• 제목/요약/키워드: low NOx

검색결과 611건 처리시간 0.024초

Atmospheric Photochemistry in Low-and High-NOx Regimes

  • Kim, Do-Yong;Soda, Satoshi;Kendo, Akira;Oh, Jai-Ho
    • 한국환경과학회지
    • /
    • 제16권1호
    • /
    • pp.1-8
    • /
    • 2007
  • Atmospheric photochemistry of $O_3-NOx-RH$ were considered theoretically, to clarify the reasons for the different trends of between the formation of photochemical oxidants (Ox) and its primary pollutants for the Low-and High-NOx regimes. Equations of OH, $HO_2$, and production of ozone ($O_3$) as a function of nitrogen oxides (NOx) and reactive hydrocarbons (RH) were represented in this study. For the Low-NOx regime, $HO_2$ radical is proportional to RH but independent of NOx. OH radical is proportional to NOx but inversely-proportional to RH. $O_3$ production is proportional to NOx but has a weak dependence on RH. For the High-NOx regime, OH and $HO_2$ radicals concentrations and $O_3$ production are proportional to RH but inversely-proportional to NOx. In addition, the Osaka Bay and surrounding areas of Japan were evaluated with the mass balance of odd-hydrogen radicals (Odd-H) using CBM-IV photochemical mechanism, in order to distinguish the Low- and High-NOx regimes. The Harima area (emission ratio, RH/NOx = 6.1) was classified to the Low-NOx regime. The Hanshin area (RH/NOx = 3.5) and Osaka area (RH/NOx = 4.3) were classified to the High-NOx regime.

연소기에서의 다단 저 NOx 버너의 수치 및 실험적 연구 (Numerical & Experimental Study For Burner of Low NOx Formation of Multi-Stage In a Combustor)

  • 최윤기;강경태;김용모
    • 한국연소학회:학술대회논문집
    • /
    • 대한연소학회 2003년도 제27회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.65-74
    • /
    • 2003
  • Air pollution included Nitric Oxide(NOx) from heating boilers is increased by pursuing better life. Development of low NOx emission boiler is strongly needed. However commercial burner for heating boiler is also asked to be thermal efficient and low-cost manufactuable in addition to low NOx emission. Small space for combustor including burner is usually allowed. In this study, parametric study of compact low NOx burner for heating boiler was done using numerical analysis and experiments. Commerical computational fluid dynamic(CFD) program named CFX 5-6 was used for numerical analysis of low NOx burner using turbulent diffusion flame. Comparison of outlet NO and outlet temperature under various equivalence ratio and fuel flow rate was performed between experiment and numerical analysis.

  • PDF

희박-예혼합 저 NOx 연소기 설계에 대한 연구 (The Study for Designs of Lean-Premixed low NOx Combustor)

  • 임암호;김한석;안국영;이상민;김용모
    • 한국연소학회:학술대회논문집
    • /
    • 대한연소학회 2003년도 제27회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.83-88
    • /
    • 2003
  • The concept of lean-premixed combustion in gas turbine combustor operation has become a standard in recent years as an effective means to meet stringent environmental standards on NOx emissions. Various types of air-fuel premixer, which affect greatly NOx emission and stability of lean-premixed low NOx combustor, were investigated experimentally to reduce the NOx emission. One type of the premixers is selected by experiments and applied it to 70kW class lean-premixed gas turbine combustor. The exit temperature and emissions of CO and NOx were measured with equivalence ratios at ambient pressure. From the results, the emissions of CO and NOx were influenced by the type of air-fuel premixer. As the mixing length of air and fuel is longer, the NOx and CO emission were decreased in the primary reaction zone. Compared with of conventional combustor, the lean-premixed low NOx combustor has low NOx emission characteristics.

  • PDF

시험용 연소로에서의 다단 저 NOx 버너의 실험 및 수치적 연구 (Experimental and Numerical Study of Low NOx Multi-Staged Burner in the Test Combustor)

  • 최윤기;강경태;임기석;고동완;김용모
    • 대한기계학회논문집B
    • /
    • 제28권11호
    • /
    • pp.1339-1347
    • /
    • 2004
  • Development of the low NOx heating boiler was strongly asked due to severe air pollution and the large number of boilers in korea. Compactness of the commercial boiler was also important because of low manufacturing cost and easy installation. In this study. newly developed compact low NOx burner, using turbulent gas diffusion combustion with multi-staged air supplies and multiple fuel nozzles, was investigated. Comparison study of the new burner was performed between experimental results and computational analysis. Commercial computational fluid dynamic(CFD) program named CFX-5.6 was used for numerical analysis of the low NOx burner inside the test combustor. Comparisons of experiment data and numerical result were performed under various equivalence ratio and fuel flow rate.

산업 보일러용 오일버너에서의 저 NOx 연소 연구 (A Study on Low-NOx Combustion in an Oil Burner for an Industrial Boiler)

  • 신명철;김세원;박주원;방병열;양원;고영건
    • 한국연소학회지
    • /
    • 제14권1호
    • /
    • pp.19-24
    • /
    • 2009
  • A novel low NOx oil burner of 0.7 MW (for a 1 ton steam/hr industrial boiler) was designed and tested to investigate the combustion characteristics through in-flame measurement and flue gas analysis. Flame shape was observed by CCD camera and $CH^*/{C_2}^*$ radical distribution in the flame were observed, along with measurement of flue gas composition such as NOx and CO, for various heat inputs, excess airs and pressure of the fuel spary nozzles. The flame showed the two-zone structure: fuel-rich and fuel-lean zone, which was very favorable for the low-NOx combustion, and the NOx emission for haevy oil combustion was significantly reduced to < 150 ppm at 4 % $O_2$, compared with the NOx level of a conventional heavy oil burner.

  • PDF

산업용 보일러에 적용된 저 NOx 미분탄버너의 연소성능 평가 (Performance of Low NOx Coal Burner in Industrial Coal Fired Boiler)

  • 김상현;김혁제;김혁필;송시홍;이익형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1751-1755
    • /
    • 2004
  • Increasing environmental pressures to reduce NOx emission are being placed on coal-fired boilers. To meet the environmental requirements, Doosan Heavy Industries & Construction Co., Ltd.(Doosan) has developed low NOx pulverized coal burner. Low NOx pulverized coal burner has already delivered, and it's combustion performance was evaluated to the NOx and Unburned Carbon(UBC) during the commissioning tests. The test results are shown that the strong relationship is existed between NOx and OFA flow rate, and also fuel-N fraction of coal has effected on NOx emission.

  • PDF

저 NOx2단 선회 분무식 노즐 개발 및 실기적용 연구 (A Study for Development and Application of a Low NOx 2-staged Swirl Atomizer)

  • 송시홍;김혁필;안상택;이익형
    • 대한기계학회논문집B
    • /
    • 제25권12호
    • /
    • pp.1793-1801
    • /
    • 2001
  • A study of low NOx atomizer was carried out to reduce nitrogen oxides(NOx) in a liquid fuel burner flame. The basic concept of NOx reduction in this atomizer is the fuel 2-staging combustion which is generated by a single atomizer forming two different stoichiometric flames. Two orifices swirl atomizer was selected and modified to realize this concept, and it was tested to obtain the design process of low NOx atomizer. These experiments were achieved to find out the relationship between the injection pressures and the flow rate, spray angle and drop size of swirl atomizer as well as to confirm the NOx reduction concept in real plant(power boiler). In comparison between experimental and theoretical results, the correct discharge coefficient and spray angle were obtained. In real burning test, NOx reduction rate was reached to above 27% of the case using conventional swirl atomizer.

석탄연소보일러 개조공사에 적용된 저NOx 미분탄 버너의 성능 평가 (Performance Evaluation of Low NOx Pulverized Coal Burner Applied in Coal Fired Boiler Refurbishment Project)

  • 김상현;송시홍;김혁제;김혁필
    • 한국연소학회지
    • /
    • 제11권4호
    • /
    • pp.22-26
    • /
    • 2006
  • To meet the environmental requirements, Doosan Heavy Industries & Construction Co., Ltd. (Doosan) had developed low NOx pulverized coal burner and it was applied to boiler retrofit project, 130 ton/hr coal fired cogeneration boiler, in 2003. NOx emissionand unburned carbon (UBC) in fly ash were measured during the commissioning tests. In this paper, the operation results of low NOx pulverized coal burner installed in 130 ton/hr coal fired boiler are presented. Burners emitted 160 ppm (@6 % $O_2$ basis) NOx and 3 % UBC with Chinacoal containing 0.86 % fuel nitrogen. And also it was shown that NOx emission rate of low NOx pulverized coal burner is linearly increased with fuel-nitrogen fraction of coal.

  • PDF

회전 아크 적용 플라즈마 저 NOx 버너 연소특성 (Characteristics of Low NOx Plasma Burner Incorporating with Rotating Arc Plasma)

  • 김관태;강희석;이대훈;송영훈;박재언
    • 한국수소및신에너지학회논문집
    • /
    • 제22권6호
    • /
    • pp.934-941
    • /
    • 2011
  • Characteristics of low NOx burner is investigated. Low NOx burner introduced in this paper adopts two staged combustion with plasma burner for the 1st stage combustion. Extensive parametric tests were done to figure out the effect of burner stoichiometry, staged thermal load, electric power for plasma generation. Overall NOx production by burner shows effective reduction by adopting plasma staged burner. and the aspects depends on the fuel stoichiometry of 1st stage burner or operating condition of plasma burner. It is promising to use plasma burner as an alternative tools of low NOx burner technology.

마이크로 스케일 난류에 의한 화염안정성 및 NOx 생성 (Flame Stability and NOx Formation by Micro scale Turbulence)

  • 김인수;서정무;이근선;이충원
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2001년도 제23회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.57-62
    • /
    • 2001
  • The effect of micro scale turbulence on flame structure and stability were experimentally investigated by changing the area of micro turbulence generator(MTG) and air velocity in terms of low NOx and high efficiency combustion. NOx and CO concentration were also measured for different MTG areas to investigate whether a vane swirler having MTG has a possibility of using as part for low NOx combustor. From the obtained results, it is shown that flame stability region increases and flame size becomes small as MTG area increases since MTG in itself makes small scale recirculation flow and swirler does large scale recirculation one. It is also shown that low NOx concentration(about 20${\sim}$30ppm@$O_2$ 11%) is achieved for all MTG areas without any increase in CO concentration regardless of air velocity range tested in this study when the equivalence ratio is 0.7. The results obtained in this study can give basic guideline for the design of compact low NOx high efficiency combustor using a vane swirler having MTG.

  • PDF