• Title/Summary/Keyword: loop

Search Result 8,947, Processing Time 0.034 seconds

Functional Understating of Fibroblastic Reticular Cell within Lymph Node Stroma (림프절 스토로마 내의 fibroblastic reticular cell의 기능 이해)

  • So, Deuk Won;Ryu, Sul Hwa;Lee, Jong-Hwan
    • Journal of Life Science
    • /
    • v.23 no.11
    • /
    • pp.1409-1414
    • /
    • 2013
  • Lymph node (LN) is the sites where mature lymphocytes become stimulated to respond to invading pathogens in the body. Lymphocytes screen the surfaces of pathogen-carrying antigen-presenting cells for cognate antigens, while moving along stromal structural back bone. Fibroblastic reticular cells (FRC) is stromal cell forming the 3 dimensional structure networks of the T cell rich zones in LN, and provide a guidance path for immigrating T lymphocytes. In these cooperative environments, the cell to cell bidirectional interactions between FRC and T cells in LN are therefore essential to the normal functioning of these tissues. Not only do FRCs physically construct LN architecture but they are essential for regulating T cell biology within these domains. FRC interact closely with T lymphocytes, is providing scaffolds, secreting soluble factors including cytokine in which FRCs influence T cell immune response. More recently, FRC have been found to induce peripheral T cell tolerance and regulate the extent to which newly activated T cells proliferate within LN. Thus, FRC-T cell crosstalk has important consequences for regulating immune cell function within LN. In addition, FRC have profound effects on innate immune response by secreting anti-microbial peptides and complement, etc in the inflammatory milieu. In summary, we propose a model in which FRC engage in a bidirectional touch to increase the T cell biological efficiency between FRC and T cells. This collaborative feedback loop may help to maintain tissue function during inflammation response.

The heat transfer characteristics of viscoelastic non-newtonian fluids in the entrance region of circular tube flows (원형관속을 유동하는 점탄성 유체의 입구 영역 열전달 특성에 관한 연구)

  • 엄정섭;황태성;유상신
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.5
    • /
    • pp.1032-1043
    • /
    • 1989
  • The heat transfer characteristics of the drag reducing polymer solutions are investigated experimentally in the thermal entrance region of circular tube flows. Fluids used in experiments are the aqueous solutions of high molecular polymer, polyacrylamide Separan AP-273 and the range of polymer concentrations is from 20 to 1000 wppm. Two stainless steel tubes with inside diameter 8.5mm(L/D=712) and 10.3mm(L/D=1160) are used for the heat transfer flow loops. The flow loop is set up to measure friction factors and heat transfer coefficients of test sections in two different modes; the recirculating flow system and once-through flow system. The test tubes are heated directly by electricity to apply the constant heat flux boundary conditions to the wall. Three different types of adaptors are used to observe the effects of the upstream flow conditions of the heat transfer test sections. The viscosity and characteristic relaxation time of the test fluids circulating in the flow system are measured by the capillary tube viscometer and falling ball viscometer at regular time intervals. The installed adaptors exhibit slight effect on the entrance heat transfer of Newtonian fluid. However, no noticeable effects are observed for the entrance heat transfer of the drag reducing fluids. The order of magnitude of the thermal entrance lengths of the drag reducing fluids which follow the minimum friction asymptote is much longer than that of Newtonian fluids in turbulent flows. A new dimensionless parameter, the viscoelastic Graetz number, is defined and all the experimental data are recasted in terms of the viscoelastic Graetz number. The local Nusselt number of the viscoelastic fluids is represented as a function of flow behavior index n and the viscoelastic Graetz number. As degradation continues the viscosity and the characteristic relaxation time of the testing fluids decrease. Weissenberg number defined by the relaxation time and D/V appears to be a proper dimensionless parameter in describing degradation effects on heat transfer of the viscoelastic fluids.

The Recurrent Pregnancy Loss Associated with a Female Carrier of a Structural Chromosome Rearrangement (염색체 구조적 이상을 가진 산모의 재조합에 의한 태아의 비정상 핵형분석결과의 증례보고)

  • Lee, Soo-Min;Go, Sang-Hee;Jo, Soo-Kyung;Park, So-Hyun;Moon, Soo-Jin;Lee, Dong-Suk;Kim, Ki-Chul;Hwang, Do-Yeong
    • Journal of Genetic Medicine
    • /
    • v.7 no.2
    • /
    • pp.156-159
    • /
    • 2010
  • Inversion, one of the balanced rearrangements, usually does not lead to phenotypic abnormalities; all genetic information exists in the proper amount, merely in a different order or in an abnormal location. However, offspring of an inversion carrier is at risk of chromosomal imbalance because an inversion loop can be formed during crossing-over of the paternal and the maternal chromosomes in meiosis. We report a 38-year-old woman with inversion and balanced translocation and her fetus with unusual rearrangement causing chromosomal imbalance. We performed conventional cytogenetic analysis, MLPA, and subtelomeric FISH in the cells of the embryo. The results showed that the distal portion of chromosome 13q was added to the terminal portion of chromosome 9p during crossing-over. Therefore, the final karyotype of the fetus was 46,XY,rec(9)t(9;13)(p22;q32)inv(9)(p12q13)mat, confirmed using molecular-cytogenetic analyzing tools.

Development of Induction Brazing System for Sealing Instrumentation Feedthrough Part of Nuclear Fuel Test Rig (핵연료조사리그 계장선 통과부위의 밀봉을 위한 유도 브레이징 시스템 개발)

  • Hong, Jintae;Kim, Ka-Hye;Heo, Sung-Ho;Ahn, Sung-Ho;Joung, Chang-Young;Son, Kwang-Jae;Jung, Yang-Il
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.12
    • /
    • pp.1573-1579
    • /
    • 2013
  • To test the performance of nuclear fuels, coolant needs to be circulated through the test rig installed in the test loop. Because the pressure and temperature of the coolant is 15.5 MPa and $300^{\circ}C$ respectively, coolant sealing is one of the most important processes in fabricating a nuclear fuel test rig. In particular, 15 instrumentation cables installed in a test rig pass through the pressure boundary, and brazing is generally applied as a sealing method. In this study, an induction brazing system has been developed using a high frequency induction heater including a vacuum chamber. For application in the nuclear field, BNi2 should be used as a paste, and optimal process variables for Ni brazing have been found by several case studies. The performance and soundness of the brazed components has been verified by a tensile test, cross section test, and sealing performance test.

Enhanced Expression and Substrate Specificity Changes of Barley $\alpha$-Amylase Isozyme 2 in E. coli by Substitution of the $42^{nd}$ Alanine Residue with Proline (42번째 alanine 잔기의 proline 치환에 의한 보리 $\alpha$-amylase isozyme 2의 대장균 내 발현 증가 및 기질특이성 변화)

  • Choi, Seung-Ho;Jang, Myoung-Uoon;Lee, Hong-Gyun;Svensson, Birte;Kim, Tae-Jip
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.2
    • /
    • pp.198-203
    • /
    • 2010
  • Although barley $\alpha$-amylase isozyme 1 (AMY1) and 2 (AMY2) share up to 80% of amino acid sequence identity, their enzymatic properties differ remarkably. In this study, the 42nd alanine residue of AMY2 was replaced with another random amino acid via saturation mutagenesis. Eight out of 370 recombinant E. coli cells showing enhanced starch-hydrolyzing activity were characterized as possessing the same proline residue instead of alanine. Even though the specific activity of AMY2-A42P is reduced to 81% of wild-type, its expression level and purification yield were enhanced by approximately 2 and 4 times that of AMY2, respectively. Characterization of its enzymatic properties confirmed that AMY2-A42P is similar to that of wild-type. However, its specificity to starch substrates is likely to be intermediate between AMY1 and AMY2.

A Priority Based Multipath Routing Mechanism in the Tactical Backbone Network (전술 백본망에서 우선순위를 고려한 다중 경로 라우팅 방안)

  • Kim, Yongsin;Shin, Sang-heon;Kim, Younghan
    • Journal of KIISE
    • /
    • v.42 no.8
    • /
    • pp.1057-1064
    • /
    • 2015
  • The tactical network is system based on wireless networking technologies that ties together surveillance reconnaissance systems, precision strike systems and command and control systems. Several alternative paths exist in the network because it is connected as a grid to improve its survivability. In addition, the network topology changes frequently as forces and combatants change their network access points while conducting operations. However, most Internet routing standards have been designed for use in stable backbone networks. Therefore, tactical networks may exhibit a deterioration in performance when these standards are implemented. In this paper, we propose Priority based Multi-Path routing with Local Optimization(PMPLO) for a tactical backbone network. The PMPLO separately manages the global and local metrics. The global metric propagates to other routers through the use of a routing protocol, and it is used for a multi-path configuration that is guaranteed to be loop free. The local metric reflects the link utilization that is used to find an alternate path when congestion occurs, and it is managed internally only within each router. It also produces traffic that has a high priority privilege when choosing the optimal path. Finally, we conducted a simulation to verify that the PMPLO can effectively distribute the user traffic among available routers.

Evaporation Heat Transfer Characteristics of Carbon Dioxide in a Diameter Tube of 4.57mm (내경 4.57mm 관내 CO2의 증발 열전달 특성)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.574-579
    • /
    • 2008
  • The evaporation heat transfer coefficient of $CO_2$ (R-744) in a horizontal tube was investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator (test section). The test section consists of a smooth, horizontal stainless steel tube of inner diameter of 4.57mm. The experiments were conducted at mass flux of 400 to $900kg/m^2s$, saturation temperature of 5 to $20^{\circ}C$, and heat flux of 10 to $40kW/m^2$. The test results showed the heat transfer of $CO_2$ has a greater effect on nucleate boiling more than convective boiling. Mass flux of $CO_2$ does not affect nucleate boiling too much. In comparison with test results and existing correlations, All of the existing correlations for the heat transfer coefficient underestimated the experimental data. However Jung et al.'s correlation showed a good agreement with the experimental data. Therefore, it is necessary to develope accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in horizontal tubes.

Design of a CCM/DCM dual mode DC-DC Buck Converter with Capacitor Multiplier (커패시터 멀티플라이어를 갖는 CCM/DCM 이중모드 DC-DC 벅 컨버터의 설계)

  • Choi, Jin-Woong;Song, Han-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.21-26
    • /
    • 2016
  • This paper presents a step-down DC-DC buck converter with a CCM/DCM dual-mode function for the internal power stage of portable electronic device. The proposed converter that is operated with a high frequency of 1 MHz consists of a power stage and a control block. The power stage has a power MOS transistor, inductor, capacitor, and feedback resistors for the control loop. The control part has a pulse width modulation (PWM) block, error amplifier, ramp generator, and oscillator. In this paper, an external capacitor for compensation has been replaced with a multiplier equivalent CMOS circuit for area reduction of integrated circuits. In addition, the circuit includes protection block, such as over voltage protection (OVP), under voltage lock out (UVLO), and thermal shutdown (TSD) block. The proposed circuit was designed and verified using a $0.18{\mu}m$ CMOS process parameter by Cadence Spectra circuit design program. The SPICE simulation results showed a peak efficiency of 94.8 %, a ripple voltage of 3.29 mV ripple, and a 1.8 V output voltage with supply voltages ranging from 2.7 to 3.3 V.

Development of UHF Band Tag Antenna using Radio Frequency Identification Multipurpose Complex Card (RFID 다기능 복합 카드용 UHF 대역 소형 태그 안테나 개발)

  • Byun, Jong-Hun;Sung, Bong-Geun;Choi, Eun-Jung;Ju, Dae-Geun;Yoo, Dae-Won;Cho, Byung-Lok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.12B
    • /
    • pp.1452-1458
    • /
    • 2009
  • In this paper, Our proposed Multipurpose Complex Card UHF band RFID small-size Tag antenna. Multi purpose Complex Card UHF band RFID small-size Tag antenna that is to minimize the low efficiency of RFID Tag Read Range that generates space limitation and a conductor surrounded by inducing fingerpring system with dual(HF, UHF) Card is presented. Our proposed UHF band RFID small-size Tag antenna is for the Multipurpose Complex Card that is mounted on the fingerpring system as well as the HF Tag. It also enables to minimize and facilitates Tag chip matching by adjusting Tapered, Meander line and Loop structure. Given the card substance properties and periphery circuit, the proposed small-size Tag antenna, in this report, is designed with PET film with size of $50{\times}15mm^2$. The RFID small-size Tag method for measurements is used by EPCglobal Static Test instrument in Anechoic Chamber, which is tested with dual Card, within the car and in wallet. It is found that Read Range is 3.8m from the EPCglobal Static Test, Maximum Read Range within the car from the field test results in 7.6m. Proposed Tag antenna is will be used in the parking control security system.

A study on the bedrock erosional forms at Dutayeon, Yanggu (양구 두타연 인근 지역의 기반암 하상지형 연구)

  • KIM, Jong Yeon;KIM, Chang Hwan
    • Journal of The Geomorphological Association of Korea
    • /
    • v.19 no.2
    • /
    • pp.31-49
    • /
    • 2012
  • Satae cheon, a tributary of the Suip cheon in Yanggu, Gangwon province, is an international river extended to North Korea. Most of drainage basin area of the river was the fierce battle field during the Korean War(1950-1953) and hard to access as it located between the MDL(Military Demarcation Line) and the CCZ(Civilian Control Zone: about 10km south from MDL). By the restriction of access to the sites, most of natural landscape have been well conserved except limited use for military activities. Even the landfoms in that area were not studied, except the government's heritage reports. Satae Cheon's channel follows the Imdang fault line(N-S) to Satae-ri and flow to west to the Dutayeon area. The river meanders along geological structure or weak line at the Dutayeon area. The meandering channel was shorten by the meander cut which linked the thalweg line of meander loop ant the meander neck. As a result of this cut, the river cliff formed by the Satae cheon became the part of newly formed channel bed and the S-forms are formed. After the channel route stabilized, channel incised the rock with large potholes and undulating walls were formed. The channel width changes from 1m to 10m with restriction of the undulating walls, so this part can be regarded as inner channel or inner gorge. From the point of planar forms it also can be slot-type canyon.