• Title/Summary/Keyword: low order modulation

Search Result 186, Processing Time 0.031 seconds

Mobile Hotspot Network System for High-Speed Railway Communications Using Millimeter Waves

  • Choi, Sung-Woo;Chung, Heesang;Kim, Junhyeong;Ahn, Jaemin;Kim, Ilgyu
    • ETRI Journal
    • /
    • v.38 no.6
    • /
    • pp.1052-1063
    • /
    • 2016
  • We propose a millimeter wave (MMW)-based mobile hotspot network (MHN) system for application in high-speed railways that is capable of supporting a peak backhaul link throughput of 1 Gbps per train at 400 km/h. The MHN system can be implemented in subways and high-speed trains to support passengers with smart devices and provide access to the Internet. The proposed system can overcome the inherent high path loss in MMW through system designs and high antenna gains. We present a simulation of the system performance that shows that a fixed beamforming strategy can provide high signal-to-interference-plus-noise-ratio similar to those of an adaptive beamforming strategy, with the exception of 15% of the train path in which the network can use link adaptation with low-order modulation formats or trigger a handover to maintain the connection. We also demonstrate the feasibility of the MHN system using a test bed deployed in Seoul subway line 8. The backhaul link throughput varies instantaneously between 200 Mbps and 500 Mbps depending on the SNR variations while the train is running. During the field trial, the smartphones used could make connections through offloading.

A Study on Characteristics of Injected Fuel Pressure Waves of a Solenoid Type Diesel Common Rail Injector with Controlling Current Wave for Driving the Injector (솔레노이드 타입 디젤 커먼레일 인젝터 구동을 위한 전류 파형 변화에 따른 분사 연료 압력파 특성)

  • Kim, Kil Tae;Lee, Choong Hoon
    • Journal of ILASS-Korea
    • /
    • v.21 no.3
    • /
    • pp.155-161
    • /
    • 2016
  • Injected fuel pressure waves of a common rail injector with various current profiles supplied to the injecor were measured using Bosch method. In order to drive the common rail injector, the current in the solenoid should be controlled using what is known as a peak and hold pattern, which consists of a high current level with a short time duration (peak) in the first step and a low current level with a long time duration (hold) in the subsequent step. The current profile can be shaped by swithcing an injector driving power source with the peak and hold waves. The capture, compare and PWM (CCP) pin in the microprocessor was used to generate the combined peak and hold waves. The PWM square wave generated from the CCP pin has a duty ratio of 100% for the peak current and 10% or 30% for the hold pattern. Five patterns of the current profile were generated by combining the peak and hold wave. The common rail pressure is controlled at 75, 100, and 130 MPa. As the fuel rail pressure increases, the variations of the measured fuel injection pressure wave according to the current profiles decrease.

A Study on the Advanced Technology of Solid Rocket Propulsion (고체 추진기관 선진국 기술 동향에 관한 연구)

  • Kim, Hyung-Won;Park, Chong-Seung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.221-224
    • /
    • 2010
  • Recently, due to the enormous cost for sending a satellite into an orbit, small and more reliable satellites have been more demanded. An introduction of new binders(HTPB, GAP) and new oxidizers made great improvements of the large thrust modulation. In order to make cost reduction, one prefers to the low melting temperature thermoplastic propellant reforming the manufacturing process dramatically. Solid propellant rockets have been had a problem of the injection accuracy into orbit, but PBS(Post Boost Stage) using a liquid mono-propellant improves the injection accuracy. This paper also gives the direction of the advanced nozzle materials and the motor case.

  • PDF

Sliding Mode Control Based DTC of Sensorless Parallel-Connected Two Five-Phase PMSM Drive System

  • Kamel, Tounsi;Abdelkader, Djahbar;Said, Barkat;Al-Hitmi, M.;Iqbal, Atif
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1185-1201
    • /
    • 2018
  • This paper presents a sensorless direct torque control (DTC) combined with sliding mode approach (SM) and space vector modulation (SVM) to achieve mainly a high performance and reduce torque and flux ripples of a parallel-connected two five-phase permanent magnet synchronous machine (PMSM) drive system. In order to increase the proposed drive robustness and decrease its complexity and cost, the rotor speeds, rotor positions, fluxes as well as torques are estimated by using a sliding mode observer (SMO) scheme. The effectiveness of the proposed sliding mode observer in conjunction with the sliding mode control based DTC is confirmed through the application of different load torques for wide speed range operation. Comparison between sliding mode control and proportional integral (PI) control based DTC of the proposed two-motor drive is provided. The obtained speeds, torques and fluxes responses follow their references; even in low and reverse speed operations, load torques changes, and machines parameters variations. Simulation results confirm also that, the ripples of the torques and fluxes are reduced more than 3.33% and 16.66 %, respectively, and the speed overshoots and speed drops are reduced about 99.85% and 92.24%, respectively.

Design of LUT-Based Decimation Filter for Continuous-Time PWM ADC (연속-시간 펄스-폭-변조 ADC를 위한 LUT 기반 데시메이션 필터 설계)

  • Shim, Jae Hoon
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.461-468
    • /
    • 2019
  • A continuous-time Delta-Sigma ADC has various benefits; it does not require an explicit anti-aliasing filter, and it is able to handle wider-band signals with less power consumption in comparison with a discrete-time Delta-Sigma ADC. However, it inherently needs to sample the signal with a high-speed clock, necessitating a complex decimation filter that operates at high speed in order to convert the modulator output to a low-rate high-resolution digital signals without causing aliasing. This paper proposes a continuous-time Delta-Sigma ADC architecture that employs pulse-width modulation and shows that the proposed architecture lends itself to a simpler implementation of the decimation filter using a lookup table.

Heart Rate Variability in Patients with Coronary Artery Disease (관상동맥질환 환자의 심박동변이도)

  • Kim Wuon-Shik;Bae Jang-Ho;Choi Hyoung-Min;Lee Sang-Tae
    • Science of Emotion and Sensibility
    • /
    • v.8 no.2
    • /
    • pp.95-101
    • /
    • 2005
  • This study is based on previous information regarding reduced cardiac vagal activity in patients with coronary artery disease(CAD), on reduced variance(SDNN : standard deviation of all normal RR intervals), low-frequency power(LF), and the complexity of heart rate variability(HRV) in patients with chronic heart failure(CHF), and on the normalized high-frequency power of HRV is the highest in the right lateral decubitus position among 3 recumbent postures in patients with CAD, However, nothing is known about the nonlinear dynamics of HRV for the 3 recumbent postures in patients with CAD. To investigate the linear and non-linear characteristics of HRV in patients with CAD, 29 patients as CAD group and 23 patients as control group were studied. Electrocardiogram(ECG) with lead II channel was measured on these patients for 3 recumbent postures in random order. The HRV from ECG was analyzed with linear method(for time and frequency domains) and nonlinear method. The lower the high-frequency power in normalized unit(nHF) in the supine or left lateral decubitous position, the higher the increase in nHF when the position was changed from supine or left lateral decubitous to right lateral decubitous. Among the 3 recumbent postures in patients with severe CAD, the right lateral decubitus position was observed to induce the highest vagal modulation, the lowest sympathetic modulation, and the highest complexity of human physiology system.

  • PDF

A Design and Implementation of Circuit for Efficient Power LED Dimming Control (효율적인 고출력 LED 디밍 제어를 위한 회로 설계 및 구현)

  • Kim, Doo-Hyun;Choi, Jae-Ho;Cho, Beom-Joon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.9
    • /
    • pp.2280-2288
    • /
    • 2014
  • The conventional dimming control methods of LED (Light-emitting dioades) include Analog, PWM (Pulse Width Modulation), and FM (Frequency Modulation) Control. Analog dimming is controlled by adjusting forward current of Power LED. Although Analog dimming is possible to control linearly the brightness levels on a whole range (0%~100%), it comes into existence a variation of wavelength by changing the Power LED's forward current. PWM dimming has achieved by varying in duty of full current flowing to the Power LED. Generally, PWM dimming doesn't make variation of wavelength but have difficulty with adjusting the linear brightness level between 0% and 10%. FM dimming method is on the same wavelength as PWM dimming, however, it has problem of flickering at low level of dimming. This paper propose a efficient dimming control method of Power LED in order to overcome the disadvantages of the above mentioned methods. We apply to Analog method in low level of dimming control and use PWM method in dimming range from 10% to 100%. For the experiment, we design and implement a circuit and test the proposed method. Consequently, we can control the linear brightness of Power LED across the whole range and get the constant wave at different dimming level. The experimental results show the benefits of the proposed method.

Selection of mAs with Using Table Strap in Computed Tomography Scan (전산화단층촬영 시 환자 고정 밴드를 이용한 선량의 선택)

  • Lee, Young-Hyen;An, Hyeong-Theck
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.63-69
    • /
    • 2011
  • Table strapis patient fixture for securing the patient movements and falls. if it designed to measure the abdominal circumference and used as an indicator of dose selection at CT scan. it will prevent the overexposure of dose without degradation of image quality and efficiently manage dose of each type of body to technician to deal with CT. First, in order to compare the dose used in CT image and qualitative characteristics. reference image is obtained by examining the abdominal phantom in same conditions with the hospital 120 kVp, 200 mAs, D-Dom (Dynamic Dose Of Modulation). SNR, PSNR, RMSE, MAE, CTDIvol of CT images are compared with reference image. for comparing with reference image, the image that Umbilicus level image of Abdomen CT is stored in the PACS were used. For comparison, the top 12 o'clock portion of the air drawn from the same ROI was measured. CTDIvol, mAs, etc. In order to analyze the characteristics of the image, by measuring the length of the umbilicus circumference, pattern of the dose was analyzed. by using the analyzed perimeter and dose information, To be identified visually, fixed band that scale marked were produced. Use them, If the length of circumference of less than 60 cm 100 mAs, Case of 61~80 cm 120 mAs, Case of 80~100 cm 150 mAs, more than 100 cm 200 mAs, dose selection based on the perimeter, the image was applied. by compare analyzed with the Reference Image, image quality was assessed. by compare with existing tests that equally 200 mAs applied, How much was confirmed that the dose reduction. 1. Depending on the Abdominal circumference, the average PSNR(dB) of the image that differently dose applied was 45.794. 2. Comparing with existing test. the dose of scan that adjusted the mAs depending on the circumference was decreased about 40%. SNR and PSNR of the image that obtained by adjusting the standard mAs based on dose modulation were not much different. Therefore, By choosing a low mAs. dose reduction can be obtained. and the dose selection method that measured Abdominal circumference using a fixed band can protect the overexposure and uniformly apply dose of each type of body to technician to deal with CT.

  • PDF

Identification of Motor Parameters and Improvement of Voltage Error for Improvement of Back-emf Estimation in Sensorless Control of Low Speed Operation (저속 센서리스 제어의 역기전력 추정 성능 향상을 위한 모터 파라미터 추정과 전압 오차의 개선)

  • Kim, Kyung-Hoon;Yun, Chul;Cho, Nae-Soo;Jang, Min-Ho;Kwon, Woo-Hyen
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.5
    • /
    • pp.635-643
    • /
    • 2018
  • This paper propose a method to identify the motor parameters and improve input voltage error which affect the low speed position error of the back-emf(back electromotive force) based sensorless algorithm and to secure the operation reliability and stability even in the case where the load fluctuation is severe and the start and low speed operation frequently occurs. In the model-based observer used in this paper, stator resistance, inductance, and input voltage are particularly influential factors on low speed performance. Stator resistance can cause resistance value fluctuation which may occur in mass production process, and fluctuation of resistance value due to heat generated during operation. The inductance is influenced by the fluctuation due to the manufacturing dispersion and at a low speed where the change of the current is severe. In order to find stator resistance and inductance which have different initial values and fluctuate during operation and have a large influence on sensorless performance at low speed, they are commonly measured through 2-point calculation method by 2-step align current injection. The effect of voltage error is minimized by offsetting the voltage error. In addition, when the command voltage is used, it is difficult to estimate the back-emf due to the relatively large distortion voltage due to the dead time and the voltage drop of the power device. In this paper, we propose a simple circuit and method to detect the voltage by measuring the PWM(Pulse Width Modulation) pulse width and compensate the voltage drop of the power device with the table, thereby minimizing the position error due to the exact estimation of the back-emf at low speed. The suitability of the proposed algorithm is verified through experiment.

High-Frequency Circuit Modeling of the Conducted-Emission from the LDC System of a Electric Vehicle (전기자동차 LDC 시스템의 전도 방출에 관한 고주파 모델링 연구)

  • Jung, Kibum;Jo, Byeong-Chan;Chung, Yeon-Choon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.8
    • /
    • pp.798-804
    • /
    • 2013
  • In this paper, conducted emission from the LDC(Low-Side DC/DC Converter) of a HEV/EV was analyzed using high-frequency circuit modeling in system-level approach. The conducted emission by PWM process(100 kHz; Switching Frequency) can cause RFI(Radio-Frequency Interference) problems in the AM/FM frequency range. In order to mitigate this conducted emission, a high-frequency equivalent circuit model is proposed by analyzing the fundamental circuits, parasitic components in their parts and connections and non-linear characteristics of MOSFETs, high-power capacitors, inverters, motors, high-power cables, and bus bars which are composed of the LDC. Using these circuit models, results of both simulation and measurement were compared and similarities between them were verified. We are looking forward that this approach can be effectively used in the EMC design of HEV/EV.