• Title/Summary/Keyword: low wind speed

Search Result 617, Processing Time 0.025 seconds

The Effect of Folding Wing on Aerodynamics and Power Consumption of a Flapping Wing

  • Lee, Seunghee;Han, Cheolheui
    • International Journal of Aerospace System Engineering
    • /
    • v.3 no.2
    • /
    • pp.26-30
    • /
    • 2016
  • Experimental study on the unsteady aerodynamics analysis and power consumption of a folding wing is accomplished using a wind tunnel testing. A folding wing model is fabricated and actuated using servo motors. The flapping wing consists of an inboard main wing and an outboard folding wing. The aerodynamic forces and consumed powers of the flapping wing are measured by changing the flapping and folding wings inside a low-speed wind tunnel. In order to calculate the aerodynamic forces, the measured forces are modified using static test data. It was found that the effect of the folding wing on the flapping wing's total lift is small but the effect of the folding wing on the total thrust is larger than the main wing. The folding motion requires the extra use of the servo motor. Thus, the amount of the energy consumption increases when both the wings are actuated together. As the flight speed increases, the power consumption of the folding wing decreases which results in energy saving.

Serviceability evaluation methods for high-rise structures considering wind direction

  • Ryu, Hye-Jin;Shin, Dong-Hyeon;Ha, Young-Cheol
    • Wind and Structures
    • /
    • v.30 no.3
    • /
    • pp.275-288
    • /
    • 2020
  • High-rise buildings are very slender and flexible. Their low stiffness values make them vulnerable to horizontal loads, such as those associated with wind or earthquakes. For high-rise buildings, the threat to serviceability caused by wind-induced vibration is an important problem. To estimate the serviceability under wind action, the response acceleration of a building at the roof height is used. The response acceleration is estimated by the same wind speed at all wind directions. In general, the effect of wind direction is not considered. Therefore, the response accelerations obtained are conservative. If buildings have typical plans and strong winds blow from relatively constant wind directions, it is necessary to account for the wind direction to estimate the response accelerations. This paper presents three methods of evaluating the response accelerations while considering the effects of wind direction. These three serviceability evaluation methods were estimated by combining the wind directional frequency data obtained from a weather station with the results of a response analysis using wind tunnel tests. Finally, the decrease in the efficiencies of the response acceleration for each serviceability evaluation method was investigated by comparing the response acceleration for the three methods accounting for wind direction with the response acceleration in which wind direction was not considered.

Two case studies on structural analysis of transmission towers under downburst

  • Yang, FengLi;Zhang, HongJie
    • Wind and Structures
    • /
    • v.22 no.6
    • /
    • pp.685-701
    • /
    • 2016
  • Downbursts are of great harm to transmission lines and many towers can even be destroyed. The downburst wind field model by Chen and Letchford was applied, and the wind loads of two typical transmission towers in inland areas and littoral areas were calculated separately. Spatial finite element models of the transmission towers were established by elastic beam and link elements. The wind loads as well as the dead loads of conductors and insulators were simplified and applied on the suspension points by concentrated form. Structural analysis on two typical transmission towers under normal wind and downburst was completed. The bearing characteristics and the failure modes of the transmission towers under downburst were determined. The failure state of tower members can be judged by the calculated stress ratios. It shows that stress states of the tower members were mainly controlled by 45 degree wind load. For the inland areas with low deign wind velocity, though the structural height is not in the highest wind velocity zone of downburst, the wind load under downburst is much higher than that under normal wind. The main members above the transverse separator of the legs will be firstly destroyed. For the littoral areas with high deign wind velocity, the wind load under downburst is lower than under normal wind. Transmission towers are not controlled by the wind loads from downbursts in design process.

Characteristics of Ozone Concentrations around an Urban Valley based on the Intensive Air Quality Measurement during Spring and Summer of 2006 (2006년 봄, 여름철 대기오염물질 집중측정을 통한 도시 계곡지역의 오존농도 특성 분석)

  • Song, Sang-Keun;Kim, Yoo-Keun;Kang, Jae-Eun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.4
    • /
    • pp.289-303
    • /
    • 2009
  • The chemical and meteorological effects on the concentration variations of ozone ($O_3$) were evaluated based on the intensive air quality measurement (5 pollutants and aromatic volatile organic compounds (AVOCs)) in and out-side an urban valley during spring and summer of 2006. The 5 pollutants measured in the study area include $O_3$, $NO_2$, NO, $PM_{10}$, and CO; the AVOCs include benzene (BEN), toluene (TOL), ethylbenzene (EB), m,p-xylene (MPX), and o-xylene (OX). For the purpose of this study, study areas were classified into two categories: valley area (VA) with a semi-closed topography covering a number of industrial complex, public building, and mountains and non-valley area (NVA) surrounding the suburban and residential areas. In general, the mean concentration levels of most pollutants (except for $PM_{10}$) in the VA were higher than those in the NVA. It was found that the average $O_3$ increase in the VA during spring might result from the combined effects such as the photochemical production from diverse anthropogenic sources and the $O_3$ accumulation due to geographical features (e.g., the semi-closed topography) and wind conditions (e.g., a low wind speed). In addition, the nocturnal $O_3$ increase in the VA during spring was primarily caused by local wind conditions (e.g., mountain and valley winds) with the low wind speed (approximately $1{\sim}2\;m\;s^{-1}$). On the other hand, the $O_3$ difference between the two areas during summer might be because of the photo-chemical production with the $O_3$ precursors (especially the AVOCs) rather than the contribution of wind conditions.

Prediction of the Aerodynamic Noise Generated by Pantograph on High Speed Trains (고속철도 판토그래프의 공력소음 기여도 연구)

  • Han, Jae Hyun;Kim, Tae Min;Kim, Jeung Tae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.425-431
    • /
    • 2013
  • Nowadays, high speed train has settled down as a fast and convenient environment-friendly transportation and it's need is gradually increasing. However increased train speed leads to increased aerodynamic noise, which causes critically affects comfortability of passengers. Especially, the pantograph of high speed train is protruded out of train body, which is the main factor for increased aerodynamic noise. Since aerodynamic noise caused pantograph should be measured in high speed, it is difficult to measure it and to analysis aerodynamic noise characteristics due to the various types of pantograph. In this research, aerodynamic noise of pantograph is predicted by CFD (Computational Fluid Dynamic) and FW-H (Ffowcs Williams-Hawkings) equation. Also, Wind tunnel test results and numerical simulation results were compared. As a result, Simulation results predicting sound pressure level is very similar with wind tunnel test result. To analyze contribution of the pantograph to the noise of high-speed train, simulation results compared with measurement results of exterior noise. The simulation reuslts found that pantograph is a dominant noise source of high-speed trains's exterior noise in low frequency section. This dominant noise was come out from vortex shedding of the panhead in the pantograph. This research will be utilized for reduce sound pressure level of pantograph.

  • PDF

Wind Tunnel Test for the Inflation Characteristics of the Korean Low Cost Low Altitude Aerial Delivery System (한국형 저비용 저고도 공중보급 체계용 낙하산 전개 특성 풍동시험)

  • Kim, Seung Pil;Jung, Insik;Kwon, Kybeom;Choi, Younseok;Chung, Hyoungseog
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.345-351
    • /
    • 2017
  • A wind tunnel test for the scaled parachute models was performed to verify aerodynamic characteristics for practical usage of Korean low cost low altitude aerial delivery system. The cruciform shaped cargo parachute models for heavy and light weight were ejected into wind tunnel test section; and the drag forces acting on the models in steady condition were measured in accordance with velocity. Also, the maximum opening forces during inflation were obtained and captured by a high speed camera to analyze the inflation characteristics and evaluate the design of the low cost aerial delivery system. The results showed a reliable stability and met the design requirement of delivery operation system for R.O.K Air Force.

The Spatial and temporal distributions of NET(Net Effective Temperature) with a Function of Temperature, Humidity and Wind Speed in Korea (한반도의 날씨 스트레스 지수 NET(Net Effective Temperature) 분포의 특성)

  • 허인혜;최영은;권원태
    • Journal of the Korean Geographical Society
    • /
    • v.39 no.1
    • /
    • pp.13-26
    • /
    • 2004
  • This paper examined the possibility of NET application for a relative weather stress index in Korea. The characteristic of NET distribution used temperature, relative humidity, wind speed which forecasting at Korean Meteorological Administration were analyzed. Regional critical values of daily maximum NET of stress index for summer resembled the distribution of daily maximum temperature because were not impacted wind and humidity but temperature. Regional critical values of daily minimum NET of stress index for winter distributed variously compared with summer. The highland region and the northern region of Seoul were impacted of low temperature and coastal region which strong wind. The occurrences of stressful days did not vary in summer, but obviously increased in winter after mid-1990s.

Estimation of Lateral Dispersion Parameter using Observed Wind Direction Fluctuation in Chunchon (풍향변동량 측정에 의한 춘천지역의 연기 수평확산폭 산출)

  • 이종범;김정식;김용국;조창래
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.2
    • /
    • pp.141-149
    • /
    • 1996
  • Lateral dispersion parameter(.sigma.$_{y}$) which is an important factor in atmospheric dispersion can be estimated byusing wind direction fluctuation(.sigma.$_{\theta}$). In this paper, we studied the characteristics of the .sigma.$_{\theta}$ in the Chunchon basin and calculated the .sig- ma.$_{y}$ by using the .sigma.$_{\theta}$. We could find some characteristics of the .sigma.$_{\theta}$ which showed small value, when the atmospheric condition was in weak unstable (C class) and neutral (D class). Moreover, when the atmospheric stability was neutral, there was no difference of .sigma.$_{\theta}$ with wind speed. On the other hand, .sigma.$_{\theta}$ showed large values at the strong unstable (A class) and strong stable (F class) condition with low wind speed. In this case, the .sigma.$_{\theta}$ increased as long as averaging time due to the long-period wind direction fluctuation by the terrain effect. In the result of calculation of .sigma.$_{y}$, it was smaller than that of pasquill-Gifford curve. Especially, when the atmospheric condition was in a neutral and stable, .sigma.$_{y}$ showed small increment as the downwind distance increased.creased.

  • PDF

A Study on the Characteristics of Airborne Trace Metal Elements using Diverse Statistical Approaches in the Daejeon 1st and 2nd Industrial Complex Area (다양한 통계기법을 이용한 대전 1,2 공단지역의 미량금속원소의 특성 연구)

  • 이진홍;장미숙;임종명
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.2
    • /
    • pp.95-112
    • /
    • 2002
  • A precision analysis was conducted for the quantification of trace metal levels in airborne particulates using ICP-MS. According to our study the quantitative analysis using Whatman grade 41 filters produces more precise and representative values of metal concentrations than that using EPM 2000 filters. The mean concentration of PM 10 analyzed during 1998 ~ 2000 was 82 $\mu$g/m$^3$. The concentrations of human carcinogens such as As and Cr were 8.65 and 25.87 ng/m$^3$, respectively, while those of probable human carcinogens such as Cd and Pb were 3.13 and 219.46 ng/m$^3$, respectively. Time-weighted mean concentration, calculated using surface wind speed and direction, indicated that there were differences between metals of crustal origin and metals of anthropogenic origin. The rectorial concentrations of anthropogenic metals and PM 10 were higher for north -west sector with calm or low wind speed conditions than for any other sector with high wind speed conditions. On the contrary, the rectorial concentrations of crustal metals were high with high wind speed. In addition, the sectorial concentrations of crustal metals were more affected by south-west wind directions, which were compared with those of anthropogenic metals. The enrichment factor (EF) values of many anthropogenic metals were higher than 50, while those of crustal metals were lower than 3, respectively. The concentrations of Cr and Ni in Daejeon industrial complex area were 11 times higher than those in the background site of Kuopio in Finland, while that of Pb in the complex area was 22 times higher, respectively.

Study on Rotating Speed of Kite Wind Turbine System and Design of PM Generator (연 풍력시스템의 회전속도 측정 및 발전기 시스템에 적용 가능한 영구자석 발전기 설계에 관한 연구)

  • Shin, Yujeong;Kim, Soo-Hyun;Kim, Jin Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.4
    • /
    • pp.141-147
    • /
    • 2016
  • A direct PM generator has the effect of reducing the mechanical noise and ease of maintenance by eliminating a number of power transmission components. In addition, wind turbines operating at low speed with the advantages of high output, high efficiency, and small size. The generator was designed as a small direct-drive PM generator that can be applied to a kite even at low wind speeds. The RPM (Revolutions Per Minute) of the reel was measured in two ways using a cadence/speedometer sensor and a tachometer while the actual kite. The RPM derived from the experiment was applied to the simulation on the designed generator. The no-load characteristic analysis for the magnetic fields produced for the permanent magnet generator by a permanent magnet and stator winding currents is achieved using a 2D coordinate system. A commercial electromagnetic analysis program, ANSYS Maxwell, was used to model the electromagnetic dynamics.