• 제목/요약/키워드: low water level

검색결과 1,631건 처리시간 0.034초

Investigation of the Water Gas Shift from Reforming Gas for CO Removal (일산화탄소 저감을 위한 개질가스의 전이반응 연구)

  • Kim, Seong-Cheon;Youn, Moon-Jung;Chun, Young-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제31권10호
    • /
    • pp.855-859
    • /
    • 2007
  • Hydrogen as an energy carrier in fuel cell offers perhaps the largest potential benefits of reduced emissions of pollutants and greenhouse gases. The generation of high-purity hydrogen from hydrocarbon fuels is essential for efficient operation of fuel cell. Reduction of carbon monoxide to an acceptable level of 10ppm involves high temperature and low temperature water gas shift (WGS), followed by selective oxidation of residual carbon monoxide. The WGS reactor was designed and tested in this study to produce hydrogen-rich gas with CO to less than 5000 ppm. In the water gas shift operation, gas emerges from the reformer is taken through a high temperature shift (HTS) catalyst to reduce the CO concentration to about $2{\sim}4%$ followed to about 5000 ppm via a low temperature shift (LTS) catalyst.

The Change of Coastal Water Area due to the Development of Mokpo Harbor and Construction of Daebul Industrial Complex(I) (목포항 개발 및 대불 산업단지 조성에 따른 연안해역 변화(I)- 해면 정온도를 중심으로 -)

  • 이중우;정명선
    • Journal of the Korean Institute of Navigation
    • /
    • 제15권2호
    • /
    • pp.87-96
    • /
    • 1991
  • The change of water level at Mokpo Harbour and its adjacent coastal area due to the construction of the Youngsan Estuary Barrage and the Third Land Reclamation Work of estuary barren had been roughly expected. Periodical floods, which occur 2 times per month, are also being observed at the low lying commercial areas near the Mokpo Old Harbor. Although it is said that the highest tidal current component among the tidal current records at the approaching channel to Mokpo Harbor is reduced to 6 kts, because of the esturary barrage, they do not give any precise statement or a deep analysis for the flooding and periodical water level change under certain environmental conditions. Moreover, they never tried the analysis of development plan considering the natural disaster such as typhoon or other extreme conditions. Thus, it is necessary to collect and analyze the data related to floodings, harbor oscillations, currents, and water quality , etc. because of the development considering the extreme condition. Thus, it is necessary to collect and analyze the data related to floodings, harbor oscillations, currents, and water quality, etc. because of the development considering the extreme condition and to evaluate the field observation and measurement, including the numerical model simulation based on the scientific approaches. This study deals the problem of the water level change among the integrated analyses of the coastal area changes. The result can be used for the integrated planning to give a strong foundation and it will contribute to the development of local area.

  • PDF

The Water Quality Assessment based on the Algal Communities and Biotic Indices in Hongcheon river, Gangwon-do (강원도 홍천강의 조류군집과 생물학적 지수에 의한 수질 평가)

  • Baek, Jun Soo;Kim, Hun Nyun;Lee, Ok-Min
    • Journal of Korean Society on Water Environment
    • /
    • 제30권6호
    • /
    • pp.596-604
    • /
    • 2014
  • This research has studied the physicochemical environmental factors and communities of epilithic diatom and phytoplanktons at Hongcheon river from December 2011 to September 2012. In case of TN, the result was hypertrophic, and for TP, it ranged from mesotrophic to eutrophic. As for BOD, Hongcheon river was rated level II or better, according to the water quality level; values were found to be below 3mg/L at most sites. Total of 83 and 114 taxa of epilithic diatom and phytoplanktons respectively, were found during the research. When assessed using the TSI, it ranged from oligomesotrophic to eutrophic. In case of DAIpo, it ranged from 64.1 to 99.5, and TDI ranged from 51.5 to74.0. These results signify good water quality, level B or better, for Hongcheon river. P-IBI was rated moderate to low, which showed higher pollution than other indices. Among the biological water quality measures analyzed in the Hongcheon river study, DAIpo best matches TDI and BOD, while TDI showed greater pollution. Therefore, P-IBI appears to be inappropriate when assessing the domestic small rivers and lakes.

Development of a Sensorless Deep Well Pump Multi-function Controller using Current Detection Method (전류검출 방식의 심정 펌프 센서리스형 다기능 컨트롤러 개발)

  • Lee, In-Jae;Basnet, Barun;Chun, Hyun-Jun;Bang, Jun-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제66권7호
    • /
    • pp.1149-1154
    • /
    • 2017
  • In this paper, we propose a sensorless multi-function controller applicable for deep well water pumps using current detection method. The proposed system overcomes various drawbacks of existing sensored system and additional features like Over current protection function due to overload, Under current protection function for idling at low water level and Relay function for starting single phase motors and acts as a level indicator to detect water lever in real time by the current detection method. A prototype of the multi-function controller system is designed and all of its functions are tested in the laboratory. The application of the proposed controller ensures reduction in the power consumption and maintenance cost in the facilities like water and septic tanks, drainage and waste water system, oil and chemical tanks where deep well pumps are used.

Coexistence between Zostera marina and Zostera japonica in seagrass beds of the Seto Inland Sea, Japan

  • Sugimoto, Kenji;Nakano, Yoichi;Okuda, Tetsuji;Nakai, Satoshi;Nishijima, Wataru;Okada, Mitsumasa
    • Journal of Ecology and Environment
    • /
    • 제41권3호
    • /
    • pp.45-53
    • /
    • 2017
  • Background: There have been many studies on the growth conditions of Zostera marina and Zostera japonica, but few studies have examined how spatial and temporal factors affect growth in established seagrass beds or the distribution range and shoot density. This study aims to clarify the factors that determine the temporal and spatial distribution of Zostera marina and Zostera japonica in the Seto Inland Sea east of Yamaguchi Prefecture. Methods: The study site is in Hiroshima Bay of the Seto Inland Sea, along the east coast of Yamaguchi Prefecture, Japan. We monitored by diving observation to confirm shoot density, presence or absence of both species and observed water temperature, salinity by sensor in study sites. Results: The frequency of occurrence of Zostera marina was high in all seasons, even in water depths of D.L. + 1 to -5 m ($80{\pm}34%$ to $89{\pm}19%$; mean ${\pm}$ standard deviation), but lower (as low as $43{\pm}34%$) near the breakwall, where datum level was 1 to 2 m, and it was further reduced in datum level -5 m and deeper. The frequency of occurrence of Zostera japonica was highest in water with a datum level of +1 to 0 m. However, in datum level of 0 m or deeper, it became lower as the water depth became deeper. Datum level +1 m to 0 m was an optimal water depth for both species. The frequency of occurrence and the shoot density of both species showed no negative correlation. In 2011, the daily mean water temperature was $10^{\circ}C$ or less on more days than in other years and the feeding damage by S. fuscescens in the study sites caused damage at the tips. Conclusions: We considered that the relationship between these species at the optimal water depth was not competitive, but due to differences in spatial distribution, Zostera marina and Zostera japonica do not influence each other due to temperature conditions and feeding damage and other environmental conditions. Zostera japonica required light intensity than Zostera marina, and the water depth played an important role in the distribution of both species.

A Study on Measuring Electrical Capacitance to Access the Volumetric Water Content of Simulated Soil

  • Rial, W.S.;Han, Y.J.
    • Agricultural and Biosystems Engineering
    • /
    • 제1권1호
    • /
    • pp.30-37
    • /
    • 2000
  • Wet porous media representing agronomic soil that contains variable water content with variable electrolyte concentration was measured to study the shape of the curves of the electric double layer capacitance versus frequency (from 10 KHz to 10 MHz. This was done in an attempt to find the lowest practical operating frequency for developing low cost dielectric constant soil moisture probes. Cellulose sponge was used as the porous media. A high frequency electronic bridge circuit was developed for measuring the equivalent network parallel resistance and capacitance of porous media. It appears that the effects of the electric double layer component of the total parallel network capacitance essentially disappear at operating frequencies greater than approximately 25 MHz at low electrolyte concentrations but are still important at 50 MHz at higher concentrations. At these frequencies, the double layer capacitance masks the diffusion region capacitance where true water content capacitance values reside. The general shape of the curve of volumetric water content versus porous media dielectric constant is presented, with an empirical equation representing data for this type of curve. It was concluded that the lowest frequency where dielectric constant values which represent true water content information will most likely be found is between 30 and 50 MHz at low electrolyte concentrations but may be above 50 MHz when the total electrolyte concentration is near the upper level required for most mesophyte plant nutrition.

  • PDF

The devlepment of a MPC controller for water level control in the steam generator of a nuclear power plant (원전 증기발생기 수위제어를 위한 MPC 제어기 개발)

  • 손덕현;한진욱;이환섭;이창구
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.359-359
    • /
    • 2000
  • Generally, level control in the steam generator of a nuclear power plant is difficulty process control, because the low power operating can lead nonminimum phase characteristics(swell and shrink phenomenon) and flow measurement are unreliable and nonlinear characteristics. This paper presents a framework for solving this problem based on the constrained linear model predictive control and introduces the design of method for the level of the controller in the entire operating power of the steam generator, and compares with conventional PI controller.

  • PDF

Design of pole-assignment self-tuning controller for steam generator water level in nuclear power plants (원전 증기 발생기 수위 제어를 위한 자기 동조 제어기 설계)

  • Choi, Byung-Jae;No, Hee-Cheon;Kim, Byung-Kook
    • Journal of Institute of Control, Robotics and Systems
    • /
    • 제2권4호
    • /
    • pp.306-311
    • /
    • 1996
  • This paper discusses the maintenance of the water level of steam generators at its programmed value. The process, the water level of a steam generator, has the nonminimum phase property. So, it causes a reverse dynamics called a swell and shrink phenomenon. This phenomenon is severe in a low power condition below 15 %, in turn makes the start-up of the power plant too difficult. The control algorithm used here incorporates a pole-assignment scheme into the minimum variance strategy and we use a parallel adaptation algorithm for the parameter estimation, which is robust to noises. As a result, the total control system can keep the water level constant during full power by locating closed-loop poles appropriately, although the process has the characteristics of high complexity and nonlinearity. Also, the extra perturbation signals are added to the input signal such that the control system guarantee persistently exciting. In order to confirm the control performance of a proposed pole-assignment self-tuning controller we perform a computer simulation in full power range.

  • PDF

A Study on Awareness for Fluoride of a Christian Church (일부 교인들의 불소 인식도에 대한 연구)

  • Kim, Jae-Keun
    • Journal of environmental and Sanitary engineering
    • /
    • 제24권4호
    • /
    • pp.39-48
    • /
    • 2009
  • This paper investigated an overview of awareness for fluoride in the young christian association. 30% of men and 70% of women knew well the prevention of caries for fluoride and water fluoridation program and showed of 90% in 20's, 10% in 30's and 0.00% in 40's. 54%-known people for fluoride had each 37% of men and 63% of woman, then 46%-unknown people for fluoride had each 56.52% of man and 43.48% of women. This showed women knew well awareness for fluoride than men. This showed high level above 50% awareness for fluoride as 54% of comprehension for fluoride and 50% of water fluoridation program. Awareness of fluoride of the subjects known for fluoride, prevention of caries, effects of tooth and water fluoridation program appeared above 50% level as 54%, 47%, 45% and 50%, individually. Thus, tooth management in christian showed high level. But, awareness for fluoride of women in third condition 'unknown for mottled tooth' showed each 38%, 34% and 37%. The mottled tooth from an excessive fluoride appeared low level awareness for fluoride of women. It suggested hard scientific contents made woman subjects unknown the effects of fluoride for tooth.

Numerical Analysis in Hydrograph Determination for Sluice Gate installed Levee (배수통문이 설치된 제방의 설계수위파형결정에 관한 수치해석)

  • Kim, Jin-Man;Choi, Bong-Hyuck;Oh, Eun-Ho;Cho, Won-Beom
    • Journal of the Korean Geosynthetics Society
    • /
    • 제14권4호
    • /
    • pp.1-9
    • /
    • 2015
  • According to national regulations and its commentary, such as Rivers Design Criteria & Commentary (KWRA, 2009), Foundation Structure Guideline and its Commentary(MLTM, 2014 and KGS, 2009), the integrity evaluation of river levee includes slope stability evaluation of both riverside/protected low-land and piping stability evaluation with respect to foundation and levee body along with water level conditions. In this case the design hydro-graph can be the most important input factor for the integrity evaluation, however it is fact that the national regulations do not provide any proper determination methods regarding hydro-graph. The authors thus executed an integrity evaluation of sluice gate in levee by changing each hydro-graph factor, including rising ordinary water level, lasting flood water level, falling water level, and flood frequency, in order to suggest a determination method of reasonable hydro-graph. As a result, the authors suggested that at least over 57 hours of rising ordinary water level and over 53 hours of lasting flood water level should be considered for the design hydro-graph of sluice gate in levee at Mun-san-jae.