• Title/Summary/Keyword: low velocity

Search Result 2,854, Processing Time 0.026 seconds

Estimations and Long-term Trend of Sea-to-air Dimethyl Sulfide (DMS) Flux using Satellite Observation Data (인공위성 관측 자료를 이용한 해양-대기 DMS flux 추정 및 장기 추세 분석)

  • Choi, Yu-Na;Song, Sang-Keun;Han, Seung-Beom;Son, Young-Baek;Park, Yeon-Hee
    • Ocean and Polar Research
    • /
    • v.39 no.3
    • /
    • pp.181-194
    • /
    • 2017
  • The long-term linear trend of global sea-to-air dimethyl sulfide (DMS) flux was analyzed over a 16-year time span (2000~2015), based on satellite observation data. The emission rates of DMS (i.e. DMS flux) in the global ocean were estimated from sea surface DMS concentrations, which were constructed with chlorophyll a (Chl-a) concentrations and mixed layer depths (MLD), and transfer velocity from sea to air, which was parameterized with sea surface wind (SSW) and sea surface temperature (SST). In general, the DMS flux in the global ocean exhibited a gradual decreasing pattern from 2000 (a total of 12.1 Tg/yr) to 2015 (10.7 Tg/yr). For the latitude band ($10^{\circ}$ interval between $0^{\circ}$ and $60^{\circ}$), the DMS flux at the low latitude of the Northern (NH) and Southern hemisphere (SH) was significantly higher than that at the middle latitude. The seasonal mean DMS flux was highest in winter followed by in summer in both hemispheres. From the long-term analysis with the Mann-Kendall (MK) statistical test, a clear downward trend of DMS flux was predicted to be broad over the global ocean during the study period (NH: $-0.001{\sim}-0.036{\mu}mol/m^2/day\;per\;year$, SH: $-0.011{\sim}-0.051{\mu}mol/m^2/day\;per\;year$). These trend values were statistically significant (p < 0.05) for most of the latitude bands. The magnitude of the downward trend of DMS flux at the low latitude in the NH was somewhat higher than that at the middle latitude during most seasons, and vice versa for the SH. The spatio-temporal characteristics of DMS flux and its long-term trend were likely to be primarily affected not only by the SSW (high positive correlation of r = 0.687) but also in part by the SST (r = 0.685).

Research for Crack Generation and Propagation of Daejeon Granite under Stress Conditions (대전 화강암에 대한 가압 조건하에서의 암석 균열 발생과 성장에 관한 연구)

  • Choi, Junghae;Kim, Hye-jin;Chae, Byung-gon
    • Economic and Environmental Geology
    • /
    • v.52 no.6
    • /
    • pp.587-593
    • /
    • 2019
  • This study were subjected to accelerated weathering test under freeze-thaw and pressure conditions to observe initiation and propagation of cracks using CLSM. Applied stress was set at 50 MPa, 55 MPa, 70 MPa for 3 samples each by using compressor and freeze-thaw experiment was conducted while samples maintained that condition. In freeze-thaw experiments, a temperature range was set to -20~40℃ which was 1 cycle for 6 hours. The freeze-thaw cycle was composed of time which reached to set temperature for 1 hour and holding time for 2 hours. On the basis of this cycle, surface of samples was observed by CLSM after each 20 freeze-thaw cycle. From this research, according to increase freeze-thaw cycle, there were 7, 10, 19 each cracks and High pressured sample's accumulate length was longer than low pressured sample's. High pressured sample's crack velocities were also faster than low pressured sample's which were calculated by accumulate length and freeze-thaw cycle.

A Study on Low-Temperature Oxidation Reactivity of Pt/ZrO2·SO42-Catalyst (ZrO2·SO42-에 담지된 백금촉매의 저온산화반응성에 대한 연구)

  • Kim, Kiseok;Lee, Tae Jung;Kim, Byoung Sam;Kim, Du Soung
    • Applied Chemistry for Engineering
    • /
    • v.9 no.1
    • /
    • pp.141-148
    • /
    • 1998
  • Reactivity of Pt catalysts(0.2, 0.5 wt% Pt) supported on solid super acid, $ZrO_2$ $SO_4{^{2-}}$ for low-temperature oxidation was investigated for complete oxidation of cyclohexane. Catalytic activity measured as reactant conversion in a packed-bed tubular reactor increased in accordance with the acidity and specific surface area of the catalyst activity and specific surface area of $Pt/ZrO_2$ $SO_4{^{2-}}$ catalyst were diminished by adding potassium during catalyst preparation. the catalyst activity decreased in accordance with the amount of potassium added. In addition, $Pt/ZrO_2$ $SO_4{^{2-}}$ catalyst exhibited an activity greater than that of a $Pt/SiO_2$ or $Pt/Al_2O_3$ catalyst possessing much larger specific surface area at $250^{\circ}C$ for the reactant stream of 15.000 ppm cyclohexane concentration and $18,000hr^{-1}$ space velocity, a cyclohexane conversion as high as 96% was obtained over 0.2 wt% $Pt/ZrO_2$ $SO_4{^{2-}}$, whereas cyclohexane conversions over 0.2 wt% $Pt/SiO_2$ and 0.2 wt% $Pt/Al_2O_3$ were 83 and 79%, respectively.

  • PDF

The Experiment for the Technical Balance Work on the Automatic Silk Reeling Machine ( I ) (자동조사기 기술체계확립을 위한 시험 (I))

  • 최병희;송기언;유시환;김화연;이용우
    • Journal of Sericultural and Entomological Science
    • /
    • v.13 no.2
    • /
    • pp.155-160
    • /
    • 1971
  • This experiment was carried out to investigate the cocoon reeling condiditions required to technical balance work on the automatic silk reeling machine. The results obtained were as follows. 1) Reasonable reeling velocity with regard to raw silk yield and to reeling efficiency varied according to cocoon reelability. It was observed to be about 150m/min on good reelability cocoon (850m of nonbreaking bave length), about 120m/min on medium reelability cocoon (650m of nonbreaking bave length) and from 90m/min to 120m/min on bad reelability cocoon (500m of nonbreaking bave length) 2) Low temperature drying of cocoon (T$_3$) improved the reelability of cocoon, but increased the reeling accidance with deteriorating the quality of raw silk more than the control(T$_1$) or high temperature drying of cocoon (T$_2$). No significant difference was observed in its raw silk yield and silk by-product with regard to cocoon drying temperature. 3) Incomplete drying of cocoon (T$_3$) improved the reelability of cocoon, but increased the reeling accidance with deteriorating the quality of raw silk more than the control(T$_1$) or over drying of cocoon(T$_2$). No significant difference was observed in its raw silk yield and silk by-product with regard to cocoon drying degree. It was cocoon drying condition of cocoon was the control(T$_1$) or high temperature(T$_2$) rather than low temperature (T$_3$) in cocoon drying process. Control (T$_1$) or over drying of cocoon (T$_2$) was adequate rather than incomplete drying of cocoon (T$_3$) for the improvement of the quality of raw silk on the automatic silk reeling process. 4) It was found that the reasonable cooking condition of cocoon was optimum cooking with 4$0^{\circ}C$ of reeling temperature or incomplete cooking with 45$^{\circ}C$ of the reeling temperature in the automatic silk reeling of the domestic cocoon.

  • PDF

Flow analysis of the Sump Pump (흡수정의 유동해석)

  • Jung, Han-Byul;Noh, Seung-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.673-680
    • /
    • 2017
  • sump pump is a system that draws in water that is stored in a dam or reservoir. They are used to pump large amounts of water for cooling systems in large power plants, such as thermal and nuclear plants. However, if the flow and sump pump ratio are small, the flow rate increases around the inlet port. This causes a turbulent vortex or swirl flows. The turbulent flow reduces the performance and can cause failure. Various methods have been devised to solve the problem, but a correct solution has not been found for low water level. The most efficient solution is to install an anti-vortex device (AVD) or increase the length of the sump inlet, which makes the flow uniform. This paper presents a computational fluid dynamics (CFD) analysis of the flow characteristics in a sump pump for different sump inlet lengths and AVD types. Modeling was performed in three stages based on the pump intake, sump, and pump. For accurate analysis, the grid was made denser in the intake part, and the grid for the sump pump and AVD were also dense. 1.2-1.5 million grid elements were generated using ANSYS ICEM-CFD 14.5 with a mixture of tetra and prism elements. The analysis was done using the SST turbulence model of ANSYS CFX14.5, a commercial CFD program. The conditions were as follows: H.W.L 6.0 m, L.W.L 3.5, Qmax 4.000 kg/s, Qavg 3.500 kg/s Qmin 2.500 kg/s. The results of analysis by the vertex angle and velocity distribution are as follows. A sump pump with an Ext E-type AVD was accepted at a high water level. However, further studies are needed for a low water level using the Ext E-type AVD as a base.

Effects of Joint Mobilization Techniques on the Joint Receptors (관절 가동운동(mobilization)이 관절 감수기(joint receptors)에 미치는 영향)

  • Kim, Suhn-Yeop
    • Physical Therapy Korea
    • /
    • v.3 no.2
    • /
    • pp.95-105
    • /
    • 1996
  • Type I, II, III are regarded as "true" joint receptors, type IV is considered a class of pain receptor. Type I, II and III mechanoreceptors, via static and dynamic input, signal joint position, intraarticular pressure changes, and the direction, amplitude, and velocity of joint movements. Type I mechanoreceptor subserve both static and dynamic physiologic functions. Type I are found primarily in the stratum fibrosum of the joint capsule and ligaments. Type I receptors have a low threshold for activation and are allow to adapt to changes altering their firing frequency. Type II receptors have a low threshold for activation. These dynamic receptors respond to joint movement. Type II receptors are thus termed rapidly adapting. Type II joint receptors are located at the junction of the synovial membrane and fibrosum of the joint capsule and intraarticular and extraarticular fat pads. Type III receptors have been found in collateral ligaments of the joints of the extremities. Morphologically similar to Golgi tendon organ. These dynamic receptors have a high threshold to stimulation and are slowly adating. Type IV receptors possess free nerve ending that have been found in joint capsule and fat pads. They are not normally active, but respond to extreme mechanical deformation of the joint as well as to direct chemical or mechanical irritation. Small amplitude oscillatory and distraction movements(joint mobilization) techniques are used to stimulate the mechanoreceptors that may inhibit the transmission of nociceptors stimuli at the spinal cord or brain stem levels.

  • PDF

Gender Differences in Physiological Effects of a Transient Exposure to Experimental Noise

  • Hyun, Kyung-Yae;Kim, Chong-Rak;Kim, Hwa-Il;Kim, Young-Hwal;Choi, Seok-Cheol
    • Biomedical Science Letters
    • /
    • v.12 no.4
    • /
    • pp.375-383
    • /
    • 2006
  • The physiological responses following stress are different in individual or personality. We performed this study to clarify gender differences in influences of noise stress on physiological factors. 70 healthy subjects, which was divided man (n=30) and woman (n=40) groups, were exposed to 85 decibels of excavator noise for 15 minutes. Cardiac factors such as heart rate (HR), systolic and diastolic blood pressures (SBP and DBP, respectively), and heart rate-systolic pressure product (RPP) were determined. Transcranial Doppler ultrasound (TCD) was used to measure mean blood flow velocity (Vm), pulsatility index (PI), and resistance index (RI) in the middle, anterior and posterior cerebral arteries (MCA, ACA and PCA, respectively) before and during noise exposure. Cortisol level and hematological variables were also measured before (baseline) and immediately after the end of noise exposure. In the both groups HR, SBP, and RPP significantly decreased during noise exposure (P<0.05) but not significantly different between two groups (P>0.05). Vms of three cerebral arteries in man group decreased, whereas Vm of PCA in woman group fell during noise exposure (P<0.05). Vm, PI and RI in MCA and ACA during noise exposure were low in man group compared with woman group (P<0.05). Vm of PCA was low, whereas PI and RI of PCA were high in man group compared with woman group during noise exposure (P<0.05). Total leukocyte and red blood cell (RBC) counts slightly decreased during noise exposure but not significant (P>0.05). Levels in hematological variables decreased but not significant changed following noise exposure. Decreased rate of total leukocyte in man group was higher (P<0.05). Cortisol levels in the both groups decreased immediately after the end of noise exposure, while the decreased rate in man group was greater than that in woman group (p<0.05). These findings indicate that a transient exposure to experimental excavator noise may cause decreased changes in cardiac factors, cerebral hemodynamics and cortisol levels and the changes may be greater in men than in women.

  • PDF

A Study on the Combustion Characteristics of Diffusion Flame with the Fuel Injection Condition (연료분출 조건에 따른 확산화염의 연소특성에 관한 연구)

  • Lee, Sung-No;An, Jin-Geun
    • Clean Technology
    • /
    • v.13 no.4
    • /
    • pp.300-307
    • /
    • 2007
  • The combustion characteristics of diffusion flame formed in the wake of a cylindrical stabilizer with varying fuel injection angle were studied. This study was performed by measuring the flame stability limits, lengths and temperatures of recirculation zones of flames, turbulence intensity in the wake of stabilizer, and concentration distribution of combustion gas, and by taking photographs of flames. The flame stability limits are dependent on fuel injection angle and main air velocity. The length and temperature of recirculation zone are dependent on fuel injection angle. As the length of the recirculation zone is decreased, the flame shows more stable behavior. The temperature of recirculation zone has a maximum value at the condition of theoretical mixture. The flame stability is enhanced when the temperature in the recirculation zone decreases. The turbulence intensity in the wake of stabilizer is independent of the fuel injection angle, but it is affected by stabilizer itself and main air flow condition. If the stabilization characteristics of flame is good, the concentration of $C_3H_8$ is high, but the concentration of $CO_2$ is low at the boundary of recirculation zone. The combustion characteristics of diffusion flame can be controlled by changing the fuel injection angles. The appropriate fuel injection angle should be selected to get high combustion efficiency, high load power, low environmental pollution, and clean combustion condition of fuel.

  • PDF

Variability of Sea Levels at Mukho and Ullungdo off the East Coast of Korea (한국 동해 묵호와 울릉도의 해수면의 변화)

  • LEE Jae-Chul;KIM Soon-Young
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.24 no.6
    • /
    • pp.413-427
    • /
    • 1991
  • Variability of sea levels at Mukho and Ullungdo and sea level difference(SLD) associated with current is investigated. Time series of adjusted sea levels at both places have very similar pattern of change. Two components appear to contribute to the correlation between sea level and SLD. Low frequency thermosteric effect causes the sea level to rise and fall at the same time. Geostrophic effect of major currents is responsible for the sea level change in opposite ways at both sides. Two contributions have a cancelling effect for sea level change at Mukho while they are additive at Ullungdo. Characteristics of time series in frequency domain are divided into two parts with respect to 0.01 cycles per day(cpd). At Mukho, the cancelling effect yields small values of coherence for low-frequency bands whereas the dominant geostrophic influence may be responsible for the phase relations of about $\pm 180^{\circ}$ between sea level and SLD at higher frequency. Bimonthly dynamic height difference(DHD) between Mukho and Ullungdo is very significantly correlated with SLD. This result suggests that DHD thus the average velocity of current through the Mukho-Ullungdo section can successfully be diagnosed by the sea level records at both locations. For the annual variations, maximum SLD occurs at Mukho-Ullungdo section about 40 days later than the Korea Strait.

  • PDF

Temperature and Flow Velocity Analysis for Fire in Synthetic Heat Transfer Fluid Boiler (열매유 보일러 내부화재에 따른 온도 및 속도분포 해석)

  • Kim, Yeob-Rae;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.19-25
    • /
    • 2013
  • The fire took place in the synthetic heat transfer fluid boiler. This study uses simulation to investigate the first, second and third passes and the temperature in the fire burner. The boiler's internal fluid is more or less unsteady due to the out of order inverter. As the operation continues, the flame's flow and speed are unsteady. The synthetic heat transfer fluid leak spouted about 120 kg/min in the form of vapor in the early period of the fire. The flame extended to the second and third passes. The highest temperature of the second and third pass is $1059^{\circ}C$ and $1007^{\circ}C$, respectively. The simulation shows that the temperature is $767^{\circ}C$ in the low part of the third pass. The synthetic heat transfer fluid spouted through the cracked part of the fire box in the first pass and accumulated on the turn table. The temperature rises to $183^{\circ}C$ in the low part of the burner. Therefore, it is expected that the temperature of the interior of the fire box is above $1200^{\circ}C$. The temperature of the burner rises to a maximum level several times in a short period. On account of that, several explosions occur in the fire burner.