• Title/Summary/Keyword: low foaming scouring agent

Search Result 4, Processing Time 0.017 seconds

Preparation of Solvent-Type Low Foaming Scouring Agents and Their Scouring Effect (용제형 저기포성 정련제의 제조 및 정련효과)

  • You, Hyuk-Jae;Chung, Dong-Jin;Jung, Choong-Ho;Hahm, Hyun-Sik;Park, Hong-Soo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.156-163
    • /
    • 2004
  • Low foaming scouring agents (LSSA) were prepared by blending of amine salt of dodecylbenzene sulfone, poly (PO-b-EO) glycol, Newpol PP-2000, MJU-100, ethylene glycol and organic solvent. As the results of several tests, LSSA-2 showed good scouring effect, penetrating ability and emulsifiability, and showed not much water pollution. The foaming power of LSSA-2 measured by Ross & Miles method was 11mm foam height immediately after foaming. And the foaming power of LSSA-2 measured by Ross & Clark method were less than 310mm foam height at $30^{\circ}C$, 17mm at $80^{\circ}C$. As a result, LSSA-2 was proved as a good foaming scouring agent.

Preparation of Solvent-Free Low Foaming Scouring Agents and Their Scouring Characteristics (무용제형 저기포성 정련제의 제조 및 정련특성)

  • Park, Hong-Soo;Ahn, Sung-Hwan;Shim, Il-Woo;Jo, Hye-Jin;Hahm, Hyun-Sik;Kim, Yeoung-Chan;Kim, Seong-Kil
    • Journal of the Korean Applied Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.37-44
    • /
    • 2006
  • Solvent-free low foaming scouring agents (LFSC) were prepared by blending of 2-ethylhexylaminoethyl sulfate (2-EHAS), POE(10) octadecylbenzyl- ammonium chloride (POBAC) and Sedlan FF-200 (FF-200). As the results of several tests, 2-EHAS/POBAC/FF-200/water (8g/12g/20g/60g) mixture (LFSC-5) showed good cleaning power, penetrating ability and stability to alkali, and gave less problem in water pollution. The foaming power of LFSC-5 measured by Ross and Miles method was 8mm foam height immediately after foaming, and that measured by Ross and Clark method was less than 300mm foam height at $30^{\circ}C$, and 18mm at $80^{\circ}C$. As a result, LFSC-5 proved a good low foaming scouring agent for fiber.

A Study on the Preparation of Solvent Type Low Foaming Scouring Agents (용제형 저기포성 정련제의 제조에 관한 연구)

  • Park, Eun-Kyung;Park, Hong-Soo;Kim, Young-Keun
    • Applied Chemistry for Engineering
    • /
    • v.4 no.2
    • /
    • pp.358-364
    • /
    • 1993
  • Low foaming scouring agents(SLFS) were prepared by blending of 2-ethylhexylaminoethyl sulfate, Na-dioctyl sulfosuccinate, Newpol PP-2000, MJU-100, ethylene glycol and organic solvent. As the results of several tests, SLFS-2 showed good scouring effect, penetrating ability, emulsifiability and anti-alkaline property, and showed not much water pollution. The foaming power of SLFS-2 measured by Ross & Mites method was 8mm foam height immediately after foaming. And the foaming power of SLFS-2 measured by Ross & Clark method were less than 300mm foam height at $30^{\circ}C$, and 15mm at $80^{\circ}C$. As a result, SLFS-2 was proved as a good low foaming scouring agent.

  • PDF

A Study on the Preparation of Solvent-Free Low Foaming Scouring Agents (무용제형 저기포성 정련제의 제조에 관한 연구)

  • Keun, Jang-Hyoun;Kim, Seung-Jin;Hahm, Hyun-Sik;Park, Hong-Soo
    • Applied Chemistry for Engineering
    • /
    • v.4 no.4
    • /
    • pp.760-769
    • /
    • 1993
  • Solvent-free low foaming scouring agents(LFSA) were prepared by blending of polyoxyethylene(30) octadecylbenzylammonium chloride(POAC), block copolymer of propylene oxide-ethylene oxide[p(PO-b-EO) glycol], Sedlan FF-200(FF-200) and sulfonic acid-amine condensate of polyoxyethylene(10) nonylphenyl ether(PSAC). In consequence of several tests, FF-200/POAC/p(PO-b-EO) glycol/PSAC/water (20g/10g/5g/5g/60g) mixture (LFSA-5) showed good cleaning power, penetrating ability, emulsifiability and stability to alkali, and gave less problem in water pollution. Scouring effect of LFSA-5 was investigated by the change of percentage of exhaustion before and after scouring at various dyeing temperatures. The percentage of exhaustion of the unscoured PET fabric was 4.5% at $70^{\circ}C$, while that scoured with LFSA-5 was 1.3% at the same temperature, which proved LFSA-5 to be a good scouring agent. Moreover, the foaming power of LFSA-5 measured by Ross and Miles method was 6mm foam height immediately after foaming, and that measured by Ross and Clark method was less than 300mm foam height at $30^{\circ}C$, and 20mm at $80^{\circ}C$. As a result, LFSA-5 proved a good low foaming scouring agent.

  • PDF