• 제목/요약/키워드: low wind speed

검색결과 611건 처리시간 0.022초

Unsteady galloping of sharp-edged bluff bodies: experimental observations on the effect of the wind angle of attack

  • Chen, Cong;Dai, Bingyu;Wieczorek, Niccolo;Unglaub, Julian;Thiele, Klaus
    • Wind and Structures
    • /
    • 제35권4호
    • /
    • pp.255-268
    • /
    • 2022
  • Light-weight or low-damped structures may encounter the unsteady galloping instability that occurs at low reduced wind speeds, where the classical quasi-steady assumption is invalid. Although this unsteady phenomenon has been widely studied for rectangular cross sections with one side perpendicular to the incidence flow, the effect of the mean wind angle of attack has not been paid enough attention yet. With four sectional models of different side ratios and geometric shapes, the presented research focuses on the effect of the wind angle of attack on unsteady galloping instability. In static tests, comparatively strong vortex shedding force was noticed in the middle of the range of flow incidence where the lift coefficient shows a negative slope. In aeroelastic tests with a low Scruton number, the typical unsteady galloping, which is due to an interaction with vortex-induced vibration and results in unrestricted oscillation initiating at the Kármán vortex resonance wind speed, was observed for the wind angles of attack that characterize relatively strong vortex shedding force. In contrast, for the wind angles of attack with relatively weak shedding force, an "atypical" unsteady galloping was found to occur at a reduced wind speed clearly higher than the Kármán-vortex resonance one. These observations are valid for all four wind tunnel models. One of the wind tunnel models (with a bridge deck cross section) was also tested in a turbulent flow with an intensity about 9%, showing only the atypical unsteady galloping. However, the wind angle of attack with the comparatively strong vortex shedding force remains the most unfavorable one with respect to the instability threshold in low Scruton number conditions.

저속풍동 시험부 속도교정에 관한 실험적 연구 (An Experimental Study of Test Section Velocity Calibration for Low-Speed Wind Tunnel)

  • 오세윤;이종건;김성철;김상호;안승기
    • 한국항공우주학회지
    • /
    • 제40권3호
    • /
    • pp.230-236
    • /
    • 2012
  • 본 연구의 목적은 풍동 시험부의 속도산출에 필요한 속도측정시스템용 교정계수를 실험적으로 결정하는데 있었다. 교정실험은 국방과학연구소 저속풍동에서 표준 피토관을 이용하여 수행되었으며 이때의 교정속도 영역은 약 10~100 m/s이었다. 풍동교정실험결과의 유효성 평가를 위해 기존의 교정계수 측정결과와의 비교검토를 수행하였으며, 기존 교정 결과들과 잘 부합됨을 확인하였다.

Development of Algorithm for the Decision of Ship's Strong Wind Warning Levels

  • Shouhu, Hu;Moon, Serng-Bae
    • 한국항해항만학회지
    • /
    • 제42권5호
    • /
    • pp.317-322
    • /
    • 2018
  • Marine weather information provided for vessels is mainly offered by radio devices such as NAVTEX, Weather Fax., and others. However, the information is too general for large areas, and lacks more detail. So, many seafarers are disinclined to use the information to initiate proper readiness of vessels' safety, avoiding marine accidents such as grounding, hull and cargo damage, but cannot develop an optimal and economical navigation plan, considering the inadequate level of low precision weather information. The purpose of this paper is to develop a strong wind warning system, based on the digital anemometer installed on the bridge. This study analyzed the data on 10-minutes average wind speed, when the vessel's grounding accidents happened in Korean ports. Results reveal that the vessel's strong wind warning algorithm, can estimate the growing of wind speed two-three hours in advance.

경계층 이론에 의한 스포일러 선루프의 윈드 디플렉터 설계 (Wind Deflector Design of Spoiler Sunroof by Boundary Theory)

  • 조현덕
    • 한국기계가공학회지
    • /
    • 제5권3호
    • /
    • pp.17-22
    • /
    • 2006
  • Sunroof is getting widely used in automobiles since it maintains, compare to window, better air circulation as well as less noise while driving in high speed. In this study, we consider an electronic control type spoiler sunroof which slides backward after tilting a rear part of a glass. Installing a wind deflector on the sunroof reduces noise much more effectively. The height of the wind deflector is designed using a boundary theory related to incompressible air layer. The developed wind deflector is investigated experimentally by measuring a wind noise. When the height of the wind deflector is designed by a fixed type, the sunroof maintains a very quiet interior noise over a certain driving speed, nevertheless it produces relatively loud noise in low driving speed.

  • PDF

Design and Performance Analysis of Coreless Axial-Flux Permanent-Magnet Generator for Small Wind Turbines

  • Chung, Dae-Won;You, Yong-Min
    • Journal of Magnetics
    • /
    • 제19권3호
    • /
    • pp.273-281
    • /
    • 2014
  • This paper presents an innovative design for a low-speed, direct-drive, axial-flux permanent-magnet (AFPM) generator with a coreless stator and rotor that is intended for application to small wind turbine power generation systems. The performance of the generator is evaluated and optimized by means of comprehensive 3D electromagnetic finite element analysis. The main focus of this study is to improve the power output and efficiency of wind power generation by investigating the electromagnetic and structural features of a coreless AFPM generator. The design is validated by comparing the performance achieved with a prototype. The results of our comparison demonstrate that the proposed generator has a number of advantages such as a simpler structure, higher efficiency over a wide range of operating speeds, higher energy yield, lighter weight and better power utilization than conventional machines. It would be possible to manufacture low-cost, axial-flux permanent-magnet generators by further developing the proposed design.

Near-ground wind and its characterization for engineering applications

  • Crandell, Jay H.;Farkas, William;Lyons, James M.;Freeborne, William
    • Wind and Structures
    • /
    • 제3권3호
    • /
    • pp.143-158
    • /
    • 2000
  • This report presents the findings of a one-year monitoring effort to empirically characterize and evaluate the nature of near-ground winds for structural engineering purposes. The current wind engineering practice in the United States does not explicitly consider certain important near-ground wind characteristics in typical rough terrain conditions and the possible effect on efficient design of low-rise structures, such as homes and other light-frame buildings that comprise most of the building population. Therefore, near ground wind data was collected for the purpose of comparing actual near-ground wind characteristics to the current U.S. wind engineering practice. The study provides data depicting variability of wind speeds, wind velocity profiles for a major thunderstorm event and a northeaster, and the influence of thunderstorms on annual extreme wind speeds at various heights above ground in a typical rough environment. Data showing the decrease in the power law exponent with increasing wind speed is also presented. It is demonstrated that near-ground wind speeds (i.e., less than 10 m above ground) are likely to be over-estimated in the current design practice by as much as 20 percent which may result in wind load over-estimate of about 50% for low-rise buildings in typical rough terrain. The importance of thunderstorm wind profiles on determination of design wind speeds and building loads (particularly for buildings substantially taller than 10 m) is also discussed. Recommendations are given for possible improvements to the current design practice in the United States with respect to low-rise buildings in rough terrain and for the need to study the impact of thunderstorm gust profile shapes on extreme value wind speed estimates and building loads.

소형 수직축 풍력발전기 풍동실험시 폐쇄율의 영향 (Effect of Blockage Ratio on Wind Tunnel Testing of Small Vertical-Axis Wind Turbines)

  • 정회갑;이승호;권순덕
    • 한국태양에너지학회 논문집
    • /
    • 제34권3호
    • /
    • pp.98-106
    • /
    • 2014
  • The effect of blockage ratio on wind tunnel testing of small vertical-axis wind turbine has been investigated in this study. Height and rotor diameter of the three blades Darrieus vertical axis wind turbine used in present test were 0.4m and 0.35m respectively. We measured the wind speeds and power coefficient at three different wind tunnels where blockage ratio were 3.5%, 13.4% and 24.7% respectively. The test results show that the measured powers have been strongly influenced by blockage ratio, generally increased as the blockage ratio increases. The maximum power at higher blockage ratio has been obtained at relatively high tip speed ratio compared with that at low blockage ratio. The measured power coefficients under high blockage ratio can be improved from proper correction using the simple correction equation based on blockage factor. In present study, the correction error for power coefficient can be less than 5%, however correction effectiveness reveals relatively poor at high blockage ratio and low wind speed.

Comparison of MPPT Based on Fuzzy Logic Controls for PMSG

  • Putri, Adinda Ihsani;Choi, Jaeho
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.285-286
    • /
    • 2011
  • Maximum Power Point Tracker (MPPT) is the big issue in generating power based on Wind Energy Conversion System. In case of unknown turbine characteristic, it is useful to implement MPPT based on fuzzy logic control. This kind of control is able to find the value of duty cycle to meet maximum power point at particular wind speed. There are many methods to develop MPPT based fuzzy logic controls. In this paper, two of the methods are compared both at low and high fluctuating wind speed.

  • PDF

기상인자가 대기오염에 미치는 영향 (The Influence of Climatic Conditions on Air Pollution in Seoul)

  • 어수미;김광진;이규남
    • 한국환경보건학회지
    • /
    • 제23권4호
    • /
    • pp.104-114
    • /
    • 1997
  • This study was carried out to research the influence of climatic conditions including wind direction, wind speed on air pollution in Seoul. The data were obtained from the 4 sites of air pollution monitoring stations in Seoul from '95 to '96, and analyzed statistically by SAS program. The results were as follows 1. The prevailing wind directions by season in each site were as follows Nangajwa-dong were showed SE in spring, fall, winter and WNW in summer. Ssangmun-dong were showed NW in spring, fall, winter and NNE in summer. Kuro-dong were showed SW in spring, summer, ENE in fall and NW in winter. Bangi-dong were showed WNW in four seeasons. 2. The concentrations of 5 kinds(SO$_2$, Dust, NO$_2$, CO, THC) of air pollutants were relatively low in west wind. In case of O$_3$ was opposite. 3. The concentrations of 5 kinds of air pollutants were increase with decreasing wind speeds. 4. The washing effects of air pollution by rain were significant. The concentrations of 5 kinds of air pollutants were high when the humidity were 61-80%, and low as it were 0-20%. In case of O$_3$ was opposite. 5. All of air pollutants concentrations but O$_3$ were high when the UV intensity level and temperature within the range of above zero were low level.

  • PDF

파워 조절 방법에 따른 풍력 터번 발전기의 방사 소음 특성 (Characteristics of Noise Emission from Wind Turbine Generator According to Methods of Power Regulation)

  • 정성수;정완섭;신수현;전세종;최용문;정철웅
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.941-945
    • /
    • 2006
  • In the development of electricity generating wind turbines for wind farm application, only two types have survived as the methods of power regulation; stall regulation and fun span pitch control. The sound measurement procedures of IEC 61400-11 are applied to field test and evaluation of noise emission from each of 1.5 MW and 660 kW wind turbine generators (WTG) utilizing the stall regulation and the pitch control for the power regulation, respectively. Apparent sound power level, wind speed dependence and third-octave band levels are evaluated for both of WTGs. It is found that while 1.5 MW WTG using the stall control is found to emit lower sound power than 660 kW one using the pitch control at low wind speed (below 8 m/s), sound power from the former becomes greater than that of the latter in the higher wind speed. Equivalent continuous sound pressure levels (ECSPL) of the stall control type of WTG vary more widely with wind speed than those of the pitch control type of WTG These characteristics are believed to be strongly dependent on the basic difference of the airflow around the blade between the stall regulation and the pitch control types of WTG. These characteristics according to the methods of power regulation lead to the very different noise emission characteristics of WTG depending on the seasons because the average wind speed in summer is lower than the critical velocity over which the airflow on the suction side of blade in the stall types of WT are separated. These results propose that, in view of environmental noise regulation, the developer of wind farm should give enough considerations to the choice of power regulation of their WTG based on the weather conditions of potential wind farm locations.

  • PDF