• Title/Summary/Keyword: low total harmonic distortion (THD)

Search Result 82, Processing Time 0.027 seconds

Investigations of Multi-Carrier Pulse Width Modulation Schemes for Diode Free Neutral Point Clamped Multilevel Inverters

  • Chokkalingam, Bharatiraja;Bhaskar, Mahajan Sagar;Padmanaban, Sanjeevikumar;Ramachandaramurthy, Vigna K.;Iqbal, Atif
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.702-713
    • /
    • 2019
  • Multilevel Inverters (MLIs) are widely used in medium voltage applications due to their various advantages. In addition, there are numerous types of MLIs for such applications. However, the diode-less 3-level (3L) T-type Neutral Point Clamped (NPC) MLI is the most advantageous due to its low conduction losses and high potential efficiency. The power circuit of a 3L T-type NPC is derived by the conventional two level inverter by a slight modification. In order to explore the MLI performance for various Pulse Width Modulation (PWM) schemes, this paper examines the operation of a 3L (five level line to line) T-type NPC MLI for various types of Multi-Carriers Pulse Width Modulation (MCPWM) schemes. These PWM schemes are compared in terms of their voltage profile, total harmonic distortion (THD) and conduction losses. In addition, a 3L T-type NPC MLI is also compared with the conventional NPC in terms of number of switches, clamping diodes, main diodes and capacitors. Moreover, the capacitor-balancing problem is also investigated using the Neutral Point Fluctuation (NPF) method with all of the MCPWM schemes. A 1kW 3L T-type NPC MLI is simulated in MATLAB/Simulink and implemented experimentally and its performance is tested with a 1HP induction motor. The results indicate that the 3L T-type NPC MLI has better performance than conventional NPC MLIs.

A New DC Ripple-Voltage Suppression Scheme in Three Phase Buck Diode Rectifiers with Unity Power Factor (단위 역률을 갖는 3상 BUCK 다이오드 정류기에서의 새로운 DC 리플-전압 저감 기법)

  • Lee, Dong-Yun;Choy, Ick;Song, Joong-Ho;Choi, Ju-Yeop;Kim, Kwang-Bae;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.154-162
    • /
    • 2000
  • A technique to suppress the low frequency ripple voltage of the DC output ${\gamma}$oltage in three-phase buck d diode rectifiers is presented in this paper. The proposed pulse frequency modulation method is employed to r regulate the output voltage of the buck diode rectifiers and guarantee zero-current switching of the switch over the Vvide load range. The pulse frequency control method used in tIns paper shows generally good p performance such as low THD of the input line current and unity power factor. In addition, the pulse f freιluency method can be effectively used to suppress the low frequency voltage ripple appeared in the dc output voltage. The proposed technique illustrates its validity and effectiveness through the respective s simulations and experiments.

  • PDF

A Gate-Leakage Insensitive 0.7-V 233-nW ECG Amplifier using Non-Feedback PMOS Pseudo-Resistors in 0.13-μm N-well CMOS

  • Um, Ji-Yong;Sim, Jae-Yoon;Park, Hong-June
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.10 no.4
    • /
    • pp.309-315
    • /
    • 2010
  • A fully-differential low-voltage low-power electrocardiogram (ECG) amplifier by using the nonfeedback PMOS pseudo-resistors is proposed. It consists of two operational-transconductance amplifiers (OTA) in series (a preamplifier and a variable-gain amplifier). To make it insensitive to the gate leakage current of the OTA input transistor, the feedback pseudo-resistor of the conventional ECG amplifier is moved to input branch between the OP amp summing node and the DC reference voltage. Also, an OTA circuit with a Gm boosting block without reducing the output resistance (Ro) is proposed to maximize the OTA DC gain. The measurements shows the frequency bandwidth from 7 Hz to 480 Hz, the midband gain programmable from 48.7 dB to 59.5 dB, the total harmonic distortion (THD) less than 1.21% with a full voltage swing, and the power consumption of 233 nW in a 0.13 ${\mu}m$ CMOS process at the supply voltage of 0.7 V.

Optimized Low-Switching-Loss PWM and Neutral-Point Balance Control Strategy of Three-Level NPC Inverters

  • Xu, Shi-Zhou;Wang, Chun-Jie;Han, Tian-Cheng;Li, Xue-Ping;Zhu, Xiang-Yu
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.702-713
    • /
    • 2018
  • Power loss reduction and total harmonic distortion(THD) minimization are two important goals of improving three-level inverters. In this paper, an optimized pulse width modulation (PWM) strategy that can reduce switching losses and balance the neutral point with an optional THD of three-level neutral-point-clamped inverters is proposed. An analysis of the two-level discontinuous PWM (DPWM) strategy indicates that the optimal goal of the proposed PWM strategy is to reduce switching losses to a minimum without increasing the THD compared to that of traditional SVPWMs. Thus, the analysis of the two-level DPWM strategy is introduced. Through the rational allocation of the zero vector, only two-phase switching devices are active in each sector, and their switching losses can be reduced by one-third compared with those of traditional PWM strategies. A detailed analysis of the impact of small vectors, which correspond to different zero vectors, on the neutral-point potential is conducted, and a hysteresis control method is proposed to balance the neutral point. This method is simple, does not judge the direction of midpoint currents, and can adjust the switching times of devices and the fluctuation of the neutral-point potential by changing the hysteresis loop width. Simulation and experimental results prove the effectiveness and feasibility of the proposed strategy.

A Novel Topology Structure and Control Method of High-Voltage Converter for High-Input-Voltage Applications

  • Song, Chun-Wei;Zhao, Rong-Xiang;Zhang, Hao
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.2
    • /
    • pp.79-84
    • /
    • 2012
  • In this paper, a three-phase high-voltage converter (HVC), in which the main structure of each phase is composed of a cascaded PWM rectifier (CPR) and cascaded inverter (CI), is studied. A high-voltage grid is the input of the HVC. In order to ensure proper operation of the HVC, the control method should achieve output voltage sharing (OVS) among the rectifiers in the CPR, OVS among the inverters in the CI, and high power factor. Master-slave direct-current control (MDCC) is used to control the CPR. The ability of the control system to prevent interference is strong when using MDCC. The CI is controlled by three-loop control, which is composed of an outer common-output-voltage loop, inner current loops and voltage sharing loops. Simulation results show low total harmonic distortion (THD) in the HVC input currents and good OVS in both the CPR and CI.

A Novel Three Phase Series-Parallel Resonant Converter Fed DC-Drive System

  • Daigavane, Manoj;Suryawanshi, Hiralal;Khan, Jawed
    • Journal of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.222-232
    • /
    • 2007
  • This paper presents the application of a single phase AC-to-DC converter using a three-phase series parallel (SPRC) resonant converter to variable speed dc-drive. The improved power quality converter gives the input power factor unity over a wide speed range, reduces the total harmonic distortion (THD) of ac input supply current, and makes very low ripples in the armature current and voltage waveform. This soft-switching converter not only possesses the advantages of achieving high switching frequencies with practically zero switching losses but also provides full ranges of voltage conversion and load variation. The proposed drive system is the most appropriate solution to preserve the present separately excited de motors in industry compared with the use of variable frequency ac drive technology. The simulation and experimental results are presented for variable load torque conditions. The variable frequency control scheme is implemented using a DSP- TMS320LF2402. This control reduces the switching losses and current ripples, eliminates the EMI and improves the efficiency of the drive system. Experimental results confirm the consistency of the proposed approach.

An improvement of cycloconverter output using phase shifting filter (상천이 필터를 이용한 싸이클로컨버터 출력의 개선)

  • Kim, Jong-Su;Seo, Dong-Hoan;Kim, Jeong-Woo;Kim, Sung-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.1
    • /
    • pp.121-126
    • /
    • 2013
  • Cycloconverter used as a power conversion device in the speed and torque control system of AC machines has the advantage of a simple control and a large torque at low speed. In addition, because a rectifier, a DC link, and an inverter are not installed, this system is simple and suitable for large power system. If a power conversion device, which is currently used as a propulsion motor of large vessel, is changed into cycloconverter, the system is simplified and then the installation costs can be significantly reduced. However, conventional cycloconverter has the increased harmonics because the power loss is large and the waveform of output voltage is distorted, due to the high-speed switching of power semiconductor devices. In order to improve these shortcomings, this paper describes a phase shifting filter which is composed of two inputs with different phases in the primary side and one output in the secondary one. As the voltage waveforms with two different phases are added and transformed into the secondary side, these outputs are close to sinusoidal waves. Thereby the voltage waveforms, which are applied to the propulsion motors, are improved and total harmonic distortions (THDs) are significantly reduced.

Design of 3V CMOS Continuous-Time Filter Using Fully-Balanced Current Integrator (완전평형 전류 적분기를 이용한 3V CMOS 연속시간 필터 설계)

  • An, Jeong-Cheol;Yu, Yeong-Gyu;Choe, Seok-U;Kim, Dong-Yong;Yun, Chang-Hun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.37 no.4
    • /
    • pp.28-34
    • /
    • 2000
  • In this paper, a continuous-time filter for low voltage and high frequency applications using fully-balanced current integrators is presented. As the balanced structure of integrator circuits, the designed filter has improved noise characteristics and wide dynamic range since even-order harmonics are cancelled and the input signal range is doubled. Using complementary current mirrors, bias circuits are simplified and the cutoff frequency of filters can be controlled easily by a single DC bias current. As a design example, the 3rd-order lowpass Butterworth filter with a leapfrog realization is designed. The designed fully-balanced current-mode filter is simulated and examined by SPICE using 0.65${\mu}{\textrm}{m}$ CMOS n-well process parameters. The simulation results show 50MHz cutoff frequency, 69㏈ dynamic range with 1% total harmonic distortion(THD), and 4㎽ power dissipation with a 3V supply voltage.

  • PDF

LED Driver with TRIAC Dimming Control by Variable Switched Capacitance for Power Regulation

  • Lee, Eun-Soo;Sohn, Yeung-Hoon;Nguyen, Duy Tan;Cheon, Jun-Pil;Rim, Chun-Taek
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.555-566
    • /
    • 2015
  • A TRIAC dimming LED driver that can control the brightness of LED arrays for a wide range of source voltage variations is proposed in this paper. Unlike conventional PWM LED drivers, the proposed LED driver adopts a TRIAC switch, which inherently guarantees zero current switching and has been proven to be quite reliable over its long lifetime. Unlike previous TRIAC type LED drivers, the proposed LED driver is composed of an LC input filter and a variable switched capacitance, which is modulated by the TRIAC turn-on timing. Thus, the LED power regulation and dimming control, which are done by a volume resistor in the same way as the conventional TRIAC dimmers, can be simultaneously performed by the TRIAC control circuit. Because the proposed LED driver has high efficiency and a long lifetime with a high power factor (PF) and low total harmonic distortion (THD) characteristics, it is quite adequate for industrial lighting applications such as streets, factories, parking garages, and emergency stairs. A simple step-down capacitive power supply circuit composed of passive components only is also proposed, which is quite useful for providing DC power from an AC source without a bulky and heavy transformer. A prototype 60 W LED driver was implemented by the proposed design procedure and verified by simulation and experimental results, where the efficiency, PF, and THD are 92%, 0.94, and 6.3%, respectively. The LED power variation is well mitigated to below ${\pm}2%$ for 190 V < $V_s$ < 250 V by using the proposed simple control circuit.

A Comparative Study on Power System Harmonics for Offshore Plants (해양플랜트 전력시스템의 고조파 비교분석에 관한 연구)

  • Kim, Deok-Ki;Lee, Won-Ju;Kim, Jong-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.7
    • /
    • pp.900-905
    • /
    • 2016
  • The field of power system harmonics has been receiving a great deal of attention recently. This is primarily due to the fact that non-linear (or harmonic-producing) loads comprise an ever-increasing portion of what is handled at a typical industrial plant. The incidence rate of harmonic-related problems is low, but awareness of harmonic issues can still help increase offshore power plant system reliability. On the rare occasion that harmonics become a problem, this is either due to the magnitude of harmonics produced or power system resonance. This harmonic study used an electrical configuration for the offloading scenario of a Floating LNG (FLNG) unit, considering power load. This electrical network configuration is visible in the electrical network load flow study part of the project. This study has been carried out to evaluate the performance of an electric power system, focusing on the harmonic efficiency of an electrically driven motor system to ensure offshore plant safety. In addition, the design part of this study analyzed the electric power system of an FLNG unit to improve the safety of operation and maintenance.