• 제목/요약/키워드: loss curves

검색결과 270건 처리시간 0.031초

액상화.횡방향 영구지반변형을 받는 연속된 지중매설관로의 구조적 손상도곡선 도출 (Fragility Curve of Continuous Buried Pipeline subjected to Transverse Permanent Ground Deformation due to Liquefaction)

  • 김태욱;임윤묵
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.358-365
    • /
    • 2006
  • In this study, fragility curves of continuous buried pipelines subjected to transverse PGD (permanent ground deformation) due to liquefaction are proposed. For the waterworks system, continuos buried pipelines made of ductile iron, poly ethylene, and poly vinyl chloride are analyzed and fragility curves are drawn. Fragility curves are based on the repetitive analyses results and formulated with the dominant factors of behaviour of buried pipeline. With the use of fragility curves, engineers can estimate the status of damage of buried pipeline without overall knowledge of relevant features. Especially, fragility curves proposed in this study will act as a major module of earthquake loss estimation method. Moreover, critical value of magnitude and width of transverse PGD (by which the full damage status of buried pipelines are induced) are estimated. With the use of regression curves of these values, pre evaluation of seismic safety of buried pipelines located within liquefaction hazardous region will be possible.

  • PDF

평창강 지하수 함양곡선 연구 (Case Study: Groundwater Recharge Hydrograph in Pyeongchang River)

  • 곽재원
    • 한국습지학회지
    • /
    • 제23권2호
    • /
    • pp.173-182
    • /
    • 2021
  • 수자원의 보전과 관리를 위해서는 갈수시의 유량감쇄 특성을 파악하는 것이 중요한 과제 중에 하나이다. 감쇄특성을 하천 유량자료를 이용하여 표현하기 위해서 여러 복잡한 특성을 고려하여야 하므로, 편의성을 위하여 선형 감쇄분석이 주로 적용되어 왔다. 그러나, 최근의 연구에서 제시된 지하수 유출과 비피압대수층의 저장능력의 비선형성을 고려하면, 비선형 감쇄모형의 적용성이 더 높다고 할 수 있다. 따라서, 본 연구의 목적은 유출자료를 이용하여 지하수의 증발손실, 저류 및 재함양과 같은 비선형 특성을 고찰하는 데 있다. 한강의 상류인 평창강 유역의 유출자료를 이용하여 분석을 수행하였으며, 지하수 수지를 구성하는 주요한 요소인 지하수 유출, 증발손실, 저류, 재함양에 대해서 고찰하고 정량화하였다. 연구결과에 따라서, 식생에 의한 지하수 손실이 감쇄곡선을 편향시키는 것으로 나타났다. 또한, 계절적 강우와 잠재증발산 경향을 감쇄분석에 적용하여 월별 증발산 손실과 지하수 함양량을 정량화하여 제시하였다.

Photoelectic BV Light Curves of Algol and the Interpretations of the Light Curves

  • Kim, Ho-Il
    • Journal of Astronomy and Space Sciences
    • /
    • 제2권1호
    • /
    • pp.35-45
    • /
    • 1985
  • Standardized B and V photoelectric light curves of Algol are made with the obsevations obtained during 1982-84 with the 40-cm and the 61-cm reflectors of Yonsei University Observatory. These light curves show asymmetry between ascending and descending shoulders. The ascending shoulder is 0.02 mag brighter than descending shoulder in V light curve and 0.03mag in B light curve. These asymmetric light crves are interpreted as the result of inhomogeneous energy distribution on the surface of one star of the eclipsing pair rather than the result of gaseous stream flowing from KOIV to B8V star. The 180-year periodicity, so called great inequality, are most likely the result proposed by Kim et al.(1983) that the abrupt and discrete mass losses of cooler component may be the cause of this orbital change. The amount of mass loss deduced from these discrete period changes turned out to be of the order of $10^{-6}$ - $10^{-5}M_\odot$.

  • PDF

Derivation of analytical fragility curves using SDOF models of masonry structures in Erzincan (Turkey)

  • Karimzadeh, Shaghayegh;Kadas, Koray;Askan, Aysegul;Erberik, M. Altug;Yakut, Ahmet
    • Earthquakes and Structures
    • /
    • 제18권2호
    • /
    • pp.249-261
    • /
    • 2020
  • Seismic loss estimation studies require fragility curves which are usually derived using ground motion datasets. Ground motion records can be either in the form of recorded or simulated time histories compatible with regional seismicity. The main purpose of this study is to investigate the use of alternative ground motion datasets (simulated and real) on the fragility curves. Simulated dataset is prepared considering regional seismicity parameters corresponding to Erzincan using the stochastic finite-fault technique. In addition, regionally compatible records are chosen from the NGA-West2 ground motion database to form the real dataset. The paper additionally studies the effects of hazard variability and two different fragility curve derivation approaches on the generated fragility curves. As the final step for verification purposes, damage states estimated for the fragility curves derived using alternative approaches are compared with the observed damage levels from the 1992 Erzincan (Turkey) earthquake (Mw=6.6). In order to accomplish all these steps, a set of representative masonry buildings from Erzincan region are analyzed using simplified structural models. The results reveal that regionally simulated ground motions can be used alternatively in fragility analyses and damage estimation studies.

Effect of biaxial stress state on seismic fragility of concrete gravity dams

  • Sen, Ufuk;Okeil, Ayman M.
    • Earthquakes and Structures
    • /
    • 제18권3호
    • /
    • pp.285-296
    • /
    • 2020
  • Dams are important structures for management of water supply for irrigation or drinking, flood control, and electricity generation. In seismic regions, the structural safety of concrete gravity dams is important due to the high potential of life and economic loss if they fail. Therefore, the seismic analysis of existing dams in seismically active regions is crucial for predicting responses of dams to ground motions. In this paper, earthquake response of concrete gravity dams is investigated using the finite element (FE) method. The FE model accounts for dam-water-foundation rock interaction by considering compressible water, flexible foundation effects, and absorptive reservoir bottom materials. Several uncertainties regarding structural attributes of the dam and external actions are considered to obtain the fragility curves of the dam-water-foundation rock system. The structural uncertainties are sampled using the Latin Hypercube Sampling method. The Pine Flat Dam in the Central Valley of Fresno County, California, is selected to demonstrate the methodology for several limit states. The fragility curves for base sliding, and excessive deformation limit states are obtained by performing non-linear time history analyses. Tensile cracking including the complex state of stress that occurs in dams was also considered. Normal, Log-Normal and Weibull distribution types are considered as possible fits for fragility curves. It was found that the effect of the minimum principal stress on tensile strength is insignificant. It is also found that the probability of failure of tensile cracking is higher than that for base sliding of the dam. Furthermore, the loss of reservoir control is unlikely for a moderate earthquake.

Design and EM Analysis of Dual Band Hilbert Curve Based Wilkinson Power Divider

  • Kaur, Avneet;Singh, Harsimran;Malhotra, Jyoteesh
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권5호
    • /
    • pp.257-260
    • /
    • 2016
  • In this paper, two configurations (T-type and Y-type) of dual band Wilkinson Power Divider based upon Hilbert curves are presented. Formerly, the concept of Hilbert Curves was implemented in only designing microstrip antennas. In power dividers, this is the very first attempt of incorporating them for size reduction. In addition to this, an effect of inculcation of high-dielectric constant layer (Hafnium-oxide, HfO2, εr= 25) between a substrate and top metallization in both configurations was investigated. The proposed configurations are designed on a high resistive silicon substrate (HRS) for L and S bands with resonating frequencies of 1.575 and 3.4 GHz. Both configurations have return loss that is better than 20 dB and an insertion loss of around 6 dB; isolation better than 30 dB was achieved for both models.

Seismic fragility curves using pulse-like and spectrally equivalent ground-motion records

  • Surana, Mitesh
    • Earthquakes and Structures
    • /
    • 제19권2호
    • /
    • pp.79-90
    • /
    • 2020
  • 4- and 8-storey reinforced-concrete frame buildings are analyzed under the suites of the near-fault pulse-like, and the corresponding spectrally equivalent far-fault ground-motion records. Seismic fragility curves for the slight, moderate, extensive, and complete damage states are developed, and the damage probability matrices, and the mean loss ratios corresponding to the Design Basis Earthquake and the Maximum Considered Earthquake hazard levels are compared, for the investigated buildings and sets of ground-motion records. It is observed that the spectrally equivalent far-fault ground-motion records result in comparable estimates of the fragility curve parameters, as that of the near-fault pulse-like ground-motion records. As a result, the derived damage probability matrices and mean loss ratios using two suites of ground-motion records differ only marginally (of the order of ~10%) for the investigated levels of seismic hazard, thus, implying the potential for application of the spectrally equivalent ground-motion records, for seismic fragility and risk assessment at the near-fault sites.

Buckling capacity of uniformly corroded steel members in terms of exposure time

  • Rahgozar, Reza;Sharifi, Yasser;Malekinejad, Mohsen
    • Steel and Composite Structures
    • /
    • 제10권6호
    • /
    • pp.475-487
    • /
    • 2010
  • Most of steel structures in various industries are subjected to corrosion due to environmental exposure. Corrosion damage is a serious problem for these structures which may reduce their carrying capacity. These aging structures require maintenance and in many cases, replacement. The goal of this research is to consider the effects of corrosion by developing a model that estimates corrosion loss as a function of exposure time. The model is formulated based on average measured thickness data collected from three severely corroded I-beams (nearly 30 years old). Since corrosion is a time-dependent parameter. Analyses were performed to calculate the lateral buckling capacity of steel beam in terms of exposure time. Minimum curves have been developed for assessment of the remaining lateral buckling capacity of ordinary I-beams based on the loss of thicknesses in terms of exposure time. These minimum curves can be used by practicing engineers for better estimates on the service life of corrosion damaged steel beams.

의류건조기의 열적 특성에 관한 실험 (Thermal Characteristics of an Electric Clothes Dryer)

  • 김준호;장석필;최철진;황교식;이호재
    • 대한기계학회논문집B
    • /
    • 제33권8호
    • /
    • pp.629-634
    • /
    • 2009
  • In this paper, drying mechanism is analyzed for improving the energy efficiency of an electric clothes dryer which consumes more electric power than other appliances. For the purpose, characteristic curves of the dryer such as temperature, relative humidity, evaporation rate, mass transfer coefficient, remaining moisture content curves are experimentally obtained. Based on the experimental results and analysis of drying mechanism, the effect of power of a heater and heat loss on the power consumption of an electric clothes dryer are systematically presented. These results demonstrate the feasibility of controlling heat loss at the heater as well as the backduct component to decrease the power consumption of an electric clothes dryer.

의류건조기의 열적 특성에 관한 실험 (Thermal Characteristics of an Electric Clothes Dryer)

  • 김준호;장석필;최철진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2262-2267
    • /
    • 2008
  • In this paper, drying mechanism is analyzed for improving the energy efficiency of an electric clothes dryer which consumes more electric power than other appliances. For the purpose, characteristic curves of the dryer such as temperature, relative humidity, evaporation rate, mass transfer coefficient, remaining moisture content curves are experimentally obtained. Based on the experimental results and analysis of drying mechanism, the effect of power of a heater and heat loss on the power consumption of an electric clothes dryer are systematically presented. These results demonstrate the feasibility of controlling heat loss at the heater as well as backduct component to decrease the power consumption of an electric clothes dryer.

  • PDF