• Title/Summary/Keyword: loss minimization control

Search Result 70, Processing Time 0.027 seconds

Segment-based Buffer Management for Multi-level Streaming Service in the Proxy System (프록시 시스템에서 multi-level 스트리밍 서비스를 위한 세그먼트 기반의 버퍼관리)

  • Lee, Chong-Deuk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.11
    • /
    • pp.135-142
    • /
    • 2010
  • QoS in the proxy system are under heavy influence from interferences such as congestion, latency, and retransmission. Also, multi-level streaming services affects from temporal synchronization, which lead to degrade the service quality. This paper proposes a new segment-based buffer management mechanism which reduces performance degradation of streaming services and enhances throughput of streaming due to drawbacks of the proxy system. The proposed paper optimizes streaming services by: 1) Use of segment-based buffer management mechanism, 2) Minimization of overhead due to congestion and interference, and 3) Minimization of retransmission due to disconnection and delay. This paper utilizes fuzzy value $\mu$ and cost weight $\omega$ to process the result. The simulation result shows that the proposed mechanism has better performance in buffer cache control rate, average packet loss rate, and delay saving rate with stream relevance metric than the other existing methods of fixed segmentation method, pyramid segmentation method, and skyscraper segmentation method.

Optimized Low-Switching-Loss PWM and Neutral-Point Balance Control Strategy of Three-Level NPC Inverters

  • Xu, Shi-Zhou;Wang, Chun-Jie;Han, Tian-Cheng;Li, Xue-Ping;Zhu, Xiang-Yu
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.702-713
    • /
    • 2018
  • Power loss reduction and total harmonic distortion(THD) minimization are two important goals of improving three-level inverters. In this paper, an optimized pulse width modulation (PWM) strategy that can reduce switching losses and balance the neutral point with an optional THD of three-level neutral-point-clamped inverters is proposed. An analysis of the two-level discontinuous PWM (DPWM) strategy indicates that the optimal goal of the proposed PWM strategy is to reduce switching losses to a minimum without increasing the THD compared to that of traditional SVPWMs. Thus, the analysis of the two-level DPWM strategy is introduced. Through the rational allocation of the zero vector, only two-phase switching devices are active in each sector, and their switching losses can be reduced by one-third compared with those of traditional PWM strategies. A detailed analysis of the impact of small vectors, which correspond to different zero vectors, on the neutral-point potential is conducted, and a hysteresis control method is proposed to balance the neutral point. This method is simple, does not judge the direction of midpoint currents, and can adjust the switching times of devices and the fluctuation of the neutral-point potential by changing the hysteresis loop width. Simulation and experimental results prove the effectiveness and feasibility of the proposed strategy.

Centralized Control Algorithm for Power System Performance using FACTS Devices in the Korean Power System

  • Kang, Sang-Gyun;Seo, Sang-Soo;Lee, Byong-Jun;Chang, Byung-Hoon;Myung, Ro-Hae
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.3
    • /
    • pp.353-362
    • /
    • 2010
  • This paper presents a centralized control algorithm for power system performance in the Korean power system using Flexible AC Transmission Systems (FACTS) devices. The algorithm is applied to the Korean power system throughout the metropolitan area in order to alleviate inherent stability problems, especially concerns with voltage stability. Generally, control strategies are divided into local and centralized control. This paper is concerned with a centralized control strategy in terms of the global system. In this research, input data of the proposed algorithm and network data are obtained from the SCADA/EMS system. Using the full system model, the centralized controller monitors the system condition and decides the operating point according to the control objectives that are, in turn, dependent on system conditions. To overcome voltage collapse problems, load-shedding is currently applied in the Korean power system. In this study, the application of the coordination between FACTS and switch capacitor (SC) can restore the solvability without load shedding or guarantee the FV margin when the margin is insufficient. Optimal Power Flow (OPF) algorithm, for which the objective function is loss minimization, is used in a stable case. The results illustrate examples of the proposed algorithm using SCADA/EMS data of the Korean power system in 2007.

Comparative Study of Performance of Switching Control and Synchronous Notch Filter Control for Active Magnetic Bearings (능동 자기 베어링을 위한 동기 노치필터 제어기와 스위칭 제어기의 성능 비교 연구)

  • Yoo, Seong Yeol;Noh, Myounggyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.4
    • /
    • pp.511-519
    • /
    • 2013
  • Switching controllers for active magnetic bearings are claimed to minimize the copper losses because they do not use bias currents. In this study, we compare the performances of the switching controller with those of the widely used proportional-derivative (PD) controller. The PD controller is combined with a synchronous notch filter to reduce the effect of the unbalance disturbance. For a fair and objective comparison, the PD controller is designed systematically. The switching controller is designed so that the dynamics of the two controllers are almost identical. A system model is developed. This model includes the flexible modes of the rotor and the dynamics of the sensors and amplifiers. The simulation results show that the switching controller indeed reduces the copper loss at lower speeds. However, it fails to operate around the speed close to the bending mode of the rotor.

Zero Torque Control of Switched Reluctance Motor for Integral Charging (충전기 겸용 스위치드 릴럭턴스 전동기의 제로토크제어)

  • Rashidi, A.;Namazi, M.M;Saghaian, S.M.;Lee, D.H.;Ahn, J.W.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.2
    • /
    • pp.328-338
    • /
    • 2017
  • In this paper, a zero torque control scheme adopting current sharing function (CSF) used in integrated Switched Reluctance Motor (SRM) drive with DC battery charger is proposed. The proposed control scheme is able to achieve the keeping position (KP), zero torque (ZT) and power factor correction (PFC) at the same time with a simple novel current sharing function algorithm. The proposed CSF makes the proper reference for each phase windings of SRM to satisfy the total charging current of the battery with zero torque output to hold still position with power factor correction, and the copper loss minimization during of battery charging is also achieved during this process. Based on these, CSFs can be used without any recalculation of the optimal current at every sampling time. In this proposed integrated battery charger system, the cost effective, volume and weight reduction and power enlargement is realized by function multiplexing of the motor winding and asymmetric SR converter. By using the phase winding as large inductors for charging process, and taking the asymmetric SR converter as an interleaved converter with boost mode operation, the EV can be charged effectively and successfully with minimum integral system. In this integral system, there is a position sliding mode controller used to overcome any uncertainty such as mutual inductance or DC offset current sensor. Power factor correction and voltage adaption are obtained with three-phase buck type converter (or current source rectifier) that is cascaded with conventional SRM, one for wide input and output voltage range. The practicability is validated by the simulation and experimental results by using a laboratory 3-hp SRM setup based on TI TMS320F28335 platform.

A Study on the State Estimaion of Dynamic system using Fuzzy Estimator (퍼지 추정기에의한 동적 시스템의 상태 추정에 관한 연구)

  • 문주영;박승현;이상배
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1997.10a
    • /
    • pp.350-355
    • /
    • 1997
  • The problem of mathematical model for an unknown system by measureing its input-output data pairs is generally referred to as state estimates. The state estimation problem is often of importance in its own right since we may want to know the value of the states. For instance, in navigation, we may take noisy positional fixes using satelite or radar navigation, and the estimator can use these measurements to provide accurate estimates of current position, hedaing, and velocity. And the state estimates can also be used for control purposes. Then it is very important to know the state of plant. In this paper, the theory of the minimization of a loss function was used to design the fuzzy system. Here, the used teory is Least Square Esimation method. This parametrization has the Linear in the parameters charcteristic that allows standard parameter estimation technique to be used to estimate the parameters of the fuzzy system. The combination of the fuzzy system and the estimation m thod then performs as a nonlinear estimator. If several fuzzy label are defined for the input variables at the antecedent part, the fuzzy system then behaves as a collection of nonlinear estimators where different regions of rules have different parameters. In simulation results, the fuzzy model controlled a difference in the structure between the actual plant and the fuzzy estimator. It is also proved that the fuzzy system is equivalent to its transformed system. therefore we was able to get the state space equation of system with the estimated paramater.

  • PDF

Determination of BTB HVDC Operating Point in Metropolitan area (대도시 내 BTB HVDC 투입 시 운전점 결정 방안)

  • Lee, Jae Hyeong;Yoon, Minhan;Han, Changhee;Jang, Gilsoo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.331-332
    • /
    • 2015
  • Since $20^{th}$ century, along with the rapid industrial advancement, the concentrated urban development in specific large cities have made people migrate to those cities, thus causing problems in the power system stability. In case of Korea, more than 40% of the power system demand comes from the consumers in Seoul Metropolitan area and the rate is expected to increase. With the continuous increase of power demand, in order to meet the demand for system reliability improvement, the power system was multi-looped for reliability enhancement, the problem of fault current happened. In this situation, there are several methods for fault current reduction likes current limiting reactor, replacing circuit breaker, splitting busses, etc. But these methods reached its limit, power system needs more fundamental solutions such as grid segmentation. In this paper, we assume grid segmentation already has been progressed using VSC BTB HVDC. Then, this paper discusses operating point of HVDC in metropolitan area considering loss minimization and handy flow control. The simulation is proceeded on 2027 KEPCO system.

  • PDF

UPFC Device: Optimal Location and Parameter Setting to Reduce Losses in Electric-Power Systems Using a Genetic-algorithm Method

  • Mezaache, Mohamed;Chikhi, Khaled;Fetha, Cherif
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • Ensuring the secure operation of power systems has become an important and critical matter during the present time, along with the development of large, complex and load-increasing systems. Security constraints such as the thermal limits of transmission lines and bus-voltage limits must be satisfied under all of a system’s operational conditions. An alternative solution to improve the security of a power system is the employment of Flexible Alternating-Current Transmission Systems (FACTS). FACTS devices can reduce the flows of heavily loaded lines, maintain the bus voltages at desired levels, and improve the stability of a power network. The Unified Power Flow Controller (UPFC) is a versatile FACTS device that can independently or simultaneously control the active power, the reactive power and the bus voltage; however, to achieve such functionality, it is very important to determine the optimal location of the UPFC device, with the appropriate parameter setting, in the power system. In this paper, a genetic algorithm (GA) method is applied to determine the optimal location of the UPFC device in a network for the enhancement of the power-system loadability and the minimization of the active power loss in the transmission line. To verify our approach, simulations were performed on the IEEE 14 Bus, 30 Bus, and 57 Bus test systems. The proposed work was implemented in the MATLAB platform.

Theoretical Heat Flow Analysis and Vibration Characteristics During Transportation of PCS(Power Conversion System) for Reliability (전력변환장치 캐비넷에서의 내부발열 개선을 위한 열유동 분석 및 유통안전성 향상을 위한 진동특성 분석)

  • Joo, Minjung;Suh, Sang Uk;Oh, Jae Young;Jung, Hyun-Mo;Park, Jong-Min
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.28 no.2
    • /
    • pp.143-149
    • /
    • 2022
  • PCS needs to freely switch AC and DC to connect the battery, external AC loads and renewable energy in both directions for energy efficiency. Whenever converting happens, power loss inevitably occurs. Minimization of the power loss to save electricity and convert it for usage is a very critical function in PCS. PCS plays an important role in the ESS(Energy Storage System) but the importance of stabilizing semiconductors on PCB(Printed Circuit Board) should be empathized with a risk of failure such as a fire explosion. In this study, the temperature variation inside PCS was reviewed by cooling fan on top of PCS, and the vibration characteristics of PCS were analyzed during truck transportation for reliability of the product. In most cases, a cooling fan is mounted to control the inner temperature at the upper part of the PCS and components generating the heat placed on the internal aluminum cooling plate to apply the primary cooling and the secondary cooling system with inlet fans for the external air. Results of CFD showed slightly lack of circulating capacity but simulated temperatures were durable for components. The resonance points of PCS were various due to the complexity of components. Although they were less than 40 Hz which mostly occurs breakage, it was analyzed that the vibration displacement in the resonance frequency band was very insufficient. As a result of random-vibration simulation, the lower part was analyzed as the stress-concentrated point but no breakage was shown. The steel sheet could be stable for now, but for long-term domestic transportation, structural coupling may occur due to accumulation of fatigue strength. After the test completed, output voltage of the product had lost so that extra packaging such as bubble wrap should be considered.

Innovative approaches to the health problems of rural Korea (한국농촌보건(韓國農村保健)의 문제점(問題點)과 개선방안(改善方案))

  • Loh, In-Kyu
    • Journal of agricultural medicine and community health
    • /
    • v.1 no.1
    • /
    • pp.5-9
    • /
    • 1976
  • The categories of national health problems may be mainly divided into health promotion, problems of diseases, and population-economic problems which are indirectly related to health. Of them, the problems of diseases will be exclusively dealt with this speech. Rurality and Disease Problems There are many differences between rural and urban areas. In general, indicators of rurality are small size of towns, dispersion of the population, remoteness from urban centers, inadequacy of public transportation, poor communication, inadequate sanitation, poor housing, poverty, little education lack of health personnels and facilities, and in-accessibility to health services. The influence of such conditions creates, directly or indirectly, many problems of diseases in the rural areas. Those art the occurrence of preventable diseases, deterioration and prolongation of illness due to loss of chance to get early treatment, decreased or prolonged labour force loss, unnecessary death, doubling of medical cost, and economic loss. Some Considerations of Innovative Approach The followings art some considerations of innovative approaches to the problems of diseases in the rural Korea. 1. It would be essential goal of the innovative approaches that the damage and economic loss due to diseases will be maintained to minimum level by minimizing the absolute amount of the diseases, and by moderating the fee for medical cares. The goal of the minimization of the disease amount may be achieved by preventive services and early treatment, and the goal of moderating the medical fee may be achieved by lowering the prime cost and by adjusting the medical fees to reasonable level. 2. Community health service or community medicine will be adopted as a innovative means to disease problems. In this case, a community is defined as an unit area where supply and utilization of primary service activities can be accomplished within a day. The essential nature o the community health service should be such activities as health promotion, preventive measures, medical care, and rehabilitation performing efficiently through the organized efforts of the residents in a community. Each service activity should cover all members of the residents in a community in its plan and performance. The cooperation of the community peoples in one of the essential elements for success of the service program, The motivations of their cooperative mood may be activated through several ways: when the participation of the residents in service program of especially the direct participation of organized cooperation of the area leaders art achieved through a means of health education: when the residents get actual experience of having received the benefit of good quality services; and when the health personnels being armed with an idealism that they art working in the areas to help health problems of the residents, maintain good human relationships with them. For the success of a community health service program, a personnel who is in charge of leadership and has an able, a sincere and a steady characters seems to be required in a community. The government should lead and support the community health service programs of the nation under the basis of results appeared in the demonstrative programs so as to be carried out the programs efficiently. Moss of the health problems may be treated properly in the community levels through suitable community health service programs but there might be some problems which art beyond their abilities to be dealt with. To solve such problems each community health service program should be under the referral systems which are connected with health centers, hospitals, and so forth. 3. An approach should be intensively groped to have a physician in each community. The shortage of physicians in rural areas is world-wide problem and so is the Korean situation. In the past the government has initiated a system of area-limited physician, coercion, and a small scale of scholarship program with unsatisfactory results. But there might be ways of achieving the goal by intervice, broadened, and continuous approaches. There will be several ways of approach to motivate the physicians to be settled in a rural community. They are, for examples, to expos the students to the community health service programs during training, to be run community health service programs by every health or medical schools and other main medical facilities, communication activities and advertisement, desire of community peoples to invite a physician, scholarship program, payment of satisfactory level, fulfilment of military obligation in case of a future draft, economic growth and development of rural communities, sufficiency of health and medical facilities, provision of proper medical care system, coercion, and so forth. And, hopefully, more useful reference data on the motivations may be available when a survey be conducted to the physicians who are presently engaging in the rural community levels. 4. In communities where the availability of a physician is difficult, a trial to use physician extenders, under certain conditions, may be considered. The reason is that it would be beneficial for the health of the residents to give them the remedies of primary medical care through the extenders rather than to leave their medical problems out of management. The followings are the conditions to be considered when the physician extenders are used: their positions will be prescribed as a temporary one instead of permanent one so as to allow easy replacement of the position with a physician applicant; the extender will be under periodic direction and supervision of a physician, and also referral channel will be provided: legal constraints will be placed upon the extenders primary care practice, and the physician extenders will used only under the public medical care system. 5. For the balanced health care delivery, a greater investment to the rural areas is needed to compensate weak points of a rurality. The characteristics of a rurality has been already mentioned. The objective of balanced service for rural communities to level up that of urban areas will be hard to achieve without greater efforts and supports. For example, rural communities need mobile powers more than urban areas, communication network is extremely necessary at health delivery facilities in rural areas as well as the need of urban areas, health and medical facilities in rural areas should be provided more substantially than those of urban areas to minimize, in a sense, the amount of patient consultation and request of laboratory specimens through referral system of which procedures are more troublesome in rural areas, and more intensive control measures against communicable diseases are needed in rural areas where greater numbers of cases are occurred under the poor sanitary conditions.

  • PDF