• Title/Summary/Keyword: low velocity

Search Result 2,854, Processing Time 0.036 seconds

Efficiency Evaluation of Adsorbents for the Removal of VOC and NO2 in an Underground Subway Station

  • Son, Youn-Suk;Kang, Young-Hoon;Chung, Sang-Gwi;Park, Hyun-Ju;Kim, Jo-Chun
    • Asian Journal of Atmospheric Environment
    • /
    • v.5 no.2
    • /
    • pp.113-120
    • /
    • 2011
  • Adsorbent combination studies have been carried out to remove nitrogen dioxide ($NO_2$) and volatile organic compounds (VOCs: BTEX) out of a subway environment characterized by high flow and low concentration. Optimal conditions for the high removal efficiency of the concerned target compounds were obtained through testing a series of control factors such as adsorbent sorts, thicknesses, and superficial velocity. It was found that the efficiencies increased as the specific surface area of activated carbon and its thickness increased, and external void fraction decreased. Furthermore, mixed activated carbon with granular and constructed contents was extensively tested to reduce pressure drop through the carbon bed. It was found that the performance of higher contents of granular activated carbon was better than that of higher contents of the constructed carbon. When the mixed carbon was applied to the subway ventilation system in order to eliminate $NO_2$ and VOC simultaneously, the removal efficiencies were found to be 75% and 85%, respectively.

Characterization of Spermidine Transport System in a Cyanobacterium, Synechocystis sp. PCC 6803

  • Raksajit, Wuttinun;Yodsang, Panutda;Maenpaa, Pirkko;Incharoensakdi, Aran
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.5
    • /
    • pp.447-454
    • /
    • 2009
  • The transport of spermidine into a cyanobacterium, Synechocystis sp. pec 6803, was characterized by measuring the uptake of $^{14}C$-spermidine. Spermidine transport was shown to be saturable with an apparent affinity constant ($K_m$) value of $67{\mu}M$ and a maximal velocity ($V_{max}$) value of 0.45 nmol/min/mg protein. Spermidine uptake was pH-dependent with the pH optimum being 8.0. The competition experiment showed strong inhibition of spermidine uptake by putrescine and spermine, whereas amino acids were hardly inhibitory. The inhibition kinetics of spermidine transport by putrescine and spermine was found to be noncompetitive with $K_i$ values of 292 and $432{\mu}M$, respectively. The inhibition of spermidine transport by various metabolic inhibitors and ionophores suggests that spermidine uptake is energy-dependent. The diminution of cell growth was observed in cells grown at a high concentration of NaCl. Addition of a low concentration of spermidine at 0.5 mM relieved growth inhibition by salt stress. Upshift of the external osmolality generated by either NaCl or sorbitol caused an increased spermidine transport with about 30-40% increase at 10 mosmol/kg upshift.

In-cylinder Spray Flow Characteristics in Direct-injection Gasoline Engine (직접 분사식 가솔린 엔진의 실린더 내 분무 유동 특성에 관한 연구)

  • 김진수;전문수;윤정의
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.6
    • /
    • pp.51-59
    • /
    • 2000
  • In-cylinder spray flow motion plays an important in the adjustment of mixture preparation with a fundamental spray characteristics and in-cylinder flow field well in direct-injection gasoline engine. In this study, the fundamental spray characteristics such as mean drop size, velocity distribution, spray angle were measured and in-cylinder spray flow motion was visualized in order to optimize intake port, piston top land and combustion chamber shapes in the development stage of mass-produced G야 engine. For these experiments, the PDPA measurements and Mie scattering technique were used for detailed spray characteristics and in-cylinder spray motions were obtained by use of ICCD camera through the single-cylinder optical engine. From the experimental results, the test injector shows a good low-end linearity between the dynamic flow and fuel injection pulse width and the fuel spray of 20mm or less in SMD with good spray symmetry. In addition, the in-cylinder tumble flow has more effect on the homogeneous mixture formation than that of in-cylinder swirl flow at early injection mode and the in-cylinder swirl flow plays a better role of stratified mixture preparation than tumble flow at late injection mode.

  • PDF

The Effects of Zeolite Structure and Ion-exchange Material on NH3-SCR Reaction (제올라이트 종류 및 이온교환 물질에 따른 NH3-SCR 촉매 반응 특성)

  • Hwang, Inhye;Lee, Junho;Kim, Hongsuk;Jeong, Youngil
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.1
    • /
    • pp.135-141
    • /
    • 2014
  • $NH_3$-SCR has high NOx removal efficiency approximately 80~90%. Recently, the copper or iron ion-exchanged zeolite catalysts are widely used as automobile SCR catalysts. In this paper, the effect of the space velocity, temperature of reaction and $NO_2$ addition on the $NH_3$-SCR reaction were studied using various zeolite SCR catalysts. The test was conducted with small sized fresh catalysts in a laboratory fixed-bed flow reactor system using simulated gases. It is found that the activity of the BEA is better than MFI. It seems that three-dimensional framework and a wide pore entrance of BEA enhances the SCR activity. It is also found that low temperature activity of Cu-zeolites was better than Fe-zeolites. Once $NO_2$ was added, the NOx conversion activity of the Cu-zeolite was slightly enhanced, whereas remarkable improvement was achieved by Fe-zeolite.

Predictive analysis on explosive performance of methylnitroimidzole derivatives (메틸나이트로이미다졸 유도체의 화약성능 예측분석)

  • Rim, One Kwon
    • Analytical Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.347-352
    • /
    • 2015
  • Chemical properties such as heat of formation and density of methylnitroimidazole derivatives were predicted and analyzed by using density functional theory (DFT). Successive addition of energetic nitro groups into an imidazole ring increases both the heat of formation and the density. Using the chemical property values computed by DFT, explosive performance was analyzed with the Cheetah program, and compared with those of TNT, RDX, and HMX, which are currently used widely in military systems. When both C-J pressure and detonation velocity were used as explosive performance, methyldinitroimidazole derivatives show better performance than TNT, while methyltrinitroimidzole is almost close to RDX. Since methylnitroimidazole derivatives have a good merit, i.e. low melting point for melt loading, they are forecasted to be used widely in various military and civilian application.

Experimental Study on Edge Flame Instabilities in Solid Rocket Combustion (고체로켓연소에서 에지화염 불안정성에 대한 실험적 연구)

  • Hwang Dong-Jin;Park Jeong;Kim Jeong-Soo;Kim Sung-Cho;Kim Tae-Kwon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.279-282
    • /
    • 2006
  • Experiments in low strain rate methane-air counterflow diffusion flames diluted with $CO_2$ have been conducted to investigate the flame extinction behavior and edge flame oscillation The critical mole fraction at flame extinction is examined in terms of velocity ratio and global strain rate. Onset conditions of the edge flame oscillation and the relevant modes are also provided with global strain rate. It is observed that flame length is intimately relevant to lateral heat loss, and this affects flame extinction and edge flame oscillation considerably. Edge flame oscillations are categorized into three: a growing-, a decaying-, and a harmonic-oscillation mode.

  • PDF

A Numerical Study of the Spray Characteristics of Co-axial Swirl Injector in Liquid Propellant Rocket Engine (액체로켓엔진에서 동축 스월형 분사기의 분무특성에 대한 수치적 고찰)

  • Moon Yoon-Wan;Seol Woo-Seok;Yoon Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.156-160
    • /
    • 2006
  • This study investigated the characteristics of spray generated by a liquid-liquid co-axial swirl injector used in a combustor of the liquid rocket engine. The linear stability analysis[1] was introduced In liquid sheet breakup and Post[2]'s collision model which considers shattering was adopted on the collision model after breakup. Every model was implemented to KIVA[3], which was adopted as solve. To validate the implemented models the cases of high and low injection velocity were calculated respectively and each result agreed well with test results.

  • PDF

A Study of the Myoelectronic Hand for a Hand Amputee (상지절단 장애인용 전동의수에 관한 연구)

  • Kim, Myung-Hoe;Jang, Dae-Jin
    • Journal of Korean Physical Therapy Science
    • /
    • v.9 no.2
    • /
    • pp.133-141
    • /
    • 2002
  • This purpose of this study was to design the effect of recovering of a hand amputees by Myoelectronic hand. It was designed with 2 degree of freedom in the laboratory. Myoelectronic hand had only one degree of freedom and one movement until now. Also this myoelectronic hand had multi-joint and it could move widely. Wire was used in transmission. Myoelectronic hand data was obtained by analyzing hand anatomically and measuring and that data was applied when it was designed. PID controller of Myoelectronic hand was used to it. Displacement control was applied the first link. Experiment was accomplished in Tip grasp, Power grasp and Hook grasp modes. Displacement control was good in low frequency. Velocity control was applied to each mode. The objective of the study was to develop more better multifunction myoelectronic control strategies. A myoelectronic hand with a hand amputees could do some jobs such as grasping materials, lifting weighting, holding cup and etc. As a result of this study, all subjects with hand amputees significantly improved in ADL. Further studies were needed to evaluate the effect of a myoelectronic hand with more precise laboratory equipment.

  • PDF

A CFD Study of Near-field Odor Dispersion around a Cubic Building from Rooftop Emissions

  • Jeong, Sang Jin
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.3
    • /
    • pp.153-164
    • /
    • 2017
  • Odor dispersion around a cubic building from rooftop odor emissions was investigated using computational fluid dynamics (CFD). The Shear Stress Transport (here after SST) $k-{\omega}$ model in FLUENT CFD code was used to simulate the flow and odor dispersion around a cubic building. The CFD simulations were performed for three different configurations of cubic buildings comprised of one building, two buildings or three buildings. Five test emission rates were assumed as 1000 OU/s, 2000 OU/s, 3000 OU/s, 4000 OU/s and 5000 OU/s, respectively. Experimental data from wind tunnels obtained by previous studies are used to validate the numerical result of an isolated cubic building. The simulated flow and concentration results of neutral stability condition were compared with the wind tunnel experiments. The profile of streamline velocity and concentration simulation results show a reasonable level of agreement with wind tunnel data. In case of a two-building configuration, the result of emission rate 1000 OU/s illustrates the same plume behavior as a one-building configuration. However, the plume tends to the cover rooftop surface and windward facet of a downstream building as the emission rate increases. In case of a three-building configuration, low emission rates (<4000 OU/s) form a similar plume zone to that of a two-building configuration. However, the addition of a third building, with an emission rate of 5000 OU/s, creates a much greater odorous plume zone on the surface of second building in comparison with a two-building configuration.

Buoyancy Effect on Stable and Oscillating Lifted Flames in Coflow Jets for Highly Diluted Propane (질소희석된 프로판 동축류 버너에서 부상화염에 대한 부력효과)

  • Kim, Jun-Hong;Shin, Moo-Kyung;Chung, Suk-Ho
    • 한국연소학회:학술대회논문집
    • /
    • 2001.06a
    • /
    • pp.9-16
    • /
    • 2001
  • When large size nozzle with low jet velocity is used, the buoyancy effect arises from the density difference among propane, air, and burnt gas. Flame characteristics in such buoyant jets have been investigated numerically to elucidate the effect of buoyancy on lifted flames. It has been demonstrated that the cold jet has circular cone shape since upwardly injected propane jet decelerates and forms stagnation region. In contrast to the cold flow, the reacting flow with a lifted flame has no stagnation region by the buoyancy force induced from the burnt gas. To further illustrate the buoyancy effect on lifted flames, the reacting flow with buoyancy is compared with non-buoyant reacting flow. Non-buoyant flame is stabilized at much lower height than the buoyant flame. At a certain range of fuel jet velocities and fuel dilutions. an oscillating flame is demonstrated numerically showing that the height of flame base and tip vary during one cycle of oscillation. Under the same condition. non-buoyant flame exhibits only steady lifted flames. This confirms the buoyancy effect on the mechanism of lifted flame oscillation.

  • PDF