• Title/Summary/Keyword: low order harmonic

Search Result 200, Processing Time 0.027 seconds

ANALYSIS OF THE EFFECT OF UTI-UTC TO HIGH PRECISION ORBIT PROPAGATION

  • Shin, Dong-Seok;Kwak, Sung-Hee;Kim, Tag-Gon
    • Journal of Astronomy and Space Sciences
    • /
    • v.16 no.2
    • /
    • pp.159-166
    • /
    • 1999
  • As the spatial resolution of remote sensing satellites becomes higher, very accurate determination of the position of a LEO (Low Earth Orbit) satellite is demanding more than ever. Non-symmetric Earth gravity is the major perturbation force to LEO satellites. Since the orbit propagation is performed in the celestial frame while Earth gravity is defined in the terrestrial frame, it is required to convert the coordinates of the satellite from one to the other accurately. Unless the coordinate conversion between the two frames is performed accurately the orbit propagation calculates incorrect Earth gravitational force at a specific time instant, and hence, causes errors in orbit prediction. The coordinate conversion between the two frames involves precession, nutation, Earth rotation and polar motion. Among these factors, unpredictability and uncertainty of Earth rotation, called UTI-UTC, is the largest error source. In this paper, the effect of UTI-UTC on the accuracy of the LEO propagation is introduced, tested and analzed. Considering the maximum unpredictability of UTI-UTC, 0.9 seconds, the meaningful order of non-spherical Earth harmonic functions is derived.

  • PDF

A New Harmonics Reducing Type High Factor Single-Phase Rectifier Circuit (새로운 고조파 저감형 고역율 단상정류 회로)

  • Kim, Chil-Yong;Mun, Sang-Pil;Cho, Man-Chul;Shu, Ki-Young;Kwon, Soon-Kurl
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.468-472
    • /
    • 2007
  • For small capacity rectifier circuits such as these for consumer electronics and appliances, capacitor input type rectifier circuits are generally used. Consequently, various harmonics generated within the power system become a serious problem. Various studies of this effect have been presented previously. The absence of switching devices makes systems more tolerant to over-load, and brings low radio noise benefits. We propose a power factor correction scheme using a LC resonant in commercial frequency without switching devices. In this method, It makes a sinusoidal wave by widening conduction period using the current resonance in commercial frequency, Hence, the harmonic characteristics can be significantly improved, where the lower order harmonics, such as the fifth and seventh orders are much reduced. The result are confirmed by the theoretical and expermental implementations

  • PDF

A Study on the Rejection of A Output Leakage Current of Single Phase Induction Motor Driven a Inverter (인버터로 구동되는 단상 유도전동기의 출력 누설전류 억제 대책에 관한 연구)

  • 박찬근;박정환;최승현;이성근
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.553-557
    • /
    • 2000
  • This paper proposes the method to reduce output leakage current in single phase induction motor driven a PWM inverter. A proposed method applies to a new PWM switching algorism to reduce low-order harmonic in an inverter system with a feedback circuit of leakage current. Simulation is done to confirm a validity of method Proposed.

  • PDF

A new real-time optimal direct digital PWM technique (실시간 최적 제어가 가능한 새로운 직접 디지탈 PWM기술)

  • Hwang, Jae-Ho;Choi, Ik;Kwon, Soon-Hak;Park, Gwi-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1265-1268
    • /
    • 1996
  • This paper describes a new pulse width modulation (PWM) scheme suitable for microprocessor-based PWM inverters. Optimal switching patterns minimizing the performance index corresponding to the distortion factor are decided in real time by numerical calculation using the microprocessor-implemented control system. This PWM method is compared with conventional methods, such as the natural PWM and the direct PWM. Harmonic analysis using digital simulations shows that the proposed PWM scheme has much less low-order harmonics than the other methods. The validity of this method is verified in experiments using a microprocessor-based control system, where a 16-bit single-chip microcontroller, Intel 80c196kc is used.

  • PDF

A Novel Control Strategy for Input-Parallel-Output-Series Inverter System

  • Song, Chun-Wei;Zhao, Rong-Xiang;Lin, Wang-Qing;Zeng, Zheng
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.2
    • /
    • pp.85-90
    • /
    • 2012
  • This paper presents a topology structure and control method for an input-parallel-output-series(IPOS) inverter system which is suitable for high input current, high output voltage, and high power applications. In order to ensure the normal operation of the IPOS inverter system, the control method should achieve input current sharing(ICS) and output voltage sharing(OVS) among constituent modules. Through the analysis in this paper, ICS is automatically achieved as long as OVS is controlled. The IPOS inverter system is controlled by a three-loop control system which is composed of an outer common-output voltage loop, inner current loops and voltage sharing loops. Simulation results show that this control strategy can achieve low total harmonic distortion(THD) in the system output voltage, fast dynamic response, and good output voltage sharing performance.

A SVPWM for the Small Fluctuation of Neutral Point Current in Three-level Inverter (중성점 전류 리플을 고려한 3-레벨 인버터의 공간 벡터 펄스폭 변조 기법)

  • 김래영;이요한;현동석
    • Proceedings of the KIPE Conference
    • /
    • 1998.11a
    • /
    • pp.33-37
    • /
    • 1998
  • For the high power variable speed applications, the DCTLI(diode clamped three-level inverter) have been widely used. This paper describes the analysis of the neutral point current of the DCTLI and the improved space vector-based PWM strategy considering the switching frequency of power devices, that minimizes the fluctuation of the neutral point current in spite of high modulation index region and low power factor. It contributes to decrease the capacitance of dc-link capacitor bank and to increase the neutral point voltage controllable region. Especially, even if second (or even) order harmonic is induced in load current (at this situation, is was investigated that the general control method can not suppress the neutral point voltage variation), this PWM can provide effective control method to suppress the neutral point voltage variation. Various simulation results by means of Matlab/Simulation are presented to verify the proposed PWM.

  • PDF

Performance Enhancement of Sensorless Drive for Brushless DC Motors using Digital Filter (디지틀 필터를 이용한 브러시리스 직류 전동기용 센서리스 드라이브의 성능 향상에 관한 연구)

  • Yeo, Hyeong-Gi;Kim, Tae-Hyeong;Park, Jeong-Bae;Lee, Gwang-Un;Yu, Ji-Yun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.2
    • /
    • pp.63-68
    • /
    • 1999
  • This pper describes a digital sensorless drive of permanent magnet brushless DC motors. In order to detect in real time the rotor positions of which Emf becomes zero, terminal voltages are sampled during PWM duty cycle. This method generates detection error in indirect sensed position, which is the harmonic component of PWM frequency. In this paper, the drive adopted Butterworth low pass filter for rejection of the sensing error and for accurate estimation of commutation time. Analytical design process of the digital filter is proposed and the experimental results show that the performance of the proposed sensorless drive is superior to that of the sensorless drives without filterint.

  • PDF

Topology of Single-Phase PFC Rectifier Circuit with Sinusoidal of Input Current (입력전류의 정현화에 의한 단상PFC정류회로의 토폴로지)

  • Lee, S.H.;Kim, Y.M.;Kwon, S.K.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.290-293
    • /
    • 2002
  • For small capacity rectifier circuits such as these for consumer electronics and appliances, capacitor input type rectifier circuits are generally used. Consequently, various harmonics generated within the power system become a serious problem. Various studies of this effect have been presented previously. However, most of these employ switching devices, such as FETs and the like. The absence of switching devices makes systems more tolerant to over-load, and brings low radio noise benefits. We propose a power factor connection scheme using a LC resonant in commercial frequency without switching devices. In this method, It makes a sinusoidal wave by widening conduction period using the current resonance in commercial frequency, Hence, the harmonic characteristics can be significantly improved, where the lower order harmonics, such as the fifth and seventh orders are much reduced. The result are confirmed by the theoretical and experimental implementations.

  • PDF

Performance Improvement of Grid-Connected Inverter Systems under Unbalanced and Distorted Grid Voltage by Using a PR Controller

  • Lee, Jong-Hyun;Jeong, Hae-Gwang;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.918-925
    • /
    • 2012
  • This paper proposes a control method for grid-connected inverter systems under unbalanced and distorted grid voltage. The proposed method can reduce the power ripple caused by the unbalanced condition and compensate for the low-order harmonics of the output currents caused by the distortion of grid voltage. To reduce the power ripple, our method replaces the two conventional PI controllers with one PR controllers in the stationary frame. PR controllers can implement selective harmonic compensation without excessive computational requirements; the use of these controllers simplifies the method. Both the simulated and experimental results agree well with the theoretical analysis.

A Study of Single-Phase PFC Rectifier Circuit by LC Resonance (LC공진에 의한 단상 PFC정류회로의 연구)

  • Lee, S.H.;Park, J.M.;Kim, Y.M.;Kwon, S.K.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1235-1237
    • /
    • 2003
  • For small capacity rectifier circuits as these for consumer electronics and appli capacitor input type rectifier circuits are gen used. Consequently. various harmonics gen within the power system become a serious pro Various studies of this effect have been pres previously. However. most of these employ swit devices, such as FETs and the like. The absen switching devices makes systems more toleran over -load, and brings low radio noise benefits propose a power factor correction scheme using resonant in commercial frequency without swit devices. In this method. It makes a sinusoidal by widening conduction period using the cu resonance in commercial frequency. Hence, harmonic characteristics can be significantly imp where the lower order harmonics. such as the and seventh orders are much reduced. The resu confirmed by the theoretical and experm implementations.

  • PDF