• Title/Summary/Keyword: low resolution

Search Result 2,619, Processing Time 0.337 seconds

Calculation of Soil Moisture and Evapotranspiration of KLDAS applying Ground-Observed Meteorological Data (지상관측 기상자료를 적용한 KLDAS(Korea Land Data Assimilation System)의 토양수분·증발산량 산출)

  • Park, Gwangha;Kye, Changwoo;Lee, Kyungtae;Yu, Wansik;Hwang, Eui-ho;Kang, Dohyuk
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_1
    • /
    • pp.1611-1623
    • /
    • 2021
  • Thisstudy demonstratessoil moisture and evapotranspiration performance using Korea Land Data Assimilation System (KLDAS) under Korea Land Information System (KLIS). Spin-up was repeated 8 times in 2018. In addition, low-resolution and high-resolution meteorological data were generated using meteorological data observed by Korea Meteorological Administration (KMA), Rural Development Administration (RDA), Korea Rural Community Corporation (KRC), Korea Hydro & Nuclear Power Co.,Ltd. (KHNP), Korea Water Resources Corporation (K-water), and Ministry of Environment (ME), and applied to KLDAS. And, to confirm the degree of accuracy improvement of Korea Low spatial resolution (hereafter, K-Low; 0.125°) and Korea High spatial resolution (hereafter, K-High; 0.01°), soil moisture and evapotranspiration to which Modern-Era Retrospective analysis for Research and Applications, version 2 (MERRA-2) and ASOS-Spatial (ASOS-S) used in the previous study were applied were evaluated together. As a result, optimization of the initial boundary condition requires 2 time (58 point), 3 time (6 point), and 6 time (3 point) spin-up for soil moisture. In the case of evapotranspiration, 1 time (58 point) and 2 time (58 point) spin-ups are required. In the case of soil moisture to which MERRA-2, ASOS-S, K-Low, and K-High were applied, the mean of R2 were 0.615, 0.601, 0.594, and 0.664, respectively, and in the case of evapotranspiration, the mean of R2 were 0.531, 0.495, 0.656, and 0.677, respectively, indicating the accuracy of K-High was rated as the highest. The accuracy of KLDAS can be improved by securing a large number of ground observation data through the results of this study and generating high-resolution grid-type meteorological data. However, if the meteorological condition at each point is not sufficiently taken into account when converting the point data into a grid, the accuracy is rather lowered. For a further study, it is expected that higher quality data can be produced by generating and applying grid-type meteorological data using the parameter setting of IDW or other interpolation techniques.

Metrics for Low-Light Image Quality Assessment

  • Sangmin Kim
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.8
    • /
    • pp.11-19
    • /
    • 2023
  • In this paper, it is confirmed that the metrics used to evaluate image quality can be applied to low-light images. Due to the nature of low-illumination images, factors related to light create various noise patterns, and the smaller the amount of light, the more severe the noise. Therefore, in situations where it is difficult to obtain a clean image without noise, the quality of a low-illuminance image from which noise has been removed is often judged by the human eye. In this paper, noise in low-illuminance images for which ground truth cannot be obtained is removed using Noise2Noise, and spatial resolution and radial resolution are evaluated using ISO 12233 charts and colorchecker as metrics such as MTF and SNR. It can be shown that the quality of the low-illuminance image, which has been evaluated mainly for qualitative evaluation, can also be evaluated quantitatively.

2-D OCT image implementation using low coherence SLD (Low coherence 특성의 SLD를 이용한 2차원 OCT 영상 구현)

  • 정태호;박양하;오상기;김용평
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.290-291
    • /
    • 2003
  • Optical Coherence Tomography is a new medical dianostic imaging technology which can perform micron resolution cross-sectional or tomograpic imaging in biological tissue. In this paper, we analyze OCT system. And we have 2-dimensional OCT image implementation using low coherence SLD.

  • PDF

High Resolution Video Synthesis with a Hybrid Camera (하이브리드 카메라를 이용한 고해상도 비디오 합성)

  • Kim, Jong-Won;Kyung, Min-Ho
    • Journal of the Korea Computer Graphics Society
    • /
    • v.13 no.4
    • /
    • pp.7-12
    • /
    • 2007
  • With the advent of digital cinema, more and more movies are digitally produced, distributed via digital medium such as hard drives and network, and finally projected using a digital projector. However, digital cameras capable of shotting at 2K or higher resolution for digital cinema are still very expensive and bulky, which impedes rapid transition to digital production. As a low-cost solution for acquiring high resolution digital videos, we propose a hybrid camera consisting of a low-resolution CCD for capturing videos and a high-resolution CCD for capturing still images at regular intervals. From the output of the hybrid camera, we can synthesize high-resolution videos by software as follows: for each frame, 1. find pixel correspondences from the current frame to the previous and subsequent keyframes associated with high resolution still images, 2. synthesize a high-resolution image for the current frame by copying the image blocks associated with the corresponding pixels from the high-resolution keyframe images, and 3. complete the synthesis by filling holes in the synthesized image. This framework can be extended to making NPR video effects and capturing HDR videos.

  • PDF

A Survey of Weather Forecasting Software and Installation of Low Resolution of the GloSea6 Software (기상예측시스템 소프트웨어 조사 및 GloSea6 소프트웨어 저해상도 설치방법 구현)

  • Chung, Sung-Wook;Lee, Chang-Hyun;Jeong, Dong-Min;Yeom, Gi-Hun
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.5
    • /
    • pp.349-361
    • /
    • 2021
  • With the development of technology and the advancement of weather forecasting models and prediction methods, higher performance weather forecasting software has been developed, and more precise and accurate weather forecasting is possible by performing software using supercomputers. In this paper, the weather forecast model used by six major countries is investigated and its characteristics are analyzed, and the Korea Meteorological Administration currently uses it in collaboration with the UK Meteorological Administration since 2012 and explains the GloSea However, the existing GloSea was conducted only on the Meteorological Administration supercomputer, making it difficult for various researchers to perform detailed research by specialized field. Therefore, this paper aims to establish a standard experimental environment in which the low-resolution version based on GloSea6 currently used in Korea can be used in local systems and test it to present the localization of low-resolution GloSea6 that can be performed in the laboratory environment. In other words, in this paper, the local portability of low-resolution Globe6 is verified by establishing a basic architecture consisting of a user terminal-calculation server-repository server and performing execution tests of the software.

Enhancing CT Image Quality Using Conditional Generative Adversarial Networks for Applying Post-mortem Computed Tomography in Forensic Pathology: A Phantom Study (사후전산화단층촬영의 법의병리학 분야 활용을 위한 조건부 적대적 생성 신경망을 이용한 CT 영상의 해상도 개선: 팬텀 연구)

  • Yebin Yoon;Jinhaeng Heo;Yeji Kim;Hyejin Jo;Yongsu Yoon
    • Journal of radiological science and technology
    • /
    • v.46 no.4
    • /
    • pp.315-323
    • /
    • 2023
  • Post-mortem computed tomography (PMCT) is commonly employed in the field of forensic pathology. PMCT was mainly performed using a whole-body scan with a wide field of view (FOV), which lead to a decrease in spatial resolution due to the increased pixel size. This study aims to evaluate the potential for developing a super-resolution model based on conditional generative adversarial networks (CGAN) to enhance the image quality of CT. 1761 low-resolution images were obtained using a whole-body scan with a wide FOV of the head phantom, and 341 high-resolution images were obtained using the appropriate FOV for the head phantom. Of the 150 paired images in the total dataset, which were divided into training set (96 paired images) and validation set (54 paired images). Data augmentation was perform to improve the effectiveness of training by implementing rotations and flips. To evaluate the performance of the proposed model, we used the Peak Signal-to-Noise Ratio (PSNR), Structural Similarity Index Measure (SSIM) and Deep Image Structure and Texture Similarity (DISTS). Obtained the PSNR, SSIM, and DISTS values of the entire image and the Medial orbital wall, the zygomatic arch, and the temporal bone, where fractures often occur during head trauma. The proposed method demonstrated improvements in values of PSNR by 13.14%, SSIM by 13.10% and DISTS by 45.45% when compared to low-resolution images. The image quality of the three areas where fractures commonly occur during head trauma has also improved compared to low-resolution images.

A New Algorithm to Estimate Urine Volume from 3D Ultrasound Bladder Images (3D 초음파 영상에서 방광 내 잔뇨량 추정을 위한 새로운 알고리즘)

  • Cho, Tae Sik;Lee, Soo Yeol;Cho, Min Hyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.31-38
    • /
    • 2016
  • For the patients with bladder dysfunction, measurement of urine volume inside the bladder is very critical to avoid bladder failure. In measuring urine volume inside a bladder, low-resolution 3D ultrasound images are widely used. However, urine volume estimation from 3D ultrasound images is prone to big errors and inconsistency because of low spatial resolution and low signal-to-noise ratio of ultrasound images. We developed a new robust volume estimation algorithm which is not computationally expensive. We tested the algorithm on a lab-built ultrasound bladder phantom and volunteers. The average error rate of the human bladder volume estimation was 5.9% which was better than the commercial machine.

Low Cost Rotor Fault Detection System for Inverter Driven Induction Motor

  • Kim, Nam-Hun;Choi, Chang-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.4
    • /
    • pp.500-504
    • /
    • 2007
  • In this paper, the induction motor rotor fault diagnosis system using current signals, which are measured using axis-transformation method, and speed, which is estimated using current information, are presented. In inverter-fed motor drives unlike line-driven motor drives the stator currents have numerous harmonics components and therefore fault diagnosis using stator currents is very difficult. The current and speed signal for rotor fault diagnosis needs to be precise. Also, high resolution information, which means the diagnosis system, demands additional hardware such as low pass filter, high resolution ADC, encoder and etc. Therefore, the proposed axis-transformation and speed estimation method are expected to contribute to low cost fault diagnosis systems in inverter-fed motor drives without the need for an encoder and any additional hardware. In order to confirm validity of the developed algorithms, various experiments for rotor faults are tested and the line current spectrum of each faulty situation using Park transformation and speed estimation method are compared with the results obtained from fast Fourier transforms.

ACCELEROMETER SELECTION CONSIDERATIONS Charge and Integral Electronic Piezo Electric

  • Lally, Jim
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.1047-1051
    • /
    • 2004
  • Charge amplifier systems benefit from the very wide dynamic range of PE accelerometers by offering flexibility in adjusting the electrical output characteristics such as sensitivity and range. They are well suited for operation at high temperatures. Modern charge systems feature improved low noise operation, simplified digital controls, and dual mode operation for operation with charge or IEPE voltage mode sensors. high impedance circuitry is not well suited for operation in adverse field or factory environments. The resolution of a PE accelerometer may not be specified or known since noise is a system consideration determined by cable length and amplifier gain. IEPE accelerometrs operate from a constant current power source, provide a high-voltage, low-impedance, fixed mV/g output. They operate through long, ordinary, coaxial cable in adverse environments without degradation of signal quality. They have limited high temperature range. IEPE sensors are simple to operate. Both resolution and operating range are defined specifications. Cost perchannel is lower compared to PE systems since low-noise cable and charge amplifiers are not required.

  • PDF

Low-Power. High Slew-Rate OP-AMP for Large Size, High Resolution TFT-LCDs

  • Kim, Seong-Joong;Sung, Yoo-Chang;Lim, Byong-Chan;Kwon, Oh-Kyong;Chang, Kye-Eon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.530-532
    • /
    • 2002
  • We have developed a low-power, high slew-rate OP-AMP for large size and high resolution TFT-LCDs which have 8${\mu}$A quiescent current with settling time less than 6${\mu}$sec. The proposed OP-AMP contains newly developed the driving circuit of class-AB output stage which can achieve a low quiescent current less than 8${\mu}$A and a slew-rate higher than 3.14V/${\mu}$sec.

  • PDF