• 제목/요약/키워드: low concentration collector

검색결과 16건 처리시간 0.027초

Optical analysis of low concentration evacuated tube solar collector

  • Teles, Mavd R.;Carvalho, Raquel;Ismail, Kamal A.R.
    • Advances in Energy Research
    • /
    • 제5권3호
    • /
    • pp.227-237
    • /
    • 2017
  • The continuous increase of emission rates of green house gases and the effects on global warming added a new dimension to the problem of substituting the petroleum and its derivatives by environment friendly and sustainable energy sources for the world. Solar and wind energy appear at the top of the list of renewable of high potential, widely available, of dominated technology and well accepted. Brazil is one of the few countries in the world that receives number hours of sunshine exceeding 3,000 hours per year with a daily average of 4.5 to 6 kWh. However, this potential is largely unexplored and poorly tapped. The number of renewable systems implanted in Brazil has grown in recent years, but still insignificant when compared, for example, with Germany and Spain among others. This paper presents the results of an optical study on small concentration solar collector with evacuated tube enveloping the absorber and internal reflective surface fixed on the bottom part of the evacuated tube. The designed collector has a 2D geometrical concentration ratio between 2.455 and 4.91. The orientation of the solar collector, the ratio of the radius of the receiver to the radius of the absorber, the incidence angle for each period of the year, the collector inclination angle, the aperture angle of the reflective surface, concentration and optical efficiency were determined. The ray traces and flux distribution on the absorber of the evacuated tube solar collector were determined by using the program Ray Optics Simulation. The optical efficiency varies during the year according to the solar declination. For the periods were the solar declination is close to zero the efficiencies are maximum, and the variation during the day is around 25.88% and 99.9%. For the periods were the solar declination is maximum the efficiencies are minimum, and the variation during the day is around 23.78% and 91.79%.

Application of a General Gas Electrode Model to Ni-YSZ Symmetric Cells: Humidity and Current Collector Effects

  • Shin, Eui-Chol;Ahn, Pyung-An;Seo, Hyun-Ho;Lee, Jong-Sook
    • 한국세라믹학회지
    • /
    • 제53권5호
    • /
    • pp.511-520
    • /
    • 2016
  • Electrolyte-supported symmetric Ni-YSZ cermet electrodes of ca. $23{\mu}m$ were prepared by screenprinting and the impedance was measured as a function of humidity from 2% to 90% balanced in $H_2$ at a total flow rate of 50 sccm. The Ni felt current collector of 1 mm thickness exhibited a Gerischer-like gas concentration impedance in the low frequency range, which was similarly observed in the cermet-supported solid oxide cells, while the Pt paste collector exhibited only electrochemical polarization. The electrochemical polarization of both samples was modeled by a non-ideal diffusion-reaction transmission line model including CPEs with ${\alpha}$= 0.5. In the case of the Pt paste collector, all the Bisquert parameters exhibited humidity dependence to the -1/2 power, supporting a non-faradaic chemical reaction mechanism at three phase boundaries. Consequently, the surface diffusivity and reaction rate increased linearly with humidity. Less pronounced humidity dependence and somewhat lower utilization length with an Ni felt collector can be attributed to the diffusion-limited gas flow through the collector.

전기방사 조건이 셀룰로오스 웹 형상에 미치는 영향 (Parametric Study on the Morphology of Electrospun Cellulose Web)

  • 정연수;정영진
    • 한국염색가공학회지
    • /
    • 제24권1호
    • /
    • pp.62-68
    • /
    • 2012
  • Cellulose was electrospun over water collector and the cellulose solution was prepared using N-methyl-morpholine N-oxide/water(nNMMO/$H_2O$). The morphology of electrospun cellulose was investigated by scanning electron microscopy (SEM). SEM images showed that the fiber formation depended on processing parameters such as solution concentration, applied electric field strength, solution feeding rate and temperature of water in coagulation bath. High concentration, low temperature of water bath, and low feeding rate were more favorable to obtain fiber morphology. All the variables affected on the fluidity of the cellulose solution and diffusion of NMMO. Low fluidity and fast diffuision of NMMO was critical for obtaining fiber morphology.

차량용 유도전력 집전 장치의 특성해석 (The Modeling of inductive power collector for vehicle)

  • 한경희;이병송;김도원;백수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1610-1612
    • /
    • 2005
  • In this paper, the inductive power collector using electromagnetic induction for vehicle such as the PRT(Personal Rapid Transit) system is suggested and some ideas for power collector design to improve the power transfer performance are presented. The proposed the inductive power collector is used for the PRT system, which has a large air-gap and demands a large electrical power capability. But, low output power is generated due to a loosely coupled characteristic of the large air-gap. Therefore, double layer construction of secondary winding, which was divided in half to increase both output current and output voltage was suggested. Also, a model of power collector and parallel winding structure and a model of concentration/decentralization winding are presented, in addition, the performance of inductive power collector to alignment condition between the primary power line and the inductive power transformer was verified by computer simulation of 2kW model.

  • PDF

백운모광의 품위향상에 관한 연구 (A study on the Beneficiation of Muscovite Ore)

  • 이재장;최수용
    • 산업기술연구
    • /
    • 제9권
    • /
    • pp.29-41
    • /
    • 1989
  • A general study on the upgrading of mica minerals which are mainly found in pegmatite deposits was carried out for the purpose of developing a technique for recovering mica in form of comercial grade products. By the way the grade one of about 5~6% $K_2O$ still is not developed. The target of this research work is to be establish a process for the efficient concentration of muscovite, containing more than 10% $K_2O$. The tests are applied to incraese the recovery and grade of concentrates in term of variations of conditions. The test sample consists of mainly muscovite and gangue mineral such as quartz, pyrite and chlorite. Decantation and shaking table tests were ineffective to up-grade this low grade one, but flotation method gave satisfactory result. By means of grade one, but flotation method gave satisfactory result. By means of grindability tests, an optimum result could be obtained from the sample ground to -48mesh feed size. The flotation result indicates that the dodecyl ammonium chloride used as a cationic collector is effective on the negatively charged surface, while the sodium dodecyl sulfate as an anionic collector is effective on the positively charged surface. Muscovite was floated by petroleum sulfonate as well as amine type collector, it also floated by MIBC as well as pine oil frother under well condition. Fine muscovite concentrates of about 10.68% $K_2O$ was obtained with 22.4% yield, by decantation, the muscovite concentrates of 10.10% $K_2O$ was obtained with 23.54% yield, by table concentration, the muscovite concentrates of 11.51% $K_2O$ was obtained with 23.0% yield by flotation.

  • PDF

공조용 박형 전기집진장치 개발에 관한 연구 (A Study on the Development of Thin ESP for High Efficient Air-conditioner)

  • 홍영기;신수연;조정수;박정후
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권1호
    • /
    • pp.34-38
    • /
    • 1999
  • In order to develop a thin type ESP(Electrostatic Precipitator) for high efficient air-conditioner with low concentration of ozone generation, collecting electrode spacing should be narrower than that from Deutsch formula and minimizes discharge current in ionizer. In this paper, the effect of applied voltage on the precipitation efficiency and ozone concentration of scroll type ESP was studied. As a result, precipitation efficiency(one pass) was improved by about 30[%] from increment of collector voltage(3.5[㎸]). Precipitation efficiency was increased with increasing ionizer voltage. And after some point, the efficiency was saturated. At the point, voltage and ionizer current was 5.2[㎸] and 95$[\muA]$ per meter respectively. At these applied voltage conditions, ozone concentration was saturated about 0.01[ppm] after 3 hours in 23$[m^3]$ closed room test.

  • PDF

흑색 황산3가크롬을 이용한 태양열 흡열판 선택흡수막 도금기술 (Technology of selective absorber coatings on solar collectors using black chromium+3 sulfate acid on substrates)

  • 엄태인;여운택;김동찬
    • 한국태양에너지학회 논문집
    • /
    • 제33권3호
    • /
    • pp.27-35
    • /
    • 2013
  • One of the most important factors that have a large influence on performance of the solar water heater system is performance of the solar collector, more detailedly, coating technology on the surface of the solar collector, which can provide high solar absorptance and low emittance. The core of the coating technology is to coat solar selective surfaces. In this study, various performance experiments are carried out using $Cr_2(SO_4)_3{\cdot}15H_2O$ coating technology. Here, IGBT(Insulated Gate Bipolar Transistor) of 5000A-15V was used as the surface processing rectifier which can stably output power and also can control voltage and current. The plating solution mainly contains black chrome$^{+3}$ concentration, H-y Conductivity, N-u Complex, NF Additive and NC-2 Wetter. Before applying the black chrome coating on the copper plate, optimal conditions are provided by using various preprocessing methods such as removal of fat, activation, electrolytic polishing, nickel strike, copper sulfate plating and bright neckel plating, and then the automatic continuous coating experiment are performed according to plating time and cathode current density. In the experiment, after the removal of fat, chemical polishing, nickel strike and activation processes as the preprocessing methods, the black chrome coating was performed in a plate solution temperature of $28^{\circ}C$ and a cathode current density of $18A/cm^2$ for 90 seconds. The thickness of chrome and nickel on the coated plate is $0.389{\mu}m$, $159{\mu}m$ respectively. As a result of the coating experiment, it showed the most excellent performance having a high solar absorptance of 98% and a low emittance of $5{\pm}1%$ when the black chrome surface had a thickness of $0.398{\mu}m$.

인장강도가 뛰어난 직물집전체를 이용한 탄소전극의 축전식 탈염공정에서의 제염효과 (The Salt Removal Efficiency Characteristics of Carbon Electrodes Using Fabric Current Collector with High Tensile Strength in a Capacitive Deionization Process)

  • 성두리;김대수
    • Korean Chemical Engineering Research
    • /
    • 제58권3호
    • /
    • pp.466-473
    • /
    • 2020
  • 직물집전체는 에너지 효율이 높은 담수화 방식인 축전식탈염(Capacitive deionization: CDI)시스템에서 유망한 전극 재료가 될 수 있다. 직물집전체의 매력적인 특징 중 하나는 인장강도가 강하다는 것인데, 기계적 강도가 약한 그라파이트 호일 전극의 대안이 될 수 있다. 또한 섬유적 특성으로 인하여 쉽게 형상을 만들 수 있고, 다공성 물질이라는 점과 섬유 간 공간은 수용성 매질의 흐름을 원활하게 해 준다. 본 연구에 사용된 섬유는 도전성 LM fiber와 carbon fiber를 사용한 방적사를 이용하여 직조 구조로 만들어졌으며, 인장강도는 319 MPa로 그라파이트 호일에 비해서 약 60 배 정도 더 강하다. 전극슬러리의 점도, 흡착전압, 공급액의 유량, 공급액의 농도를 변화시켜 가면서 염 제거효율을 측정하여 결과를 분석하였다. NaCl 200 mg/L, 20 ml/min, 흡착전압 1.5 V 조건에서, 단위 셀에서 43.9%, 100개의 셀을 적층한 모듈에서는 59.8%의 염 제거 효율을 각각 보였다. 단위 셀에서는 흡착전압이 1.3, 1.4, 1.5 V로 증가함에 따라 염 제거효율이 증가하다가 1.6과 1.7 V로 증가하면서 염 제거 효율은 감소하였다. 그러나 100 셀 적층 모듈에서는 1.5 V 이상의 전압에서도 염 제거효율이 완만한 증가세를 나타내었다. 공급액의 유량을 증가시켰을 때 염 제거율은 감소하였고, 또한 공급액의 농도를 증가시켰을 때에도 염 제거율은 감소하였다.

Operating Parameters for Glutamic Acid Crystallization in Displacement Ion Exchange Chromatography

  • Lee, Kisay
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제2권2호
    • /
    • pp.117-121
    • /
    • 1997
  • Glutamic acid can be crystallized inside cation exchange column when displacer NaOH concentration is high enough to concentrate displaced glutamic acid beyond its solubility limit. Resulting crystal layer of glutamic acid was moved with liquid phase through the column, and thus could be eluted from the column and recovered in fraction collector. For the purpose of enhancing crystal recovery, effects of operating parameters on the crystal formation were investigated. The increase in the degree of crosslinking of resin favored crystal recovery because of its low degree of swelling. Higher concentration of displacer NaOH was advantageous. If NaOH concentration is too high, however, crystal recovery was lowered due to the solubility-enhancing effects of high pH and ionic strength. The decrease of mobile phase flow rate enhanced crystal recovery because enough time to attain local equilibrium could be provided, but film diffusion would control the overall crystal formation with extremely low flow rate. Lower temperature reduced solubility of glutamic acid and thus favored crystal formation unless the rate of ion exchange was severely reduced. The ion exchange operated by displacement mode coupled with crystallization was advantageous in reducing the burden of further purification steps and in preventing purity-loss resulted from overlapping between adjacent bands.

  • PDF

Experimental investigation of the influence of salinity gradient on low-concentration surfactant flooding in Berea sandstone

  • Ebaga-Ololo, Jestril;Chon, Bo Hyun
    • Journal of Industrial and Engineering Chemistry
    • /
    • 제68권
    • /
    • pp.355-363
    • /
    • 2018
  • There are serious issues with the application of surfactant flooding as a third recovery method, such as surfactant slug losses. In this study,the impact of the salinity gradient on the remobilization of oiltrapped in Berea sandstone was investigated by emphasizing the surfactant adsorption gradient and phase behavior to determine the optimal salinity of the chosen surfactant concentration for investigating the salinity gradient. Three salinity-gradient schemes were applied to six cores saturated with light and heavy oils. The positive salinity gradient provided the best recovery results with an in situ microemulsion formation that could be observed in the fluid collector.