• 제목/요약/키워드: loss index

검색결과 1,421건 처리시간 0.03초

경제적인 품질보증수준확보를 위한 공정능력지수의 최적화에 관한 연구 (Optimization of Process Capability Index for Economic Coalify Assurance Level)

  • 송서일
    • 산업경영시스템학회지
    • /
    • 제11권18호
    • /
    • pp.71-80
    • /
    • 1988
  • Process capability implies the qualitative capability of a process, and it is necessary to specify the process capability by quantification and to evaluate the level with the specified standardizaion. But the process capability index is currently used to evaluate the performance of quality control activity. without considering the characteristics of process structure or the economy of management. Here the researcher would like to redefine process capability and emphasize its index may be used as the measure of managerial assessment and the objective of process quality control in full consideration of the economic aspects of process characteristics. Too little or too much process capability causes a loss of or excess. The proper economic level of process capability varies to each process. The procedure of taking the optimum process capability index is derived from the expected profit function, whereas each method is studied in cases of normal process with one-sided specification and two-sided specification. In addition, the process capability index is presented as a method of quality assurance. And an example is exhibited on wrapping process of 'A' company. The results of this study are summarized at follows. First, though the norminalization of the process capability index is possible by the existing methods, the optimum process capability index can vary to the situation of each process. So, the optimum process capability index which is suggested in this dissertation should be used as the standard to assess process capability. Second, the process capability index can take its effect not just in indicating quality control or managerial records but also in the management of high qualify assurance.

  • PDF

WTO 체제가 의류산업에 미치는 영향(제1보) -관세율변화가 최종 의류소비자에게 미치는 영향- (Impact of Clothing Tariff on Consumer Surplus in Korea after WTO Agreements(Part I))

  • 전양진
    • 한국의류학회지
    • /
    • 제22권1호
    • /
    • pp.108-115
    • /
    • 1998
  • The objective of this study was to estimate the quantitative loss of the consumer surplus due to the tariffs on clothing imports during the WTO starting periods. For 1984-1996, the import price elasticity of the clothing was estimated from the regression of pet capita clothing imports on Per capita GNP, import price index and domestic producer price index. Then the quantitative losses of the consumer surplus in clothing were obtained from the simplified formula for 1990-1995. In spite of the decrease in textiles St clothing tariff rates, consumer costs were increasing, which was caused by the tremendous increase in clothing imports during the same period. The loss of the consumer surplus was 7131 billion wonts in 1995, which accounted for 6.4% of the total clothing expenditure.

  • PDF

FHD 공정에 의한 저손실 실리카 슬랩 도파로 형성 (Fabrication of Low Loss Silica Slab Waveguide by Flame Hydrolysis Deposition)

  • 심재기;김태홍;신장욱;박상호;김덕준;성희경
    • 한국세라믹학회지
    • /
    • 제37권6호
    • /
    • pp.524-529
    • /
    • 2000
  • Silica slab wavegudie was fabricated on Si substrates by FHD for planar optical passive devices. The slab waveguide consists of lower clad and core layers, where core layer index is controlled by GeO2 addition. Doping of GeO2 in silica is difficult because of the low deposition density due to nonspherical particle generation in FHD process. Silica core particles deposited at various conditions such as flame temperature and substrate scanning were analyzed by SEM and TEM. As the flame temperature increased, the surface roughness of the core layer was decreased up to 3.6 nm after consolidation. Index difference and thickness of core of slab waveguide were 0.3%, 8$\mu\textrm{m}$ respectively. Measured optical loss at TE mode was <0.04 dB/cm at 1.3$\mu\textrm{m}$ and <0.06 dB/cm at 1.55$\mu\textrm{m}$.

  • PDF

송전손실 상태식별법에 의한 정태 전압안정성 해석 (Static Voltage Stability Analysis based on T/L Loss System Identification)

  • 전동훈;김정훈;심건보;이봉용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.145-148
    • /
    • 1992
  • The best index should show the margins to the operating limit at the present operating point without much efforts. Such voltage collapse proximity index has been proposed in this study. Differently from the normal procedure in which every bus load is increased at the same propotion, bus load increase toward the direction of T/L loss increase has been applied in this study. Sample studies show the usefulness and the practical applicability in voltage stability analysis.

  • PDF

Quasi-Distributed Water Detection Sensor Based On a V-Grooved Single-Mode Optical Fiber Covered with Water-Soluble Index-Matched Medium

  • Kim, Dae Hyun;Kim, Kwang Taek
    • 센서학회지
    • /
    • 제24권1호
    • /
    • pp.1-5
    • /
    • 2015
  • The V-grooved single-mode fiber in which a surface part of the core was removed was investigated as a quasi-distributed water detection sensor. In the normal state, the V-grooved region is filled and covered with a specific RI (Refractive Index)-matched medium, and the sensor experiences minimal optical loss. As water invades the V-grooved region, the material is dissolved and removed, and a considerable optical loss occurs owing to the large RI difference between the fiber core and water. The experimental results showed the feasibility of the device as a sensor element of the quasi-distributed water detection sensor system based on general optical time domain reflectometry (OTDR).

타구치 로버스트 계획에서 응용모형의 개발 (Development of Application Models Based on the Robust Design)

  • 최성운
    • 대한안전경영과학회지
    • /
    • 제13권1호
    • /
    • pp.203-209
    • /
    • 2011
  • This study develops three new models that are practically applicable to three stages of Taguchi's robust design, which includes system design, parameter design and tolerance design. In system design, the Multiple Loss Function Analysis(MLFA) and Overall Loss Index(OLI) which reflect upon weight of characteristics and importance of specification are developed. Moreover parameter design presents Process Capability Index(PCI), $C_{PUK}$ and $C_{PLK}$, in order to segregate Signal-To-Noise Ratio(SNR) into accuracy and precision for an evaluation of relative comparison. In addition, tolerance design presents the new model of allowance computation for assembled product which is primarily derived from safety margin(SM) considering functional limit and specification. The guideline of those three new models, which include systematic charts and applicable illustrations, offers convenience for practitioners in the field. Hence, the practical applications could be made with the steps of robust designs such as system design, parameter design and specification allowance design.

배전계통 리클로우저 기반의 자율적 고장복구 방법론 (The Self-Fault Restoration Methodology based on the Recloser in the Distribution Systems)

  • 고윤석
    • 전기학회논문지
    • /
    • 제58권9호
    • /
    • pp.1681-1688
    • /
    • 2009
  • This paper proposes a new fault restoration method which adopts the recloser as top agent to release the problems of the data concentration and fault processing delay of the existing DAS(distribution Automation System) under the ubiquitous distribution system. In proposed method, top agent collects the data based on the multi-casting communication with the tie switches of the interconnection point, and then selects a closed switch(tie switch) to transfer the sound outage load to other feeders based on the heuristic search strategy step by step until the load transfer work is finished. Here, a new heuristic rule is developed which can guarantee the relational load balancing and line loss from the collected voltage data. Finally, the several faults are simulated for typical multi-section and multi-interconnection distribution system to prove the effectiveness of the proposed strategy, in particular, for each simulation cases, the load balancing index and line loss index of the obtained solution from the proposed method is compared with those of all of feasible solutions.

Design and Analysis of Refractometer Based on Bend Waveguide Structure with Air Trench for Optical Sensor Applications

  • Ryu, Jin Hwa;Lee, Woo-Jin;Lee, Bong Kuk;Do, Lee-Mi;Lee, Kang Bok;Um, Namkyoung;Baek, Kyu-Ha
    • ETRI Journal
    • /
    • 제36권5호
    • /
    • pp.841-846
    • /
    • 2014
  • This study proposes a novel optical sensor structure based on a refractometer combining a bend waveguide with an air trench. The optical sensor is a $1{\times}2$ splitter structure with a reference channel and a sensing channel. The reference channel has a straight waveguide. The sensing channel consists of a U-bend waveguide connecting four C-bends, and a trench structure to partially expose the core layer. The U-bend waveguide consists of one C-bend with the maximum optical loss and three C-bends with minimum losses. A trench provides a quantitative measurement environment and is aligned with the sidewall of the C-bend having the maximum loss. The intensity of the output power depends on the change in the refractive index of the measured material. The insertion loss of the proposed optical sensor changes from 3.7 dB to 59.1 dB when the refractive index changes from 1.3852 to 1.4452.

침시술이 경피수분 손실량과 피부 수분함유량에 미치는 임상적 연구 (Pilot Clinical Trial to Evaluate the Efficacy of Acupuncture Therapy on TEWL and Skin hydration)

  • 박수연
    • 동의생리병리학회지
    • /
    • 제32권4호
    • /
    • pp.271-276
    • /
    • 2018
  • The purpose of pilot clinical trial is to evaluate the efficacy and safety of acupuncture therapy on TEWL(Transepidermal Water Loss) and skin hydration. A total of 36 human who visited Dongshin University Oriental Medical Center from October 2nd, 2015 to July 31st, 2016 were included in the pilot clinical trial. Acupuncture therapy was performed at Gokji(LI11) and Daechu(GV14). We observed change of TEWL(Transepidermal Water Loss), skin hydration before and after acupuncture therapy. In the primary endpoint, index of TEWL showed a statistically significant decline($8.01{\pm}2.55{\rightarrow}6.58{\pm}1.97g/h/m2$, $7.40{\pm}2.65{\rightarrow}4.99{\pm}1.89g/h/m2$). Index of skin hydration showed statistical significance($52.83{\pm}6.53{\rightarrow}56.82{\pm}7.24$, $63.50{\pm}8.57{\rightarrow}64.96{\pm}8.48$). To evaluate the safety, vital sign check were conducted and showed no statistically significant result. And there were no severe adverse events during this study. According to the above pilot clinical trial, it is suggested acupuncture therapy were effective for skin moisturizing.

동결온도가 진공포장 동결육의 품질에 미치는 영향 (Effects of Freezing Temperature on Quality of Vacuum Packaging Freezed Beef)

  • 정인철;김도완;문귀임;강세주;김기영;문윤희
    • 한국식품영양학회지
    • /
    • 제11권4호
    • /
    • pp.409-415
    • /
    • 1998
  • This study was carried out to investigate the effects of freezing temperature on quality of vacuum packaging freezed beef. In case of thaw drip loss, the freezing of -3$^{\circ}C$ and -20$^{\circ}C$ were 5.23% and 5.17% to 60 days respectively, were increased significantly during freezing. The cooking loss of water bath and pan were increased significantly during freezing than the beginning of freezing, but were no different between -3$^{\circ}C$ and -20$^{\circ}C$. The salt soluble protein extractability was decreased during freezing, the -20$^{\circ}C$ freezing was higher than -3$^{\circ}C$freezing. The water soluble protein extractability was increased during freezing higher than during freezing. The myoglobin denatured percentage of the -3$^{\circ}C$ freezing was higher than -20$^{\circ}C$ freezing, the 15 days storage of -3$^{\circ}C$ freezing was highest to 96%. The shear force value was not change during freezing, the myofibrillar fragmentation index during freezing was higher than the beginning of freezing, but was not change during freezing. The pH was decreased to freezing 45 days, after that increased.

  • PDF