• Title/Summary/Keyword: low humidity

Search Result 1,036, Processing Time 0.029 seconds

Development of an Architecture Monitoring System Using Wireless Sensor Network (무선 센서네트워크를 이용한 건축물 모니터링 시스템 구현)

  • Chang, Hyung-Jun;Kim, Beom-Soo;Kong, Young-Bae;Park, Gwi-Tae;Shim, II-Joo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.6
    • /
    • pp.568-573
    • /
    • 2007
  • Environmental information (temperature, humidity, vibration, $CO_2$, gas leakage, etc.) of building is an essential item to manage and monitor a building. For intelligent building, it is necessary to get temperature and illumination information to save energy and crack information to prevent structural problems. Moreover, temperature and gas leakage information to alarm a tire precaution, or humidity information to maintain comfortable environment. However, there have not been many researches on systems for gathering environmental information and building maintenance due to high costs. In this paper, wireless sensor network technology is applied to collecting building environmental information. Wireless sensor network is one of the latest issues and has low-power consumption, low-cost, self-configuration features.

Regional Analysis of Dew Possibility in Road Sign Using Meteorological Data (기상자료를 활용한 도로표지 결로의 지역별 발생가능성 분석)

  • Oh, Sei Chang;Kim, Jung Min;Choi, Kee Choo;An, Young Mi
    • International Journal of Highway Engineering
    • /
    • v.15 no.5
    • /
    • pp.195-202
    • /
    • 2013
  • PURPOSES : This study analyzed the regional dew possibility in road sign using meteorological data. METHODS : Four years of meteorological data such as temperature, humidity, dew point, wind velocity were collected and analyzed. As a result of literature review, dew was frequent in large diurnal range, high humidity and weak wind. So, dew possibility was analyzed by (temperature-dew point ${\leq}1^{\circ}C$ and wind velocity ${\leq}$ 1.5m/s). RESULTS : The possibility was analyzed for each meteorological observation point and the point of Suncheon and Bonghwa were selected as the most likely points of dew in road sign. The area of East Coast, Kyungbuk and Kyungnam were relatively low potential. CONCLUSIONS : Alternative with high effect of preventing dew should be selected in high possibility dew area despite of low economics.

A Study on the Heat Recovery Performance of Water Fludized-Bed Heat Exchanger (물유동층 열교환기의 열회수성능 연구)

  • 김한덕;박상일;이세균
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.8
    • /
    • pp.690-696
    • /
    • 2003
  • This paper presents the heat recovery performance of water fluidized-bed heat exchanger. Temperature and humidity ratio of waste gas are considered as important parameters in this study. Therefore, the heat recovery rate through water fluidized-bed heat exchanger for exhaust gases with various temperatures and humidity ratios can be estimated from the results of this study. Mass flow ratio (the ratio of mass flow rate of water to that of gas) and temperature of inlet water are also considered as important operating variables. Increase of heat recovery rate can be obtained through either high mass flow ratio or low temperature of inlet water with resultant low recovered temperature. The heat recovery performance with the mass flow ratio of about up to 10 has been investigated. The effect of number of stages of water fluidized-bed on the heat recovery performance has been also examined in this study.

A study of Agricultural fatigue shoes - A comparative study of heat load by shoe type - (농작업화에 관한 연구 - 신발종류에 따른 열적 부담 비교연구 -)

  • 이경숙;최정화
    • Korean Journal of Rural Living Science
    • /
    • v.7 no.2
    • /
    • pp.99-108
    • /
    • 1996
  • This study has intended to suggest fundamental data to develope and choose appropriate shoes for upland farming in order to prevent health deterioration of women workers and improve work effectiveness and reduce fatigue by wearing appropriate shoes. During 1995. 4. 28 - 5. 10, Fifty women workers in hot pepper farming were observed and major shoe types, which were rubber shoes, walking shoes, slippers, and rubber boots, were selected for the study. During 1995. 10. 9 - 31, two subjects were tested by wearing those shoes in the laboratory where the temperature was 24$\pm$1$^{\circ}C$ and relative humidity 50$\pm$5%RH. And the temperature & humidity on sole and in the shoes, the rectal temperature, skin temperature, blood pressure, pulse, lactate concentration of blood, Flickers' value and subjective sensation were measured. The results were as follows : 1. 84% of women workers mentioned that they need shoes improvement and the order of most frequent shoe types to be worn was rubber shoes, walking shoes, slippers, rubber boots. 2. The rate of women who were unsatisfied with shoes for upland farming is 38 percentages. The reason of unsatisfaction was that feet were in a sweat and alien substances were let into shoes. 3. The temperature & humidity on sole were the lowest in rubber boots during experiment(p<0.01). 4. The relative humidity in the shoes was the highest in rubber boots by 90% and the lowest in walking shoes by 72% during rest And the humidity in slippers and walking shoes were significantly low in experiment(p<0.001). 5. Rubber boots showed the highest rise in rectal temperature by 0.2$^{\circ}C$ showing increase of core temperature (p<0.05). 6. The mean skin temperature during experiment was highest in rubber boots by 33.8$^{\circ}C$(p<0.001).

  • PDF

Browning and Sorption Characteristics of Dried Garlic Flakes with Relative Humidity and Storage Temperature (상대습도와 저장온도에 따른 건조마늘 플레이크의 갈변 및 흡습특성)

  • Kim, Hyun-Ku;Jo, Kil-Suk;Kang, Tong-Sam;Shin, Hyo-Sun
    • Korean Journal of Food Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.176-180
    • /
    • 1987
  • The sorption characteristics of dried garlic flakes stored at various relative humidity and storage temperature were studied. At low relative humidity below RH 51%, the sorption equilibrium was easily attained, whereas at higher relative humidity above RH 67%, the flakes were browned by higher equilibrium moisture content. The flakes were browned at relative humidity above 67% at $20^{\circ}C$ and $35^{\circ}C$, above 84% at $5^{\circ}C$, respectively. The moisture contents of monolayer value for the flakes were ranging from 5.80% to 6.20% (DB) with varying temperatures. And the necessity of moisture-proof packaging material suggested for the long term storage of the flakes because the lower moisture content and storage temperature, the higher driving force of wetting. Regression equation for browning rate prediction with relative humidity and storage temperature of the flakes was determined.

  • PDF

The Spatial and temporal distributions of NET(Net Effective Temperature) with a Function of Temperature, Humidity and Wind Speed in Korea (한반도의 날씨 스트레스 지수 NET(Net Effective Temperature) 분포의 특성)

  • 허인혜;최영은;권원태
    • Journal of the Korean Geographical Society
    • /
    • v.39 no.1
    • /
    • pp.13-26
    • /
    • 2004
  • This paper examined the possibility of NET application for a relative weather stress index in Korea. The characteristic of NET distribution used temperature, relative humidity, wind speed which forecasting at Korean Meteorological Administration were analyzed. Regional critical values of daily maximum NET of stress index for summer resembled the distribution of daily maximum temperature because were not impacted wind and humidity but temperature. Regional critical values of daily minimum NET of stress index for winter distributed variously compared with summer. The highland region and the northern region of Seoul were impacted of low temperature and coastal region which strong wind. The occurrences of stressful days did not vary in summer, but obviously increased in winter after mid-1990s.

Numerical Study on the Discharge of Humidity in the Drum of a Washing Machine (세탁기 드럼 내부의 습기 방출 메커니즘에 대한 수치 연구)

  • Jung, Chung-Hyo;Sohn, Deok-Young;Na, Seon-Uk;Choi, Yun-Ho
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.1
    • /
    • pp.54-61
    • /
    • 2016
  • Washing machine manufacturers typically advise consumers to maintain the relative humidity in the drum less than 80% for three days after the termination of a washing cycle in order to prevent bacteria proliferation. A vent installed in the back of a washing machine is used to release moisture to satisfy this condition. Up to now, the design and installation of the vent have been based on experiments without understanding its roles and physical phenomena. In this study, various CFD results are presented in order to explain the physical mechanism of moisture release in a washing machine. Two methods of moisture release (diffusion and convection) were studied; diffusion was found to be the dominant process in removing moisture. Experiments were also performed to validate this behavior. In addition, this study will aid in the efficient design of vents to keep the relative humidity low inside the drum.

Study of the Periodic Ludwieg Tube Flow with Heat Addition (가열을 수반하는 Ludwieg Tube 유동에 대한 연구)

  • Baek, S.C.;Kwon, S.B.;Kim, H.D.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.450-455
    • /
    • 2001
  • The time-dependent behavior of nonequilibrium condensation of moist air through the Ludwieg tube is investigated with a computational fluid dynamics(CFD) method. The two-dimensional, compressible, Navier-Stokes equations, fully coupled with the condensate droplet growth equations, are numerically solved by a third-order MUSCL type TVD finite-difference scheme, with a second-order fractional time step. Baldwin-Lomax turbulence model is employed to close the governing equations. The computational results are compared with the previous experiments using the Ludwieg tube with a downstream diaphragm. The results clearly show that for an initial relative humidity below 30% there is no periodic oscillation of the condensation shock wave, but for an initial relative humidity over 40% the periodic excursions of the condensation shock occurs in the Ludwieg tube, and the frequency increases with the initial relative humidity. It is also found that total pressure loss due to nonequilibrium condensation in the Ludwieg tube should not be ignored even for a very low initial relative humidity, and the periodic excursions of the condensation shock wave are responsible for the total pressure loss.

  • PDF

Study of Moist Air Flow Through the Ludwieg Tube

  • Baek, Seung-Cheol;Kwon, Soon-Bum;Kim, Heuy-Dong;Toshiaki Setoguchi;Sigeru Matsuo;Raghu S. Raghunathan
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.12
    • /
    • pp.2066-2077
    • /
    • 2003
  • The time-dependent behavior of unsteady condensation of moist air through the Ludwieg tube is investigated by using a computational fluid dynamics (CFD) work. The two-dimensional, compressible, Navier-Stokes equations, fully coupled with the condensate droplet growth equations, are numerically solved by a third-order MUSCL type TVD finite-difference scheme, with a second-order fractional time step. Baldwin-Lomax turbulence model is employed to close the governing equations. The predicted results are compared with the previous experiments using the Ludwieg tube with a diaphragm downstream. The present computations represent the experimental flows well. The time-dependent unsteady condensation characteristics are discussed based upon the present predicted results. The results obtained clearly show that for an initial relative humidity below 30% there is no periodic oscillation of the condensation shock wave, but for an initial relative humidity over 40% the periodic excursions of the condensation shock occurs in the Ludwieg tube, and the frequency increases with the initial relative humidity. It is also found that total pressure loss due to unsteady condensation in the Ludwieg tube should not be ignored even for a very low initial relative humidity and it results from the periodic excursions of the condensation shock wave.

Effect of $M_2CO_3$(M=Li, K) Addition on the Humidity Sensitivity of $V_2O_5$-doped $TiO_2$ ($V_2O_5$를 dopant로 한 $TiO_2$의 감습(感濕)에 미치는 $M_2CO_3$(M=Li, K)의 영향(影響))

  • Kang, Yi-Kug;Song, Chang-Yul;Shin, Yeong-Duck
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.427-429
    • /
    • 1995
  • In this paper, the effect of alkaline oxides on the humidity sensitivity of $V_2O_5$(2mol%)-doped $TiO_2$(98mol%) was investigated as functions of $Li_2CO_3$, $K_2CO_3$, additives (x= 0.0 mol%, 1mol%, 2mol%, 5mol%, 10mol%). 1. The porosity and total intrusion volume of sample containing 1, 2, 5mol% $K_2O$ was increased, and then those of 10mol% $K_2O$ was reduced again. 2. The humidity sensitivity of samples containing 1, 2, 5, 10mol% $K_2O$ were good generally. Especially the sample containing 5mol% $K_2O$ were the better. 3. the stability of the humidity sensitivity of samples containing $K_2O$ at low and high temperatures is very good.

  • PDF