• Title/Summary/Keyword: low velocity

Search Result 2,854, Processing Time 0.032 seconds

Air Side Heat Transfer Charactieristics of Tension Wound Transverse Fin with Minichannel (장력 감김으로 부착된 가로방향 휜-미니채널의 공기측 열전달 특성)

  • Kim Jong-Soo;Im Yong-Bin
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.6
    • /
    • pp.701-706
    • /
    • 2005
  • Pipes, tubes. and tubular sections with external transverse high fins have been used extensively for heating cooling, and degumidifying air and other gases. This work was performed to investigate an air side heat transfer charactieristics of minichannel with tension wound transverse fin. This estimate was confirmed conversion heat capacity the air side surface area enlargement and heat transfer charactieristics performed available inlet tube side hot water mass flux or outlet tube side air frontal air velocity. The most suitable tension wound transverse finned minichannel was measured extremely low in air side pressure drop and fin effectiveness $3.3\~4.4$. The pressure drop $0.9\~2.8Pa$ was ranged frontal air velocity $0.5\~1.2m/s$. It is also appeared that heat transfer in air side could be better conversion heat area which has been increased $330\%$ of heat capacity compared with the bare tube.

Residual stress Analysis of Inclined Shot Peening Using Finite Element Method (유한요소법을 이용한 경사쇼트피닝의 잔류응력 해석)

  • Baek, Seung;Yang, Won-Ho;Seok, Chang-Sung;Ryu, Meong-Hae
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.328-333
    • /
    • 2003
  • The purpose of this study is to analyze the impact of shot peening angle on residual stress distribution. From the residual stress analysis of perpendicular shot peening, it could be known that the residual stress in the case of high velocity is larger than low velocity, but the amount of shot size has little effect on the magnitude of compressive residual stress. The centroidal residual stress is not greatly affected by the inclined shot peening but mainly related to the unstable conditions of surface residual stress field. Therefore, this tendency may lead to reduce fatigue life of treated material.

  • PDF

NUMERICAL INVESTIGATION OF VORTICAL FLOW INDUCED BY A SYNTHETIC JET ACTUATOR (Synthetic Jet 주위 유도 와류에 대한 수치 해석)

  • Park, S.H.;Sa, J.H.;Yu, Y.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.120-125
    • /
    • 2006
  • Piezoelectric actuators have been investigated for flow control in the field of fluid dynamics. Numerical simulation for a single diaphragm piezoelectric actuator operating in quiescent air is performed to investigate the complex flow field around the slot exit. A periodic velocity transpiration condition is applied to simulate the effect of the moving diaphragm. The computational results for the flow field around the slot exit agree well with the experimental data. The results also show that low pressure regions due to the vortex pairing cause non-monotonic variations in the vertical velocity.

  • PDF

A Study on the Flow Characteristics of the Spiral Flow Nozzle with the Width Change of Annular Slit

  • Kim, T.H.;Setoguchi, T.;Lee, Y.W.
    • Journal of the Korean Society of Visualization
    • /
    • v.7 no.1
    • /
    • pp.14-20
    • /
    • 2009
  • In comparison with previous researches fur swirling flow, the spiral flow self-generated in the spiral flow nozzle has some different characteristics. It is not needed a compulsive tangential momentum to get its velocity component and has long potential core, relatively low swirl ratio, and high focusing ability. In this study, the self-generated mechanism of the spiral flow was clarified and the effect on the width of annular slit on spiral flow characteristics was investigated experimentally and numerically. As a result, the existence of tangential velocity component regardless of a compulsive angular momentum is clarified and the results obtained by experiment have a satisfactory agreement with those by numerical method, quantitatively and qualitatively.

A Study on the Flow Characteristics with the Width of Annular Slit in Spiral Flow Nozzle

  • Kim, T.H.;Setoguchi, T.;Lee, Y.W.
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.143-148
    • /
    • 2007
  • In comparison with previous researches for swirling flow, the spiral flow self-generated in the spiral flow nozzle has some different characteristics. It is not needed a compulsive tangential momentum to get its velocity component and has long potential core, relatively low swirl ratio, and high focusing ability. In this study, the self-generated mechanism of the spiral flow was clarified and the effect on the width of annular slit on spiral flow characteristics was investigated experimentally and numerically. As a result, the existence of tangential velocity component regardless of a compulsive angular momentum is clarified and the results obtained by experiment have a satisfactory agreement with those by numerical method, quantitatively and qualitatively.

  • PDF

Improvement of the Thermal Characteristics of Synchronous Linear Motors through Structure Change (Synchronous Linear Motor의 구조변경에 의한 열특성에 개선)

  • 은인웅;이춘만;정원지;최영휴
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.367-370
    • /
    • 1997
  • Linear motors can drive a linear motion without intermediate gears, screws or crank shafts. Linear motors can successfully replace ball lead screw in machine tools because they have a high velocity, acceleration and good positioning accuracy. On the other hand, linear motors emit large amounts of heat and have low efficiency. In this paper, the thermal behavior of a synchronous linear motor with high velocity and force is analyzed. To improve the thermal characteristics of the linear motor, structure of linear motor and cooler is changed. Some effects of an integrated cooler, an U-cooler and a thermal symmetrical cooler are presented.

  • PDF

Characteristics of Vertically Injected Buoyant Jet of Highly Diluted Propane (과다 희석된 프로판제트의 상향분사시 부력에 의한 유동특성)

  • Chun Kang Woo;Kim Junhong;Won Sang Hee;Chung Suk Ho
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.529-532
    • /
    • 2002
  • In coflow jets with relatively large size nozzle and low fuel jet velocity, the buoyancy effect arises from the density difference between fuel and air streams. The present study investigated the behavior of such a buoyant cold Jet both numerically and experimentally, especially when the fuel stream has higher density than air. It has been demonstrated that the cold jet has a circular cone shape since upwardly injected fuel jet decelerates and forms a stagnation region, when the fuel jet was composed of propane highly diluted with nitrogen. When the fuel was moderately diluted, numerical results showed the Kelvin-Helmholtz type instability along the mixing layer of the jet. The stagnation height increases nonlihearly with fuel jet velocity with the power of approximately 1.64.

  • PDF

Measurements of Temperature and Flow Fields with Sub-Millimeter Spatial Resolution Using Two-Color Laser Induced Fluorescence (LIF) and Micro-Particle Image Velocimetry (PIV)

  • Kim Hyun Jung
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.716-727
    • /
    • 2005
  • Comprehensive measurements for velocity and temperature fields have been conducted. A Micro PIV 2-color LIF system have been setup to measure the buoyancy driven fields in a 1-mm heated channel with low Grashof-Prandtl numbers [$86]. Fluorescence microscopy is combined with an MPIV system to obtain enough intensity images and clear pictures from nano-scale fluorescence particles. The spatial resolution of the Micro PIV system is $75{\mu}m\;by\;67{\mu}m$ and error due to Brownian motion is estimated $1.05\%$. Temperature measurements have achieved the $4.7\;{\mu}m$ spatial resolution with relatively large data uncertainties the present experiment. The measurement uncertainties have been decreased down to less than ${\pm}1.0^{\circ}C$ when measurement resolution is equivalent to $76\;{\mu}m$. Measured velocity and temperature fields will be compared with numerical results to examine the feasibility of development as a diagnostic technique.

An Experimental Investigation of Unsteady Mixed Convection in a Horizontal Channel with Cavity Using Thermo-Sensitive Liquid Crystals

  • Bae, Dae-Seok;Cai, Long-Ji;Kim, Eun-Pil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.7
    • /
    • pp.987-993
    • /
    • 2009
  • An experimental study is performed to investigate unsteady mixed convection in a horizontal channel with a heat source. Particle image velocimetry (PIV) with thermo-sensitive liquid crystal (TLC) tracers is used for visualization and analysis. This method allows simultaneous measurement of velocity and temperature fields at a given instant of time. Quantitative data of the temperature and velocity are obtained by applying the color-image processing to a visualized image, and neural network is applied to the color-to-temperature calibration. It is found that the periodic flow of mixed convection in a cavity appears at very low Reynolds numbers (Re<0.4), and the period decreases with increasing Reynolds numbers and increases with increasing aspect ratio.

Limitations of time resolution and spatial overlap caused by group velocity mismatch in experiments using ultrashort UV and visible optical pulses. (자외선과 가시광선 극초단 펄스 실험의 군속도 차이에 의한 시간 분해능 및 공간 겹침의 제한)

  • 김성규
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.252-259
    • /
    • 1994
  • The method of calculating overlap dispersion caused by group velocity mismatch between uv and visible pulses in ultrafast pump-probe experiments is presented to discuss limitations of the time resolution and signal intensity. The calculations show arrangements using a single focusing lens shall result in undesirable time resolution and low signal intensity. Achromatic doublets result in unrealistic solutions. However, dramatic improvement in the time resolution and signal intensity is expected in the optical arrangements using separate lens for each pulse and in the arrangements using a cutoff secondary lens with a main lens. lens.

  • PDF