• Title/Summary/Keyword: loop removal

Search Result 93, Processing Time 0.025 seconds

Change of Sludge-Recycle Ratio for the Bio-gas Production Improvement and Minimization with Two-Stage Anaerobic Digestion (2단 혐기성소화공정에서 반송변화를 통한 Bio-gas 생산량 증대 및 감량화)

  • Lee, Tae-Woo;Yang, Hae-Young;Do, Choong-Ho
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.15 no.3
    • /
    • pp.83-86
    • /
    • 2012
  • This study have cross checked the change of internal sludge-recycle in Full-scale Anaerobic-Digestion, and researched about not only the improvement of Bio-gas production from the digested sludge but also the efficient method of sludge minimization. Ultimate aim of the study is to reduce the amount of sludge by the improved efficiency of contact with the organic-matter and the microbes in Anaerobic-Digestion. The sludge-recycle fluidized sludge layer and raised the activity of the sludge, The sludge-recycle ratio of optimum was 500%, VS and COD removal ratio respectively appeared with 67.8% and 70.4%. Through these result of this study, it may be positive view to treat waste sludge by the sludge-recycle ratio in terms of minimization and circulation of resources.

A Study on the Free Surface Vortex in the Pipe System (배관내 자유수면에서 와류현상에 대한 연구)

  • Kim, Sang-Nyung;Jang, Wan-Ho
    • Nuclear Engineering and Technology
    • /
    • v.24 no.3
    • /
    • pp.311-318
    • /
    • 1992
  • During mid-loop operation of Nuclear Power Plant, to prevent the Decay Heat Removal System (DHRS) from failure due to air entrainment of free surface vortex in the piping system, a set of simulating experiments was performed. Through these experiments, a relation between the non-dimensionalized numbers, such as H/d, Froude number, Reynolds number, was found. It was also found that the perturbation of the system by the disturbance such as pump start, valve operation, etc., has a strong effect on the free surface vortex. Furthermore, from viewpoint of reactor safety, a modified inlet device which is reducer type is strongly recommended for the prevention of air entrainment into DHRS.

  • PDF

RELAP5 Analysis of the Loss-of-RHR Accident during the Mid-Loop Operation of Yonggwang Nuclear Units 3/4

  • J. J. Jeong;Kim, W. S.;Kim, K. D.;W. P. Chang
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.403-410
    • /
    • 1995
  • A loss of the residual heat removal (RHR) accident during mid-loop operation of Yong-gwang Nuclear Units 3/4 was analyzed using the RELAP5/MOD3.1.2 code. In this work the following assumptions are used; (i) initially the reactor coolant system (RCS) above the hot leg center line is filled with nitrogen gas, (ii) two 3/4-inch diameter vent valves on the reactor vessel head and the top of pressurizer in the reactor coolant system are always open, and a level indicator is connected to the RMR suction line, (iii) the two steam generators are in wet layup status and the steam generator atmospheric dump valve assemblies are removed so that the secondary side pressure remains at nearly atmospheric condition throughout the accident, and (iv) the loss of RHR is presumed to occur at 48 hours after reactor shutdown. Findings from the RELAP5 calculations are (i) the core boiling begins at ∼5 min, (ii) the peak RCS pressure is ∼3.0 bar, which implies a possibility of temporary seal break, (iii) ∼94 % of the decay heat is removed by reflux condensation in the steam generator U-tubes in spite of the presence of noncondensable gas, (iv) the core uncovery time is evaluated to be 7.2 hours. Significant mass errors were observed in the calculations.

  • PDF

Degradation from Polishing Damage in Ferroelectric Characteristics of BLT Capacitor Fabricated by Chemical Mechanical Polishing Process (화학적기계적연마 공정으로 제조한 BLT Capacitor의 Polishing Damage에 의한 강유전 특성 열화)

  • Na, Han-Yong;Park, Ju-Sun;Jung, Pan-Gum;Ko, Pil-Ju;Kim, Nam-Hoon;Lee, Woo-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.236-236
    • /
    • 2008
  • (Bi,La)$Ti_3O_{12}$(BLT) thin film is one of the most attractive materials for ferroelectric random access memory (FRAM) applications due to its some excellent properties such as high fatigue endurance, low processing temperature, and large remanent polarization [1-2]. The authors firstly investigated and reported the damascene process of chemical mechanical polishing (CMP) for BLT thin film capacitor on behalf of plasma etching process for fabrication of FRAM [3]. CMP process could prepare the BLT capacitors with the superior process efficiency to the plasma etching process without the well-known problems such as plasma damages and sloped sidewall, which was enough to apply to the fabrication of FRAM [2]. BLT-CMP characteristics showed the typical oxide-CMP characteristics which were related in both pressure and velocity according to Preston's equation and Hernandez's power law [2-4]. Good surface roughness was also obtained for the densification of multilevel memory structure by CMP process [3]. The well prepared BLT capacitors fabricated by CMP process should have the sufficient ferroelectric properties for FRAM; therefore, in this study the electrical properties of the BLT capacitor fabricated by CMP process were analyzed with the process parameters. Especially, the effects of CMP pressure, which had mainly affected the removal rate of BLT thin films [2], on the electrical properties were investigated. In order to check the influences of the pressure in eMP process on the ferroelectric properties of BLT thin films, the electrical test of the BLT capacitors was performed. The polarization-voltage (P-V) characteristics show a decreased the remanent polarization (Pr) value when CMP process was performed with the high pressure. The shape of the hysteresis loop is close to typical loop of BLT thin films in case of the specimen after CMP process with the pressures of 4.9 kPa; however, the shape of the hysteresis loop is not saturated due to high leakage current caused by structural and/or chemical damages in case of the specimen after CMP process with the pressures of 29.4 kPa. The leakage current density obtained with positive bias is one order lower than that with negative bias in case of 29.4 kPa, which was one or two order higher than in case of 4.9 kPa. The high pressure condition was not suitable for the damascene process of BLT thin films due to the defects in electrical properties although the better efficiency of process. by higher removal rate of BLT thin films was obtained with the high pressure of 29.4 kPa in the previous study [2].

  • PDF

Post-Loop Electrosurgical Excision Procedure Complications in Srinagarind Hospital

  • Maleerat, Pimjai;Chumworathayi, Bandit;Kietpeerakool, Chumnan;Luanratanakorn, Sanguanchoke;Temtanakitpaisan, Amornrat
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.4
    • /
    • pp.2211-2215
    • /
    • 2016
  • The purpose of this study was to evaluate the prevalence and predictors of post-Loop Electrosurgical Excision Procedure (LEEP) complications in Srinagarind Hospital, Khon Kaen, Thailand. Retrospective chart review was performed for 200 patients undergoing LEEP during January 2012 to February 2013. Their mean age was 45 years-old. Fifty-three (26.5%) were menopausal. The three most common preceding abnormal cervical cytology were high-grade squamous intraepithelial lesion (HSIL; 50%), atypical squamous cell cannot exclude HSIL (ASC-H; 10.5%), and low-grade squamous intraepithelial lesion (LSIL; 10%). The overall complications prevalence rate was 16.5% (95%CI, 11.4-21.6). Complications included bleeding (11%; 95%CI, 6.66-15.3), offensive discharge (4%; 95%CI, 1.28-6.72), and pelvic inflammatory disease (1.5%; 95%CI, 0.18-3.18). Only mode of delivery was an independent predictor of post-LEEP complications. Women with previous caesarean sections carried an increased risk of complications by 3.9 times (95%CI, 1.21-12.56) compared with vaginal delivery. In conclusion, LEEP is generally safe with an acceptable complication rate. Previous caesarean section was the only independent predictor for post-LEEP complications. However, this predictor still needs prudent evaluation as no clear cause-effect relationship was identified.

Implementation of Integrated Controller of ACC/LKS based on OSEK OS (OSEK OS 기반 ACC/LKS 통합제어기 구현)

  • Choi, Dan-Bee;Lee, Kyung-Jung;Ahn, Hyun-Sik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.5
    • /
    • pp.1-8
    • /
    • 2013
  • This paper implements an integrated vehicle chassis system of ACC(Adaptive Cruise Control) and LKS(Lane Keeping System) based on OSEK OS to vehicle operating system and analyzes its performance through experiments. In recent years active safety and advanced driver assistance system has discussed to improve safety of vehicle. Among the rest, We integrate ACC that controls longitudinal velocity of vehicle and LKS that assists a vehicle in maintaing its driving lane, then implement integrated control system in vehicle. Implemented control system uses OSEK/VDX proposed standard, which is aiming at reusability and safety of software for vehicle and removal hardware dependence of application software. Redesigned control system based on OSEK OS, which is supported by OSEK/VDX, can manage real-time task, process interrupt and manage shared resource. We show by results performed EILS(ECU-In-the-Loop Simulation) that OSEK OS-based integrated controller of ACC and LKS is equivalent conventional integrated controller of ACC and LKS.

Impact of an expanded reimbursement policy on utilization of implantable loop recorders in patients with cryptogenic stroke in Korea

  • Hye Bin Gwag;Nak Gyeong Ko;Mihyeon Jin
    • The Korean journal of internal medicine
    • /
    • v.39 no.3
    • /
    • pp.469-476
    • /
    • 2024
  • Background/Aims: The reimbursement policy for cryptogenic stroke (CS) was expanded in November 2018 from recurrent strokes to the first stroke episode. No reports have demonstrated whether this policy change has affected trends in implantable loop recorder (ILR) utilization. Methods: We identified patients who received an ILR implant using the Korea Health Insurance Review and Assessment Service database between July 2016 and October 2021. Patients meeting all the following criteria were considered to have CS indication: 1) prior stroke history, 2) no previous history of atrial fibrillation or flutter (AF/AFL), and 3) no maintenance of oral anticoagulant for ≥4 weeks within a year before ILR implant. AF/AFL diagnosed within 3 years after ILR implant or before ILR removal was considered ILR-driven. Results: Among 3,056 patients, 1,001 (32.8%) had CS indications. The total ILR implant number gradually increased for both CS and non-CS indications and the number of CS indication significantly increased after implementing the expanded reimbursement policy. The detection rate for AF/AFL was 26.3% in CS patients over 3 years, which was significantly higher in patients implanted with an ILR within 2 months after stroke than those implanted later. Conclusions: The expanded coverage policy for CS had a significant impact on the number of ILR implantation for CS indication. The diagnostic yield of ILR for AF/AFL detection seems better when ILR is implanted within 2 months than later. Further investigation is needed to demonstrate other clinical benefits and the optimal ILR implantation timing.

Structural design concept of the forced-draft sodium-to-air heat exchanger in the decay heat removal system of PGSFR (소듐냉각고속로 잔열제거계통 강제대류 소듐-공기 열교환기의 구조개념 설계)

  • Kim, Nak Hyun;Lee, Sa Yong;Kim, Sung Kyun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.78-84
    • /
    • 2016
  • The FHX (Forced-draft sodium-to-air Heat Exchanger) employed in the ADHRS (active decay heat removal system) is a shell-and-tube type counter-current flow heat exchanger with M-shape finned-tube arrangement. Liquid sodium flows inside the heat transfer tubes and atmospheric air flows over the finned tubes. The unit is placed in the upper region of the reactor building and has function of dumping the system heat load into the final heat sink, i.e., the atmosphere. Heat is transmitted from the primary cold sodium pool into the ADHRS sodium loop via DHX (decay heat exchanger), and a direct heat exchange occurs between the tube-side sodium and the shell-side air through the FHX tube wall. This paper describes the DHRS and the structural design of the FHX.

Design of ALIP with Flowrate of 40 I/min for the Removal of Residual Heat (잔열 제거용 40 I/min급 환단면 선형유도전자펌프의 설계)

  • Kim, H.R.;Nam, H.Y.;Kim, Y.G.;Choi, B.H.;Kim, J.M.;Hwang, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.13-15
    • /
    • 1998
  • EM(Electro Magnetic) pump is used for the purpose of transporting liquid sodium coolant with electrical conductivity in the LMR(Liquid Metal Reactor). In the present study. pilot EM pump has been designed by using of equivalent circuit method which is commonly employed to analyze linear induction machines for the test of removal of residual heat. The length and diameter of the pump have fixed values of 840 mm and 101.6 mm each by taking account of geometrical size of circulation loop for the installation of EM pump. Flowrate versus developing pressure is related from Laithwaite's standard design formula and the characteristic analyses of developing force and efficiency are carried out according to change of input frequency. From the characteristic curve, input frequency of 13 Hz is determined as the design frequency. On the other hand, The annular air gap size of 6.05 mm is selected not to bring about too much hydraulic loss. Resultantly design analysis makes pump have the electrical input of 604 VA and the hydrodynamical capacity of 1.3 bars and 40 l/min.

  • PDF

Furnish Potential for Packaging Papers-Influence on Plant Design and Product Quality

  • Feridun Dormischian;Dietmar Borschke
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2000.06a
    • /
    • pp.34-39
    • /
    • 2000
  • Today's size of production operations in the packaging paper sector I sconstantly increasing , featuring integral processing systems, high-speed paper machines, and the increased marketing of lower basis weight products. The risk factors involved in these large investments lie more than ever in the available furnish potential and ongoing requirements for further closure of water loops and lower operating costs. A comparison is drawn between recovered paper furnish mixtures used in European mills with regard to fibre properties, strength potential and contaminant content, Both the furnish situation and development trends in modern fluting and testliner machines are instigating concept changes in stock preparation, the approach flow as well as in process water and rejects technology. Developments are currently focussed for example on more efficient debris separation using fine slotted screening, optimized refining , more systematic process water management with loop separation and integral water clarification as well as more efficient removal of microstickies, fillers and fines through appropriate combination of rejects handling and water clarification processes. Product quality differentiation depends decisively on strength characteristics as a function of refining , fines removal , paper machine technology, and sizing . Maximum availability of today's high speed paper machines and , as a result, cost effective production can be ensured by optimum balancing of all subsystems with in the overall concept and by reliable control of problems with contaminants and deposits.