• Title/Summary/Keyword: loose sandy ground

Search Result 27, Processing Time 0.019 seconds

Behavior characteristics of Soft Ground Improved by Granular Pile (Granular Pile에 의해 개량된 연약지반의 거동특성)

  • Chun, Byung-Sik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.2 no.4
    • /
    • pp.63-72
    • /
    • 2001
  • As construction cases on soft ground are increasing, the necessity of ground improvement is also increasing. Granular pile is one of the methods for soft clay and for loose sandy soil. In our country, SCP(Sand Compaction Pile) method using sand material has been mainly used to improve soft ground, but Granular pile with crushed-stone was not used much. However, alternative material such that crushed-stone is needed to substitute for sand due to the environmental and economical problems. In this study, staged load test and consolidation test were performed in the laboratory to observe the behavior of soft ground improved by Granular pile. In order to evaluate the characteristics such as bearing capacity, drainage, and settlement, sand and crushed-stone were applied as each pile material. The test results show that crushed-stone has higher bearing capacity and less settlement than those of sand under similar pore water pressure condition. Therefore, crushed-stone is determined to be appropriate as substitute for sand.

  • PDF

A Study on the Change of Electrical Characteristics of Sand (모래지반에서의 전기적 특성 변화에 관한 연구)

  • Han, Yushik;Yoo, Ki Cheong
    • Journal of Korean Society of Disaster and Security
    • /
    • v.10 no.1
    • /
    • pp.61-66
    • /
    • 2017
  • It is very important to understand the electromagnetic characteristics of underground media in GPR (Ground Penetrating Radar) survey. Depending on the electrical characteristics of the underground medium, the energy of the electromagnetic wave becomes relatively small, and reflection from the interface may become difficult. In this study, electrical characteristics of sandy soils under various (loose and dense) conditions were analyzed. As a result, In dry sand is the dielectric constant increased as the relative density increased, and the dielectric constant and electrical conductivity increased as the moisture content of the sand increased.

A Study on Applicability of the Calculation Method for Settlement of Stone Column (쇄석말뚝의 침하량 산정방법 적용성에 관한 연구)

  • Han, Sangsoo;Jung, Suntae;Lee, Jinhyung;Kim, Bokyoung;Kim, Kyungmin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.17 no.3
    • /
    • pp.5-12
    • /
    • 2016
  • Stone column is the method that replace soft ground such as weak clay and loose sand with gravel or crushed stone which has relatively high stiffness and low compressive. Stone column increases bearing capacity of the soft ground, reduces settlement, produces ground improvement effect by consolidation drain, and is effective to prevent soil liquefaction in sandy ground during an earthquake. Stone column has been used in many civil works, and has recorded quite a lot of construction achievement internationally, but there is no standardized settlement calculation method yet. Therefore, in this study, the applicability of the existing theoretical equations were evaluated through comparison and analysis to predict a reasonable settlement of the Stone column. Consequently, Hook's law formula was verified to be the most close to numerical analysis.

A Study on the Behavior of Sand Compaction Piles in Soft Ground (연약지반에 적용된 모래다짐말뚝의 거동특성에 관한 수치해석 연구)

  • Lee, Jungsang;Chung, sungrae;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.8
    • /
    • pp.33-38
    • /
    • 2011
  • Presently, domestic SCP method with low replacement ratio is required as alternative in order to overcome the profitability of the sand resource because of the deficiency phenomenon of the sand resource by the actual condition design and construction is made by SCP method with low replacement ratio more than 70% for the port construction in the safe side. Sand compaction pile(SCP) method has been mainly used to improve the properties of soft clay or loose sandy ground. In design of SCP at soft clay ground, it is very important to determine the stress concentration ratio of composite ground relevant to the area replacement ratio. In this study, 2-dimensional FEM analyses were carried out to evaluate the stress concentration ratio of composite ground depending upon the area replacement ratio. When the interpretation result replacement ratio was 30%, the stress assigned rate showed and as the replacement ratio was high, the stress assigned rate according to the sinkage showed the low stress assigned rate.

Damage Analysis of Nearby Structures with the Consideration of Tunnel Construction Conditions in Sandy and Clayey Ground (모래 및 점토지반에서 터널시공조건을 고려한 인접구조물의 손상도 분석)

  • Son, Moorak;Yun, Jongcheol
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.1C
    • /
    • pp.53-63
    • /
    • 2011
  • This paper investigates the effects of tunnelling-induced ground movements on nearby structures, considering soil-structure interactions of different ground (loose sand, dense sand, soft clay, stiff clay) and construction conditions (ground loss). The response of four-story block structures, which are subjected to tunnelling-induced ground movements, has been investigated in different ground and construction conditions (ground loss) using numerical analysis. The structures for numerical analysis has been modelled using Discrete Element Method (DEM) to have real cracks when the shear and tensile stress exceed the maximum shear and tensile strength. The response of four-story block structures has been investigated with a ground movement magnitude and compared in terms of ground and construction conditions (ground loss) considering the magnitude of deformations and cracks in structures. In addition, the damage levels, which are possibly induced in structures, has been provided in terms of ground and construction conditions (ground loss) using the state of strain damage estimation criterion (Son and Cording, 2005). The results of this study will provide a background for better understandings for controlling and minimizing building damage on nearby structures due to tunnelling-induced ground movements.

Model Tests on the Lateral Behavior of Soldier Pile Type Breakwater Installed in Sand (모래지반에 설치된 가로널식 방파제의 횡방향 거동에 관한 모형실험)

  • Jang In-Sung;Lee Goo-Young;Kwon O-Soon;Park Woo-Sun;Jeong Weon-Mu;Kim Byoung-Il
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.1
    • /
    • pp.29-41
    • /
    • 2005
  • The small harbors and fishing ports in Korea have less economic efficiency if the previous construction method of breakwater would be utilized due to bad ground conditions in spite of low design waves. Therefore, it is necessary to develop a new type breakwater economically applicable to the cases with low design wave. In this study, a soldier pile type breakwater, which is found to be economic and can be easily constructed on the ground without any need of treatment of the ground, was newly introduced. The effects of embedded depth, reinforcement methods as well as pile types including saw type and flat type on the lateral behavior of the proposed breakwaters installed in loose sandy soils were investigated from model test. The test results revealed that the lateral resistance increases by increasing the embedded depth and by adopting the reinforcement techniques such as raker and anchor. Furthermore, it was also verified that the saw type breakwater shows better geotechnical performance than the flat type breakwater.

An Experimental Study on Grouting Effect for Ground Reinforcement (지반보강 그라우팅 효과에 관한 실험적 연구)

  • Park, Yong-Won;Lee, Goo-Young;Park, Jong-Ho;Hong, Sung-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.399-406
    • /
    • 2004
  • This paper is experimental study on the effect of improved soil strength which was grouted by pressure grouting method for prevent collapse the tunnel's face during excavate tunnel. This study performs to investigate the proper grouting pressure and grouting method through pressure grouting laboratory model tests using loose dense sandy soil using specially designed and fabricated device($180cm{\times}220cm{\times}300cm$) under changing condition of injection in this test The investigation is carried out through measuring the size and shape of grout bulb, elastic modulus by pressure-meter test Elastic modulus was estimated using relation stress with strain which is result the uni-direction compressive strength test for cured grouted bulb under water during 28days. From these test results, the amount of increased elastic modulus of grouted zone was suggested.

  • PDF

Analysis on Seismic Resistance Capacity of Hollow Concrete Block Reinforced Foundation Ground by Using Shaking Table Test (진동대 시험을 이용한 중공블록 보강 기초의 내진성능분석)

  • Shin, Eun-Chul;Lee, Yeun-Jeung;Yang, Tae Chul
    • Journal of the Korean Geosynthetics Society
    • /
    • v.20 no.4
    • /
    • pp.85-93
    • /
    • 2021
  • The seventy percentage of Korean Peninsular is covered by the mountainous area, and the depth of west sea and south sea is relatively shallow. Therefore, a large scale land reclamation from the sea has been implemented for the construction of industrial complex, residental area, and port and airport facilities. The common problem of reclaimed land is consisted of soft ground, and hence it has low load bearing capacity as well as excessive settlement upon loading on the ground surface. The hollow concrete block has been used to reinforce the loose and soft foundation soil where the medium-high apartment or one-story industrial building is being planned to be built. Recently the earthquakes with the magnitude of 4.0~5.0 have been occurred in the west coastal and southeast coastal areas. Lee (2019) reported the advantages of hollow concrete block reinforced shallow foundation through the static laboratory bearing capacity tests. In this study, the dynamic behavior of hollow concrete block reinforced sandy ground with filling the crushed stone in the hollow space has been investigated by the means of shaking table test with the size of shaking table 1000 mm × 1000 mm. Three types of seismic wave, that is, Ofunato, Hachinohe, Artificial, and two different accelerations (0.154 g, 0.22 g) were applied in the shaking table tests. The horizontal displacement of structure which is situated right above the hollow concrete block reinforced ground was measured by using the LVDT. The relative density of soil ground are varied with 45%, 65%, and 85%, respectively, to investigate the effectiveness of reinforcement by hollow block and measured the magnitude of lateral movement, and compared with the limit value of 0.015h (Building Earthquake Code, 2019). Based on the results of shaking table test for hollow concrete block reinforced sandy ground, honeycell type hollow block gives a large interlocking force due to the filling of crushed stone in the hollow space as well as a great interface friction force by the confining pressure and punching resistance along the inside and outside of hollow concrete block. All these factors are contributed to reduce the great amount of horizontal displacement during the shaking table test. Finally, hollow concrete block reinforced sandy ground for shallow foundation is provided an outstanding reinforced method for medium-high building irrespective of seismic wave and moderate accelerations.

Estimation of Coefficient of Earth Pressure At Rest During SCP Installation by Drained Triaxial Compression Test (배수삼축압축시험을 통한 SCP 시공과정 중 정지토압계수 평가)

  • Kwon, Youngcheul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.11
    • /
    • pp.93-101
    • /
    • 2012
  • SCP is a construction method that maximizes the effects of ground improvement by creating sand piles, which are formed by the compaction within soft ground. SCP is mainly used for consolidation and drain effects in clayey soils, and as a liquefaction countermeasure through effects such as compaction in loose sandy soils. In the design of SCP, if the sand piles with high stiffness are not taken into account, it can become a design that overly considered safety, and increased construction costs are highly likely to cause economic disadvantages. The changes in stress conditions and compaction mechanisms in the subsurface have been identified to a certain extent by study findings to date. However, the studies that considered SCP and in-situ ground as composite ground are fairly limited, and therefore, those studies have not achieved enough results to fully explain the relevant topics. In this study, the ground improved by SCP was regarded as the composite ground that consists of SCP and in-situ ground. Moreover, employing a CID test, this study examined the changes in the stress conditions of in-situ ground according to the installation of SCP through the relations between $K_0$ and SCP replacement ratio. At the same, whether the SCP installation procedure can be recreated in a laboratory was examined using a cyclic triaxial test. According to the test results, the changes in the stress conditions of the original ground occurred most largely in an initial stage of SCP installation, and after a certain time point, the vibration for SCP installation did not have a great influence on the changes in the stress conditions of the ground. Moreover, in order to recreate the behaviors of in-suit ground according to SCP in a laboratory, cyclic loading, which corresponds to casing vibration, was concluded to be essentially required.

An Experimental Study on the Settlement Characteristics of the Corner of Earth Retaining Wall According to the Ground Excavation (지반굴착에 따른 흙막이벽 우각부 모서리 구간의 침하특성에 대한 실험 연구)

  • Yoon, Won-Sub;Cho, Chul-Hyun;Cho, Young-Kweon;Chae, Young-Su
    • Journal of the Korean Geosynthetics Society
    • /
    • v.12 no.2
    • /
    • pp.55-66
    • /
    • 2013
  • The experiment of model soil structures has been executed for the soil retaining wall in various conditions of excavation, in this study, to analyze the behavior of the corner of opening. The ground for experiment has been constituted with the sandy soil of relatively loose density, the construction condition has been divided into the opening length of corner, embedded depth, existence of strut, etc., and the excavation has been carried out for 4 stages in total. The behavior characteristics at the corner of opening area has been verified by concentrate analysis of the displacement of wall and the subsidence of ground surface, for each construction and excavation condition, using the measuring instrument mounted inside the model soil structure. In the result of experiment, it has been analyzed that the opening area of corner is unstable structurally compared to the linear area, as it shows that the wall displacement and subsidence of ground surface have been increased when the opening length of corner gets longer. The longer the embedded depth, ground surface settlement of coner was decreased 40%. To apply deeper embedded depth than designed estimate was an advantage in the safety. As a result of the analysis of coner behavior with added struts, maximum surface settlement and maximum horizontal displacement was evaluated 40% and 30%, respectively. Hence increased embedded depth with the added struts in coner edge was effective in the safety.