Study on Concentration Change of Volatile Organic Compounds; VOCs by using Mock-up Test (실물실험을 통한 개별 VOC의 농도변화에 관한 연구)

  • Kim Chang-Nam;Lee Yun-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.487-495
    • /
    • 2005
  • Recently, due to the airtightness of buildings or the misuse of building materials, we have been witness SHS (Sick House Syndrome) which can have bad influences on the resident in an existing apartment house as well as newly constructed apartment house start to attract public attention. As a result of this situation, we went to restrict the TVOC (Total Volatile Organic Compound) and formaldehyde. But these guidelines concentrated on only TVOC although TVOC are consist of many individual VOC. Therefore, in this study, we will look about concentration change of VOCs (Volatile Organic Compounds) by using Mock-up test. As result of test, the concentration of four individual VOC (Benzene, Toluene, Ethylbenzene, Styrene) showed quitely low level after 7 days. On the other hand the concentration of Xylene and formaldehyde showed low level after 14 days.

Machine Vision Platform for High-Precision Detection of Disease VOC Biomarkers Using Colorimetric MOF-Based Gas Sensor Array (비색 MOF 가스센서 어레이 기반 고정밀 질환 VOCs 바이오마커 검출을 위한 머신비전 플랫폼)

  • Junyeong Lee;Seungyun Oh;Dongmin Kim;Young Wung Kim;Jungseok Heo;Dae-Sik Lee
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.2
    • /
    • pp.112-116
    • /
    • 2024
  • Gas-sensor technology for volatile organic compounds (VOC) biomarker detection offers significant advantages for noninvasive diagnostics, including rapid response time and low operational costs, exhibiting promising potential for disease diagnosis. Colorimetric gas sensors, which enable intuitive analysis of gas concentrations through changes in color, present additional benefits for the development of personal diagnostic kits. However, the traditional method of visually monitoring these sensors can limit quantitative analysis and consistency in detection threshold evaluation, potentially affecting diagnostic accuracy. To address this, we developed a machine vision platform based on metal-organic framework (MOF) for colorimetric gas sensor arrays, designed to accurately detect disease-related VOC biomarkers. This platform integrates a CMOS camera module, gas chamber, and colorimetric MOF sensor jig to quantitatively assess color changes. A specialized machine vision algorithm accurately identifies the color-change Region of Interest (ROI) from the captured images and monitors the color trends. Performance evaluation was conducted through experiments using a platform with four types of low-concentration standard gases. A limit-of-detection (LoD) at 100 ppb level was observed. This approach significantly enhances the potential for non-invasive and accurate disease diagnosis by detecting low-concentration VOC biomarkers and offers a novel diagnostic tool.