• 제목/요약/키워드: low frequency transformer

검색결과 241건 처리시간 0.037초

고주파 저스트레인 골자극 인가용 진동 시스템 개발 (Development of the High_frequency and Low_strain Vibration Stimulation System for Stimulating Bone)

  • 유주연;박근철;전아영;김윤진;노정훈;전계록
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권2호
    • /
    • pp.177-184
    • /
    • 2011
  • In this study, the system for application of the bone stimulation was implemented using high frequency and low strain method. The whole system consists of the high frequency and low strain vibration stimulation system 177 for stimulating bone, LVDT sensor, and wireless sensor based on tri-axial accelerometer. To evaluate the usefulness of the system, the frequencies and accelerations from function generator were applied to the vibration stimulation system. The range of frequency was 17 Hz, 30 Hz, 45 Hz, 50 Hz and the range of acceleration was set 0.3 g, 0.6 g, 1g, and 2 g. The measured frequencies and acceleration using LVDT (linear variable difference transformer) sensor and 3-axial accelerometer were estimated and compared. The range of frequencies average difference was from 0.0 to 0.004 Hz. As the standard deviation of frequencies estimated by LVDT sensor and accelerometer was below 0.03 Hz and the output frequencies of function generator were similar: Also the results of t-test were satisfied with conditions of p > 0.05. And the acquired frequencies and acceleration from vibration measuring device module were estimated and analyzed. As the mean of accelerations was similar to the acceleration applied from function generator. And the standard deviation of acceleration estimated from vibration measuring device module was ranged from 0.019 g to 0.038 g. Also the results of t-test were satisfied with conditions of p > 0.05. Therefore, these results were airy similar to the acceleration applied from function generator. As a result, the usefulness of the system was confirmed. n a further study, clinical experiment will be carried out with the authorization of IRB (institutional review board) so that appropriate frequency and strain would be investigated in clinical field.

Utility Interactive Solar Power Conditioner with Zero Voltage Soft Switching High frequency Sinewave Modulated Inverter Link

  • Terai H.;Sumiyoshi S.;Kitaizumi T.;Omori H.;Ogura K.;Chandhaket S.;Nakaoka M.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.668-672
    • /
    • 2001
  • The utility interactive sinewave modulated inverter for the solar photovoltaic (PV) power conversion and conditioning with a new high frequency pulse modulated link is presented for domestic residential applications. As compared with the conventional full-bridge hard switching PWM inverter with a high frequency AC link, the simplest single-ended quasi-resonant soft switching sinewave modulated inverter with a duty cycle pulse control is implemented, resulting in size and weight reduction and low-cost. This paper presents a prototype circuit of the single-ended zero voltage soft switching sinewave inverter for solar power conditioner and its operating principle. In addition, this paper proposes a control system to deliver high quality output current. Major design of each component and the power loss analysis under actual power processing is also discussed from an experimental point of view. A newly developed interactive sinewave power processor which has $92.5\%$ efficiencty at 4kW output is demonstrated. It is designed 540mm-300mm-125mm in size, and 20kg in weight.

  • PDF

플라즈마 발생용 전원장치의 LCD 패널 세정효과에 관한 연구 (A Study of LCD Panel Cleaning Effect of Plasma Generation Power Source)

  • 김규식
    • 전자공학회논문지SC
    • /
    • 제45권5호
    • /
    • pp.44-51
    • /
    • 2008
  • UV 램프 시스템은 오랫동안 TFT LCD 나 PDP 의 패널 세정에 사용되어 왔으나, 저렴한 가격의 고성능 세정에 대한 필요성 때문에 고전압 플라즈마 세정에 대한 기술이 개발되고 그 성능이 향상되어 왔다. 장벽방전 (barrier discharge) 혹은 무성방전 (silent discharge)으로 불리는 유전체 장벽 방전 (Dielectric-Barrier Discharges, DBDs) 는 오존 발생기에 주로 이용되어 왔다. 본 논문에서는 LCD 세정용으로 6kW 급 고전압 플라즈마 발생장치를 구현하였다. 3상 입력전압을 직류로 정류한 뒤, 인버터 시스템에 의해 고주파 펄스로 바꾸고 고압 트랜스퍼머를 거쳐 다이오드로 정류한다. 마지막으로, 고압 플라즈마를 발생시키기 위해 양방향 고전압 펄스 스위칭회로가 사용되었다. 실험을 통해 상압 플라즈마가 LCD 패널 세정에 크게 유용함을 보였다.

싱글 코어 푸시풀 포워드 컨버터 동작특성 (Single Core Push Pull Forward Converter Operational Characteristics)

  • 김창선
    • 전력전자학회논문지
    • /
    • 제10권6호
    • /
    • pp.592-597
    • /
    • 2005
  • 푸시 풀 포워드 컨버터는 넓은 입력범위에서 저전압 대전류 특성이 좋고 싱글 EI-EE 코어에 출력 인덕터와 변압기 그리고 입력 필터 등 모든 자성소자들을 포함시킴으로써 집적화할 수 있다. 회로의 여러 변수들에 대한 효율 비교를 통해서 집적화된 싱글 코어 푸시 풀 포워드 컨버터에 대해 고찰하였다. 푸시 풀 포워드 컨버터의 변압기는 Nicera사의 5M FEE 18/8/10C와 NC-2H FEI32/8/10C 코어를 이용하였다. 컨버터의 정격은 입력 전압 $36\~72V$이며 출력은 3.3V, 30A이다. NC-2H FEI32/8/10C코어를 사용하였을 경우 스위칭 주파수가 200kHz이고 부하가 11A일 때 $83.5\%$의 최고 효율이 측정되었다. 전부하(full load)시의 효율은 $76.4\%$, 반부하(half load)일 경우에는 $82.95\%$의 효율이 각각 측정 됐다.

열차운행 안정화를 위한 주회로 기기의 고조파 제한장치 개발에 관한 연구 (A Study on the Development of Harmonic Limit Device for Stabilizing Main Circuit Equipment of Train)

  • 김성준;채은경;강정원
    • 예술인문사회 융합 멀티미디어 논문지
    • /
    • 제8권6호
    • /
    • pp.853-861
    • /
    • 2018
  • 본 논문에서는 전기철도차량이 운행할 때 이상 전압상승에 의한 문제점을 해결할 수 있는 고조파 제한장치의 적용을 제안한다. 운행 중 열차에 전력을 공급하는 교류가선은 25kV/60Hz의 전기를 공급하기 위하여 사용되지만 철도차량 전기장치의 기술발전에 따라 점차 가선에 포함되는 고조파의 크기 및 주파수의 변형이 다양해지고 있다. 최근 열차안전운행에 심각한 문제가 되고 있는 주회로 기기인계기용변압기(Potential Transformer, PT)의 파손이나 주변압기 등의 열손증가는 가선 전원의 고조파로 인한 순간적인 무효전류의 증가로 생기는 현상이다. 주회로 기기의 저주파형 트랜스포머로 고주파수 성분이 유입되면 트랜스 코어의 히스테리시스에 의한 철손 증가 및 기생 커패시턴스에 흐르는 전류가 증가하므로 발열이 발생하게 된다. 이러한 문제 해결을 위해 최근 시퀀스의 조정으로 전력변환 장치의 인위적인 NOTCH OFF가 적용되었다. 그러나, OFF 신호를 받아 제어하는 방식은 지상과 차상 장치의 상호작용으로 동작하므로 불량 발생 시 무효화 되며, 실제 사고가 발생되고 있다. 따라서, 근본적인 문제해결을 위한 방법으로 고조파 전류가 가급적 변압기에 유입되지 않도록 하는 것이 필요하며, 고조파 전류의 유입으로 인해 빈번하게 발생되고 있는 열차사고를 방지하고 안전한 운행을 위해 열차의 실험 분석과 고조파 제한장치의 시뮬레이션을 통한 장치의 타당성 검증을 위한 연구를 수행하였다.

Fe계 연자성 합금 분말의 고온 압연시 자성특성에 미치는 압연인자들의 영향 (Effect of rolling parameters on soft-magnetic properties during hot rolling of Fe-based soft magnetic alloy powders)

  • 김휘준;이주호;이성호;박은수;허무영;배정찬
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.266-269
    • /
    • 2009
  • Iron-based soft magnetic materials are widely used as cores, such as transformer transformers, motors, and generators. Reducing losses generated from soft magnetic materials of these applications results in improving energy conversion efficiency. Recently, the new P/M soft magnetic material realized an energy loss of 68 W/kg with a drive magnetic flux of 1 T, at a frequency of 1 kHz, rivaling general-purpose electromagnetic steel sheet in the low frequency range of 200 Hz to 1 kHz. In this research, the effect of rolling parameters on soft magnetic properties of Fe-based powder cores was investigated. The Fe-based soft magnetic plates were produced by the hot powder rolling process after both pure Fe and Fe-4%Si powders were canned, evacuated, and sealed in Cu can. The soft magnetic properties such as energy loss and coercive power were measured by B-H curve analyzer. The soft magnetic properties of rolled sheets were measured under conditions of a magnetic flux density of 1 T at a frequency of 200 kHz. It was found that rolling reduction ratio is the most effective parameter on reducing both energy loss and coercivity because of increasing aspect ratio with reduction ratio. By increasing aspect ratio from 1 to 9 through hot rolling of pure Fe powder, a significant loss reduction of one-third that of SPS sample was achieved.

  • PDF

Half-Bridge 직렬 공진컨버터 적용 비접촉 충전시스템 (A Contactless Power Charging System using Half-Bridge Series Resonant Converter)

  • 김주훈;송환국;김은수;박성호;김윤호
    • 전력전자학회논문지
    • /
    • 제14권3호
    • /
    • pp.251-259
    • /
    • 2009
  • 본 논문에서는 비접촉 시스템에 있어서 스위칭 소자의 영 전압 스위칭(ZVS)뿐만 아니라 2차측 정류 다이오드 역시 영 전류 스위칭(ZCS)을 이룰 수 있는 비접촉 변압기를 이용한 Half-Bridge 직렬 공진 컨버터 적용 비접촉 충전 시스템을 제안 적용하였다. 본 논문에서 제안한 비접촉 변압기 적용 Half-Bridge 직렬 공진컨버터는 공진 주파수보다 낮은 영역에서 스위칭 동작이 가능하기 때문에 불연속 공진전류에 의한 2차측 정류 다이오드의 영 전류 스위칭(ZCS)이 가능하다. 또한 좁은 주파수 영역에서 제어가 가능하며 높은 전압 이득특성에 따라 적은 턴-수비의 변압기를 사용할 수 있으므로 기존의 비접촉 시스템과 비교해 보았을 때 효율특성을 개선시킬 수 있다. 시뮬레이션과 이론적인 분석을 토대로 3.15W 시제품을 제작하고 실험내용을 서술했다.

전기자동차 충전기용 고역율 콘버어터 회로 (High Power Factor Converter for Electric Vehicle Chargers)

  • 김영민;이수원;모창호;유철로
    • 전력전자학회논문지
    • /
    • 제2권1호
    • /
    • pp.33-38
    • /
    • 1997
  • 전기자동차용 배터리 충전회로에는 일반적으로 다양한 전력용 반도체 스위칭 소자들이 사용되고 있다. 따라서 사용소자의 비선형성에 기인하는 고조파 발생과 큰 피크전류, 낮은 역률 등으로 부근에 있는 전력시스템에 과도기전류나 파형 왜곡 현상을 발생한다. 그리하여 최근에는 기존의 정류회로에서 무시되었던 역율제어, 선 전류의 피크치 억제, 고조파 발생문제 등이 보다 중요하게 되었다. 따라서 본 연구에서는 기존의 문제점들을 해결하기 위해 전압 상승특성을 개선하고 역율이 0.97이상인 고역율 배터리 충전기용 콘버어터 회로를 제안하고자 한다. 제안된 시스템은 정류된 직류전압을 고주파 인버어터에서 교류 공진파로 변환하고, 고주파 트랜스를 통과한 전압을 다시 정류하여 직류전압으로 변환한다. 특히, 이러한 콘버어터의 사용효과는 역율제어에 의해서 크게 개선될 수 있는데, 납축전지를 이용한 실험을 통해 그 타당성을 입증하고자 한다.

  • PDF

Evaluation of Chromosomal Alteration in Electrical Workers Occupationally Exposed to Low Frequency of Electro Magnetic Field (EMFs) in Coimbatore Population, India

  • Balamuralikrishnan, Balasubramanian;Balachandar, Vellingiri;Kumar, Shanmugam Suresh;Stalin, Nattan;Varsha, Prakash;Devi, Subramaniam Mohana;Arun, Meyyazhagan;Manikantan, Pappuswamy;Venkatesan, Chinnakulandhai;Sasikala, Keshavarao;Dharwadkar, Shahnaz N.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권6호
    • /
    • pp.2961-2966
    • /
    • 2012
  • Extremely low frequency electro magnetic fields (EMFs) have been classified as possibly carcinogenic to humans by the International Agency for Research on Cancer. An increased number of chromosomal alterations in peripheral lymphocytes are correlated with elevated incidence of cancer. The aim of the present study was to assess occupationally induced chromosomal damage in EMF workers exposed to low levels of radiation. We used conventional metaphase chromosome aberration (CA) analysis and the micronucleus (MN) assay as biological indicators of non ionizing radiation exposure. In the present study totally 70 subjects were selected including 50 exposed and 20 controls. Informed written consent was obtained from all participants and the study was performed in accordance with the Declaration of Helsinki and the approval of the local ethical committee. A higher degree of CA and MN was observed in exposed subjects compared to controls, the frequency of CA being significantly enhanced with long years of exposure (P<0.05). Moreover increase in CA and MN with age was noted in both exposed subjects and controls, but was significantly greater in the former. The results of this study demonstrated that a significant induction of cytogenetic damage in peripheral lymphocytes of workers occupationally exposed to EMFs in electric transformer and distribution stations. In conclusion, our findings suggest that EMFs possess genotoxic capability, as measured by CA and MN assays; CA analysis appeared more sensitive than other cytogenetic end-points. It can be concluded that chronic occupational exposure to EMFs may lead to an increased risk of genetic damage among electrical workers.

Balanced RF Duplexer with Low Interference Using Hybrid BAW Resonators for LTE Application

  • Shin, Jea-Shik;Song, Insang;Kim, Chul-Soo;Lee, Moon-Chul;Son, Sang Uk;Kim, Duck-Hwan;Park, Ho-Soo;Hwang, Sungwoo;Rieh, Jae-Sung
    • ETRI Journal
    • /
    • 제36권2호
    • /
    • pp.317-320
    • /
    • 2014
  • A balanced RF duplexer with low interference in an extremely narrow bandgap is proposed. The Long-Term Evolution band-7 duplexer should be designed to prevent the co-existence problem with the WiFi band, whose fractional bandgap corresponds to only 0.7%. By implementing a hybrid bulk acoustic wave (BAW) structure, the temperature coefficient of frequency (TCF) value of the duplexer is successfully reduced and the suppressed interference for the narrow bandgap is performed. To achieve an RF duplexer with balanced Rx output topology, we also propose a novel balanced BAW Rx topology and RF circuit block. The novel balanced Rx filter is designed with both lattice- and ladder-type configurations to ensure excellent attenuation. The RF circuit block, which is located between the antenna and the Rx filter, is developed to simultaneously function as a balance-tounbalance transformer and a phase shift network. The size of the fabricated duplexer is as small as $2.0mm{\times}1.6mm$. The maximum insertion loss of the duplexer is as low as 2.4 dB in the Tx band, and the minimum attenuation in the WiFi band is as high as 36.8 dB. The TCF value is considerably lowered to $-16.9ppm/^{\circ}C$.